Bird Technologies 61-70-50 User Manual

Signal Booster II
UHF Series
Mission Critical Reliability for In-building Coverage . . .
The Bird® Signal Booster II provides Public Safety grade reliability and coverage in disadvantaged RF locations for First Responders, Public Safety/Governmental agencies and Private System Users. Reliable RF coverage is gained in basements, parking garages, correctional facilities, courthouses, hospitals, malls and schools. Other challenging environments covered by the Signal Booster II product include subways and rapid transit systems, airports, stadiums/arenas, high-rise buildings and large private enterprise facilities and campuses.
Output Level Control (OLC) Circuit Monitors and Controls RF Output Power
} Maintains maximum required output power while preventing damage
and excessive emissions per FCC requirements
} Easy-to-read LED bar graph } Unique OLC DataLog feature facilitates system maintenance and optimization
Decoupled RF Test Points For Simplied Service
} Allow fast system measurements in both uplink and downlink directions } Monitor signals for performance optimization } Integrated design facilitates non-intrusive measurements
Secure, Non-Vented NEMA Enclosure Suitable for Extreme Indoor and Outdoor Environments
Simple setup is achieved Via an Integral, Intuitive Web Browser User Interface
} No Tools Required
Optional Features Available
} Comm Card II for remote communications and control } Fiber optic link interface* } Redundant PA conguration* } -48 VDC input* } Automatic Voice / Pager Dialer
DC Backup Interface Accepts +24 to +27 VDC and optional -48 VDC
*Contact Factory for these models
TX RX Systems Brand
Microprocessor Controlled Fault Monitoring and Alarming Ensures Reliable Operation and Flexible Conguration
} Control system continuously monitors parameters including voltage,
current, temperature and OLC activity
} LEDs on each module quickly annunciate source of fault
} Simple, back-lit liquid crystal display (LCD) and switch control
} Fault triggers annunciation on panel, alarm contact closure and
internal recording of failed subsystem
Card Cage Modularity
} Easy “slide-in” replacement process } Facilitates ease of service and system conguration
High Performance Bandpass Filters
} Congured to customer requirements and addresses many
specications requiring custom passbands
} Standard models available with a variety of passbands*
Programmable Gain Setting
} Ease of initial conguration via front panel } When used in conjunction with OLC DataLog, simplies post
installation adjustments
Three Major Gain Ranges Available
} Low:+ 45 dB, Medium:+ 60 dB, High:+ 80 dB
Signal Booster II
UHF Series
SPECIFICATIONS
Frequency Range See chart below
Passbands See chart below
Minimum Gain (dB)*
(depending on model)
+45 dB +60 dB +80 dB
Gain Adjustment Programmable attenuation,
0-30 dB, 0.5 dB steps
3rd Order Output Intercept Point +54 dBm minimum, with no
attenuation
Maximum Input Level 0 dBm
RF Sampler PA Output sampler (-30 dB)
Operating Temperature Rang -30°C to +50° C
Nominal impedance 50 ohms, <1.5:1 VSWR
Input/Output connectors N female
RF Sampler Connectors BNC female
AC Power Input 100-240 VAC; 50-60 Hz
DC Input Voltage +24 to +27 VDC
-48 VDC optional
SignalBoosterII_UHF-9262013
30303 Aurora Rd. Solon, OH 44139 866.695.4569 www.bird-technologies.com
Maximum Output Power 32 dBm (single carrier)
Noise Figure (without attenuation)
61-65-50
61-70-50, 61-71-50, 61-72-50
8 dB max for narrow BW 3 dB max for wide BW 8 dB max for Medium Gain, High Gain (Head end) 11 dB max for Low Gain (in Line)
Propagation Delay <0.5 μs
Unit Power Consumption (AC/DC) <150 VA
Housing** Painted Steel NEMA, Stainless
Steel NEMA 4X, 19 inch Rack Mount
FCC Certication*** EZZ5PI616550
Industry Canada Certication*** 1940A-PI616550
617050, 617150, 617250 SERIES SIGNAL BOOSTER II MODEL MATRIX
Model Number Frequency Range Passbands Min. Guardband Nominal Size Net Weight
61-70-50-X0.15-XX 450-470 MHz 0.15 MHz 4.85 MHz 30” x 24” x 12” 130 lbs 61-70-50-X0.5-XX 450-470 MHz 0.5 MHz 4.5 MHz 30” x 24” x 12” 130 lbs 61-70-50-X0.75-XX 450-470 MHz 0.75 MHz 4.25 MHz 30” x 24” x 12” 130 lbs 61-70-50-X1.0-XX 450-470 MHz 1.0 MHz 4.0 MHz 30” x 24” x 12” 130 lbs 61-70-50-X1.25-XX 450-470 MHz 1.25 MHz 3.75 MHz 30” x 24” x 12” 130 lbs 61-70-50-X2.0-XX 450-470 MHz 2.0 MHz 3.0 MHz 30” x 24” x 12” 210 lbs 61-71-50-X0.15-XX 470-490 MHz 0.15 MHz 2.85 MHz 30” x 24” x 12” 130 lbs 61-71-50-X0.5-XX 470-490 MHz 0.5 MHz 2.5 MHz 30” x 24” x 12” 130 lbs 61-71-50-X0.75-XX 470-490 MHz 0.75 MHz 2.25 MHz 30” x 24” x 12” 130 lbs 61-72-50-X0.15-XX 488-512 MHz 0.15 MHz 2.85 MHz 30” x 24” x 12” 130 lbs 61-72-50-X0.5-XX 488-512 MHz 0.5 MHz 2.5 MHz 30” x 24” x 12” 130 lbs 61-72-50-X0.75-XX 488-512 MHz 0.75 MHz 2.25 MHz 30” x 24” x 12” 130 lbs
616550 SERIES SIGNAL BOOSTER II MODEL MATRIX
Model Number Frequency Range Passbands Min. Guardband Nominal Size Net Weight
61-65-50-X0.8-XX 406-430 MHz 0.8 MHz 4.0 MHz 30” x 24” x 12” 130 lbs 61-65-50-X1.0-XX 406-430 MHz 1.0 MHz 4.0 MHz 30” x 24” x 12” 130 lbs 61-65-50-X2.0-XX 406-430 MHz 2.0 MHz 3.0 MHz 30” x 24” x 12” 130 lbs 61-65-50-X3.0-XX 406-430 MHz 3.0 MHz 4.0 MHz 30” x 24” x 12” 130 lbs 61-65-50-X5.0-XX 406-430 MHz 5.0 MHz 5.0 MHz 30” x 24” x 12” 130 lbs
* X = Gain A=80 dB, B=60 dB, C=45 dB ** XX = Housing Options G1: Painted Steel NEMA 4, G2: Stainless Steel NEMA 4X, RM: 19 inch Rack Mount (Frequencies MUST be provided with order).
Model Number Example 61-70-50-A0.15-G1 *** Class B Type Booster. Type Acceptance under FCC Rules Part 90 and Industry Canada Certication Part RSS-131.
Please Contact Factory 716.549.4700 for non-standard congurations with custom frequency, windows and bandwidth.