Blodgett BCS-20G Installation Manual

COS-20G, COS-20GDS, BCS-20G, AND CNV-20G
GAS COOKING APPLIANCES
INSTALLATION -- OPERATION -- MAINTENANCE
COS-20G, COS-20GDS, BCS-20G, ET CNV-20G
APPAREILS DE CUISSON AU GAZ
MANUEL D’INSTALLATION -- FONCTIONNEMENT -- ENTRETIEN
BLODGETT COMBI
www.blodgettcorp.com
PN R9443 Rev C (6/01)
E 2000 --- Blodgett Combi
A PERSONAL WORD FROM BLODGETT COMBI
QUELQUES MOTS DE BLODGETT COMBI
Congratulationson yourpurchase of aBLODGETT Combi appliance.We firmly believe that your choice has been a wise one, and trust you will re­ceive many years of excellent service from your new Combi.
You will find that cooking with Combi appliances saves time, labor and extensive cleaning of both the kitchen and the unit.
With Combi appliances the quality, taste, consistency, and look of your food are improved, thus endorsing the policy to which we’ve always ad­hered: “For Better Cooking!”
Once you’ve had a chance to use your Combi, please t ell us, your dealer and colleagues about any creative and interesting applications you have discovered; exchange ideas with other users. Be sure to advise us or your dealer immediately should any mechanical or technical problems be encountered (...we’re here to help!) and above all “Enjoy Cooking the BLODGETT Combi Way!
For information on cooking, please refer to our separate cooking guide.
Toutes nos félicitations sur votre achat d’appareil de Blodgett Combi. Nous croyons fermement que votre choix est un choix raisonnable et nous sommes certains que vous obtiendrez de nombreuses années d’excellent service de votre nouveau four multi-usages.
Vous allez découvrir que la cuisson dans les appareils Combi économise le temps, le travail et le degré de nettoyage de l’appareil aussi bien que de la cuisine.
Avec les appareil de Combi, la qualité, le goût, la consistence et l’appar­ence des aliments sont améliorés, s’accordant, de ce fait, avec notre politique ”Pour une meilleure cuisson !”
Une fois que vous aurez eu la chance d’utiliser notre Combi, informez nous, votre concessionnaire et vos collègues, de toutes les applications nouvelles et intéressantes que vous avez découvertes ; échangez vos idées avec d’autres utilisateurs. N’hésitez pas à nous prévenir, ou votre concessionnaire, de tout problème mécanique ou technique que vous pourriez rencontrer (... nous sommes ici pour vous aider) et par-dessus tout “Régalez-vous à cuisiner à la façon BLODGETT Combi!
Pour obtenir de plus amples informations sur l’art culinaire, veuillez con ­sulter notre livre de cuisine séparé.
IMPORTANT
WARNIN G:IMPROPER INSTALL ATION, ADJUSTMENT, AL TERATION, SERVICE OR MAINTENAN C E CAN CAUSE PROPERTY DAMAGE,INJURY OR DEATH. READ THE INSTALLA TION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT
AVERTI SSEMEN T: UNE INSTALL ATION, UN AJUSTEMENT, UNE ALTÉRATI ON, UN SERVICE OU UN ENTRETIEN NON CONFORME AUX NORMES PEUT CAUSER DES DOMMAGESÀ LA PROPRIÉTE,DES BLESSURES OU LA MORT. LISEZATTENTIVE­MENT LES DIRECTIVES D’INSTALLATIO N ,D’OPÉRATION ET D’ENTRETI ENAV ANT DE FAIRE L’IN S TALLATI ON OU L’ENTRETIEN DE CET ÉQUIPEMENT.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS MUST BE POSTED IN A PROMINENT LOCATION. THIS INFORMATION MAY BE OBTAINED BY CONTACTING YOUR LOCAL GAS SUPPLIER.
LES INSTRUCTIONS À RESPECTER AU CAS OÙ L’UTILISATEUR PERÇOIT UNE ODEUR DE GAZ DOIVENT ÊTRE AFFICHÉES DANS UN ENDROIT BIEN VISIBLE. VOUS POUVEZ VOUS LES PROCURER AUPRÈS DE VOTRE FOURNISSEUR DE GAZ LOCAL.
FORYOURSAFETY
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
AVERTIS SEMENT
Ne pas entreposer ni utiliser de l’essence ni d’autres vapeurs ou liquides inflam­mables dans le voisinage de cet appariel, ni de tout autre appareil.
