INSTALLATION CONSIDERATIONS
• The MPX 100 is designed to be installed behind a display or close to the in-room display.
• The device may be installed in various locations using the provided mounting plate that allows the device to be securely fastened on or under desktops, on walls, and more.
• The mounting plate has a built-in cable management retainer and there are two cable slider clips for additional cable management.
• Do not exceed the maximum ambient operating temperature of 32-104° F (0-40° C). Be aware of conditions in an enclosed rack that may cause the temperature to exceed ambient room conditions.
Warning: the MPX 100 power supply MUST NOT be connected to a VBC 2500 or ABC 2500 conference bar. the unit will be damaged.
Biampinfo@biamp.com www.biamp.com
INCLUDED IN THE BOX
COMPONENTS
CABLES
2 x HDMI 2.0 3’ (1m) 4k60
1 x HDMI 2.0 15’ (5m) 4k60
2 x USB 3.0 3’ (1m) Type A to B
1 x USB 3.0 15’ (5m) Type B to C Active
2
Installation & Setup Guide
DEVICE LAYOUT
FRONT PANEL
FRONT PANEL INDICATOR
O:
The device is not powered
REAR PANEL
2
Green:
The device is powered
3
4 51 7
6
Red:
The device is booting.
8 9 10
REAR PANEL PORTS & TERMINALS
UC
1. HDMI Input 2.0
2. USB Input Type-B
LAPTOP
3. HDMI Input 2.0
4. USB Input Type-B
Installation & Setup Guide
ROOM AV
5. HDMI Output 2.0
6. USB 3.0 Type-A
7. USB 3.0 Type-C
ADDITIONAL
8. RJ45 Network Gigabit Ethernet (LAN)
9. Pinhole Reset
10. Power port 24V/3.75A with lock connector
3
INSTALLATION
REMOVABLE MOUNTING PLATE
The MPX 100 may be installed in almost any location that works for the room design, require­ments, etc. This includes installation on a wall behind a typical conference room display or
under a table. Be sure to allow for adequate airow on the ventilation grilles.
For installation on a wall, behind a conference room display, or under a table use the provided mounting plate. Alternatively, place the device on a at surface, with or with­out the mounting plate, and the rubber feet will keep the device from sliding out of place.
1. The mounting plate comes installed on the device and is easy to remove.
2. Unscrew the four screws attaching the bracket to the bottom of the device.
3. Place the device on any at surface that does not risk the power cord and connections being snagged, yanked, or crushed.
4. The four rubber feet will prevent the device from slipping.
4
Installation & Setup Guide
INSTALLATION
MOUNTING THE DEVICE
1. The MPX 100 comes attached to the mounting plate via four mounting screws. If the bracket has been removed, attach it before attempting to mount the device.
2. Locate a at place to mount the device using the attached mounting plate.
3. Use the four mounting holes on the mounting plate to mark the locations for the wall anchors and screws.
4. Use the provided screws and/or wall anchors to mount the device to the desired location.
Installation & Setup Guide
5
INSTALLATION
CABLE MANAGEMENT
5. Once the device is in place, use the built in cable management retainer to keep cables organized and protected from accidental damage.
6. Once the device is in a desired location and the cables have been connected and secured within the cable management retainer, attach the protective cover.
6
Installation & Setup Guide
INSTALLATION
7. The cover will snap into place. Secure the cover using the provided cover mount screw.
Installation & Setup Guide
7
INSTALLATION
ADDITIONAL CABLE MANAGEMENT
1. Use the included cable slider clips to further mananage cables outside of the cable management retainer. The larger clip is for the 5m long cables and the smaller is for either 10m or 15m long cables.
2. Use the gap opening at he base of the slider clip to insert the cables.
3. Once the cables are in the slider clip, the clip may be moved up or down the
cables to the preferred location for eecive cable management.
8
Installation & Setup Guide
CONNECTIONS
COMPLETE SYSTEM DEPLOYMENT
The MPX 100 supports automatic switching between UC Room Systems and BYOM Cli­ents. By default, without a BYOM connected, the device will be set to UC Room. When a BYOM device is connected the EasyConnect will automatically switch to the BYOM connection.
• Warning: the MPX 100 power supply MUST NOT be connected to a VBC 2500 or ABC 2500 conference bar: the unit will be damaged. See EasyConnect PSU warning label.
Provided Cables
Network
Accessory Cables
UC Compute
Touchscreen Display
Parlé VBC 2500
TesiraFORTÉ X
BYOM Laptop
Loudspeakers / Mics
Installation & Setup Guide
9
CONNECTIONS
UC COMPUTE
Connect the UC Compute device to the MPX 100 via UC ports using one of the provided HDMI cables and one of the provided USB 3.0 Type-A to Type-B cables.
USB Type-A to Type-B HDMI
UC Compute
BYOM LAPTOP
Connect the BYOM laptop device to the MPX 100 via BYOM ports using one of the provided HDMI cables and the provided USB 3.0 Type-B to Type-C active cable.
HDMI USB Type-B to Type-C Active
BYOM Laptop
10
Installation & Setup Guide
CONNECTIONS
AV ROOM
Connect the MPX 100 to AV Room peripheral devices using the provided cables and separate accessory cables.
Provided Cables
Accessory Cables
Network
HDMI
Parlé VBC 2500
Touchscreen Display
• Using one of the provided HDMI cables and one of the provided USB 3.0 Type-A to Type-B cables, connect a touchscreen display device to the EasyConnect via the corresponding HDMI and USB AV Room ports.
TesiraFORTÉ X
USB Type-A to Type-B
Loudspeakers / Mics
• Using up to three of the AV Room USB 3.0 Type-A ports and the one USB 3.0 Type-C port, connect paripheral devices to the system via accessory USB 3.0 Type-A and Type-C cables.
• Use an RJ45 ethernet cable to connect the system to a network via the RJ45 network gigabit ethernet (LAN) port.
Installation & Setup Guide
11
CONTACT US
Email: support@biamp.com
Web: support.biamp.com
Warranty: biamp.com/legal/warranty-information
Safety & Compliance: biamp.com/compliance biamp.com/legal/warranty-information
November 01, 2023
Loading...