Beurer IH 25/1 Instructions For Use Manual

IH 25/1
Beurer GmbH Söflinger Str. 218 89077 Ulm, Germany Tel.: +49 (0)731 / 39 89 -144 Fax: +49 (0)731 / 39 89 - 255 www.beurer.com Mail: kd@beurer.de
D
Inhalator
Gebrauchsanweisung .............. 2 – 9
Nebuliser
Instructions for use ...............10 –16
Inhalateur
Mode d’emploi ...................... 17 – 24
E
Inhalador
Manual de instrucciones ...... 25 – 32
Inalatore
Istruzioni per l’uso ................ 33 – 40
T
Inhalatör
Kullanım kılavuzu ...................41– 47
r
Ингалятор
Инструкция по
применению ......................... 48 – 56
Q
Inhalator
Instrukcja obsługi ................. 57 – 64
Electromagnetic Compatibility
Information ................................. 65 – 66
0483
2
Lieferumfang
Siehe Geräte- und Zubehörbeschreibung S. 4.
Inhalator
Vernebler
Druckluftschlauch
Mundstück
Erwachsenenmaske
Kindermaske
Nasenstück
Ersatzfilter
Aufbewahrungstasche
Diese Gebrauchsanweisung
1. Kennenlernen
Sehr geehrte Kundin, sehr geehrter Kunde,
wir freuen uns, dass Sie sich für ein Produkt unseres Sortimentes entschieden haben. Unser Name steht für hochwertige und eingehend geprüfte Qualitätspro­dukte aus den Bereichen Wärme, Gewicht, Blutdruck, Körpertemperatur, Puls, Sanfte Therapie, Massage und Luft. Bitte lesen Sie diese Gebrauchsanweisung aufmerk­sam durch, bewahren Sie sie für späteren Gebrauch auf, machen Sie sie anderen Benutzern zugänglich und beachten Sie die Hinweise.
Mit freundlicher Empfehlung Ihr Beurer-Team
Anwendungsbereich
Dieser Inhalator ist ein Inhalationsgerät zur Verneb­lung von Flüssigkeiten und flüssigen Medikamenten (Aerosolen) und für die Behandlung der oberen und unteren Atemwege.
Durch Verneblung und Inhalation des vom Arzt verord­neten bzw. empfohlenen Medikaments können Sie Er­krankungen der Atemwege vorbeugen, deren Begleit-
DEUTSCH
1. Kennenlernen ......................................................2
2. Zeichenerklärung .................................................2
3. Warn-und Sicherheitshinweise ............................3
4. Geräte- und Zubehör beschreibung .....................4
5. Inbetriebnahme ...................................................5
6. Bedienung ...........................................................5
7. Filterwechsel .......................................................6
8. Reinigung und Desinfektion ................................6
9. Entsorgen ............................................................8
10. Problemlösung ....................................................8
11. Technische Angaben ...........................................9
12. Garantie und Service ...........................................9
Inhalt
erscheinungen mildern und die Heilung beschleunigen. Weitere Auskünfte über die Einsatzmöglichkeiten erfah­ren Sie durch Ihren Arzt oder Apotheker.
Das Gerät ist für die Inhalation zu Hause geeignet. Die Medikamenteninhalation sollte nur nach ärztlicher Anweisung erfolgen. Nehmen Sie die Inhalation ruhig und entspannt vor und atmen Sie langsam und tief ein, damit das Medikament bis in die feinen, tief liegenden Bronchien gelangen kann. Atmen Sie normal aus.
Das Gerät ist nach Aufbereitung für den Wiederein­satz geeignet. Die Aufbereitung umfasst den Austausch sämtlicher Zubehörteile inklusive Vernebler und Luft­filter sowie eine Geräteoberflächendesinfektion mit einem handelsüblichen Desinfektionsmittel.
2. Zeichenerklärung
Folgende Symbole werden in der Gebrauchsanweisung verwendet:
Warnung Warnhinweis auf Verletzungs-
gefahren oder Gefahren für Ihre Gesundheit.
Achtung Sicherheitshinweis auf mögliche
Schäden am Gerät/Zubehör.
Hinweis
Hinweis auf wichtige Informationen.
Auf der Verpackung und auf dem Typenschild des Gerätes und des Zubehörs werden folgende Symbole verwendet:
Anwendungsteil Typ BF
Gebrauchsanweisung beachten
Gerät der Schutzklasse 2
H
ersteller
I
Ein
O
Aus
SN
Seriennummer
IP 21
Geschützt gegen Fremdkörper ≥12,5 mm und gegen senkrechtes Tropfwasser
3
3. Warn- und Sicherheitshinweise
Warnung
Vor dem Gebrauch ist sicherzustellen, dass das
Gerät und Zubehör keine sichtbaren Schäden auf­weisen. Benutzen Sie es im Zweifelsfall nicht und wenden Sie sich an Ihren Händler oder an die ange­gebene Kundendienstadresse.
Eine Anwendung des Gerätes ersetzt keine ärztliche
Konsultation und Behandlung. Befragen Sie bei je­der Art von Schmerz oder Krankheit deshalb immer zunächst Ihren Arzt.
Bei gesundheitlichen Bedenken irgendwelcher Art
konsultieren Sie Ihren Hausarzt!
Beachten Sie beim Einsatz des Verneblers die allge-
meinen Hygienemaßnahmen.
Für den Typ des zu verwendenden Medikamentes,
die Dosierung, die Häufigkeit und die Dauer der In­halation sind immer die Anweisungen des Arztes zu befolgen.
Verwenden Sie nur Medikamente, die von Ihrem Arzt
oder Apotheker verordnet oder empfohlen wurden.
Sollte das Gerät nicht korrekt funktionieren, sich Un-
wohlsein oder Schmerzen einstellen, brechen Sie die Anwendung sofort ab.
Halten Sie das Gerät während des Gebrauchs von Ih-
ren Augen entfernt, der Medikamentennebel könnte schädigend wirken.
Betreiben Sie das Gerät nicht bei Vorhandensein von
brennbaren Gasen.
