Congratulationson yourpurchase of aBLODGETT Combi appliance.We
firmly believe that your choice has been a wise one, and trust you will receive many years of excellent service from your new Combi.
You will find that cooking with Combi appliances saves time, labor and
extensive cleaning of both the kitchen and the unit.
With Combi appliances the quality, taste, consistency, and look of your
food are improved, thus endorsing the policy to which we’ve always adhered: “For Better Cooking!”
Once you’ve had a chance to use your Combi, please t ell us, your dealer
and colleagues about any creative and interesting applications you have
discovered; exchange ideas with other users. Be sure to advise us or
your dealer immediately should any mechanical or technical problems
be encountered (...we’re here to help!) and above all “Enjoy Cooking the
BLODGETT Combi Way!
For information on cooking, please refer to our separate cooking guide.
Toutes nos félicitations sur votre achat d’appareil de Blodgett Combi.
Nous croyons fermement que votre choix est un choix raisonnable et
nous sommes certains que vous obtiendrez de nombreuses années
d’excellent service de votre nouveau four multi-usages.
Vous allez découvrir que la cuisson dans les appareils Combi économise
le temps, le travail et le degré de nettoyage de l’appareil aussi bien que
de la cuisine.
Avec les appareil de Combi, la qualité, le goût, la consistence et l’apparence des aliments sont améliorés, s’accordant, de ce fait, avec notre
politique ”Pour une meilleure cuisson !”
Une fois que vous aurez eu la chance d’utiliser notre Combi, informez
nous, votre concessionnaire et vos collègues, de toutes les applications
nouvelles et intéressantes que vous avez découvertes ; échangez vos
idées avec d’autres utilisateurs. N’hésitez pas à nous prévenir, ou votre
concessionnaire, de tout problème mécanique ou technique que vous
pourriez rencontrer (... nous sommes ici pour vous aider) et par-dessus
tout “Régalez-vous à cuisiner à la façon BLODGETT Combi!
Pour obtenir de plus amples informations sur l’art culinaire, veuillez con sulter notre livre de cuisine séparé.
IMPORTANT
WARNIN G:IMPROPER INSTALL ATION, ADJUSTMENT, AL TERATION, SERVICE OR
MAINTENAN C E CAN CAUSE PROPERTY DAMAGE,INJURY OR DEATH. READ THE
INSTALLA TION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING THIS EQUIPMENT
AVERTI SSEMEN T: UNE INSTALL ATION, UN AJUSTEMENT, UNE ALTÉRATI ON, UN
SERVICE OU UN ENTRETIEN NON CONFORME AUX NORMES PEUT CAUSER DES
DOMMAGESÀ LA PROPRIÉTE,DES BLESSURES OU LA MORT. LISEZATTENTIVEMENT LES DIRECTIVES D’INSTALLATIO N ,D’OPÉRATION ET D’ENTRETI ENAV ANT
DE FAIRE L’IN S TALLATI ON OU L’ENTRETIEN DE CET ÉQUIPEMENT.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS
MUST BE POSTED IN A PROMINENT LOCATION. THIS INFORMATION MAY BE
OBTAINED BY CONTACTING YOUR LOCAL GAS SUPPLIER.
LES INSTRUCTIONS À RESPECTER AU CAS OÙ L’UTILISATEUR PERÇOIT UNE
ODEUR DE GAZ DOIVENT ÊTRE AFFICHÉES DANS UN ENDROIT BIEN VISIBLE.
VOUS POUVEZ VOUS LES PROCURER AUPRÈS DE VOTRE FOURNISSEUR DE
GAZ LOCAL.
FORYOURSAFETY
Do not store or use gasoline or other flammable vapors or liquids in the vicinity
of this or any other appliance.
AVERTIS SEMENT
Ne pas entreposer ni utiliser de l’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appariel, ni de tout autre appareil.
The information contained in this manual is i mportant for the proper installation,
use, and maintenance of this oven. Adherence to these procedures and instructions will result in satisfactory baking results and long, trouble free service.
Please read this manual carefully and retain it for future reference.
