BFT IGEA LB-BT Installation And User Manual

D811384 ver.01 30-01-03
ATTUATORE PER PORTE A LIBRO ACTUATOR FOR FOLDING DOORS ACTIONNEUR POUR PORTES PLIANTES FALTTORANTRIEB SERVOMOTOR PARA PUERTAS DE LIBRILLO AUTOMATIZAÇÃO PARA PORTÕES QUE SE RECOLHEM SOBRE ELES MESMOS
GB
F
D
E
P
Via Lago di Vico, 44 36015 Schio (VI) Tel.naz. 0445 696511 Tel.int. +39 0445 696533 Fax 0445 696522 Internet: www.bft.it E-mail: sales@bft.it
IGEA LB-BT
  
INSTALLATION AND USER'S MANUAL
   
MONTAGE- und BEDIENUNGSANLEITUNG
   
INSTRUÇÕES DE USO E DE INSTALAÇÃO
4 -
IGEA LB-BT - Ver. 01
D811384_01
Thank you for buying this product. Our company is sure that you will be more than satisfied with the product’s performance. Carefully read the “WARNINGS” pamphlet and the “INSTRUCTION BOOKLET” which are supplied together with this product, since they provide important information regarding the safety, installation, use and maintenance of the product. This product complies with recognised technical standards and safety regulations. We declare that this product is in conformity with the following European Directives: 73/23/ EEC, 89/336/EEC, 98/37/EEC and subsequent amendments.
1) GENERAL OUTLINE
The IGEA LB-BT operator is suitable for motorising folding doors with a maximum of two panels for each controller (fig.1). Two controllers are needed for two pairs of panels. The non-reversible electro-mechanical gearmotor maintains the stop during closing and opening. WARNING! The installation, the maintenance and the repair should be done by responsible and qualified persons with an updated knowledge of the current safety standards. It’s strictly forbidden to service the automation when the power is on. ATTENTION! The IGEA LB-BT model controller is not equipped with mechanical torque adjustment. It is compulsory to use a control panel of the same manufacturer, in compliance with the basic safety requirements of directives 73/23/CEE, 89/336/CEE, 89/37/CEE equipped with appropriate electric adjusment of the torque.
USER’S MANUAL
ENGLISH
2) EMERGENCY MANOEUVRE
The emergency manoeuvre is carried out by means of a wire command, using one of the following accessories (Fig. 2): SEB, SET/S, SIBOX-MOX. For further information regarding their use and installation, make reference to the instructions for the individual accessories. Note: The knob available on this model can not be used for manual release. It is therefore essential to install one of the wire commands mentioned above.
WARNINGS Correct controller operation is only ensured when the data contained in the present manual are observed. The company is not to be held responsible for any damage resulting from failure to observe the installation standards and the instructions contained in the present manual.
The descriptions and illustrations contained in the present manual are not binding. The Company reserves the right to make any alterations deemed appropriate for the technical, manufacturing and commercial improvement of the product, while leaving the essential product features unchanged, at any time and without undertaking to update the present publication.
IGEA LB-BT- Ver. 01
- 11
D811384_01
INSTALLATION MANUAL ENGLISH
Thank you for buying this product. Our company is sure that you will be more than satisfied with the product’s performance. Carefully read the “WARNINGS” pamphlet and the “INSTRUCTION BOOKLET” which are supplied together with this product, since they provide important information regarding the safety, installation, use and maintenance of the product. This product complies with recognised technical standards and safety regulations. We declare that this product is in conformity with the following European Directives: 73/23/ EEC, 89/336/ EEC, 98/37/EEC and subsequent amendments.
1) GENERAL SAFETY WARNING! An incorrect installation or improper use of the product can cause damage to persons, animals or things.
• The “Warnings” leaflet and “Instruction booklet” supplied with this
product should be read carefully as they provide important information about safety, installation, use and maintenance.
• Scrap packing materials (plastic, cardboard, polystyrene etc) according to the provisions set out by current standards. Keep nylon or polystyrene bags out of children’s reach.
• Keep the instructions together with the technical brochure for future reference. This product was exclusively designed and manufactured for the use specified in the present documentation. Any other use not specified in this documentation could damage the product and be dangerous.
• The Company declines all responsibility for any consequences resulting from improper use of the product, or use which is different from that expected and specified in the present documentation.
• Do not install the product in explosive atmosphere.
• The construction components of this product must comply with the following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments. As for all non-EEC countries, the above­mentioned standards as well as the current national standards should be respected in order to achieve a good safety level.
• The Company declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures (door, gates etc.), as well as from any deformation which might occur during use.
• The installation must comply with the provisions set out by the following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments.
• Disconnect the electrical power supply before carrying out any work on the installation. Also disconnect any buffer batteries, if fitted.
• Fit an omnipolar or magnetothermal switch on the mains power supply, having a contact opening distance equal to or greater than 3mm.
• Check that a differential switch with a 0.03A threshold is fitted just before the power supply mains.
• Check that earthing is carried out correctly: connect all metal parts for closure (doors, gates etc.) and all system components provided with an earth terminal.
• Fit all the safety devices (photocells, electric edges etc.) which are needed to protect the area from any danger caused by squashing, conveying and shearing, according to and in compliance with the applicable directives and technical standards.