Dieses Gerät ist nicht dafür bestimmt, durch Kinder
oder Personen mit eingeschränkten physischen, sensorischen (z.B. Schmerzunempfindlichkeit) oder geistigen Fähigkeiten oder mangels Erfahrung und/ oder mangels Wissen benutzt zu werden. Es sei denn, sie werden durch eine für Ihre Sicherheit zu­ständige Person beaufsichtigt oder erhielten von ihr Anweisungen, wie das Gerät zu benutzen ist.
Halten Sie Kinder vom Verpackungsmaterial fern
(Erstickungsgefahr).
Benutzen Sie keine Zusatzteile, die nicht vom Her-
steller empfohlen werden.
Das Gerät darf nur an die auf dem Typschild ange-
gebene Netzspannung angeschlossen werden.
Tauchen Sie das Gerät nicht in Wasser und verwen-
den Sie es nicht in Nassräumen. Es dürfen keinesfalls Flüssigkeiten in das Gerät eindringen.
Schützen Sie das Gerät vor stärkeren Stößen.
Fassen Sie die Netzleitung niemals mit nassen Hän-
den an, Sie könnten einen Stromschlag erleiden.
Den Netzstecker nicht an der Netzleitung aus der
Steckdose herausziehen.
Die Netzleitung nicht einklemmen, knicken, über
scharfkantige Gegenstände ziehen, nicht herunter­hängen lassen sowie vor Hitze schützen.
Bei Beschädigungen der Netzleitung und des Ge-
häuses wenden Sie sich an den Kundenservice oder Händler.
Beim Öffnen des Gerätes besteht die Gefahr eines
elektrischen Schlages. Die Trennung vom Versor­gungsnetz ist nur gewährleistet, wenn der Netzste­cker aus der Steckdose gezogen ist.
Wenn das Gerät heruntergefallen ist, extremer Feuch-
tigkeit ausgesetzt wurde oder anderweitige Schäden davongetragen hat, darf es nicht mehr benutzt wer­den. Setzen Sie sich im Zweifelsfall mit dem Kunden­service oder Händler in Verbindung.
Der IH 25/1 Inhalator darf nur mit dafür passenden
Beurer Verneblern und mit entsprechendem Beurer Zubehör betrieben werden. Die Verwendung von Fremdverneblern und -Zubehör kann zur Beeinträch­tigung der Therapieeffizienz führen und gegebenen­falls das Gerät beschädigen.
Achtung
Stromausfall, plötzliche Störungen bzw. andere un-
günstige Bedingungen könnten zur Betriebsunfä­higkeit des Geräts führen. Deshalb wird empfohlen, über ein Ersatzgerät bzw. ein (mit dem Arzt abge­sprochenes) Medikament zu verfügen.
Sollten Adapter oder Verlängerungen erforderlich
sein, müssen diese den geltenden Sicherheitsvor­schriften entsprechen. Die Stromleistungsgrenze sowie die auf dem Adapter angegebene Maximallei­stungsgrenze dürfen nicht überschritten werden.
Das Gerät und das Versorgungskabel darf nicht in
der Nähe von Wärmequellen aufbewahrt werden.
Das Gerät darf nicht in Räumen verwendet werden,
in denen zuvor Sprays verwendet wurden. Vor der Therapie sind diese Räume zu lüften.
Keine Gegenstände in die Kühlungsöffnungen ge-
langen lassen.
Das Gerät nie verwenden, wenn es ein anormales
Geräusch verursacht.
Es ist aus hygienischen Gründen unbedingt erfor-
derlich, dass jeder Benutzer sein eigenes Zubehör verwendet.
Nach dem Gebrauch immer den Netzstecker ziehen.
Das Gerät an einem vor Witterungseinflüssen ge-
schützten Ort aufbewahren. Das Gerät muss bei den vorgesehenen Umgebungsverhältnissen aufbewahrt werden.
SICHERUNG
Im Gerät befindet sich eine Überstromsicherung.
Diese darf nur vom autorisierten Fachpersonal ge­wechselt werden.
Das Gerät verfügt außerdem über eine thermische
Sicherung, welche bei Überhitzung den Inhalator
4
abschaltet. Sollte dies geschehen gehen Sie bitte folgendermaßen vor: – Schalten Sie das Gerät aus. – Ziehen Sie den Netzstecker. – Warten Sie mind. 30 Minuten bis das Gerät voll-
ständig abgekühlt ist.
– Schalten Sie das Gerät danach wieder ein, achten
Sie darauf, ob es anormale Geräusche von sich gibt. Ist das nicht der Fall können Sie das Gerät wieder verwenden, andernfalls wenden Sie sich bitte an den angegebenen Kundendienst.
Allgemeine Hinweise
Achtung
Verwenden Sie das Gerät ausschließlich:
– am Menschen, – für den Zweck, für den es entwickelt wurde (Aero-
solinhalation) und auf die in dieser Gebrauchsan­weisung angegebene Art und Weise.
Jeder unsachgemäße Gebrauch kann gefährlich
sein!
Bei akuten Notfällen hat die Erste Hilfe Vorrang.
Verwenden Sie neben den Medikamenten nur de-
stilliertes Wasser bzw. eine Kochsalzlösung. Andere Flüssigkeiten führen unter Umständen zu einem De­fekt des Inhalators bzw. Verneblers.
Dieses Gerät ist nicht für den gewerblichen oder kli-
nischen Gebrauch bestimmt, sondern ausschließlich zur Eigenanwendung im privaten Haushalt!
Vor Inbetriebnahme
Achtung
Vor Gebrauch des Gerätes ist jegliches Verpackungs-
material zu entfernen.
Schützen Sie das Gerät vor Staub, Schmutz und
Feuchtigkeit, decken Sie das Gerät auf keinen Fall während des Betriebes ab.
Betreiben Sie das Gerät nicht in stark staubbelasteter
Umgebung.
Schalten Sie das Gerät sofort aus, wenn es defekt
ist oder Betriebsstörungen vorliegen.
Der Hersteller haftet nicht für Schäden, die durch
unsachgemäßen oder falschen Gebrauch verursacht wurden.
Reparatur
Hinweis
Sie dürfen das Gerät keinesfalls öffnen oder repa-
rieren, da sonst eine einwandfreie Funktion nicht mehr gewährleistet ist. Bei Nichtbeachten erlischt die Garantie.
Wenden Sie sich bei Reparaturen an den Kunden-
service oder an einen autorisierten Händler.