Les informatio ns données dans le présent manuel sont importantes pour installer,
utiliser et entret en ir correctement ce four. Le respect de ces instructions et procédures permettra d’obtenir de bons résultats de cuisson et une longuedurée de service sans problèmes. Veuillez lire le présent manuel et le conserver pour pouvoir
vous y reporter à l’avenir.
Errors: Descriptive, typographic or pictorial errors are subject to correction. Specifica-
tions are subject to change without notice.
Erreurs:Les erreurs de description, de typographie ou d’illustration font l’objet de
corrections. Les caractéristiques sont sujettes à modifications sans préavis.
Your Service Agency’s Address:
Adressedevotreagencedeservice:
Model/Modèl:
Serial Number/Numéro de série:
Your oven was installed by/
Installateur de votre four:
Your oven’s installation was checked by/
Contrôleur de l’installation de votre four:
Table of Contents/Table des Matières
Introduction
The Blodgett Combi Cooking Line2......
Description of the Blodgett Combi
Cooking Line3.........................
Oven Features4.......................
Installation
Owner’s Responsibilities5...............
Location and Ventilation6...............
Agency Approvals7....................
Utility Connections8....................
Final Check and Adjustments12..........
Final Check Lists13.....................
Operation
Safety Information14....................
Oven Start-Up15........................
Combi-Oven/Steamer
Standard Controls16....................
Optional Combi-Oven/Steamer
Cook & Hold18.........................
Convection Steamer Standard Controls21.
Convection Oven Standard Controls22....
Optional Convection
Oven Cook and Hold23..................
Optional Meat Probe26..................
Maintenance
Spray Bottle Operating Procedure27......
Cleaning and Preventive Maintenance28...
Decalcification29.......................
Introduction
Laligned’appareilsdecuisson
de Blodgett Combi30....................
Description de la ligne d’appareils de
cuisson de Blodgett Combi32............
Caractéristiques33......................
Installation
Responsabilités du propriétaire34.........
Placement et Ventilation35..............
Normes et Codes36.....................
Branchement Utilitaires37................
Vérification finale et derniers réglages41...
Vérifications Finales42...................
Utilisation
Informations de Sécurité44...............
Mise en Marche du Four45...............
Combi-Four/ étuve à Vapeur
Contrôles Standards46..................
Combi-Four/étuve à Vapeur Cuisson et
Pause en Option48......................
Combi-Convection/étuve à Vapeur
Contrôles Standards52..................
Combi-Four à Convection Contrôles
Standards53...........................
Combi-Four à Convection
Cuisson et Pause en Option54...........
Sonde à Viande en Option58.............
Entretien
Procédé de fonctionnement de
la bouteille vaporisatrice59...............
Entretien Préventif et Nettoyage60........
Détartrage61...........................
Introduction
The Blodgett Combi Cooking Line
For quite some time, commercial cooking equipment has remained more or less unchanged.
There a re k ettles, deck ovens, the good old range
with its legion of pots and many other extra
appliances. The result: time expenditure, excessive manual work, and countless cleaning processes. The last few years have paved the w ay for
a revolution in the equipment of restaurant and institutional kitchens. Blodgett Combi is proud to offer three different cooking platforms, one of which
is sure to match your needs. The B lodgett Combi
line includes:
D
The Blodgett Combi Convection Steamer
D
The Blodgett Combi Convection Oven
D
The Blodgett Combi-Oven/Steamer
All Blodgett Combi appliances improve your kitchen through:
D
increased productivity
D
a wider range of menu choices
D
a simplified cleaning process
The work process is simplified since products are
prepared on or in steam table pans and trays.
Food can be cooked, stored, and transported with
the same pans. Small amounts of product can be
processed efficiently; pre-cooked and convenience foods can be reheated within minutes.
COMBI CONVECTION OVEN
Cooking in the Combi Convection Oven differs
from cooking in a traditional deck or range oven
since heated air is constantly recirculated over the
product by a fan in an enclosed chamber. The
moving air continually strips away the layer of cool
air surrounding the product, quickly allowing the
heat to penetrate. The result is a high quality product, cooked at a lower temperature in a shorter
amount of time.
COMBI-OVEN/STEAMER
With the Oven/Steamer you have the choice of two
cooking processes: Steam and Hot Air, either...