The information contained in this manual is i mportant for the proper installation, use, and maintenance of this oven. Adherence to these procedures and instruc­tions will result in satisfactory baking results and long, trouble free service. Please read this manual carefully and retain it for future reference.
Les informatio ns données dans le présent manuel sont importantes pour installer, utiliser et entret en ir correctement ce four. Le respect de ces instructions et procé­dures permettra d’obtenir de bons résultats de cuisson et une longuedurée de ser­vice sans problèmes. Veuillez lire le présent manuel et le conserver pour pouvoir vous y reporter à l’avenir.
Errors: Descriptive, typographic or pictorial errors are subject to correction. Specifica-
tions are subject to change without notice.
Erreurs:Les erreurs de description, de typographie ou d’illustration font l’objet de
corrections. Les caractéristiques sont sujettes à modifications sans préavis.
Your Service Agency’s Address: Adressedevotreagencedeservice:
Model/Modèl:
Serial Number/Numéro de série:
Your oven was installed by/ Installateur de votre four:
Your oven’s installation was checked by/ Contrôleur de l’installation de votre four:
Table of Contents/Table des Matières
Introduction
The Blodgett Combi Cooking Line 2......
Description of the Blodgett Combi
Cooking Line 3.........................
Oven Features 4.......................
Installation
Owner’s Responsibilities 5...............
Location and Ventilation 6...............
Agency Approvals 7....................
Utility Connections 8....................
Final Check and Adjustments 12..........
Final Check Lists 13.....................
Operation
Safety Information 14....................
Oven Start-Up 15........................
Combi-Oven/Steamer
Standard Controls 16....................
Optional Combi-Oven/Steamer
Cook & Hold 18.........................
Convection Steamer Standard Controls 21.
Convection Oven Standard Controls 22....
Optional Convection
Oven Cook and Hold 23..................
Optional Meat Probe 26..................
Maintenance
Spray Bottle Operating Procedure 27......
Cleaning and Preventive Maintenance 28...
Decalcification 29.......................
Introduction
Laligned’appareilsdecuisson
de Blodgett Combi 30....................
Description de la ligne d’appareils de
cuisson de Blodgett Combi 32............
Caractéristiques 33......................
Installation
Responsabilités du propriétaire 34.........
Placement et Ventilation 35..............
Normes et Codes 36.....................
Branchement Utilitaires 37................
Vérification finale et derniers réglages 41...
Vérifications Finales 42...................
Utilisation
Informations de Sécurité 44...............
Mise en Marche du Four 45...............
Combi-Four/ étuve à Vapeur
Contrôles Standards 46..................
Combi-Four/étuve à Vapeur Cuisson et
Pause en Option 48......................
Combi-Convection/étuve à Vapeur
Contrôles Standards 52..................
Combi-Four à Convection Contrôles
Standards 53...........................
Combi-Four à Convection
Cuisson et Pause en Option 54...........
Sonde à Viande en Option 58.............
Entretien
Procédé de fonctionnement de
la bouteille vaporisatrice 59...............
Entretien Préventif et Nettoyage 60........
Détartrage 61...........................
Introduction
The Blodgett Combi Cooking Line
For quite some time, commercial cooking equip­ment has remained more or less unchanged. There a re k ettles, deck ovens, the good old range with its legion of pots and many other extra appliances. The result: time expenditure, exces­sive manual work, and countless cleaning pro­cesses. The last few years have paved the w ay for a revolution in the equipment of restaurant and in­stitutional kitchens. Blodgett Combi is proud to of­fer three different cooking platforms, one of which is sure to match your needs. The B lodgett Combi line includes:
D
The Blodgett Combi Convection Steamer
D
The Blodgett Combi Convection Oven
D
The Blodgett Combi-Oven/Steamer
All Blodgett Combi appliances improve your kitch­en through:
D
increased productivity
D
a wider range of menu choices
D
a simplified cleaning process
The work process is simplified since products are prepared on or in steam table pans and trays. Food can be cooked, stored, and transported with the same pans. Small amounts of product can be processed efficiently; pre-cooked and conve­nience foods can be reheated within minutes.
COMBI CONVECTION OVEN
Cooking in the Combi Convection Oven differs from cooking in a traditional deck or range oven since heated air is constantly recirculated over the product by a fan in an enclosed chamber. The moving air continually strips away the layer of cool air surrounding the product, quickly allowing the heat to penetrate. The result is a high quality prod­uct, cooked at a lower temperature in a shorter amount of time.