4. Geräte- und Zubehör­beschreibung
Übersicht Inhalator
1 Tragegriff 2 Ein-/Aus-Schalter (Rückseite) 3 Netzanschlusskabel 4 Schlauchanschluss 5 Filterkappe mit Filter 6 Halterung für Vernebler
Übersicht Vernebler und Zubehör
7 Druckluftschlauch 8 Vernebler 9 Verneblereinsatz 10 Medikamentenbehälter 11 Mundstück 12 Nasenstück 13 Erwachsenenmaske 14 Kindermaske 15 Ersatzfilter 16 Aufbewahrungstasche
3
1
2
6
4
5
7
8
9
10
15
16
14
13
12
11
5
5. Inbetriebnahme
Aufstellen
Entnehmen Sie das Gerät der Verpackung. Stellen Sie es auf einer ebenen Fläche auf. Achten Sie darauf, dass die Lüftungsschlitze frei sind.
Vor der ersten Verwendung
Hinweis
Vor der ersten Nutzung sollte der Vernebler und das
Zubehör gereinigt und desinfiziert werden. Siehe hierzu „Reinigung und Desinfektion“ S. 6.
Stecken Sie den Druckluftschlauch [7] unten an den
Medikamentenbehälter [10].
Stecken Sie das andere Ende des Schlauchs [7] mit
leichter Drehung in den Schlauchanschluss [4] des Inhalators.
Netzanschluss
Das Gerät nur an die auf dem Typschild angegebene Netzspannung anschließen.
Stecken Sie den Netzstecker des Netzkabels [3] in
eine geeignete Steckdose.
Zur Netzverbindung den Stecker vollständig in die
Steckdose stecken.
Hinweis
Achten Sie darauf, dass sich eine Steckdose in der
Nähe des Aufstellplatzes befindet.
Verlegen Sie das Netzkabel so, dass niemand darü-
ber stolpern kann.
Zur Trennung des Inhalators vom Stromnetz nach
der Inhalation schalten Sie zuerst das Gerät aus und ziehen Sie dann den Netzstecker aus der Steckdose.
6. Bedienung
Achtung
Aus hygienischen Gründen ist es unbedingt erforder-
lich, den Vernebler [8] sowie das Zubehör nach jeder Behandlung zu reinigen und nach der täglich letzten Behandlung zu desinfizieren.
Sollten bei der Therapie mehrere verschiedene Medi-
kamente nacheinander inhaliert werden, so ist zu beachten, dass der Vernebler [8] nach jeder Anwen­dung unter warmem Leitungswasser durchgespült wird. Siehe hierzu „Reinigung und Desinfektion“ auf Seite 6.
Beachten Sie die Hinweise zum Filterwechsel in die-
ser Gebrauchsanweisung!
Überprüfen Sie vor jeder Verwendung des Gerätes
den festen Sitz der Schlauchanschlüsse am Inhalator [4] und am Vernebler [8].
Prüfen Sie vor der Benutzung das Gerät auf ord-
nungsgemäße Funktion, hierfür schalten Sie den Inhalator (samt angeschlossenem Vernebler, aber ohne Medikamente) für einen kurzen Moment ein. Wenn hierbei Luft aus dem Vernebler [8] kommt, funktioniert das Gerät.
1. Vernebler befüllen
Öffnen Sie den Deckel des Verneb-
lers [8].
Füllen Sie eine isotonische Koch-
salzlösung oder das Medikament direkt in den Vernebler [8]. Vermei­den Sie eine Überfüllung! Die maxi­mal empfohlene Füllmenge beträgt 8 ml !
• Verwenden Sie Medikamente nur
auf Anweisung Ihres Arztes und fragen Sie nach der für Sie angemessenen Inhalationsdauer und -menge!
Liegt die vorgegebene Menge des Medikamentes
bei weniger als 2 ml, füllen Sie diese Menge mit iso­tonischer Kochsalzlösung auf mind. 4 ml auf. Eine Verdünnung ist bei zähflüssigen Medikamenten ebenfalls notwendig. Achten Sie auch hier auf die Anweisung Ihres Arztes.
2. Vernebler schließen
Schließen Sie den Deckel des Verneblers [8].
6
3. Zubehör mit Vernebler verbinden
Vernebler [8] mit gewünschtem Zubehör (Mundstück
[11], Nasenstück [12], Erwachsenenmaske [13] oder Kindermaske [14]) verbinden.
Ziehen Sie den Vernebler vor der Behandlung nach
oben aus der Halterung [6] heraus.
Starten Sie den Inhalator mit dem Ein-/Aus-Schalter
[2].
Das Ausströmen des Sprühnebels aus dem Vernebler
zeigt den einwandfreien Betrieb.
4. Behandlung
Atmen Sie das zerstäubte Medikament tief ein.
Hinweis
Halten Sie den Vernebler während der Behandlung ge­rade (senkrecht), da ansonsten die Zerstäubung nicht funktioniert und eine einwandfreie Funktion nicht ge­währleistet ist.
Achtung
Ätherische Heilpflanzenöle, Hustensäfte, Lösungen zum Gurgeln, Tropfen zum Einreiben oder für Dampf­bäder sind grundsätzlich ungeeignet für die Inhalation mit Inhalatoren. Diese Zusätze sind oft zähflüssig und können die korrekte Funktion des Gerätes und damit die Wirksamkeit der Anwendung nachhaltig beeinträch­tigen. Bei einer Überempfindlichkeit des Bronchialsy­stems können Medikamente mit ätherischen Ölen un­ter Umständen einen akuten Bronchospasmus (eine plötzliche krampfartige Einengung der Bronchien mit Atemnot) auslösen. Fragen Sie dazu Ihren Arzt oder Apotheker!
5. Inhalation beenden
Tritt der Nebel nur noch unregelmäßig aus oder verän­dert sich das Geräusch bei der Inhalation können Sie die Behandlung beenden.
Schalten Sie den Inhalator nach der Behandlung mit
dem Schalter [2] aus und trennen Sie ihn vom Strom­netz.
Setzen Sie den Vernebler [8] nach der Behandlung
wieder zurück in seine Halterung [6].
6. Reinigung durchführen
Siehe „Reinigung und Desinfektion“ auf Seite 6.