D
Separately
D
Combined, or
D
In Sequence using two or three functionsduring
one cooking process. We call this combi-steaming and combi-baking.
For easy operation you can choose from three
modes:
SteamHotAirCombi
Steam &
Hot Air
In the Steam mode you can:
COMBI CONVECTION STEAMER
Steaming is a well known cooking process frequently used in restaurant and institutional kitchens. With the Combi Convection Steamer,it is now
possible to enjoy the many advantages of steaming including shorter cook times, higher product
quality and vitamin retention.
The Combi Convection Steamer includes a built in
steam generator. This unit includes an inlet, funnel
assembly and valve lever for decalcification.
D
steam
D
defrost
D
blanch
D
rethermalize
D
poach
IntheHotAirmodeyoucan
D
roast
D
bake
D
braise
In the Combi mode you can:
D
defrost
D
reheat
D
proof*
D
roast
D
bake
D
cook & hold*
D
rethermalize
D
sous vide*
* with optional digital controls
The Combi-Oven/Steamer is offered in two models,
each with different steam producing systems.
D
The COS-20G model includes a built in steam
generator. This unit includes an inlet, funnel assembly and valve lever for decalcification.
D
The COS-20GDS is a direct steam unit that is
connected to an external steam source.
2
Introduction
Description of the Blodgett Combi Cooking Line
ABOUT THE COMBI LINE
Blodgett Combi appliances are quality produced
using high-grade stainless steel with first class
workmanship.
The use of high quality insulation impedes excessive heat radiation and saves energy.
Oven/Steamers and Convection Steamers
The high performance steam control system
makes it possible to enjoy all of the advantages of
a high quality steamer at the flick of a switch. Fresh
steam enters the oven cavity without pressure and
is circulated at high speed. This process enables
quick and gentle cooking and ensures high quality
product while providing convenient working methods.
A patented quench system keeps the air in the unit
clean. Fumes are extracted from the appliance,
quenched, and directed out through the condenser drain. The exhaust system is effective in all
cooking modes and results in better quality foods
and no flavor transfer. The fan, which is guarded
against accidental finger contact, is driven by a
quiet and powerful motor. The condenser draws
out excess steam from the appliance. Condensation and waste water, which result during steaming and cleaning, are continuously drained.
OPERATION
The practical oven door, with a viewing window,
has a wide swing radius and handle which can be
operated easily, even with wet or greasy hands.
Ease of operation is guaranteed through the simple arrangement of the controls. Graphic symbols
make the appliances easy for even inexperienced
kitchen staff to operate. All modes can be selected
with one switch. This includes the Cool Down
mode, which allows the oven cavity to cool down
rapidly with the door opened or closed.
Cleaning is kept to a minimum. The interior can be
sprayed with a cleaning solution to easily remove
crusts and stains. The oven is designed for easy
care and is welded water tight so that the internal
cooking cavity may be rinsed with a hose after the
cleaning process.
3
Introduction
Oven Features
4
Standard Features
5
6
1
Control Panel
2Oven Door
3Door Handle
4Vent (not shown)
2
3
1
COS-20G Shown
Figure 1
5Decalcifying Inlet & Funnel Assembly*
6Decalcifying Valve Lever*
* only on COS-20G and BCS-20G
4
Installation
Owner’s Responsibilities
1. Oven(s) are uncrated and put in place.
2. The owner/operator must have the following
plumbingand electricalrequirements met and
installed.
NOTE: Refer to the Utility Connection infor-
mation provided.
ELECTRICAL
30 amp Nema L5-30 grounded outlet
PLUMBING
Water
Water Pressure (min/max)50 PSI (345 kPa) to unit
Cold Water Supply3/4” Hose Fitting, 3/8 ID hose minimum
Hot Water Supply*3/4” Hose Fitting, 3/8 ID hose minimum*
DrainageAtmospheric Vented Drain
Drain Connection2” Copper
Avg Water Drain Temp.Approximately 122_F(50_C)
ation service or maintenance can cause
property damage, injury or death. Read
the installation, operation and maintenance instruction thoroughly before installing or servicing this equipment.
