1) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The Warnings leaflet and Instruction booklet supplied with this product should be read carefully as they provide important information about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according to the provisions set out by current standards. Keep nylon or polystyrene bags out of childrens reach.
Keep the instructions together with the technical brochure for future reference.
This product was exclusively designed and manufactured for the use specified in the present documentation. Any other use not specified in this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting from improper use of the product, or use which is different from that expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the
following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments. As for all non-EEC countries, the above­mentioned standards as well as the current national standards should be respected in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures (door, gates etc.), as well as from any deformation which might occur during use.
The installation must comply with the provisions set out by the following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments.
Disconnect the electrical power supply before carrying out any work on the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply, having a contact opening distance equal to or greater than 3mm.
Check that a differential switch with a 0.03A threshold is fitted just before the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for closure (doors, gates etc.) and all system components provided with an earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed to protect the area from any danger caused by squashing, conveying and shearing, according to and in compliance with the applicable directives and technical standards.
Position at least one luminous signal indication device (blinker) where it can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturers components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation area.
Keep radio control or other control devices out of childrens reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automation system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions, is not allowed.
2) GENERAL OUTLINE
This controller is suitable for residential use and has been designed for swing gates with particularly large gate posts. The drive arm, built with a special anti-shearing shape, allows the leaves to be moved when the controller is considerably out of place with respect to the fulcrum of the leaves. The non-reversible electro-mechanical gearmotor maintains the stop during closing and opening. The release lever, fitted in each controller
and situated inside the door fitted with personalised key, allows the manual manoeuvre to be easily carried out. WARNING! The installation, the maintenance and the repair should be done by responsible and qualified persons with an updated knowledge of the current safety standards. Its strictly forbidden to service the automation when the power is on. ATTENTION! The JOINT model controller is not equipped with mechanical torque adjustment. It is compulsory to use a control panel of the same manufacturer, in compliance with the basic safety requirements of directives 73/23/CEE, 89/336/CEE, 89/37/CEE equipped with appropriate electric adjusment of the torque.
3) TECHNICAL SPECIFICATIONS
Voltage: ....................................................................... 230V± 10% 50Hz (*)
Motor: .................................................................... Single-phase 1400min
-1
Power: ................................................................................................ 300W
Absorption: ........................................................ 1.7A (230V); 3,4A (110V)
Capacitor: ..................................... 10µF 450V (230V); 40µF 250V (110V)
Insulation class: ........................................................................................F
Thermal protection: .................................................... 130°C self-resetting
Lubrication: ................................................................... Permanent grease
Reduction ratio: ................................................................................. 1/812
Output revs.: .......................................................................... 1.7 min-1max
Output shaft: .................................................................20x20 hollow shaft
Opening time 90°: ................................................................................. 15s
Torque provided: ............................................................ 320Nm (~32kgm)
Max. leaf weight and length: ........... 2000N (~200kg) for 2.5m leaf length
............................................................ 2500N (~250kg) for 2m leaf length
Impact reaction: ................................... Electric clutch (with control panel)
Drive: ..........................................................................................Lever arm
Stopping:...................................................... Built-in electric limit-switches
Manual manoeuvre: ........................................ Door with personalised key
Number of manoeuvres: ................................................................ 100/24h
Working temperature: ....................................................... -15 C° ÷ +60 C°
Protection: ......................................................................................... IP 44
Controller weight: ................................................................. 160N (~16kg)
Dimensions: ..................................................................................See fig.1
*Special supply voltages on request buckle “M” of the operator. Refer to the relevant instruction manual for connection of the control panel.
4) INSTALLATION OF AUTOMATION
Preliminary checks Check:
- That the structure of the gate is rigid and strong enough. The fixing
position should be assessed according to the structure of the leaf. In any case, the manoeuvring arm must push against a reinforced point in the leaf (fig.2).
- That the leaves move manually for the whole of their stroke. If a new gate
is not being installed, check whether its components are worn. Repair or replace any worn or damaged parts. Automation reliability and safety are directly influenced by the condition of the gates structure.
5) FIXING OF SUPPORTING PLATE (Fig.2) The controller is supplied complete with anchoring bracket and lever arm. Once the reinforcement point of the leaf has been identified with the gate closed, draw an imaginary horizontal line from the centre of the reinforcement point to the gate post (fig.2). Position the anchoring bracket according to the values given in fig. 2 for openings of up to 90° or in fig.3 for openings greater than 90° up to a maximum of 125°. The bracket fixing position must be flat and parallel to the leaf. Use screws or expansion bolts which are suited to the type of gate post. If the surface of the gate post is not regular, use expansion bolts with studs so that the parallel plate of the leaf can be adjusted (fig.4).
- Fasten the gearmotor to the gate post using the 4 screws, pointing the
gearmotor to the left or the right (fig.5).
- Assemble the lever arm as shown in fig.6.
DX= assembly on the right leaf SX= assemby on the left leaf Choose the most suitable position of ‘F’ bracket for the fastening to the leaf.
- Insert the square of the first lever in the output shaft of the gearmotor and
fasten it (fig.7).
- Release the controller by activating the release lever so that the arm can
move easily (see the EMERGENCY MANOEUVRE paragraph).
- The correct position for the controller arm is shown in fig.8. The leaf
fixing point “A” can be identified by positioning the arm so that it is in accordance with the distance shown in fig.8.
- Fix the angular towing bar “A” to the leaf by welding or using screws.
- With the controller released, check the correct movement of the arm.