7. Filterwechsel
Überprüfen Sie bitte nach jeder 10. Anwendung den Filter. Ist er stark verschmutzt oder verstopft, wechseln Sie den gebrauchten Filter aus. Sollte der Filter feucht geworden sein, muss er ebenfalls gegen einen neuen Filter ausgewechselt werden.
Achtung
Versuchen Sie nicht, den gebrauchten Filter zu rei-
nigen und wieder zu verwenden!
Benutzen Sie ausschließlich den Original-Filter des
Herstellers, da ansonsten Ihr Inhalator beschädigt werden könnte oder keine ausreichend effektive Therapie sichergestellt werden kann.
Gerät niemals ohne Filter betreiben.
Zum Auswechseln des Filters gehen Sie folgender­maßen vor:
Achtung
Gerät erst ausschalten und vom Netz trennen.
Gerät abkühlen lassen.
1. Filterkappe [5] gegen
den Uhrzeigersinn dre­hen und nach vorne ab­ziehen.
Hinweis
Falls der Filter nach Abziehen der Kappe im Gerät ver­bleibt, entfernen Sie den Filter, z.B. mit einer Pinzette oder Ähnlichem, aus dem Gerät.
2. Filterkappe [5] mit neuem Filter wieder einsetzen,
hierfür die Kappe einsetzen und im Uhrzeigersinn drehen, bis diese fühlbar einrastet.
3. Festen Sitz prüfen.
8. Reinigung und Desinfektion
Vernebler und Zubehör
Warnung
Befolgen Sie nachfolgende Hygienevorschriften, um eine Gesundheitsgefährdung zu vermeiden.
Vernebler [8] und Zubehör sind für eine Mehrfach-
verwendung vorgesehen. Bitte beachten Sie, dass für die unterschiedlichen Anwendungsbereiche verschiedene Anforderungen an die Reinigung und hygienische Wiederaufbereitung gestellt werden.
Hinweise:
Eine mechanische Reinigung des Verneblers sowie
des Zubehörs mit Bürsten oder dergleichen muss unterbleiben, da hierbei irreparable Schäden die Fol­ge sein können und ein gezielter Behandlungserfolg nicht mehr gewährleistet ist.
Die zusätzlichen Anforderungen bezüglich der not-
wendigen hygienischen Vorbereitung (Handpflege, Handhabung der Medikamente bzw. der Inhalations­lösungen) bei Hochrisikogruppen (z.B. Mukoviszido­sepatienten) erfragen Sie bitte bei Ihrem Arzt.
1
2
7
Achten Sie auf ausreichende Trocknung nach jeder
Reinigung, Desinfektion. Eine Restfeuchtigkeit bzw. Restnässe kann ein erhöhtes Risiko für Keimwachs­tum darstellen.
Vorbereitung
Direkt nach jeder Behandlung müssen alle Teile
des Verneblers [8] sowie das benutzte Zubehör von Medi kamentenresten und Verunreinigungen gereinigt werden.
Hierfür zerlegen Sie den Vernebler [8] in seine Einzel-
teile.
Ziehen Sie das Mundstück [11] vom
Vernebler ab.
Zerlegen Sie den Vernebler, indem
Sie den Verneblereinsatz [9] im Ge­genuhrzeigersinn gegen den Medika­mentenbehälter [10] drehen und nach oben abziehen.
• Der Zusammenbau erfolgt später
sinn gemäß in umgekehrter Reihenfolge.
Reinigung
Achtung
Vor jeder Reinigung muss das Gerät ausgeschaltet, vom Netz getrennt und abgekühlt sein.
Der Vernebler sowie das benutzte Zubehör wie Mund- stück, Maske, usw. müssen nach jeder Anwendung mit heißem Wasser gereinigt werden. Trocknen Sie die Teile sorgfältig mit einem weichen Tuch ab. Setzen Sie die Teile, wenn diese vollständig getrocknet sind, wieder zusammen und legen Sie die Teile in ein trockenes, ab­gedichtetes Behältnis oder führen Sie die Desinfektion durch.
Vergewissern Sie sich bei der Reinigung, dass jegliche Rückstände entfernt werden. Verwenden Sie dabei auf keinen Fall Substanzen, die bei der Berührung mit der Haut oder den Schleimhäuten, verschluckt oder inha­liert potenziell giftig sein könnten.
Benutzen Sie zur Reinigung des Gerätes ein feuchtes Tuch, auf das Sie bei Bedarf etwas Spülmittel auftra­gen können.
Benutzen Sie keine scharfen Reinigungsmittel und hal­ten Sie das Gerät niemals unter Wasser.
Achtung
Achten Sie darauf, dass kein Wasser in das Geräte-
innere gelangt!
Gerät und Zubehör nicht in der Spülmaschine reini-
gen!
Das Gerät darf im angeschlossenen Zustand nicht
mit feuchten Händen angefasst werden; es darf kein
Wasser auf das Gerät spritzen. Das Gerät darf nur im vollständig trockenen Zustand betrieben werden.
Sprühen Sie keine Flüssigkeit in die Lüftungsschlitze!
Eingedrungene Flüssigkeiten können eine Beschä­digung der Elektrik sowie anderer Inhalatorteile ver­ursachen und zu einer Funktionsstörung führen.
Kondenswasser, Schlauchpflege
Je nach Umgebungsbedingungen kann sich im Schlauch Kondens wasser absetzen. Um Keimwachs­tum vorzubeugen und eine einwandfreie Therapie zu gewährleisten, ist die Feuchtigkeit unbedingt zu entfer­nen. Gehen Sie dazu folgendermaßen vor:
Ziehen Sie den Schlauch [7] vom Vernebler [8] ab.
Lassen Sie den Schlauch inhalatorseitig [4] einge-
steckt.
Nehmen Sie den Inhalator so lange in Betrieb, bis die
Feuchtigkeit durch die durchströmende Luft beseitigt ist.
Bei starken Verschmutzungen ersetzen Sie den
Schlauch.
Desinfektion
Bitte folgen Sie den unten aufgeführten Punkten sorg­fältig, um Ihren Vernebler und das Zubehör zu desin­fizieren. Es wird empfohlen, die Einzelteile spätestens nach der täglich letzten Benutzung zu desinfizieren.
Reinigen Sie zunächst den Vernebler und das Zube-
hör wie unter „Reinigung“ beschrieben.