• Position at least one luminous signal indication device (blinker) where it can be easily seen, and fix a Warning sign to the structure.
• The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturers’ components are used.
• Only use original parts for any maintenance or repair operation.
• Do not modify the automation components, unless explicitly authorised by the company.
• Instruct the product user about the control systems provided and the manual opening operation in case of emergency.
• Do not allow persons or children to remain in the automation operation area.
• Keep radio control or other control devices out of children’s reach, in order to avoid unintentional automation activation.
• The user must avoid any attempt to carry out work or repair on the automation system, and always request the assistance of qualified personnel.
• Anything which is not expressly provided for in the present instructions, is not allowed.
2) GENERAL OUTLINE
The IGEA LB-BT operator is suitable for motorising folding doors with a maximum of two panels for each controller (fig.1). Two controllers are needed for two pairs of panels. The non-reversible electro-mechanical gearmotor maintains the stop during closing and opening. WARNING! The installation, the maintenance and the repair should be done by responsible and qualified persons with an updated knowledge of
the current safety standards. It’s strictly forbidden to service the automation when the power is on. ATTENTION! The IGEA LB-BT model controller is not equipped with mechanical torque adjustment. It is compulsory to use a control panel of the same manufacturer, in compliance with the basic safety requirements of directives 73/23/CEE, 89/336/CEE, 89/37/CEE equipped with appropriate electric adjusment of the torque.
3) TECHNICAL SPECIFICATIONS
Motor: .............................................................................. 24V 1500 min
-1
Power: .................................................................................................. 40W
Insulation class: ........................................................................................F
Lubrication: ................................................................... Permanent grease
Reduction radio: ............................................................................... 1: 812
Output shaft revolutions: ......................................................1.8 min
-1
MAX
90° opening time: ................................................................................. 15s
Torque supplied: ............................................................................ 300 Nm
Weight and max leaf length: ........... 2000N (~200kg) for 2.5m leaf length
2500N (~250kg) for 2m leaf length
Impact reaction: ............ Integrated torque limiter on LIBRA control panel
Motion drive: ...............................................................................Lever arm
Stop:.................................................... Incorporated electric limit switches
Manual manoeuvre: ......................... Release knob with personalised key
Number of manoeuvres in 24h: ............................................................ 100
Environmental conditions: ..................................................... -15 to +60°C
Degree of protection: ......................................................................... IP 4X
Operator weight: ...................................................................160N (~16kg)
Dimensions: ................................................................................ See fig. 1
4) INSTALLATION OF AUTOMATION
Preliminary checks. Check that the leaves move manually for the whole of their stroke. If a new gate is not being installed, check whether its components are worn. Repair or replace any worn or damaged parts. Automation reliability and safety are directly influenced by the condition of the gate’s structure.
5) POSITIONING
The expected standard position for fixing the IGEA LB-BT controller is illustrated in fig.1. The controller has to be fixed to the upper part of the panel hinged to the wall. However, if the overall dimensions do not allow this, it can be positioned on the panel which is not hinged to the wall (fig.4). The direction of fitting can be changed by rotating the actuator as shown in fig. 2 and using the required shaft output.
6) SUPPORT PLATE FIXING (fig.5) The controller is supplied with a fixing bracket and telescopic arm. Having identified the panel reinforcing point, weld or fix the anchoring bracket with screws, respecting the dimensions in fig.5. Fix the gearmotor to the plate with the 4 screws, in a right or left-handed position (fig.2).
7) TELESCOPIC ARM FIXING
With the door in the opening position (fig.6):
- insert the arm plate through the gearmotor output shaft and lock it using
the grub screw provided.
- Release the controller by operating the release lever in order to allow the
arm to move easily (see paragraph “EMERGENCY MANOEUVRE”).
- Fit the “S” bracket to the “BG” guide arm by means of the “P” pin
and splitpin.
- Insert the “BG” guide arm through the “BM” motor arm, respecting the
measurement in fig.6.
- Bring the “S” pivot bracket of the telescopic arm to its fixing position,
create an anchoring shim for the “S” bracket so that the telescopic arm becomes level (fig.6).
- The “BM” motor arm must protrude from the “BG” guide arm by the value
shown in fig.6.
- In case of narrow panels, the telescopic arm may need to be shortened.
- Check the door movement by hand.
- With the door closed, check that the “BM” motor arm is inserted far
enough into the “BG” guide arm (at least 70mm).
- Repeat the same operations to install the other controller.
8) ELECTRICAL INSTALLATION SETUP
Lay out the electrical installation with reference to the CEI 64-8 and IEC364 provisions complying with the HD384 and other national standards in force for electrical installation. Fit a type-approved omnipolar circuit breaker with at least 3mm contact opening, provided with protection against overloads and short circuits, suitable for cutting out automation from the mains, either entirely or by zones. Place, if not al ready installed, a type-approved