Model FD-S 56 | Drying and heating chambers with forced convection
The new products in the Solid.Line impress with their tried-and-tested BINDER quality and reliability. They are suited to drying and heating. The attributes of
the Solid.Line are geared towards the application in question and therefore used in research and quality assurance.
BENEFITS
• Easy handling
• Accurate temperature control
• Simple and ergonomic door opening
Model 56
MAIN FEATURES
• Temperature range: +10 °C above ambient temperature to +250 °C
• APT.line™ preheating chamber technology
• Forced convection
• Adjustable exhaust air flap
• Controller with timer function
• 1 chrome-plated rack, incl. shelf supports
• Class 2 integrated independent adjustable temperature safety device (DIN
Temperature range +10°C above ambient temperature to [°C]250250
Temperature variation at 150°C [± K]2.62.6
Temperature fluctuation at 150°C [± K]0.50.5
Heating-up time to 150°C [min]2020
Air change data
Air change (approx.) at 100°C [x/h]8080
BINDER Data Sheet | As of: 04.11.2020
Technical specications are subject to change.
Page1 / 4
Data Sheet Model FD-S 56
DescriptionFDS056-230VFDS056UL-120V
Article Number9090-00189090-0019
Electrical data
Rated Voltage [V]230120
Power frequency [Hz]50/6060
Nominal power [kW]1.11.1
Unit fuse [A]6.36.3
Phase (Nominal voltage)1~1~
Measures
Interior volume [L]5555
Net weight of the unit (empty) [kg]3634
Permitted load [kg]3030
Load per rack [kg]1515
Wall clearance back [mm]160160
Wall clearance sidewise [mm]100100
Internal Dimensions
Width [mm]400400
Height [mm]440440
Depth [mm]310310
Doors
Unit doors11
Housing dimensions not incl. ttings and connections
Width net [mm]614614
Height net [mm]625625
Depth net [mm]577577
Environment-specic data
Energy consumption at 150°C [Wh/h]290290
Sound-pressure level [dB(A)]4343
Fixtures
Number of shelves (std./max.)1/31/3
DIMENSIONS incl. ttings and connections [mm]
ACCESSORIES
DesignationDescription*Art.-No.
Data Logger Kit
Data Logger SowareLOG ANALYZE soware kit, conguration and evaluation soware for all BINDER Data Logger Kits (incl. USB data cable)
Grid shelf
pH-neutral detergentconcentrated, for gentle remove of residual contaminants; 1 kg
Rubber padsset anti-slip feet
* Notes › See last page
T 350: For continuous temperature logging from 0 °C to 350 °C; kit includes 1 data logger, Pt 100 sensor with 2 m
extension cable and 1 magnetic xture for mounting to the BINDER unit
Connect the unit to the customer-side connections (electricity, water, wastewater, gas), basic functions
Unit instructions
Instruction regarding operating principle and basic functions of the unit, operation of the control
electronics including programming
Maintenance services
Maintenance service in accordance with maintenance schedule. Visual inspection of mechanical and
Maintenance
electrical components, testing of all key functions. Calibration of a test temperature specied by the user
in center of chamber without certicate
Calibration services
Calibration of one (1) test temperature specied by the user in center of chamber including certicate
Calibration certicate, temperature
Extension of calibration of one (1) additional test temperature specied by the user in the center of the
usable space, including certicate
Measurement of air exchange rateincluding certicate (in accordance with ASTM D5374)
Temperature measurement, 27
measuring points
Temperature measurement, 9
measuring points
Temperature measurement with 27 measuring points with a set value specied by the user, including
certicate
Temperature measurement with 9 measuring points with a set value specied by the user, including
certicate
Warranty service
Warranty extension from 2 to 3 yearsThe warranty is extended from 2 to 3 years from the delivery date, wear parts are excluded
* Notes › See last page
05
05
05
03, 04,
05
03, 04,
05
03, 04,
05
03, 04,
05
03, 04,
05
–
DL10-0100
DL10-0500
DL20-0200
DL30-0101
DL30-0102
DL33-0000
DL30-0127
DL30-0109
DL00-3041
BINDER Data Sheet | As of: 04.11.2020
Technical specications are subject to change.
Page3 / 4
Data Sheet Model FD-S 56
NOTES
01Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge.
02UL mark is not granted when this option is used.
03Sensor calibration is performed in an accredited calibration laboratory.
04Calibration is performed according to the BINDER factory standard.
05Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not
include a country-specic added fee (available on request).