Bird Technologies 4421-488 User Manual

MODEL 4421-488 PROGRAMMING CARD
General Bus Commands
FUNCTION COMMAND DESCRIPTION
Initialize INT Place in factory-set default conditions Command
Trigger Software Hand-
shake Enter Data ENT Send a reading to RS-232 controller Baud Select B1
Device Dependant Commands
FUNCTION COMMAND DESCRIPTION
Measurement FC
Range RYY
Terminators YT
Prefixes PY
Triggers T0
Status U0
Self-Test J0 Run selt-test Writable Store WXXXXXX Place XXXXXX in RAM
TRG Take a reading in T3 (one shot on trigger mode)
XO XF
B2 B3
B4 B5
B6 B7
FD RC
RD SW
RL MN
MX
R00 R01
. .
. R17
RNN
YO YN
PN
T1 T3
T5
U1 U2
Enable software handshake Disable software handshake
Set to 110 Set to 300
Set to 600 Set to 1200 Set to 2400
Set to 4800 Set to 9600
Forward Carrier Wave Forward dBm
Reflected Carrier Wave Reflected dBm
Standing Wave Ratio Return Loss
Minimum Loss Maximum Value
Auto range on Lowest range
Highest range Auto range off—stickon present range
Two terminators: CR, LF One terminator: CR No terminator
Prefix yes Prefix no
Continuous on ENT One shot on ENT
One shot on TRG One shot on measuerment command
Send back current machine state Send back error conditions Send back revision levels
MODEL 4421-488 PROGRAMMING CARD
FD RC
RD SW
RL MN
MX
R00 R01
. .
. R17
RNN
YO YN
PN
T1 T2
T3 T4
T5
M01 M02
M04 M08
U1 U2
KN
1
Places module in remote mode Places module in local mode
Lock out operation of power meter’s front panel pushbuttons Places module in talker and listener idle states
Returns module to factory default condition Returns selected module to factory default condition
Forward Carrier Wave Forward dBm
Reflected Carrier Wave Reflected dBm
Standing Wave Ratio Return Loss
Minimum Loss Maximum Value
Auto range on Lowest range
Highest range Auto range off—stickon present range
Two terminators: CR, LF One terminator: CR No terminator
Prefix yes Prefix no
Continuous on Talk One shot on Talk
Continuous on GET One shot on Get
Continuous on measurement Command One shot on measuerment command
Do not generate SRQ Generate SRQ on Error (IDDC, IDDCO, Buffer Overflow)
Generate SRQ on measurement overrange Generate SRQ on measurement underrange Generate SRQ on operation complete
Send back current machine state Send back error conditions Send back revision levels
Send EOI on last byte Do not send EOI on last byte
General Bus Commands
FUNCTION DESCRIPTION
Remote (REN) GO to Local (GTL)
Local Lockout (LLO) Interface Clear(IFC)
Device Clear (DCL) Selective DeviceClear (SDC)
Group Execute Trigger (GET) Provides trigger for T2 and T3 trigger modes Serial Poll Enable/Disable (SPE/SPD) Status byte is put on bus
1
Refer to controllermanual for structure of bus command.
2
Letters within ( ) represent mnemonics for bus function.
2
Device Dependant Commands
FUNCTION COMMAND DESCRIPTION
Measurement FC
Range RYY
Terminators YT
Prefixes PY
Triggers T0
Serial Polling M00
Status U0
Self-Test J0 Run selt-test EOI Response KY
Writable Store WXXXXXX Place XXXXXX in RAM