COMBI-OVEN/STEAMER
With the Oven/Steamer you have the choice of two cooking processes: Steam and Hot Air, either...
D
Separately
D
Combined, or
D
In Sequence using two or three functionsduring one cooking process. We call this combi-steam­ing and combi-baking.
For easy operation you can choose from three modes:
Steam HotAir Combi
Steam & Hot Air
In the Steam mode you can:
COMBI CONVECTION STEAMER
Steaming is a well known cooking process fre­quently used in restaurant and institutional kitch­ens. With the Combi Convection Steamer,it is now possible to enjoy the many advantages of steam­ing including shorter cook times, higher product quality and vitamin retention.
The Combi Convection Steamer includes a built in steam generator. This unit includes an inlet, funnel assembly and valve lever for decalcification.
D
steam
D
defrost
D
blanch
D
rethermalize
D
poach
IntheHotAirmodeyoucan
D
roast
D
bake
D
braise
In the Combi mode you can:
D
defrost
D
reheat
D
proof*
D
roast
D
bake
D
cook & hold*
D
rethermalize
D
sous vide*
* with optional digital controls
The Combi-Oven/Steamer is offered in two models, each with different steam producing systems.
D
The COS-20G model includes a built in steam generator. This unit includes an inlet, funnel as­sembly and valve lever for decalcification.
D
The COS-20GDS is a direct steam unit that is connected to an external steam source.
2
Introduction
Description of the Blodgett Combi Cooking Line
ABOUT THE COMBI LINE
Blodgett Combi appliances are quality produced using high-grade stainless steel with first class workmanship.
The use of high quality insulation impedes exces­sive heat radiation and saves energy.
Oven/Steamers and Convection Steamers
The high performance steam control system makes it possible to enjoy all of the advantages of a high quality steamer at the flick of a switch. Fresh steam enters the oven cavity without pressure and is circulated at high speed. This process enables quick and gentle cooking and ensures high quality product while providing convenient working meth­ods.
A patented quench system keeps the air in the unit clean. Fumes are extracted from the appliance, quenched, and directed out through the condens­er drain. The exhaust system is effective in all cooking modes and results in better quality foods and no flavor transfer. The fan, which is guarded against accidental finger contact, is driven by a quiet and powerful motor. The condenser draws out excess steam from the appliance. Condensa­tion and waste water, which result during steam­ing and cleaning, are continuously drained.
OPERATION
The practical oven door, with a viewing window, has a wide swing radius and handle which can be operated easily, even with wet or greasy hands.
Ease of operation is guaranteed through the sim­ple arrangement of the controls. Graphic symbols make the appliances easy for even inexperienced kitchen staff to operate. All modes can be selected with one switch. This includes the Cool Down mode, which allows the oven cavity to cool down rapidly with the door opened or closed.
Cleaning is kept to a minimum. The interior can be sprayed with a cleaning solution to easily remove crusts and stains. The oven is designed for easy care and is welded water tight so that the internal cooking cavity may be rinsed with a hose after the cleaning process.
3
Introduction
Oven Features
4
Standard Features
5
6
1
Control Panel
2 Oven Door
3 Door Handle
4 Vent (not shown)
2
3
1
COS-20G Shown
Figure 1
5 Decalcifying Inlet & Funnel Assembly*
6 Decalcifying Valve Lever*
* only on COS-20G and BCS-20G
4
Installation
Owner’s Responsibilities
1. Oven(s) are uncrated and put in place.
2. The owner/operator must have the following plumbingand electricalrequirements met and installed.
NOTE: Refer to the Utility Connection infor-
mation provided.
ELECTRICAL
30 amp Nema L5-30 grounded outlet
PLUMBING
Water
Water Pressure (min/max) 50 PSI (345 kPa) to unit Cold Water Supply 3/4” Hose Fitting, 3/8 ID hose minimum Hot Water Supply* 3/4” Hose Fitting, 3/8 ID hose minimum*
Drainage Atmospheric Vented Drain
Drain Connection 2” Copper Avg Water Drain Temp. Approximately 122_F(50_C)
WARNING!! Improper installation, adjustment, alter-
ation service or maintenance can cause property damage, injury or death. Read the installation, operation and mainte­nance instruction thoroughly before in­stalling or servicing this equipment.