GAS PRESSURE
Orifice at Sea Level
Steam#K (.281” dia) natural gas
Hot Air#44 (. 086“ dia) natural gas
The well planned and proper placement of your
appliance will result in long term operator convenience and satisfactory performance.
The following clearances must be maintained between the unit and any combustible or non-combustible construction.
D
Right s ide of unit --- 6” (15 cm)
D
Left side of unit --- 6” (15 cm)
D
Back of unit --- 6” (15 cm)
NOTE: For models with hose assemblies on the
back of the unit, the hose must be 6” (15
cm) from the wall.
The following clearances are recommended, but
not required, for servicing.
D
Left side of unit --- 12” (30 cm)
D
Back of unit --- 12” (30 cm)
Place the unit in an area which is free of drafts and
accessible for proper operation and servicing.
Keep the operating area free and clear of all combustibles such as paper, cardboard, and flammable liquids and solvents.
DO NOT place the unit on a curb base or seal to
the wall; either condition will prevent proper ventilationto the blowermotors.Slight unevenness can
be corrected with the adjustable legs.
Heat sources should not be located near the air
vents on the left hand side of the unit. Consult the
factory for an optional protective side heat shield
kit if a warm surface or water source is to the left
of the unit.
On all models, tripping the blower motor’s thermal
overload device indicates an excessive ambient
temperature on the side of the oven. This must be
corrected to prevent permanent damage to the
oven. All motor bearings are permanently lubricated by the manufacturer; there is no need for
additional lubrication during the operational lifetime of the motors.
VENTILATION
The necessity for a properly designed and installed ventilation system cannot be over emphasized. The ventilation system will allow the unit to
function properly while removing unwanted vapors and products of combustion from the operat ing area.
The appliance must be vented with a properly designed mechanically driven exhaust hood. The
hood should be sized to completely cover the
equipment plus an overhang of at least 6” (15 cm)
on all sides not adjacent to a wall. The capacity of
the hood should be sized appropriately and provisions made for adequate makeup air.
WARNING!!
Failure to properly vent the oven can be
hazardous to the health of the operator;
and will result in operational problems,
unsatisfactorybaking, and possible damage to the equipment. Damage sustained
as a direct result of improper ventilation
will not be covered by the Manufacturer’s
warranty.
U.S. and Canadian Installations
Refer to your local ventilation codes. In the absence of local codes, refer to the National ventilation code titled, “Standard for the Installation of
Equipment for the Removal of Smoke and Grease
Laden Vapors from Commercial Cooking Equipment”, NFPA-96- Latest Edition.
General Export Installations
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installationand/or
operation of your unit, please contact your local
distributor. If you do not have a local distributor,
please call Blodgett Combi at 0011-802-860-3700.
6
Installation
Agency Approvals
THEINSTALLATIONINSTRUCTIONSCONTAINED HEREIN ARE FOR THE USE OF QUALIFIED INSTALLATIONAND SERVICE PERSONNEL
ONLY. INSTALLATION OR SERVICE B Y OTHER
THAN QUALIFIED PERSONNEL MAY RESULT IN
DAMAGE TO THE OVEN A ND/ OR INJURY TO
THE OPERATOR.
Qualified installation personnel are individuals, a
firm, a corporation, or a company which either in
person or through a representative are engaged
in, and are responsible for:
D
The installation or replacement of gas piping.
The connection, installation, repair or servicing
of equipment.
D
The installation of electrical wiring from the electric meter, main control box or service outlet to
the electric appliance.
Qualified installation personnel must be experiencedinsuchwork,befamiliarwithallprecautions required and have complied with all requirements of state or local authorities having
jurisdiction.
U.S. and Canadian Installations
Installation must conform with local codes, or in
the absence of local codes, with the National Fuel
Gas Code, NFPA54/ANSI Z223.1 ---Latest Edition,
the Natural Gas Installation Code CAN/CGAB149.1 or the Propane Installation Code, CAN/
CGA-B149.2 as applicable.
Reference: National Electrical Code, ANSI/NFPA
70---Latest Edition and/or CanadianElectrical
Code CSA C22.1 as applicable.
