Harmonic filter
HF1K 400
Typ HF1K 7-400 HF1K 13-400 HF1K 18-400 HF1K 24-400 HF1K 30-400 HF1K 50-400
Operating data
Rated voltage 3 x 400 Vac 3 x 400 Vac 3 x 400 Vac 3 x 400 Vac 3 x 400 Vac 3 x 400 Vac
Voltage range 360-440 Vac 360-440 Vac 360-440 Vac 360-440 Vac 360-440 Vac 360-440 Vac
Rated current 3 x 10 A 3 x 19 A 3 x 26 A 3 x 35 A 3 x 43 A 3 x 72 A
THD-I 8 % (nominal load) 8 % (nominal load) 8 % (nominal load) 8 % (nominal load) 8 % (nominal load) 8 % (nominal load)
Rated load power* 5.5 kW 11 kW 15 kW 20 kW 26 kW 45 kW
Description of the load Symmetrical loading by
converters with B6U input
rectifiers
Symmetrical loading by
converters with B6U input
rectifiers
Symmetrical loading by
converters with B6U input
rectifiers
Symmetrical loading by
converters with B6U input
rectifiers
Symmetrical loading by
converters with B6U input
rectifiers
Symmetrical loading by
converters with B6U input
rectifiers
Overrating Capacity 150 % for 60 sec.
every 10 min.
150 % for 60 sec.
every 10 min.
150 % for 60 sec.
every 10 min.
150 % for 60 sec.
every 10 min.
150 % for 60 sec.
every 10 min.
150 % for 60 sec.
every 10 min.
Power loss 90.0 W 160.0 W 180.0 W 230.0 W 290.0 W 412.0 W
Efficiency 99.0 % 99.0 % 99.0 % 99.0 % 99.0 % 99.0 %
Capacitive idle power 1.7 kVAr 1.8 kVAr 2.9 kVAr 3.8 kVAr 4.9 kVAr 10.0 kVAr
Input
Rated frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Approvals
Approvals cURus cURus cURus cURus cURus cURus
Environment
Ambient temperature -10 °C to +45 °C,
without condensation
-10 °C to +45 °C,
without condensation
-10 °C to +45 °C,
without condensation
-10 °C to +45 °C,
without condensation
-10 °C to +45 °C,
without condensation
-10 °C to +45 °C,
without condensation
Type of cooling AN AN AN AN AN AN
MTBF @ 50 °C/500 V (Mil-
HB-217F)
>500.000 h
@ 40°C/400Vac
>500.000 h
@ 40°C/400Vac
>500.000 h
@ 40°C/400Vac
>500.000 h
@ 40°C/400Vac
>500.000 h
@ 40°C/400Vac
>500.000 h
@ 40°C/400Vac
Safety and protection
Type
Open type Open type Open type Open type Open type Open type
Insulation class
H H H H H H
Protection index
IP 00 IP 00 IP 00 IP 00 IP 00 IP 00
Safety class
I I I I I I
Notes
*
IE2 efficiencies of the
motors and an efficiency
>96 % assumed
IE2 efficiencies of the
motors and an efficiency
>96 % assumed
IE2 efficiencies of the
motors and an efficiency
>96 % assumed
IE2 efficiencies of the
motors and an efficiency
>96 % assumed
IE2 efficiencies of the
motors and an efficiency
>96 % assumed
IE2 efficiencies of the
motors and an efficiency
>96 % assumed
Order numbers
Order Number HF1K 7-400 HF1K 13-400 HF1K 18-400 HF1K 24-400 HF1K 30-400 HF1K 50-400
Reactors / EMI filters
Harmonic filters
3
Harmonic filter
HF1K 400
General Data
Rated voltage 3 x 400 Vac
Rated current 3 x 10 - 3 x 144 A
THD-I <8 % in rated operation
Load rated capacity 5.5 - 90 kW
Insulation class H
Ambient temperature -10 °C to +45 °C
Degree of protection IP 00
Advantages
Sinusoidal current consumption from the main in devices with uncontrolled
B6U diode rectifiers
Compliance with EN 61000-3-2, EN 61000-3-12
Support in the compliance with IEEE 519, D-A-CH-CZ
Cos(phi)>0,95 at rated current
Hardly any intermediate circuit voltage dip by comparison with a 4 % uK line
reactor
Harmonic filter with minimum capacitive idle reactive power
Very good corrosion protection and low noise thanks to vacuum
impregnation
Operation at 50 - 60 Hz possible
Use of the HF1K as a central sum filter for multiple converters possible
Applications
Harmonic filter module to ensure sinusoidal main currents, reduction of main
harmonic currents, increase in system service life and system reliability and
compliance with power quality standards such as IEEE 519, TEC 61000-3-2,
IEC 61000-3-12.