GAS PRESSURE
Orifice at Sea Level
Steam #K (.281” dia) natural gas Hot Air #44 (. 086“ dia) natural gas
Inlet Pressure to the Unit
Natural Gas 7---14” WC (1.74 ---3.48 kPa) Propane 12---14” WC (2.98 ---3.48 kPa)
Pressure at the Manifold
Natural Gas 3.5” WC (.87 kPa) Propane 10” WC (2.49 kPa)
*Not applicable with COS-20GDS and CNV-20G
5
Installation
Location and V entilation
LOCATION
The well planned and proper placement of your appliance will result in long term operator conve­nience and satisfactory performance.
The following clearances must be maintained be­tween the unit and any combustible or non-com­bustible construction.
D
Right s ide of unit --- 6” (15 cm)
D
Left side of unit --- 6” (15 cm)
D
Back of unit --- 6” (15 cm)
NOTE: For models with hose assemblies on the
back of the unit, the hose must be 6” (15
cm) from the wall.
The following clearances are recommended, but not required, for servicing.
D
Left side of unit --- 12” (30 cm)
D
Back of unit --- 12” (30 cm)
Place the unit in an area which is free of drafts and accessible for proper operation and servicing.
Keep the operating area free and clear of all com­bustibles such as paper, cardboard, and flam­mable liquids and solvents.
DO NOT place the unit on a curb base or seal to the wall; either condition will prevent proper venti­lationto the blowermotors.Slight unevenness can be corrected with the adjustable legs.
Heat sources should not be located near the air vents on the left hand side of the unit. Consult the factory for an optional protective side heat shield kit if a warm surface or water source is to the left of the unit.
On all models, tripping the blower motor’s thermal overload device indicates an excessive ambient temperature on the side of the oven. This must be corrected to prevent permanent damage to the oven. All motor bearings are permanently lubri­cated by the manufacturer; there is no need for additional lubrication during the operational life­time of the motors.
VENTILATION
The necessity for a properly designed and in­stalled ventilation system cannot be over empha­sized. The ventilation system will allow the unit to function properly while removing unwanted va­pors and products of combustion from the operat ­ing area.
The appliance must be vented with a properly de­signed mechanically driven exhaust hood. The hood should be sized to completely cover the equipment plus an overhang of at least 6” (15 cm) on all sides not adjacent to a wall. The capacity of the hood should be sized appropriately and provi­sions made for adequate makeup air.
WARNING!! Failure to properly vent the oven can be
hazardous to the health of the operator; and will result in operational problems, unsatisfactorybaking, and possible dam­age to the equipment. Damage sustained as a direct result of improper ventilation will not be covered by the Manufacturer’s warranty.
U.S. and Canadian Installations
Refer to your local ventilation codes. In the ab­sence of local codes, refer to the National ventila­tion code titled, “Standard for the Installation of
Equipment for the Removal of Smoke and Grease Laden Vapors from Commercial Cooking Equip­ment”, NFPA-96- Latest Edition.
General Export Installations
Installation must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installationand/or operation of your unit, please contact your local distributor. If you do not have a local distributor, please call Blodgett Combi at 0011-802-860-3700.
6
Installation
Agency Approvals
THE INSTALLATION INSTRUCTIONS CON­TAINED HEREIN ARE FOR THE USE OF QUALI­FIED INSTALLATIONAND SERVICE PERSONNEL ONLY. INSTALLATION OR SERVICE B Y OTHER THAN QUALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE OVEN A ND/ OR INJURY TO THE OPERATOR.
Qualified installation personnel are individuals, a firm, a corporation, or a company which either in person or through a representative are engaged in, and are responsible for:
D
The installation or replacement of gas piping. The connection, installation, repair or servicing of equipment.
D
The installation of electrical wiring from the elec­tric meter, main control box or service outlet to the electric appliance.
Qualified installation personnel must be experi­encedinsuchwork,befamiliarwithallprecau­tions required and have complied with all require­ments of state or local authorities having jurisdiction.
U.S. and Canadian Installations
Installation must conform with local codes, or in the absence of local codes, with the National Fuel
Gas Code, NFPA54/ANSI Z223.1 ---Latest Edition, the Natural Gas Installation Code CAN/CGA­B149.1 or the Propane Installation Code, CAN/ CGA-B149.2 as applicable.
Reference: National Electrical Code, ANSI/NFPA 70---Latest Edition and/or Canadian Electrical Code CSA C22.1 as applicable.
This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Offi-
cials and Code Administrators International Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
General Export Installations
Installation must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installationand/or operation of your unit, please contact your local distributor. If you do not have a local distributor, please call Blodgett Combi at 0011-802-860-3700.
