Blodgett SC-10E User Manual

Project
Item No.
Quantity
Model SC-7E (7 pan electric convection steamer)Model SC-10E (10 pan electric convection steamer)
EXTERIOR CONSTRUCTION
304 satin finish stainless steelWelded stainless steel door with removable inner stainless steel linerFull perimeter door gasketPositive lock and seam mechanism with spring release on doorStainless steel control housing
INTERIOR CONSTRUCTION
One piece welded 316 stainless steel cooking chamberCoved cornersStainless steel pan supportsStainless steel drip trough integrally connected to drain
OPERATION
Pressureless steam operationDelime mode power settingAutomatic generator blowdownSeparate controls for each compartmentFull access removable control panelIlluminated on/off/delime power switchReady indicator lightCooking indicator light60 minute electric timer with audible alarm to signal end of cook cycleSolid state generator controlsSteam flow to the cooking chamber is cut off when the door is opened
during the cooking cycle and reactivated when the door is closed
STANDARD FEATURES
Deliming port located in the rear of the unit for each generatorDeliming mode power settingElectromechanical controlslSplit water connections24” wide cabinet base with hinged door and 6” (152 mm) legsStandard voltage options
208 VAC, 3 phase, 60 hz
240 VAC, 3 phase, 60 hzOne year parts and labor steamer warranty*Five year limited steamer door warranty*
* For all international markets, contact your local distributor.
BLODGETT OVEN COMPANY
www.blodgett.com
44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183
OPTIONS AND ACCESSORIES
(AT ADDITIONAL CHARGE)
Voltage options
220 VAC, 3 phase, 60 hz240 VAC, 3 phase, 60 hz220/380, 3 phase, 60 hz, 4 wire240/415, 3 phase, 60 hz, 4 wire380 VAC, 3 phase 60 hz415 VAC, 3 phase, 60 hz480 VAC, 3 phase, 60 hz
600 VAC, 3 phase, 60 hz12” x 20” (305 x 508 mm) pan guides for cabinet base120 minute timerCorrectional packageOne year extended warranty
SC-E
Electric Convection Steamer
on a 24” Modular Cabinet Base
SC-E CONVECTION STEAMER
Model
Pan Depth
1” 2.5” 4” 6”
SC-7E 14 7 4 2 SC-10E 20 10 6 4
CAPACITY
Model SC-7E is comprised of one 3 pan steamer com-
partment and one 4 pan steamer compartment
Model SC-10E is comprised of two 5 pan steamer com-
partments
SC-7E shown
BLODGETT OVEN COMPANY
www.blodgett.com 44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183
SC-E CONVECTION STEAMER
SHORT FORM SPECIFICATIONS
Provide Blodgett model SC-7E (7 pan), SC-10E (10 pan) convection steamer with electric steam generator mounted on a 24” wide cabinet base. The SC-7E is comprised of one 3 pan compartment on top of one 4 pan compartment. The SC-10E is comprised of two 5 pan compartments. Each compartment shall have it’s own steam generator. Unit shall be constructed of satin finish 304 stainless steel with a one piece 316 welded stainless steel cooking chamber with coved corners. The door shall have a removable inner liner of stainless steel with full perimeter gasket seal, an outer liner of one-piece all welded stainless steel, and a positive lock and seal mechanism with spring release. Each compartment shall have removable stain­less steel pan supports and a stainless steel drip trough integrally connected to collect and drain condensate with the doors are open. The control housing shall be constructed of stain­less steel with a full access removable panel. The controls shall include an illuminated on/off/delime power switch, a ready indicator light, cooking indicator light, 60 minute electric timer with audible alarm that signals the end of the cook cycle, solid state generator controls and delime mode power setting. Steam flow to the compartment shall be cut off when the door is opened during the cook cycle and shall be reactivated when the door is closed. Unit shall have a deliming port located in the rear. The unit shall have an automatic generator blow down and split water connections. Provide options and accessories as indicated.
WATER SUPPLY:
Water quality is a major factor affecting the performance of your steamer. If you are unsure of water quality, consult a local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids: Less than 60 PPM Total alkalinity: Less than 20 PPM Silica: Less than 13 PPM Chlorine: Less than 1.5 PPM pH Factor: 7.0 - 8.5 Water which fails to meet these standards should be treated by installation of a water conditioner. Failure or malfunction of this steamer due to poor water quality is not covered
under warranty.
WATER & DRAIN CONNECTIONS:
Drain 1” (25mm) IPS piped to open floor drain. No solid connection.
24” length before open air gap opening (no bends or elbows) Cold Water 3/8” (10mm) tubing at 25-50 PSI (170-345 kPa) Appliance is to be installed with backflow protection in accordance with Federal, State or
Local codes.
MAXIMUM INPUT:
SC-7E 17.5 kW SC-10E 24kW standard, 30 kW (optional)
POWER CONNECTION:
1-1/8” (29mm) hole for electrical connection
SHIPPING INFORMATION:
Approx. Weight:
SC-7E 400 lbs. (181 kg) SC-10E 450 lbs. (204 kg)
Printed in U.S.A. NOTE: FOR COMMERCIAL USE ONLY
NOTE: The company reserves the right to make substitutions of components without prior notice.
9 [229]
16.75 [425]
33 [838]
1.38 [35]
24 [610]
1.12 [29]
27.38 [695]
1/2-NPT DELIME INLET
27.69 [703]
2.19 [56]
3.94 [100]
3 [76]
1.75 [45]
28 [711]
6 [152]
1.5 [38]
1 [25]
5 [127]
2.62 [67]
16.62 [422]
63.75 [1619] SC-7E
73.5 [1867] SC-10E
SC-7E
SC-10E
19.88 [505]
19.5 [495]
2.19 [56]2.19 [56]
REAR FLANGED FOOT DETAIL
7/16" [11mm] HOLES
ON 2.5 [63] B.C.
2 EQUALLY SPACED Ø
APPROVAL/STAMP
P/N S00010 Rev J (8/11)
AMPS PER LINE
kW Phase 208V 220V 240V 380V 480V
17.5 3 48.6 45.9 42.1 26.6 21.1
24 3 66.6 63 57.8 36.5 28.9
30 3 83.3 78.7 72.2 45.6 36.1