Der Vernebler sollte wie beschrieben zerlegt werden
und zusammen mit dem Mundstück und Nasenstück für mindestens 10 Minuten in sprudelnd kochendes Wasser gelegt werden. Der Kontakt der Teile mit dem heißen Topfboden sollte hierbei vermieden werden.
Sie können den Vernebler, das Mundstück und
das Nasenstück auch mit einem handelsüblichen Vaporisator desinfizieren. Beachten Sie hierzu die Gebrauchsanweisung des Vaporisator-Herstellers.
Hinweis
Die Gesichtsmasken und der Luftschlauch dürfen nicht in heißes Wasser gelegt werden!
Trocknen Sie die Teile sorgfältig mit einem weichen
Tuch ab.
Wir empfehlen Ihnen, die Masken mit einem handels-
üblichen Desinfektionsmittel zu desinfizieren.
Setzen Sie die Teile, wenn diese vollständig getrock-
net sind, wieder zusammen und legen Sie die Teile in ein trockenes, abgedichtetes Behältnis.
Hinweis
Bitte beachten Sie, dass bei oder speziell nach der Reinigung die Teile vollständig getrocknet sind, da an­sonsten hier das Risiko von Keimwachstum erhöht ist.
8
Trocknung
Legen Sie die Einzelteile auf eine trockene, saubere
und saugfähige Unterlage und lassen Sie sie voll­ständig trocknen (mindestens 4 Stunden).
Materialbeständigkeit
Vernebler und Zubehör unterliegen bei häufiger
Anwendung und hygienischer Wiederaufbereitung, wie jedes andere Kunststoffteil auch, einer gewis­sen Abnutzung. Dies kann im Laufe der Zeit zu einer Veränderung des Aerosols und somit auch zu einer Beeinträchtigung der Therapieeffizienz führen. Wir empfehlen deshalb, den Vernebler spätestens nach einem Jahr auszuwechseln.
Bei der Wahl der Reinigungs- bzw. Desinfektions-
mittel ist Folgendes zu beachten: Verwenden Sie nur ein mildes Reinigungsmittel oder Desinfektionsmittel, welches Sie nach Herstellerangaben dosieren.
Lagerung
Nicht in Feuchträumen (z.B. Badezimmer) lagern und
zusammen mit feuchten Gegenständen transportie­ren.
Vor anhaltender direkter Sonneneinstrahlung ge-
schützt lagern und transportieren.
Aufbewahrung
Das Gerät kann mitsamt allem Zubehör, wie z.B.
Vernebler, Masken, in der Aufbewahrungstasche verstaut werden.
9. Entsorgen
Im Interesse des Umweltschutzes darf das Gerät nicht mit dem Hausmüll entsorgt werden. Bitte entsorgen Sie das Gerät gemäß der Elektro­und Elektronik Altgeräte EG-Richtlinie – WEEE (Waste Electrical and Electronic Equipment). Bei Rückfragen wenden Sie sich bitte an die für die Entsorgung zuständige kommunale Behörde.
10. Problemlösung
Probleme/ Fragen
Mögliche Ursache/Behebung
Der Vernebler erzeugt kein oder zu wenig Aerosol.
1. Zu viel oder zu wenig Medikament im Vernebler. Minimum: 0,5 ml, Maximum: 8 ml.
2. Düse auf Verstopfung prüfen. Gegebenenfalls Düse reinigen (z.B. durch Ausspülen). Vernebler danach erneut in Betrieb nehmen. ACHTUNG: Die feinen Bohrungen nur von der Düsenunterseite vor­sichtig durchstechen.
3. Vernebler nicht senkrecht gehalten.
Probleme/ Fragen
Mögliche Ursache/Behebung
Der Vernebler erzeugt kein oder zu wenig Aerosol.
4. Ungeeignete Medikamentenflüssig­keit zum Vernebeln eingefüllt (z.B. zu dickflüssig). Die Medikamentenflüssigkeit sollte vom Arzt vorgegeben werden.
Der Ausstoß ist zu gering.
Geknickter Schlauch, verstopfter Filter, zu viel Inhalationslösung.
Welche Medikamente kann man inhalieren?
Bitte fragen Sie hierzu Ihren Arzt.
Grundsätzlich können alle Medika­mente, die für eine Geräte-Inhalation geeignet und zugelassen sind, inha­liert werden.
Es bleibt Inha­lationslösung im Vernebler zurück.
Dies ist technisch bedingt und normal. Beenden Sie die Inhalation, sobald Sie ein deutlich verändertes Verneblergeräusch hören.
Was ist bei Babys und Kindern zu beachten?
1. Bei Babys sollte die Maske Mund und Nase abdecken um eine effek­tive Inhalation zu gewährleisten.
2.
Bei Kindern sollte ebenfalls die Maske Mund und Nase ab decken. Eine Verneblung neben schlafenden Personen ist wenig sinnvoll, da hierbei nicht genügend des Medika­ments in die Lunge gelangen kann.
Hinweis: Es sollte nur unter Aufsicht und mit Hilfe einer erwachsenen Person inhaliert werden und das Kind nicht allein gelassen werden.
Die Inhalation mit der Maske dauert länger?
Dies ist technisch bedingt. Durch die Maskenlöcher atmen Sie pro Atemzug weniger Medikament ein als über das Mundstück. Das Aerosol wird über die Löcher mit Raumluft vermischt.
Warum soll der Vernebler regelmäßig ausgewechselt werden?
Dafür gibt es zwei Gründe:
1. Um ein therapeutisch wirksames Teilchenspektrum zu gewährlei­sten, soll die Düsenbohrung einen bestimmten Durchmesser nicht überschreiten. Bedingt durch mechanische und thermische Be­anspruchung unterliegt der Kunst­stoff einem gewissen Verschleiß. Der Vernebler [8] ist besonders sensibel. Damit kann sich auch die Tröpfchenzusammensetzung des Aerosols verändern, was unmittel­bar die Effektivität der Behandlung beeinflusst.
2. Zudem wird ein regelmäßiger Wechsel des Verneblers aus hygie­nischen Gründen empfohlen.
Benötigt jeder seinen eigenen Vernebler?
Aus hygienischer Sicht ist dies unbe­dingt notwendig.
