Biamp N 100 User guide

PARLÉ™
INSTALLATION AND SETUP GUIDE
N 100™
NETWORK ADAPTER AND PORT EXPANDER
INSTALLATION CONSIDERATIONS
• The N 100 is designed to be installed behind a display or close to the in-room display.
• Do not exceed the maximum ambient operating temperature of 32-104° F (0-40° C). Be aware of conditions in an enclosed rack that may cause the temperature to exceed ambient room conditions.
Warning: The N 100 power supply MUST NOT be connected to a VBC 2500 or ABC 2500 conference bar. The unit will be damaged.
Biampinfo@biamp.com www.biamp.com
INCLUDED IN THE BOX
IN THE BOX
• N 100
• Cable management cover
• Mounting plate
• Wall screws (4)
• Wall anchors (4)
• Mounting-plate screws (4)
• Cover screw (1)
USB 3.0 3’ (1m) Type A to B (1)
• Power supply
• QR-code sheet & safety manual (not shown)
3
2
Installation & Setup Guide N 100
DEVICE LAYOUT
FRONT PANEL
FRONT PANEL INDICATORS
O:
The device is not powered
REAR PANEL
Green:
The device is powered
Red:
The device is booting.
2
3
4 516
REAR PANEL PORTS/TERMINALS/INDICATORS
UC / LAPTOP
1. USB Input Type-B
ROOM AV
2. USB 3.0 Type-A
3. USB 3.0 Type-C
N 100
Installation & Setup Guide
ADDITIONAL
4. RJ45 Network Gigabit Ethernet (LAN)
5. Pinhole Reset
6. Power port 24V/3.75A with lock connector
3
INSTALLATION
REMOVEABLE MOUNTING PLATE
The N 100 may be installed in almost any location that works for the room design, requirements, etc. This includes installation on a wall behind a typical conference room display or under a table. Be
sure to allow for adequate airow on the ventilation grilles.
For installation on a wall, behind a conference room display, or under a table use the provided
mounting plate. Alternatively, place the device on a at surface, with or without the mounting plate,
and the rubber feet will keep the device in place.
1. The mounting plate comes installed on the device and is easily removed.
2. Unscrew the four screws attaching the bracket to the bottom of the device.
3. Place the device on any at surface that does not risk the power cord and connections being snagged, yanked, or crushed.
4. The four rubber feet at the bottom will prevent the device from slipping on the surface.
5
4
Installation & Setup Guide N 100
INSTALLATION
MOUNT THE DEVICE
1. The N 100 comes attached to the mounting plate via four mounting screws. If the bracket has been removed, attach it before attempting to mount the device.
2. Locate a at place to mount the device using the attached mounting plate.
3. Use the four holes on the mounting plate to mark the locations for the wall anchors and screws.
4. Use the provided screws and /or wall anchors to mount the device to the desired location.
N 100
Installation & Setup Guide
5
INSTALLATION
CABLE MANAGEMENT
5. Once the device is in place, use the built-in cable management retainer to keep cables organized and protected from accidental damage.
7
6
Installation & Setup Guide N 100
INSTALLATION
CABLE MANAGEMENT
6. Once the device is in the desired location, and the cables are connected and secure within the cable management retainer, attach the protective cover.
7. The cover will snap into place. Secure the cover using the provided cover screw.
N 100
Installation & Setup Guide
7
CONNECTIONS
COMPLETE SYSTEM DEPLOYMENT
Warning: The Parlé N 100 power supply MUST NOT be connected to a
VBC 2500 or ABC 2500 conference bar as the unit will be damaged. See the Parlé N 100 PSU warning label.
Network
Laptop or
UC Compute
Parlé VBC 2500
TesiraFORTÉ X
Loudspeakers / Mics
Provided Cables
Accessory Cables
Note: To manage the parameters and settings of the N 100 device via web browsers, access the Web Administrator Console here.