TX RX Systems Brand
Control Station Combiner
43-83G-01A Series
Bird®, TX RX Systems Brand multi-channel combiners provide frequency-agile operation across their
entire frequency range. Control Station Combiners may be used to reduce the number of antennas
required on a communications site while also ensuring that predictable radio-to-radio isolation is
maintained at all times - irrespective of individual radio’s Tx or Rx operating mode or antenna isolation
characteristics.
Single antenna-port mobiles may be connected to the combiners to provide operation on two-antenna
congurations (one Tx and one Rx), or through a duplexer to a single antenna (i.e. Tx/Rx). These capabilities
can significantly reduce tower clutter and loading, and simplify cabling installation at Control Center
facilities.
Models are available in the 746-869 MHz band in standard configurations for 4, 8,12 and 16 capacities.
Other frequency bands and higher channel capacities are also available upon request.
} Low Prole for Space Ecient Installation
} Frequency Agile with Predictable Isolation
} Analog and Digital Compatible
} Duplexer and Triplexer Recommended to be used in
conjunction with Control Station Combiners
Control Station Combiner
43-83G-01A Series
SPECIFICATIONS
Frequency Range 746-869 MHz
RF Power W TX
Minimum Frequency
Separation MHz
Loss dB See table below
Isolation dB TX RXTX - Tx: 60 min (70 typ.)
Return Loss dB >14 (typ)
Operating
Temperature Celsius
Finish Black
Dimensions
mm/inches
Weight See model matrix table below
Connectors N female
* Applications with higher duty cycles may require cooling fan.
Contact factory for more info.
Per Channel: 50 (50% duty cycle max)*
Per Channel: <150 (intermittent)
RX
N/A
No limitations
Ant - Tx: 60 min (70 typ.)
Rx to Rx: 60 min (70 typ.)
Tx to Rx: 60 min (70 typ.)
-10 ~ +50
H (See table below)
W 483 / 19
D 420 / 16.5
DUPLEXER RECOMMENDED OPTIONS
Frequency Range (MHz) 26-83B-10A
26-83G-10A
26-89A-10A
Bandwidth (MHz) 26-83B-10A
26-83G-10A
26-89A-10A
Insertion Loss (dB), max. 1.5
Ripple in band (dB), max. 0.8
Rejection (dB), min. 70 between T/R
Isolation (dB), min. 26-83B-10A
26-83G-10A
26-89A-10A
Impedance 50
Return Loss (dB), min. 26-83B-10A
26-83G-10A
26-89A-10A
Connector N-female
Power Rating (W) 26-83B-10A
26-83G-10A
26-89A-10A
Temperature (°C) -20 ~ +70
Size (in/mm)* 26-83B-10A
26-83G-10A
26-89A-10A
762-776/792-806
762-776/792-824/851-869
806-824/851-869
14
14/32/18
18
80
70
80
20
18
20
100
50
100
8.0(204)x6.0(153)x1.4(36)
10.1(257)x8.2(207)x1.7(44)
8.0(204)x6.0(153)x1.4(36)
Attached to 1RU front panel for 19” rack mounting
CONTROL STATION COMBINER MODEL MATRIX
Model Numbers Description Insertion Loss Height Net Weight
43-83G-01A-04 746-869 MHz, 4 Channel 8dB 1RU 12.5 lbs
43-83G-01A-08 746-869 MHz, 8 Channel 11.5dB 1RU 24 lbs
43-83G-01A-12 746-869 MHz, 12 Channel 15dB 3RU 35.5 lbs
43-83G-01A-16 746-869 MHz, 16 Channel 15dB 3RU 47 lbs
30303 Aurora Rd. Solon, OH 44139 866.695.4569 www.bird-technologies.com