Bk Precision 1672 User Manual

Model 1672, 1673
Triple Output Power Supply
INSTRUCTION MANUAL

1 Safety Summary

The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of operation, service, and repair of this instrument. Before applying power, follow the installation instructions and become familiar with the operating instructions for this instrument.
GROUND THE INSTRUMENT
To minimize shock hazard, the instrument chassis and cabinet must be connected to an electrical ground. This instrument is grounded through the ground conductor of the supplied, three-conductor ac power cable. The power cable must be plugged into an approved three-conductor electrical outlet. Do not alter the ground connection. Without the protective ground connection, all accessible conductive parts (including control knobs) can render an electric shock. The power jack and mating plug of the power cable meet IEC safety standards.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Do not operate the instrument in the presence of flammable gases or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard.
KEEP AWAY FROM LIVE CIRCUITS
Instrument covers must not be removed by operating personnel. Component replacement and internal adjustments must be made by qualified maintenance personnel. Disconnect the power cord before removing the instrument covers and replacing components. Under certain conditions, even with the power cable removed, dangerous voltages may exist. To avoid injuries, always disconnect power and discharge circuits before touching them.
DO NOT SERVICE OR ADJUST ALONE
Do not attempt any internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present.
DO NOT SUBSTITUTE PARTS OR MODIFY THE INSTRUMENT
Do not install substitute parts or perform any unauthorized modifications to this instrument. Return the instrument to B&K Precision for service and repair to ensure that safety features are maintained.
Do not alter the ground connection. Without the protective ground connection, all accessible conductive parts (including
lectric shock. The power jack and
To avoid electrical shock hazard, disconnect power cord before
e line cord to the AC mains, check the rear panel AC line voltage indicator. Applying a line voltage other than the indicated voltage can destroy the AC line fuses. For continued fire protection, replace fuses only with those of the
­static discharge (ESD). To avoid damage, be sure to follow proper procedures for handling, storing and transporting parts
WARNINGS AND CAUTIONS
WARNING and CAUTION statements, such as the following examples, denote a
hazard and appear throughout this manual. Follow all instructions contained in these statements.
A WARNING statement calls attention to an operating procedure, practice, or condition, which, if not followed correctly, could result in injury or death to personnel.
A CAUTION statement calls attention to an operating procedure, practice, or condition, which, if not followed correctly, could result in damage to or destruction of parts or the entire product.
WARNING:
control knobs) can render an e mating plug of the power cable meet IEC safety standards.
WARNING:
removing covers. Refer servicing to qualified personnel.
CAUTION:
CAUTION:
SAFETY SYMBOL
Before connecting th
specified voltage and current ratings.
This product uses components which can be damaged by electro
and subassemblies which contain ESD-sensitive components.
This symbol on an instrument indicates that the user should refer to the
operating instructions located in the manual.
Electrical shock hazard.
Chassis ground symbol.
Compliance Statements
Disposal of Old Electrical & Electronic Equipment (Applicable in the European
Union and other European countries with separate collection systems)
This product is subject to Directive 2002/96/EC of the
European Parliament and the Council of the European
Union on waste electrical and electronic equipment
(WEEE), and in jurisdictions adopting that Directive, is
marked as being put on the market after August 13, 2005,
and should not be disposed of as unsorted municipal
waste. Please utilize your local WEEE collection facilities
in the disposition of this product and otherwise observe
all applicable requirements.
Table of Contents
1 Safety Summary .......................................................................................................................... 1
2 Introduction ................................................................................................................................. 5
3 Installation .................................................................................................................................... 5
3.1 Initial Inspection .............................................................................................................. 5
3.2 Input Power Requirements......................................................................................... 6
3.3 Location ............................................................................................................................... 6
4 Controls and Indicators ........................................................................................................... 7
4.1 Front Panel ......................................................................................................................... 7
4.2 Rear Panel ........................................................................................................................... 8
5 Operating Instructions ............................................................................................................ 9
5.1 Setting the Output Voltage and Output Current ................................................ 9
5.2 Constant Voltage (CV) /Constant Current (CC) Mode ..................................... 9
5.3 System Configuration ................................................................................................. 10
5.3.1 Independent Mode ............................................................................................ 10
5.3.2 Series Tracking Mode ...................................................................................... 10
5.3.3 Parallel Tracking Mode ................................................................................... 11
5.3.4 Multiple Units in Series Mode ...................................................................... 12
5.3.5 Multiple Units in Parallel Mode ................................................................... 13
5.3.6 Fixed 5V/3A Output ......................................................................................... 14
6 Specifications ............................................................................................................................ 15
7 Maintenance .............................................................................................................................. 16
7.1 Preventive Steps ........................................................................................................... 16
7.2 When the Unit is Not Turning On .......................................................................... 17
7.3 Fuse Replacement ........................................................................................................ 17
8 Service Information ............................................................................................................... 18
9 Limited Two-Year Warranty .............................................................................................. 19