7
Installation
Utility Connections
WATER CONNECTION
NOTE: Hot water maximizes steam production
but is not required. Cold water may be supplied to both inlets if hot water is not available.
COS-20G and BCS -20G --- C on n e c t th e ap ­pliance to quality cold water via a pressure hose with 3/4” (1/9 cm) couplings. Cold water is con­nected to the left solenoid/pressure regulator as views from the rear of the oven. Hot water connec ­tion, right solenoid/pressure regulator, to the boil­er is recommended. A shut off valve must be pro­vided adjacent to the oven.
COS-20GDS and CNV-20E --- Connect the units to quality cold w ater via a pressure hose with 3/4” (1/9 cm) couplings.
DRAIN CONNECTION
A 2” (5 cm) copper pipe with standard drain pitch mustberuntoanopendrainorconnectedtoa standpipe equipped with a vent.
NOTE: Thewastewatercanalsobedirectedtoa
nearby floor drain. Flexible hose which al­lows trapped water to accumulate in sagged runs must be avoided.
1. Find the drain connection on the lower rear of the unit.
2. Loosen the coupling clamps. Attach a 2” (5 cm) copper drain pipe to the drain connection. Retighten the coupling clamps.
NOTE: The open end of the drain should be in-
stalled facing the floor. Copper line, used for installation to an open drain or floor sink, must be supplied by theinstaller. Use
of a trap inline will cause drain backup.
1/2” Appliance Hose With 3/4” Hose Fittings
Figure 2
Water must meet the following minimum require­ments:
D
Total Dissolved Solids (TDS) content will not ex­ceed 30 parts per million.
D
WaterPHmustbe7.0orhigher
WARNING!! The use of poor quality water will invali-
date your warranty.
Oven
Drain 2” Drain Customer Supplied
To Dr ain
Figure 3
STEAM CONNECTION
NOTE: COS-20G direct steam units only .
Connect the appliance to a 200 psi maximum ex­ternal steam source per local or state codes. The steam must be clean, potable and fit for human consumption. Failure to connect this appliance to a suitable steam source will revoke the approval of NSF.
8
Installation
Utility Connections
ELECTRICAL CONNECTION
Before making any electricalconnections to these units, check that the power supply is adequate for the voltage, amperage, and phase requirements stated on the rating name plate mounted on the right side of the unit.
Wiring diagrams are located on the inside of the louvered side panel.
WARNING!! This appliance is equipped with a 125V
three-prong (grounding) locking plug for your protection against shock hazardand shouldbe plugged directlyinto a properly grounded three-prong receptacle. DO NOT cut or remove the grounding prong from this plug.
NOTE: DISCONNECT THE POWER SUPPLY TO
THEUNITBEFORESERVICING!
U.S. and Canadian installation
All units, when installed, must be electrically grounded in accordance with local codes or in the absence of localcodes, w ith the National Electrical
Code, ANSI/NFPA 70 ---Latest Edition and/or Cana­dian Electrical Code CSA C22.1 as applicable.
General Export Installations
Installation must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installationand/or operation of your unit, please contact your local distributor. If you do not have a local distributor, please call Blodgett Combi at 0011-802-860-3700.
NOTE: ALL MANUAL RESETS SHOULD BE RE-
STORED BEFORE CONNECTING POWER TO THE APPLIANCE.
WARNING!! Improper electrical installation will invali-
date your warranty.
9
Installation
L
t
h
p
g
Utility Connections
GAS PIPING
A properly sized gas supply system is essential for maximum oven performance. Piping should be sized to provide a supply of gas sufficient to meet the maximum demand of all appliances on the line without loss of pressure at the equipment.
Example:
NOTE: BTU values in the following example are
for natural gas.
You purchase a COS-20G to add to your existing cook line.
1. Add the BTU rating of your currentappliances. Pitco Fryer 120,000 BTU
6 Burner Range 60,000 BTU Deck Oven 50,000 BTU Total 230,000 BTU
2. Add the BTU rating of the new oven to the to­tal.
Previous Total 230,000 BTU COS-20G (for hot air) 225,000 BTU New Total 455,000 BTU
3. Measure the distance from the gas meter to the cook line. This is the pipe length. Let’s say thepipelengthis20’(6m)andthepipesize is 1” (2.54 cm).