This equipment is to be installed in compliance
with the Basic Plumbing Code of the Building Offi-
cials and Code Administrators International Inc.
(BOCA) and the Food Service Sanitation Manual of
the Food and Drug Administration (FDA).
General Export Installations
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installationand/or
operation of your unit, please contact your local
distributor. If you do not have a local distributor,
please call Blodgett Combi at 0011-802-860-3700.
7
Installation
Utility Connections
WATER CONNECTION
NOTE: Hot water maximizes steam production
but is not required. Cold water may be
supplied to both inlets if hot water is not
available.
COS-20G and BCS -20G --- C on n e c t th e ap pliance to quality cold water via a pressure hose
with 3/4” (1/9 cm) couplings. Cold water is connected to the left solenoid/pressure regulator as
views from the rear of the oven. Hot water connec tion, right solenoid/pressure regulator, to the boiler is recommended. A shut off valve must be provided adjacent to the oven.
COS-20GDS and CNV-20E --- Connect the units
to quality cold w ater via a pressure hose with 3/4”
(1/9 cm) couplings.
DRAIN CONNECTION
A 2” (5 cm) copper pipe with standard drain pitch
mustberuntoanopendrainorconnectedtoa
standpipe equipped with a vent.
NOTE: Thewastewatercanalsobedirectedtoa
nearby floor drain. Flexible hose which allows trapped water to accumulate in
sagged runs must be avoided.
1. Find the drain connection on the lower rear of
the unit.
2. Loosen the coupling clamps. Attach a 2” (5
cm) copper drain pipe to the drain connection.
Retighten the coupling clamps.
NOTE: The open end of the drain should be in-
stalled facing the floor. Copper line, used
for installation to an open drain or floor
sink, must be supplied by theinstaller. Use
of a trap inline will cause drain backup.
1/2” Appliance Hose
With 3/4” Hose Fittings
Figure 2
Water must meet the following minimum requirements:
D
Total Dissolved Solids (TDS) content will not exceed 30 parts per million.
D
WaterPHmustbe7.0orhigher
WARNING!!
The use of poor quality water will invali-
date your warranty.
Oven
Drain
2” Drain
Customer
Supplied
To Dr ain
Figure 3
STEAM CONNECTION
NOTE: COS-20G direct steam units only .
Connect the appliance to a 200 psi maximum external steam source per local or state codes. The
steam must be clean, potable and fit for human
consumption. Failure to connect this appliance to
a suitable steam source will revoke the approval of
NSF.
8
Installation
Utility Connections
ELECTRICAL CONNECTION
Before making any electricalconnections to these
units, check that the power supply is adequate for
the voltage, amperage, and phase requirements
stated on the rating name plate mounted on the
right side of the unit.
Wiring diagrams are located on the inside of the
louvered side panel.
WARNING!!
This appliance is equipped with a 125V
three-prong (grounding) locking plug for
your protection against shock hazardand
shouldbe plugged directlyinto a properly
grounded three-prong receptacle. DO
NOT cut or remove the grounding prong
from this plug.
NOTE: DISCONNECT THE POWER SUPPLY TO
THEUNITBEFORESERVICING!
U.S. and Canadian installation
All units, when installed, must be electrically
grounded in accordance with local codes or in the
absence of localcodes, w ith the National Electrical
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installationand/or
operation of your unit, please contact your local
distributor. If you do not have a local distributor,
please call Blodgett Combi at 0011-802-860-3700.
NOTE: ALL MANUAL RESETS SHOULD BE RE-
STORED BEFORE CONNECTING POWER
TO THE APPLIANCE.
WARNING!!
Improper electrical installation will invali-
date your warranty.
9
Installation
L
t
h
p
g
Utility Connections
GAS PIPING
A properly sized gas supply system is essential for
maximum oven performance. Piping should be
sized to provide a supply of gas sufficient to meet
the maximum demand of all appliances on the line
without loss of pressure at the equipment.
Example:
NOTE: BTU values in the following example are
for natural gas.
You purchase a COS-20G to add to your existing
cook line.