9
11. Technische Angaben
Abmessungen (B x H x T) 166 x 141 x 148 mm
Gewicht 1,4 kg Arbeitsdruck ca. 1,0 bar Füllvolumen
Vernebler max. 8 ml Medikamenten-
fluss ca. 0,22 ml/min. Schalldruck max. 60 dBA (gem. DIN EN 13544-1) Netzanschluss 230 V ~, 50 Hz; 180 VA Gehäusematerial ABS/PP Betriebs-
bedingungen
Temperatur: +10 °C bis +40 °C Relative Luftfeuchte: 10% bis 90%
Lager- und Trans­portbedingungen
Temperatur: -25 °C bis +60 °C Relative Luftfeuchte: 10% bis 90% Umgebungsdruck: 500 bis 1060 hPa
Technische Änderungen vorbehalten.
Die Messungen wurden mit einer Natrium-Chlorid-Lö­sung mittels Laser-Diffraktions-Methode durchgeführt. Das Diagramm ist möglicherweise so nicht auf Suspen­sionen oder sehr zähflüssige Medikamente anwendbar. Nähere Informationen dazu können Sie vom jeweiligen Medikamentenhersteller erfahren.
Nachkaufartikel
Bezeichnung Material REF
Vernebler-Stopper PP
162.819
Yearpack (enthält Mundstück, Erwach senenmaske, Kinder­maske, Vernebler, Druckluft­schlauch, Filter, Nasenstück)
PP/ PVC 601.03
Hinweis
Bei Verwendung des Gerätes außerhalb der Spezifi­kation ist eine einwandfreie Funktion nicht gewährlei­stet! Technische Änderungen zur Verbesserung und Weiterentwicklung des Produktes behalten wir uns vor. Dieses Gerät und dessen Zubehör entspricht den europäischen Normen EN60601-1 und EN60601-1-2 sowie EN13544-1 und unterliegt besonderen Vorsichts-
maßnahmen hinsichtlich der elektromagnetischen Ver­träglichkeit. Bitte beachten Sie dabei, dass tragbare und mobile HF-Kommunikationseinrichtungen dieses Gerät beeinflussen können. Genauere Angaben können Sie unter der angegebenen Kundenservice-Adresse anfordern oder am Ende der Gebrauchsanweisung nachlesen. Das Gerät entspricht den Anforderun­gen der europäischen Richtlinie für Medizinprodukte 93/42/EC, dem Medizinproduktegesetz.
ELEKTROMAGNETISCHE KOMPATIBILITÄT
Das Gerät entspricht den zurzeit geltenden Vorschrif-
ten in Bezug auf die elektromagnetische Kompatibili­tät und ist geeignet für die Verwendung in sämtlichen Gebäuden, einschließlich derjenigen, die für private Wohnzwecke bestimmt sind. Die Radiofrequenze­missionen des Geräts sind äußerst niedrig und verursachen mit größter Wahrscheinlichkeit keine Interferenzen mit anderen Geräten in der Nähe.
Es empfiehlt sich auf jeden Fall, das Gerät nicht über
oder nahe bei anderen Geräten aufzustellen. Sollte es mit Ihren Elektrogeräten zu Interferenzen kommen, verstellen Sie es oder schließen Sie es an eine andere Steckdose an.
Funkgeräte könnten den Betrieb des Geräts beein-
flussen.
12. Garantie und Service
Wir gewähren 3 Jahre Garantie auf Material- und Fabri­kationsfehler des Produktes. Die Garantie gilt nicht:
im Falle von Schäden, die auf unsachgemäßer Be-
dienung beruhen,
für Verschleißteile (z.B. Vernebler, Filter, Druckluft-
schlauch etc.),
für Mängel, die dem Kunden bereits bei Kauf bekannt
waren,
bei Eigenverschulden des Kunden.
Die gesetzlichen Gewährleistungen des Kunden blei­ben durch die Garantie unberührt. Für Geltendmachung eines Garantiefalles innerhalb der Garantiezeit ist durch den Kunden der Nachweis des Kaufes zu führen. Die Garantie ist innerhalb eines Zeitraumes von 3 Jah­ren ab Kaufdatum gegenüber der Beurer GmbH, Söf­linger Straße 218, 89077 Ulm, Deutschland, geltend zu machen. Der Kunde hat im Garantiefall das Recht zur Reparatur der Ware bei unserem eigenen oder bei von uns autorisierten Werkstätten. Weitergehende Rechte werden dem Kunden (aufgrund der Garantie) nicht eingeräumt.
100
50
0
0.20 1.00 10.00
Particle Diameter (μm)
Cumulative Volume (%)
50.00
10
ENGLISH
Included in delivery
For details of the delivery scope, see description of the device and accessories on page 12.
Nebuliser
Atomiser
Compressed air hose
Mouthpiece
Adult mask
Child mask
Nosepiece
Spare filter
Storage bag
These instructions for use
1. Getting to know your instrument
Dear customer
Thank you for choosing one of our products. Our name stands for high-quality, thoroughly tested products for applications in the areas of heat, weight, blood pres­sure, body temperature, pulse, gentle therapy, mas­sage and air. Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.
With kind regards Your Beurer team
Area of application
This nebuliser is a device used for the nebulisation of liquids and liquid medication (aerosols) and for the treatment of the upper and lower respiratory tract. The nebulisation and inhalation of medication pre­scribed or recommended by a doctor can prevent against diseases of the respiratory tract, treat the side effects of these disorders and accelerate healing.
1. Getting to know your instrument .......................10
2. Signs and symbols ............................................10
3. Safety information and warnings .......................10
4. Description of device and accessories .............12
5. Initial use ...........................................................12
6. Operation ...........................................................13
7. Changing the filter .............................................14
8. Cleaning and disinfection ..................................14
9. Disposal .............................................................15
10. Troubleshooting .................................................15
11. Technical specifications ....................................16
Contents
For more information on possible applications, consult your doctor or pharmacist.
The device is suitable for inhalation at home. Medicines should only be inhaled when instructed by a doctor. Inhalation should be performed in a calm and relaxed atmosphere. Inhale slowly and deeply to enable the medicine to reach the small bronchi deep into the lungs. Exhale normally.
Once prepared, the device is suitable for reuse. The preparation includes the replacement of all accessory parts including atomiser and air filter, as well as disin­fection of the surfaces of the device with a standard disinfectant.