4. Use the appropriate table to determine the to­tal capacity of your current gas piping.
The total capacity for this example is 465,000 BTU. Since the total required gas pressure, 455,000 BTU is less than 465,000 BTU, the current gas piping will not have to be in­creased.
NOTE: The BTU capacities given in the tables are
for straight pipe lengths only. Any elbows or other fittings will decrease pipe capaci­ties. For example: a schedule 40 1/2” ell fitting has an equivalent cpapacity of 4.2” (10.2 cm) of straight pipe. Contact your lo­cal gas supplier if you have any questions.
Maximum Capacity of Iron Pipe in Cubic Feet
of Natural Gas Per Hour
(Pressure drop of 0.5 Inch W.C.)
Pipe eng
(ft)
10 360 680 1400 2100 3950 20 250 465 950 1460 2750 30 200 375 770 1180 2200 40 170 320 660 990 1900 50 151 285 580 900 1680 60 138 260 530 810 1520 70 125 240 490 750 1400 80 118 220 460 690 1300 90 110 205 430 650 1220
100 103 195 400 620 1150
From the National Fuel Gas Code Part 10 Table 10-2
Maximum Capacity of Pipe in Thousands of
BTU/hr of Undiluted P.P. Gas at 11” W.C.
Pipe Length
From the National Fuel Gas Code Part 10 Table 10-15
3/4” 1” 1-1/4” 1-1/2” 2”
(Pressure drop of 0.5 Inch W.C.)
(ft)
10 608 1146 3525 20 418 788 2423 30 336 632 1946 40 287 541 1665 50 255 480 1476 60 231 435 1337 70 215 404 1241 80 198 372 1144 90 187 351 1079
100 175 330 1014
Nominal Size, Inches
Inside Diameter, Inches
3/4” 1” 1-1/2”
10
Installation
Utility Connections
PRESSURE REGULATION AND TESTING
The gas pressure to the appliance must be rated for 7” W.C. for natural gas and 14” W.C. for pro­pane gas for each unit while the burners are on. A sufficient gas pressure must be present at the inlet to satisfy these conditions.
Each unit has been adjusted at the factory to oper­ate with the type of gas specified on the rating plate attached to the right side of the unit.
Each oven is supplied with a regulator to maintain thepropergaspressure.The regul ator is essen-
tial to the proper operation of the oven and shouldnot be removed. It is preset to provide the
oven with 3.5” W.C. (0.87 kPa) for natural gas and
10.0” W.C. (2.50 kPa) for Propane while the flame is on.
DO NOT INSTALL AN ADDITIONAL REGULATOR WHERE THE OVEN CONNECTS TO THE GAS SUPPLY UNLESS THE INLET PRESSURE IS GREATER THAN 14” W.C. (1/2 PSI).
The oven and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressuresinexcessof1/2psig(3.45kPa).
The oven must be isolated from t he gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas piping system at test pressures equal or less than 1/2 psig (3.45kPa).
Prior to connecting the unit, gas lines should be thoroughly purged of all metal filings, shavings, pipe dope, and other debris. After connection, the unit s hould be checked for correct gas pressure.
U.S. and Canadian installations
Installation must conform with local codes, or in the absence of local codes, with the National Fuel
Gas Code, NFPA54/ANSI Z223.1 ---Latest Edition, the Natural Gas Installation Code CAN/CGA­B149.1 or the Propane Installation Code, CAN/ CGA-B149.2 as applicable.
General Export Installations
Installation must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installationand/or operation of your unit, please contact your local distributor. If you do not have a local distributor, please call Blodgett Combi at 0011-802-860-3700.
11
Installation
Final Check and Adjustments
BEFORE SWITCHING THE APPLIANCE ON
Before applying power to the unit for the first time, check for the following conditions:
j
The unit is level.
j
All electrical safety provisions have been ad­hered to and the electrical connections are correct.
j
The circulation blower w h eels should turn counter-clockw ise: check rotation from inside the oven cavity.
j
Water is connected, turned on and all of the connections are water tight.
j
Check gas fittings with leak detectionsolution.
j
The transport cart is inserted into the cooking cavity. When the cart is not inserted into the unit, water can spill onto the floor causing it to be­come slippery. If the door will not close properly, use the foll owing adjustment procedure.
NOTE: COS-20G and BCS-20G units only --- T h e
first time the unit is turned on, or after the unit has been OFF for 5 hours and then turned on, it will automatically flush the steam generator for a period of 75 sec­onds. The steam generator will then fill to the proper water level. The unit is now ready for operation.
