Biamp NE-XIA TC User Manual

Nexia® TC
Teleconference DSP
Nexia TC is a digital signal processor with 8 wide-band AEC mic/line inputs, 2 standard mic/line inputs, 4 mic/line outputs, and a telephone interface. Intended for a variety of teleconferencing applications, Nexia TC uses Biamp’s proprietary Sona™ AEC algorithm for more natural sound and full-duplex transmission of speech. Nexia TC includes a broad selection of audio components, routing options, and
signal processing. The internal system design is completely user denable via PC software, and can
be controlled via daVinci™ software screens, RS-232 control systems, and a variety of optional remote controls. Multi-unit Nexia systems can be created utilizing Ethernet and NexLink digital audio linking.
FEATURES
• 8 wide-band AEC balanced mic/line inputs
• 2 standard balanced mic/line inputs
• 4 balanced mic/line outputs
• telephone interface with line & set connections
• Ethernet port for software conguration/control
• serial port for third-party RS-232 remote control
• NexLink ports for multi-unit system designs
• Nexia software for Windows® XP Professional/Vista
• pre-congured I/O with denable processing
RoHS compliance and AES grounding practices
CE marked and UL/C-UL listed
• covered by Biamp Systems’ ve-year warranty
• Ability to select, view, and calibrate:
Mixers, Equalizers, Filters, Crossovers, Dynamics,
°
Routers, Delays, Controls, Meters, Generators, Diagnostics
• Telephone Interface capabilities include:
initiation of outgoing calls
°
detection and answering of incoming calls
°
line echo cancellation
°
TouchTone™ decoding
°
caller ID reception
°
call progress detection
°
line intrusion detection
°
continuous line status and fault monitoring
°
ARCHITECTS & ENGINEERS SPECIFICATION
The teleconference DSP shall provide eight wide-band Sona™ AEC balanced mic/line inputs, two standard balanced mic/line inputs, and four balanced mic/line outputs on plug-in barrier-strip connectors. A telephone interface shall be provided on a pair of RJ11 jacks. Inputs and outputs shall be analog, with internal 24-bit A/D & D/A converters operating at a sample rate of 48kHz. All internal processing shall be digital (DSP). NexLink connections shall allow sharing of digital audio within multi-unit systems. Software shall be provided for creating/connecting DSP system components within each hardware unit. Available
system components shall include (but not be limited to) various forms of: mixers, equalizers, lters, crossovers, dynamics/
gain controls, routers, delays, remote controls, meters, generators, and diagnostics. Ethernet communications shall be
utilized for software control and conguration. After initial programming, processors may be controlled via dedicated
software screens, third-party RS-232 control systems, and/or optional remote control devices. Software shall operate on a PC computer, with network card installed, running Windows® XP Professional/Vista. The teleconference DSP shall be CE marked, UL listed, and shall incorporate AES48-2005 Grounding & EMC practices. The teleconference DSP shall
be compliant with EU Directive 2002/95/EC, the RoHS directive. Warranty shall be ve years.
The teleconference DSP shall be Nexia® TC.
Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A. (503) 641-7287 www.biamp.com
Nexia TC SPECIFICATIONS
100-240V
~
50/60Hz
65 Watts, 1.0 A
24VDC @ 0.5A
term hi lo
Ethernet
Line Set
NexLink Tx
NexLink Rx
2 14 3 4 36 58 710 9 2 1
outputs
CAUTION
RISK OF ELECTRICAL SHOCK.
DO NOT OPEN.
Remote
Control Bus
mic/line inputstelephone AEC inputs
serial
U
L
R
CUS
52SJ
LISTED
Installation Instructions: Nexia TC
This device must be installed by qualified, trained personnel. Connections to the
telephone network must be made with #26 AWG solid copper wire for continued safety.
MODEL Nexia TC
US:6RMBR00BNEXIATC
IC:3184A-NEXIAT C
Complies with FCC Part 68
Class 2
wiring
BIAMP SYSTEMS
designed and assembled in the USA
www.biamp.com
Nexia TC BLOCK DIAGRAM
MicroProcessor
DSP Cluster
RS-232
Remote
Control
Bus
Memory
TCP/IP Control
Comms
Analog
Inputs
A/D D/A
Analog
Outputs
NexLink
Rx
NexLink
Tx
Hybrid DAA
Telephone
Line
Telephone
Set
Frequency Response (20Hz~20kHz @ +4dBu): +0/-0.4dB
THD+N (20Hz~20kHz @ +4dBu): line level < 0.006% mic level < 0.05%
Equivalent Input Noise (20Hz~20kHz, 66dB gain, 150 ohm): -125bBu
Dynamic Range (20Hz~20kHz, 0dB): > 105dB
Maximum Gain (input channels): 66dB
Crosstalk (channel-to-channel @ 1kHz): line level < -80dB mic level < -75dB
Output Impedance (balanced): 200 ohms
Input Impedance (mic/line balanced): 8k ohms
Input Gain Range (variable trim): 0dB ~ +66dB
Maximum Output (balanced): +24dBu
Maximum Input (mic/line): +24dBu
Full Scale Output Level (six selections) -31dBu ~ +24dBu
Nexia TC REAR PANEL DIAGRAM
Telephone Interface: ringer equivalency number 0.0B dynamic range 67dBu frequency response 250Hz ~ 3.4kHz THD < 0.3% transhybrid balance 30dB
Tail Length: up to 300ms
Convergence: up to 100dB/sec
Phantom Power: +48 VDC (7mA/input
Sampling Rate: 48kHz
A/D - D/A Converters: 24-bit
Power Consumption (100~240VAC 50/60Hz): 65 watts
Dimensions: height 1.75 inches (45mm) width 19 inches (483mm) depth 11.15 inches (283mm)
Weight: 8.6 lbs. (3.9kg)
Compliance: AES48-2005 Grounding & EMC practices
EU Directive 2002/95/EC, RoHS directive
CE marked
UL listed
Nexia TC BLOCK DIAGRAM
Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A. (503) 641-7287 www.biamp.com
1Feb10
Loading...