Bird Technologies 4020 User Manual

©Copyright 2003 by Bird Electronic Corporation
Instruction Book Part Number 920-4020S Rev. F
Specifications
RFL Accuracy FWD Accuracy
FWD Power
10
Directivity 10/
---------------------------------+=
VSWR 1
P
R
P
F
------+



1
P
R
P
F
------



=
CAUTION
Changing the sensor’s connectors will invalidate calibration data, and may
reduce the maximum power rating of the unit.
Frequency Range
4021 4022 4024 4025
RF Power Range
4021, 4022 4024, 4025
Accuracy, Fwd, Best Case
Accuracy, Reflected Calculated from Fwd accuracy and power
Accuracy, VSWR Calculated from FWD and RFL power
300 mW – 1 kW 3 W – 10 kW
*
± 3% (1σ)
Impedance, Nominal 50 ohms
VSWR, Max.
4021, 4024, 4025 4022
Insertion Loss, Max. (with female “N” connectors)
4021, 4024, 4025 4022
Directivity, Min.
4021, 4022 4024
4025
1.05:1
1.05:1, 25 – 512 MHz
1.10:1, 512 MHz – 1 GHz
0.05 dB
0.05 dB, 25 – 512 MHz
0.13 dB, 512 MHz – 1 GHz
30 dB 28 dB, 1.5 – 2.5 and 25 – 32 MHz 30 dB, 2.5 – 25 MHz 28 dB, 100 – 125 kHz 30 dB, 125 – 2500 kHz
Max. Allowable Terminating
2.00:1
VSWR
VSWR Range 1.00 to 2.00 (40.0 to 9.5 dB Return Loss)
Calibration Technique Frequency-specific calibration factors stored in
nonvolatile memory in each sensor. Sensor output corrected for frequency and tempera­ture within specified ranges.
Cal. Cycle, Nominal 1 year
Connectors Customer specified from QC list, appropriate
for frequency and power.
Sampling Rate, Nominal 2 readings/second
Operating Power Supplied by power meter via sensor cable
Humidity, Max. 95% (Non-condensing)
Altitude, Max. 10,000 feet (3,000 m)
CE CE Compliant. Refer to Declaration of Confor-
mity for specific standards.
Temperature Range
Operating Storage
0 to 50 °C (32 to 122 °F) –20 to +70 °C (–4 to +158 °F)
Dimensions 5.2”L x 2.5”W x 3.25”H
(137 x 64 x 83 mm)
Weight, Nominal 1 lb. 13 oz. (0.8 kg)
* For rated accuracy, no more than 1% AM; Harmonics –50 dBc or
less Derate accuracy by 3.0% (1
σ) below 15 °C and above 35 °C
Special Lifetime Warranty –
Series 4020 Power Sensor Head
In addition to its standard warranty, the Bird Electronic Corporation warrants its Series 4020 Thruline® Power Sensor Heads for lifetime to original purchaser. This extended warranty is against burnout. For the warranty to apply, the Sensor Head must be used with the correct Bird Electronic Corporation Display Unit, the maxi­mum power rating of the Sensor must not be exceeded, the Sensor RF circuit must be properly terminated and the Sensor not subjected to physical abuse.
Bird Electronic Corporation, at its option, will repair or replace the defective Sensor at its world Headquarters at 30303 Aurora Road, Solon, Ohio 44139.
The customer is responsible to pay transportation charges to return the defec­tive sensor to Bird.
Loading...