2. Signs and symbols
The following symbols appear in these instructions.
Warning Warning instruction indicating a
risk of injury or damage to health.
Important Safety note indicating possible
damage to the unit/accessory.
Note
Note on important information.
The following symbols are used on the packaging and on the nameplate of the device and accessories.
Type BF applied part
Follow instructions for use
Device in protection class 2
M
anufacturer
I
On
O
Off
SN
Serial number
IP 21
Protected against foreign objects equal to or greater than 12.5 mm in diameter and against vertically falling drops of water
3. Safety information and warnings
Warning
Before use, ensure that there is no visible damage to
the unit or accessories. When in doubt, do not use the unit and contact your dealer or the customer service address provided.
Using the unit is not a substitute for consultation with
or treatment from a physician. Whenever you have
11
any pain or illness, always contact your physician first.
If you have health concerns of any kind, contact your
general practitioner!
When using the atomiser, always follow the basic
hygiene procedures.
Always follow your doctor’s instructions regarding
the type of medicine to be used and the dose, fre­quency, and duration of inhalation.
Only use medicines that have been prescribed or
recommended by your doctor or pharmacist.
If the unit does not function correctly or if you begin
to feel unwell or feel pain, stop using the unit im­mediately.
During use, hold the unit away from the eyes, as
some nebulised medicines may cause damage to the eyes.
Do not operate the unit in the presence of flammable
gases.
This device is not intended to be used by children
or persons with restricted physical, sensory (e.g. insensitivity to pain) or mental abilities or persons lacking in the required experience or knowledge for safe operation of the device, unless supervised or instructed by a person responsible for their safety.
Keep children away from packaging materials (risk
of suffocation).
Do not use attachments that are not recommended
by the manufacturer.
Connect the unit only to the mains voltage listed on
the type plate.
Do not dip the unit into water and do not use it in wet
rooms. Do not allow any liquid to penetrate the unit.
Protect the unit from strong impacts.
Never touch the mains cable with wet hands, this
can cause an electric shock.
Do not pull the mains plug from the socket by the
cord.
Do not pinch or bend the mains cable, pull it over
sharp objects, or allow it to hang freely, and protect it against sources of heat.
If the mains cable or housing is damaged, contact
our customer service department or your local deal­er.
Opening the unit carries a risk of electric shock. Dis-
connection from the mains supply is only guaranteed if the mains plug has been removed from the socket.
Do not use the unit if it has fallen or been dropped
on the floor, been exposed to extreme humidity or is otherwise damaged. In case of doubt, contact our customer service department or your local dealer.
The IH 25/1 nebuliser must only be used with suit-
able Beurer atomisers and with the appropriate Beurer accessories. The use of other atomisers and
accessories can impair therapeutic efficiency and may damage the device.
Important
Power cuts, sudden faults or other unfavourable
conditions may render the unit unusable. You are therefore recommended to keep a spare device or replacement medicine (as agreed with the doctor).
If adapters or extensions are required, these must
comply with the applicable safety regulations. The electrical capacity and the maximum capacity speci­fied on the adapter must not be exceeded.
The unit and the mains cable must be stored away
from sources of heat.
Do not use the unit in a room in which a spray has
previously been used. If this is the case, ventilate the room before commencing treatment.
Do not allow any objects to enter or obstruct the
ventilation openings.
Do not use the device if you notice an unusual noise.
For hygiene reasons, each user must use his own
accessories.
Always disconnect from the mains after use.
Store the device in a location protected against en-
vironmental influences. The device must be stored in the specified ambient conditions.
FUSE
The device contains an overload protection fuse.
This must only be changed by authorised specialist personnel.
The device also features a thermal fuse that switches
off the nebuliser in the event of overheating. Should this occur, proceed as follows: – Switch off the appliance. – Disconnect from the mains. – Wait for a minimum of 30 minutes until the device
has completely cooled down.
– Then switch the device on again, and observe
whether it makes any abnormal noises. If there are no unusual noises, you can use the device again. Otherwise, contact your customer service team.
General notes
Important
Use the unit only:
on humans,
for its intended purpose (aerosol inhalation) and in the manner described in these instructions for use.
Any improper use can be dangerous!
In acute emergencies, first aid takes priority.
Apart from the medication, use only distilled water or
a saline solution in the unit. Other liquids may cause defects to the nebuliser or atomiser.
12
This unit is not intended for commercial or clinical
use, but only for individual, private household use!
Before using the unit for the first time
Important
Before you use the unit for the first time, remove all
packaging materials.
Protect the unit against dust, dirt and moisture.
Never cover the unit during operation.
Do not use the unit in very dusty environments.
Switch the unit off immediately if it is defective or
malfunctioning.
The manufacturer shall not be held liable for damage
or injuries caused by improper or incorrect use.
Repairs
Note
Never open or attempt to repair the unit yourself, as
otherwise proper function is no longer guaranteed. Failure to observe this regulation shall void the war­ranty.
If you need to have the unit repaired, contact cus-
tomer service or an authorised dealer.
4. Description of device and accessories
Overview of the nebuliser
1 Carry handle 2 On/off switch (rear of device) 3 Mains cable 4 Hose connection 5 Filter cap with filter 6 Holder for atomiser
Overview of atomiser and accessories
7 Compressed air hose 8 Atomiser 9 Atomiser insert 10 Medicine container 11 Mouthpiece 12 Nosepiece 13 Adult mask 14 Child mask 15 Replacement filter 16 Storage bag
5. Initial use
Setup
Remove the unit from the packaging. Place it on a flat surface. Ensure that the ventilation slits are free.
Before using the unit for the first time
Note
The atomiser and accessories must be cleaned and
disinfected before they are used for the first time. For information about this, see “Cleaning and disinfec­tion” on page 14.
Attach the compressed-air hose [7] at the bottom of
the medicine container [10].
3
1
2
6
4
5
7
8
9
10
15
16
14
13
12
11
13
Connect the other end of the hose [7] to the hose
connector [4] on the nebuliser by lightly turning it.
Mains connection
Connect the unit only to the mains voltage listed on the type plate.
• Insert the mains cable plug [3] into a suitable socket.
Push the plug completely into the mains socket.
Note
Ensure that there is a socket near to where the unit
will stand.
Lay the mains cable in such a way that no one can
trip over it.