DOOR ADJUSTMENT
The hinges may be adjusted using the following procedure:
1. Adjust the top hinge plate by loosening the three mounting bolts on the top right corner of the unit.
2. Adjust the bottom hinge pin by loosening the mounting bolt located under the bottom hinge plateonthelowerrightcorneroftheoven.
3. Adjust the hinges so that the door back and the unit face are parallel.
4. Tighten the bolts so that there is no further movement.
5. The adjustment is correct when the door closes firmly and no steam leaks from the gas­ket.
The hinges can also be adjusted as follows:
1. Adjust the door catch by loosening the four mounting screw s located on the inside sur­face of the oven door.
2. The adjustment is correct when no steam leaks from the gasket.
COS-20G Shown
Oven
Door
Oven
Door
Figure 4
12
Installation
Final Check Lists
ELECTRICAL CONTROL COMPARTMENT
j
Remove side panel
j
Set motor protectors (F2) to on position
j
Adjust motor protectors to 3 amps
j
Reset high limit thermostats F3 and F6
j
Reinstall side panel
PLUMBING FINAL CHECK
j
Incoming water pressure within 50 PSI (mini­mum)
j
Water solenoids are properly bracketed and not leaking
j
Atmospheric vented drain in place
j
Water feed lines intact without leaks
j
Spray hose connected properly
Washer
Regulator Assembly
“Y” Fitting
Cold water supply
Fill
Solenoid
Washer
Hose and Spray
Spray Hose Connection
OVEN OPERATIONAL TESTS
NOTE: Checkstobemadebycustomerorautho-
rized service agent.
Cool Down Mode (if applicable)
j
Turn to COOL DOWN position and verify that the motor operates with the door open.
Combi Mode (if applicable)
Turn to COMBI mode, set thermostat to 350_F (177_C) and verify:
j
Steam generator flushes a nd fills (COS-20G only)
j
Steam generator preheats to 175_F(79_C) then switches to hot air (COS-20G only)
j
When hot air reaches 350_F (177_C) hot air shuts off and steam comes on
Steam Mode (if applicable)
Remove control panel, turn to STEAM mode and verify:
j
Check timer operation in both positions
1. Set timer in position other than ON, timer should count down
2. Set timer in ON position, oven should op­erate continuously without timer
j
Run light (power light) turns on
j
Unit produces steam, window fogs, door seal does not leak
j
Quenching system working
Figure 5
GAS FINAL CHECK
j
Inlet pressure verified at 7---14” W.C. for Natu­ral Gas or 12---14” W.C. for Propane gas.
j
Manifold pressure verified at 3.5” W.C. for Nat­ural Ga s or 10.0” W.C. for Propane gas.
j
Gas line properly secured.
j
Check for leaks using leak detection solution.
Hot Air Mode (if applicable)
Turn to HOT AIR mode and set thermostat to 400_F (205_C) and verify:
j
Heat demand light is on
j
Oven is heating properly
j
Heat lights shuts off at 400_F (205_C) and oven maintains 400_F (205_C)
13
Operation
Safety Information
THE INFORMATION CONTAINED IN THIS SEC­TION IS PROVIDED FOR THE USE OFQUALIFIED OPERATING PERSONNEL. QUALIFIED OPERAT­ING PERSONNEL ARE THOSE WHO HAVE CAREFULLY READ THE INFORMATION CON­TAINED IN THIS MANUAL, ARE FAMILIAR WITH THE FUNCTIONS OF THE OVEN A ND/OR HAVE HAD PREVIOUS EXPERIENCE WITH THE OP­ERATIONOF THE EQUIPMENT DESCRIBED. AD ­HERENCE TO THE PROCEDURES RECOM­MENDED HEREIN WILL ASSURE THE ACHIEVEMENT OF OPTIMUM PERFORMANCE AND LONG, TROUBLE-FREE SERVICE.
Please take the time to read the following safety and operating instructions. They are the key to the successful operation of your Blodgett Combi gas appliance.
SAFETY TIPS For your sa fety read before operating
What to do if you smell gas:
D
DO NOT try to light a ny appliance.
D
DO NOT touch any electrical switches.
D
Use an exterior phone to call your gas supplier immediately.
D
If you cannot reach your gas supplier, call the fire department.
What to do in the event of a power failure:
D
Turn all sw itche s to off.
D
DO NOT attempt to operate the unit until the power is restored.
