Radio interference suppression filter, single-phase
HLE 110-230/4
Advantages
For enhanced requirements
Single-stage filter concept
Efficient filter effect against line-bound interference emissions
Increase in the interference immunity of the connected consumer
Applications
Radio interference suppression filter for line-side interference suppression of
single devices, frequency converters or as group interference suppression.
Sample application
Picture shows HLE 110-230/16
Standards Z
Radio interference suppression filter to DIN EN 60939-2
Approvals Z

Radio interference suppression filter, single-phase
HLE 110-230/4
Type HLE 110-230/4
Operating data
Rated voltage
Voltage range
Rated current
Leakage current (50 Hz)*
Rated frequency
Overrating Capacity
Environment
Ambient temperature max.
Climatic category
Safety and protection
Protection index
Type
Safety class (prepared)
Test voltage
Notes
*
Order numbers
Order Number
250 Vac
0 - 250 Vac
4 A
8.50 mA
50 - 60 Hz
150 %, short-time
50 °C
25/085/21
[in accordance with EN 60068-1]
IP 20
Metal enclosure
I
1700 Vdc Phase/Phase, 2700 Vdc Phase/PE
Leakage current measured against the
maximum permissible input voltage fluctuation in
accordance with IEC 38 ±10 %
HLE 110-230/4
Type HLE 110-230/4
Terminal and mounting
Terminals phase
Terminals PE
Fixing method
Fixing screws
Measures and weights
Weight
Screw clamp, 4 mm²
Bolt, M5
Mounting lugs
M5
0.52 kg