1. Add the BTU rating of your currentappliances.
Pitco Fryer120,000 BTU
2. Add the BTU rating of the new oven to the total.
Previous Total230,000 BTU
COS-20G (for hot air)225,000 BTU
New Total455,000 BTU
3. Measure the distance from the gas meter to
the cook line. This is the pipe length. Let’s say
thepipelengthis20’(6m)andthepipesize
is 1” (2.54 cm).
4. Use the appropriate table to determine the total capacity of your current gas piping.
The total capacity for this example is 465,000
BTU. Since the total required gas pressure,
455,000 BTU is less than 465,000 BTU, the
current gas piping will not have to be increased.
NOTE: The BTU capacities given in the tables are
for straight pipe lengths only. Any elbows
or other fittings will decrease pipe capacities. For example: a schedule 40 1/2” ell
fitting has an equivalent cpapacity of 4.2”
(10.2 cm) of straight pipe. Contact your local gas supplier if you have any questions.
The gas pressure to the appliance must be rated
for 7” W.C. for natural gas and 14” W.C. for propane gas for each unit while the burners are on. A
sufficient gas pressure must be present at the inlet
to satisfy these conditions.
Each unit has been adjusted at the factory to operate with the type of gas specified on the rating
plate attached to the right side of the unit.
Each oven is supplied with a regulator to maintain
thepropergaspressure.The regul ator is essen-
tial to the proper operation of the oven and
shouldnot be removed. It is preset to provide the
oven with 3.5” W.C. (0.87 kPa) for natural gas and
10.0” W.C. (2.50 kPa) for Propane while the flame
is on.
DO NOT INSTALL AN ADDITIONAL REGULATOR
WHERE THE OVEN CONNECTS TO THE GAS
SUPPLY UNLESS THE INLET PRESSURE IS
GREATER THAN 14” W.C. (1/2 PSI).
The oven and its individual shutoff valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressuresinexcessof1/2psig(3.45kPa).
The oven must be isolated from t he gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the
gas piping system at test pressures equal or less
than 1/2 psig (3.45kPa).
Prior to connecting the unit, gas lines should be
thoroughly purged of all metal filings, shavings,
pipe dope, and other debris. After connection, the
unit s hould be checked for correct gas pressure.
U.S. and Canadian installations
Installation must conform with local codes, or in
the absence of local codes, with the National Fuel
Gas Code, NFPA54/ANSI Z223.1 ---Latest Edition,
the Natural Gas Installation Code CAN/CGAB149.1 or the Propane Installation Code, CAN/
CGA-B149.2 as applicable.
General Export Installations
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installationand/or
operation of your unit, please contact your local
distributor. If you do not have a local distributor,
please call Blodgett Combi at 0011-802-860-3700.
11
Installation
Final Check and Adjustments
BEFORE SWITCHING THE APPLIANCE ON
Before applying power to the unit for the first time,
check for the following conditions:
j
The unit is level.
j
All electrical safety provisions have been adhered to and the electrical connections are
correct.
j
The circulation blower w h eels should turn
counter-clockw ise: check rotation from inside
the oven cavity.
j
Water is connected, turned on and all of the
connections are water tight.
j
Check gas fittings with leak detectionsolution.
j
The transport cart is inserted into the cooking
cavity. When the cart is not inserted into the unit,
water can spill onto the floor causing it to become slippery. If the door will not close properly,
use the foll owing adjustment procedure.
NOTE: COS-20G and BCS-20G units only --- T h e
first time the unit is turned on, or after the
unit has been OFF for 5 hours and then
turned on, it will automatically flush the
steam generator for a period of 75 seconds. The steam generator will then fill to
the proper water level. The unit is now
ready for operation.
DOOR ADJUSTMENT
The hinges may be adjusted using the following
procedure:
1. Adjust the top hinge plate by loosening the
three mounting bolts on the top right corner of
the unit.
2. Adjust the bottom hinge pin by loosening the
mounting bolt located under the bottom hinge
plateonthelowerrightcorneroftheoven.
3. Adjust the hinges so that the door back and
the unit face are parallel.
4. Tighten the bolts so that there is no further
movement.
5. The adjustment is correct when the door
closes firmly and no steam leaks from the gasket.
The hinges can also be adjusted as follows:
1. Adjust the door catch by loosening the four
mounting screw s located on the inside surface of the oven door.