NOTE: In the event of a shut-down of any kind, al-
low a five (5) minute shut off period before attempting to restart the oven.
General safety tips:
D
DO NOT use tools to turn off the gas control. If the gas cannot be turned off manually do not try to repair it. Call a qualified service technician.
D
If the oven needs to be moved for any reason, the gas must be turned off and disconnected from the unit before removing the restraint cable. Reconnect the restraint after the oven has been returned to its original location.
D
DO NOT remove the control panel cover unless the oven is unplugged.
14
Operation
Oven Start-Up
INITIAL OVEN START-UP
1. TurnthemanualgasvalvetoON.
STEAM MODE (if applicable)
NOTE: For direct steam units, skip steps 4 ---6.
1. TurnthemodeselectorswitchtoSTEAM.
2. Thecombustionblowerturnson.
3. The green POWER Indicator lamp on the front control panel lights.
4. The steam generator flushes and drains auto­maticallyfor 75 seconds if the unit has been off for at least 5 hours.
5. The steam generator begins to fill. After two minutes, the FILL indicator lamp on the front control panel blinks. The convection blower and POWER lamp turn off.
6. When the steam generator is filled to the proper level and preheated, the convection blower, in­terior lights and POWER indicator lamp turn on.
7. Several relay contacts change state. A click is heard when the gas valve opens.
8. The steam generator main burner ignites.
9. Steam fills the cavity and is controlled by a non-accessible internal thermostat.
HOT AIR MODE (if applicable)
1. TurnthemodeselectorswitchtoHotAir.
2. Theconvectionblowerturnson.
3. Set the hot air thermostat to the desired tem­perature.
4. The thermostat lamp lights, indicating the cav­ity temperature is below the desired set point.
5. Twoseriesofclicksareaudibleasthehotair pilot burners and main burners ignite.
6. When the cavity temperature reaches the de­sired set point, the temperature indicator lamp goes off. The main burners shut off.
COMBI MODE (if applicable)
NOTE: For direct steam units, skip steps 5 ---8.
1. TurnthemodeselectorswitchtoCOMBI.
2. Thecombustionblowerturnson.
3. The green POWER indicator lamp on the front control panel lights.
4. Set the Hot A ir thermostat to the desired tem­perature.
5. The steam generator flushes and drain auto­maticallyfor 75 seconds if the unit has been off for at least 5 hours.
6. The steam generator begins to fill. After two minutes the FILL indicator lamp on the front control panel blinks. The convection blower and POWER lamp do not shut down.
7. When the steam generator is filled to the prop­er level, several relay contacts change state. A click is heard when the gas valve opens.
8. When the steam generator comes up to a pre­determined temperature, the hot air t hermo­stat lamp illuminates, indicating the cavity temperature is below the desired set point.
9. Twoseriesofclicksareaudibleasthehotair pilot burners and main burners ignite.
10. When the cavity temperature reaches the de­sired set point, the temperature indicator lamp goes off. The main burners shut off.
11. The steam and hot air burners toggle back and forth responding to the thermostat set points.
15
Operation
Combi-Oven/Steamer Standard Controls
CONTROLS IDENTIFICATION
1. LOW WATER FILL LIGHT --- d u r i n g t h e f i l l
2
1
4
5
7
3
2. DON’T STEAM LIGHT --- indicates the unit is
3. POWER ON LIGHT --- indicates the unit is in
6
4. MODE SELECTOR SWITCH --- tu r n s p o w e r
5. TEMPERATURE DIAL --- used to set desired
6. HEATING INDICATOR LIGHT --- l i gh t s w h e n
7. TIMER DIAL --- used to set desired cooking
8. FLUSH/DRAIN SWITCH --- used to flush/
cycle, this light remains on until the water in the steam generator is at the proper level and up to temperature. During normal operation the light should not be on. If the light comes on, check the water level in the steam generator.
NOTE: COS-20GDS, the direct steam unit,
does not have a low water fill light.
too hot to operate in the steam mode. Place the unit in the Cool Down mode until the tem­perature is below 230_F (110_C) and open the door. This light does not inhibit steam produc­tion.
Steam, Hot Air or Combi.
to the oven on or off. Allows selection of Steam, Hot Air, Combi or Cool Down modes.
cooking temperature.
the Hot Air heating is in operation.
time.
drain the steam generator for decalcification.
NOTE: COS-20GDS, the direct steam unit,
does not have a flush/drain switch.
8
COS-20G Shown
Figure 6
16
Loading...