Digital Hotplate Stirrer
Catalog # 12004615
12004616
12004617
12004618
Instruction Manual
Catalog # 12004615
120 0 4 616
120 0 4 617
120 0 4 618

Introduction
Congratulations on the purchase of your hotplate stirrer.
In order to ensure the safe operation of the equipment, please read this manual in its entirety
before use.
System Components
Description Quantity
Hotplate stirrer
Power cord
Stir bar
Installation
Place the Digital Hotplate Stirrer on a fl at, level surface, with at least a 4 inch (10 cm)
clearance on all sides. Attach provided power cord to rear of unit and plug into a grounded
outlet of appropriate voltage.
Warning! Do not store or operate this instrument near a sink or water source as
contact with water could cause electrical shock.
Warning! The outlet voltage must match the voltage listed on the label on rear of
instrument. Failure to supply appropriate power may damage instrument and void
the warranty.
Note: Place the instrument so that the power cord is readily accessible and can be pulled
out of the electrical outlet easily.
Specifi cations
Description Specifi cation
1
1
1
Speed
Temperature
Platform dimensions
Electrical
Power consumption
200–1,500 rpm
Ambient 5–380°C
6.5 x 6.5 in.
115 V/60 Hz or 230 V/60 Hz
Max: 500 W
Control Panel
A) Hot surface indicator light:
illuminates when instrument is
powered on and the surface
temperature is above 50°C.
B) LCD Display: top line displays
the stir speed in RPM. Bottom line
displays the temperature in degrees
Celsius. At right, a symbol shows
the on/off state of the stir and heat
functions.
C) Temperature selection keys: increase or decrease the set point.
D) Selection knob (dial and button): press the button to start/stop the heat and stir
functions. Rotate the dial to adjust stir bar speed (rpm).
1 | Digital Hotplate Stirrer Instruction Manual
A
B
D
C

Operation
•
Power on the instrument by setting the power switch (rear of instrument) to the “I” position
• Set the stir speed by turning the dial. The stir speed will appear at the top of the LCD
display. To operate without stirring, set the stir speed to zero and turn the dial
counterclockwise until the stirring stops
Set temperature by using the up ▲ and down ▼ keys below the display. The temperature
•
you set will appear at the bottom of the display. To operate without heating, set
temperature to zero
• Once the desired stir speed and temperature are set, press the selection knob to
begin stirring and heating. The stir speed and temperature will begin to adjust to the set
parameters
Warning! Once the selection knob has been pressed, the top of the instrument will
Maintenance
• To clean the body and surface plate of the instrument, unplug the unit and allow the
instrument to completely cool to room temperature. When the unit has cooled, use
a lint-free rag to wipe down all surfaces
begin to heat up very rapidly. Do not touch the heating surface as this can result in
bodily injury, including burns. Keep volatile or fl ammable substances away from the
instrument.
Warning!
Doing so may damage the instrument and void the warranty.
Tro ub le sh ooting
Problem Potential cause Troubleshooting
No heating or stirring
Ordering Information
Catalog # Description
12004615 Digital Hotplate Stirrer, 120 V
12004616 Digital Hotplate Stirrer, 230 V, Europe
12004617 Digital Hotplate Stirrer, 230 V, UK
12004618 Digital Hotplate Stirrer, 230 V, Australia
Do not immerse in water or spray cleaner directly on the instrument.
No/insuffi cient power delivered to unit
Blown fuse
Check that both ends of the power cord
are fi rmly connected.
Replace the fuse.
Digital Hotplate Stirrer Instruction Manual | 2

Bio-Rad Technical Support
The Bio-Rad Technical Support Department in the U.S. is open Monday through Friday, 5:00 AM to 5:00 PM, Pacifi c time.
Phone: 1-800-424-6723, option 2
Email: Support@bio-rad.com (U.S./Canada Only)
For technical assistance outside the U.S. and Canada, contact your local technical support offi ce or click the Contact us
link at www.bio-rad.com.
Legal Notices
Bio-Rad reserves the right to modify its products and services at any time. This instruction manual is subject to change
without notice. Although prepared to ensure accuracy, Bio-Rad assumes no liability for errors, or for any damages
resulting from the application or use of this information.
Warranty
The Digital Hotplate Stirrer is covered by a standard Bio-Rad warranty. Contact your local Bio-Rad Laboratories offi ce
for the details of the warranty.
Safety Warnings
A Warning! symbol in this manual warns you about sources of injury or harm, including
risk of electrical shock.
Do not heat substances that react violently when heated.
Do not use this instrument near fl ammable or explosive materials.
Do not touch top surface when hot or when unit is heating.
Do not attempt to repair or remove the outer case of the hotplate stirrer or other accessories. If
you open this instrument, you put yourself at risk for harm to body or equipment from electrical
shock.
Life Science
Group
Connect unit only to a properly grounded outlet.
Use of this product in any manner not specifi ed by the manufacturer or any modifi cation of the
product may cause injury and/or may void the warranty.
Copyright © 2017 by Bio-Rad Laboratories, Inc. All rights reserved.
Bio-Rad
Laboratories, Inc.
Web site bio-rad.com USA 1 800 424 6723 Australia 61 2 9914 2800 Austria 43 1 877 89 01 177 Belgium 32 (0)3 710 53 00 Brazil 55 11 3065 7550
Canada 1 905 364 3435 China 86 21 6169 8500 Czech Republic 420 241 430 532 Denmark 45 44 52 10 00 Finland 358 09 804 22 00
France 33 01 47 95 69 65 Germany 49 89 31 884 0 Hong Kong 852 2789 330 0 Hungary 36 1 459 6100 India 91 124 4029300
Israel 972 0 3 963 6 050 Italy 39 02 216091 Japan 81 3 6361 7000 Korea 82 2 3473 4460 Mexico 52 555 488 7670 The Netherlands 31 (0) 318 540 666
New Zealand 64 9 415 2280 Norway 47 23 38 41 30 Poland 48 22 331 99 99 Portugal 351 21 472 7700 Russia 7 495 721 14 04
Singapore 65 6415 3188 South Africa 27 (0) 861 246 723 Spain 34 91 590 5200 Sweden 46 08 555 12700 Switzerland 41 026 674 55 05
Tai wa n 886 2 2578 7189 Thailand 66 2 651 8311 United Arab Emirates 971 4 818730 0 United Kingdom 44 020 8328 2000
10000070758 Ver A US/EG
0617 Sig 1216