2. The adjustment is correct when no steam
leaks from the gasket.
COS-20G Shown
Oven
Door
Oven
Door
Figure 4
12
Installation
Final Check Lists
ELECTRICAL CONTROL COMPARTMENT
j
Remove side panel
j
Set motor protectors (F2) to on position
j
Adjust motor protectors to 3 amps
j
Reset high limit thermostats F3 and F6
j
Reinstall side panel
PLUMBING FINAL CHECK
j
Incoming water pressure within 50 PSI (minimum)
j
Water solenoids are properly bracketed and
not leaking
j
Atmospheric vented drain in place
j
Water feed lines intact without leaks
j
Spray hose connected properly
Washer
Regulator Assembly
“Y” Fitting
Cold water supply
Fill
Solenoid
Washer
Hose and Spray
Spray Hose Connection
OVEN OPERATIONAL TESTS
NOTE: Checkstobemadebycustomerorautho-
rized service agent.
Cool Down Mode (if applicable)
j
Turn to COOL DOWN position and verify that
the motor operates with the door open.
Combi Mode (if applicable)
Turn to COMBI mode, set thermostat to 350_F
(177_C) and verify:
j
Steam generator flushes a nd fills (COS-20G
only)
j
Steam generator preheats to 175_F(79_C)
then switches to hot air (COS-20G only)
j
When hot air reaches 350_F (177_C) hot air
shuts off and steam comes on
Steam Mode (if applicable)
Remove control panel, turn to STEAM mode and
verify:
j
Check timer operation in both positions
1. Set timer in position other than ON, timer
should count down
2. Set timer in ON position, oven should operate continuously without timer
j
Run light (power light) turns on
j
Unit produces steam, window fogs, door seal
does not leak
j
Quenching system working
Figure 5
GAS FINAL CHECK
j
Inlet pressure verified at 7---14” W.C. for Natural Gas or 12---14” W.C. for Propane gas.
j
Manifold pressure verified at 3.5” W.C. for Natural Ga s or 10.0” W.C. for Propane gas.
j
Gas line properly secured.
j
Check for leaks using leak detection solution.
Hot Air Mode (if applicable)
Turn to HOT AIR mode and set thermostat to
400_F (205_C) and verify:
j
Heat demand light is on
j
Oven is heating properly
j
Heat lights shuts off at 400_F (205_C) and
oven maintains 400_F (205_C)
13
Operation
Safety Information
THE INFORMATION CONTAINED IN THIS SECTION IS PROVIDED FOR THE USE OFQUALIFIED
OPERATING PERSONNEL. QUALIFIED OPERATING PERSONNEL ARE THOSE WHO HAVE
CAREFULLY READ THE INFORMATION CONTAINED IN THIS MANUAL, ARE FAMILIAR WITH
THE FUNCTIONS OF THE OVEN A ND/OR HAVE
HAD PREVIOUS EXPERIENCE WITH THE OPERATIONOF THE EQUIPMENT DESCRIBED. AD HERENCE TO THE PROCEDURES RECOMMENDEDHEREINWILLASSURETHE
ACHIEVEMENT OF OPTIMUM PERFORMANCE
AND LONG, TROUBLE-FREE SERVICE.
Please take the time to read the following safety
and operating instructions. They are the key to the
successful operation of your Blodgett Combi gas
appliance.
SAFETY TIPS
For your sa fety read before operating
What to do if you smell gas:
D
DO NOT try to light a ny appliance.
D
DO NOT touch any electrical switches.
D
Use an exterior phone to call your gas supplier
immediately.
D
If you cannot reach your gas supplier, call the
fire department.
What to do in the event of a power failure:
D
Turn all sw itche s to off.
D
DO NOT attempt to operate the unit until the
power is restored.
NOTE: In the event of a shut-down of any kind, al-
low a five (5) minute shut off period before
attempting to restart the oven.
General safety tips:
D
DO NOT use tools to turn off the gas control. If
the gas cannot be turned off manually do not try
to repair it. Call a qualified service technician.
D
If the oven needs to be moved for any reason,
the gas must be turned off and disconnected
from the unit before removing the restraint
cable. Reconnect the restraint after the oven
has been returned to its original location.