StandardsZ
Harmonic filter in accordance with
EN 61558 Part 1, EN 61558 Part 20, UL 508 17th Ed., CSA 22.2 No. 14-10
Subject to change
482
Approvals W J Z
UL 506, CSA 22.2

Reactors / EMI filters
1.1
1.2
5.1
1.3
2.1
2.2
3.1
3.2
3.3
5.2
4.0
Harmonic filters
3
Harmonic filter
HF1K 400
Typ HF1K 7-400 HF1K 13-400 HF1K 18-400 HF1K 24-400 HF1K 30-400 HF1K 50-400
Operating data
Rated voltage 3 x 400 Vac 3 x 400 Vac 3 x 400 Vac 3 x 400 Vac 3 x 400 Vac 3 x 400 Vac
Voltage range 360-440 Vac 360-440 Vac 360-440 Vac 360-440 Vac 360-440 Vac 360-440 Vac
Rated current 3 x 10 A 3 x 19 A 3 x 26 A 3 x 35 A 3 x 43 A 3 x 72 A
THD-I 8 % (nominal load) 8 % (nominal load) 8 % (nominal load) 8 % (nominal load) 8 % (nominal load) 8 % (nominal load)
Rated load power* 5.5 kW 11 kW 15 kW 20 kW 26 kW 45 kW
Description of the load Symmetrical loading by
Overrating Capacity 150 % for 60 sec.
Power loss 90.0 W 160.0 W 180.0 W 230.0 W 290.0 W 412.0 W
Efficiency 99.0 % 99.0 % 99.0 % 99.0 % 99.0 % 99.0 %
Capacitive idle power 1.7 kVAr 1.8 kVAr 2.9 kVAr 3.8 kVAr 4.9 kVAr 10.0 kVAr
converters with B6U input
rectifiers
every 10 min.
Input
Rated frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Approvals
Approvals cURus cURus cURus cURus cURus cURus
Environment
Ambient temperature -10 °C to +45 °C,
Type of cooling AN AN AN AN AN AN
MTBF @ 50 °C/500 V (MilHB-217F)
without condensation
>500.000 h
@ 40°C/400Vac
Safety and protection
Type
Insulation class
Protection index
Safety class
Open type Open type Open type Open type Open type Open type
H H H H H H
IP 00 IP 00 IP 00 IP 00 IP 00 IP 00
I I I I I I
Notes
*
IE2 efficiencies of the
motors and an efficiency
>96 % assumed
Order numbers
Order Number HF1K 7-400 HF1K 13-400 HF1K 18-400 HF1K 24-400 HF1K 30-400 HF1K 50-400
Symmetrical loading by
converters with B6U input
rectifiers
150 % for 60 sec.
every 10 min.
-10 °C to +45 °C,
without condensation
>500.000 h
@ 40°C/400Vac
IE2 efficiencies of the
motors and an efficiency
>96 % assumed
Symmetrical loading by
converters with B6U input
rectifiers
150 % for 60 sec.
every 10 min.
-10 °C to +45 °C,
without condensation
>500.000 h
@ 40°C/400Vac
IE2 efficiencies of the
motors and an efficiency
>96 % assumed
Symmetrical loading by
converters with B6U input
rectifiers
150 % for 60 sec.
every 10 min.
-10 °C to +45 °C,
without condensation
>500.000 h
@ 40°C/400Vac
IE2 efficiencies of the
motors and an efficiency
>96 % assumed
Symmetrical loading by
converters with B6U input
rectifiers
150 % for 60 sec.
every 10 min.
-10 °C to +45 °C,
without condensation
>500.000 h
@ 40°C/400Vac
IE2 efficiencies of the
motors and an efficiency
>96 % assumed
Symmetrical loading by
converters with B6U input
rectifiers
150 % for 60 sec.
every 10 min.
-10 °C to +45 °C,
without condensation
>500.000 h
@ 40°C/400Vac
IE2 efficiencies of the
motors and an efficiency
>96 % assumed
Subject to change
483