D
DO NOT remove the control panel cover unless
the oven is unplugged.
14
Operation
Oven Start-Up
INITIAL OVEN START-UP
1. TurnthemanualgasvalvetoON.
STEAM MODE (if applicable)
NOTE: For direct steam units, skip steps 4 ---6.
1. TurnthemodeselectorswitchtoSTEAM.
2. Thecombustionblowerturnson.
3. The green POWER Indicator lamp on the front
control panel lights.
4. The steam generator flushes and drains automaticallyfor 75 seconds if the unit has been off
for at least 5 hours.
5. The steam generator begins to fill. After two
minutes, the FILL indicator lamp on the front
control panel blinks. The convection blower
and POWER lamp turn off.
6. When the steam generator is filled to the proper
level and preheated, the convection blower, interior lights and POWER indicator lamp turn on.
7. Several relay contacts change state. A click is
heard when the gas valve opens.
8. The steam generator main burner ignites.
9. Steam fills the cavity and is controlled by a
non-accessible internal thermostat.
HOT AIR MODE (if applicable)
1. TurnthemodeselectorswitchtoHotAir.
2. Theconvectionblowerturnson.
3. Set the hot air thermostat to the desired temperature.
4. The thermostat lamp lights, indicating the cavity temperature is below the desired set point.
5. Twoseriesofclicksareaudibleasthehotair
pilot burners and main burners ignite.
6. When the cavity temperature reaches the desired set point, the temperature indicator lamp
goes off. The main burners shut off.
COMBI MODE (if applicable)
NOTE: For direct steam units, skip steps 5 ---8.
1. TurnthemodeselectorswitchtoCOMBI.
2. Thecombustionblowerturnson.
3. The green POWER indicator lamp on the front
control panel lights.
4. Set the Hot A ir thermostat to the desired temperature.
5. The steam generator flushes and drain automaticallyfor 75 seconds if the unit has been off
for at least 5 hours.
6. The steam generator begins to fill. After two
minutes the FILL indicator lamp on the front
control panel blinks. The convection blower
and POWER lamp do not shut down.
7. When the steam generator is filled to the proper level, several relay contacts change state.
A click is heard when the gas valve opens.
8. When the steam generator comes up to a predetermined temperature, the hot air t hermostat lamp illuminates, indicating the cavity
temperature is below the desired set point.
9. Twoseriesofclicksareaudibleasthehotair
pilot burners and main burners ignite.
10. When the cavity temperature reaches the desired set point, the temperature indicator lamp
goes off. The main burners shut off.
11. The steam and hot air burners toggle back
and forth responding to the thermostat set
points.
15
Operation
Combi-Oven/Steamer Standard Controls
CONTROLS IDENTIFICATION
1. LOW WATER FILL LIGHT --- d u r i n g t h e f i l l
2
1
4
5
7
3
2. DON’T STEAM LIGHT --- indicates the unit is
3. POWER ON LIGHT --- indicates the unit is in
6
4. MODE SELECTOR SWITCH --- tu r n s p o w e r
5. TEMPERATURE DIAL --- used to set desired
6. HEATING INDICATOR LIGHT --- l i gh t s w h e n
7. TIMER DIAL --- used to set desired cooking
8. FLUSH/DRAIN SWITCH --- used to flush/
cycle, this light remains on until the water in
the steam generator is at the proper level and
up to temperature. During normal operation the
light should not be on. If the light comes on,
check the water level in the steam generator.
NOTE: COS-20GDS, the direct steam unit,
does not have a low water fill light.
too hot to operate in the steam mode. Place
the unit in the Cool Down mode until the temperature is below 230_F (110_C) and open the
door. This light does not inhibit steam production.
Steam, Hot Air or Combi.
to the oven on or off. Allows selection of
Steam, Hot Air, Combi or Cool Down modes.
cooking temperature.
the Hot Air heating is in operation.
time.
drain the steam generator for decalcification.
NOTE: COS-20GDS, the direct steam unit,
does not have a flush/drain switch.
8
COS-20G Shown
Figure 6
16
Loading...
+ 46 hidden pages