To disconnect the nebuliser from the mains after use,
first switch off the device and then remove the plug from the socket.
6. Operation
Caution
For hygiene reasons, the atomiser [8] and the ac-
cessories must be cleaned after each treatment and disinfected after the last treatment of the day.
If several different medicines are to be inhaled in suc-
cession during therapeutic use, the atomiser [8] must be rinsed under warm tap water after each use. For information about this, see “Cleaning and disinfec­tion” on page 14.
Follow the instructions for changing the filter con-
tained in these instructions.
Before each use, check that the hose connections
on the nebuliser [4] and the atomiser [8] are tight.
Before use, check that the device is functioning cor-
rectly. To do this, switch on the nebuliser (including the connected atomiser, but without any medication) for a short time. If the atomiser [8] expels air, the device is functioning correctly.
1. Filling the atomiser
Open the lid of the atomiser [8].
Fill with an isotonic saline solution
or pour the medication directly into the atomiser [8]. Do not overfill! The maximum recommended fill level is 8 ml !
• Use medication only on the advice of
a physician, and check the appropri­ate inhalation duration and quantity for your needs.
• If the required volume of medication is less than 2 ml,
top up this quantity to at least 4 ml using an isotonic saline solution. Viscous medicines may also require dilution. Always follow the instructions of your doctor.
2. Closing the atomiser
• Close the lid of the atomiser [8].
3. Connecting the accessories to the atomiser
• Connect the required accessory part (mouthpiece [11],
nosepiece [12], adult mask [13] or child mask [14]) to the atomiser [8].
• Before commencing treatment, pull the atomiser up-
wards out of its holder [6].
Start the nebuliser using the on/off switch [2].
A flow of spray from the atomiser indicates that the
device is functioning properly.
4. Treatment
Inhale the nebulised medicine deeply.
Note
During treatment, hold the atomiser straight (vertical), otherwise the atomisation does not work and correct function cannot be guaranteed.
Important
Essential oils, cough medicines, solutions designed for gargling, and drops for application to the skin or for use in steam baths are wholly unsuitable for inha­lation using a nebuliser. These substances are often highly viscous and can impair the correct function of the device and hence affect the effectiveness of its application in the long term. In the case of oversensitivity of the bronchial system, medicines containing essential oils can sometimes cause acute bronchiospasm (a sudden, cramp-like tightening of the bronchi accompanied by breathless­ness). Always ask your doctor or pharmacist for advice!
5. End of inhalation
If the spray is only output sporadically or if the noise changes during inhalation, you can end the treatment.
After treatment, turn off the nebuliser at the switch
[2] and disconnect it from the mains.
After use, replace the atomiser [8] in its holder [6].
14
6. Clean the device
For information about this, see “Cleaning and disinfec­tion” on page 14.
7. Changing the filter
Check the filter after every 10th use. If the filter is very contaminated or blocked, replace the used filter. If the filter has become wet, it must also be replaced with a new one.
Caution
Do not try to clean and re-use the used filter!
Only use original filters supplied by the manufacturer.
Otherwise, your nebuliser may become damaged or effective therapy can no longer be guaranteed.
Never operate the device without a filter.
To replace the filter, proceed as follows:
Caution
First switch off the unit and unplug it.
Allow the unit to cool down.
1. Turn the filter cap [5] an-
ti-clockwise and remove it towards the front.
Note
If the filter remains in the unit when the cap is removed, remove the filter from the unit using tweezers or similar.
2. Re-insert the filter cap [5] with a new filter. To do
this, insert the cap and turn clockwise until it is felt to engage.
3. Check that the filter cap is firmly in place.
8. Cleaning and disinfection
Atomiser and accessories
Warning
Observe the following hygiene instructions in order to avoid any health risks.
The atomiser [8] and accessories are intended for
multiple use. Please note that cleaning requirements differ according to the different application areas.
Notes:
The atomiser and accessories must not be me-
chanically cleaned with brushes or similar as this can cause irreparable damage and the success of the treatment can no longer be guaranteed.
For additional requirements regarding the necessary
hygienic preparations (hand washing, handling of medicines or inhalation solutions) in high-risk groups (e.g. cystic fibrosis patients), contact your doctor.
Ensure that all parts are properly dried following all
cleaning and disinfection. Residual moisture or water droplets can result in an increased risk of bacterial growth.
Preparation
Directly following each treatment, all parts of the
atomiser [8] and any accessories used must be cleaned of medicine residues and contamination.
To do this, dismantle the atomiser [8] into its indi-
vidual parts.
Remove the mouthpiece [11] from the atomiser.
Dismantle the atomiser by turning
the atomiser insert [9] anticlockwise against the medication container [10] and pull upwards.
The nebuliser is later reassembled in
the reverse order.
Cleaning
Important
Before you clean the unit, always switch it off, unplug it and let it cool off.
The atomiser and the used accessories such as mouthpiece, mask, etc. must be washed with hot wa­ter after each use.
Carefully dry all components using a soft cloth. Once all components are fully dry, reassemble the atomiser and place the components in a dry, sealed container or carry out disinfection.
When cleaning, ensure that all residues are removed. Never use any substances that may be poisonous when in contact with the skin or mucous membranes, or when swallowed or inhaled.
Clean the device using a damp cloth, to which you can apply a little detergent if necessary.
Do not use abrasive detergents and never immerse the unit in water.
Important
• Ensure that no water penetrates inside the unit!
• Do not put the device or accessories in a dishwasher.
• Do not touch the unit with wet hands while it is plugged
in; do not allow any water to be sprayed onto the unit. The unit must be operated only when it is completely dry.
• Do not spray any liquids into the ventilation slots. Any
liquid that penetrates into the unit can damage the electrical parts or other components of the nebuliser and impair the function of the device.
Condensation, care of the hose
Depending on the environmental conditions, con­densation may collect in the hose. To prevent against
1
2
15
bacterial growth and to ensure effective therapeutic use, this moisture must always be removed. To remove moisture from the hose, proceed as follows:
Remove the hose [7] from the atomiser [8].
Leave the hose plugged into the nebuliser [4].
Run the nebuliser until all the moisture has been dis-
placed by the flow of air.
In the event of significant contamination, replace the
hose.
Disinfection
Follow the steps listed below carefully in order to disin­fect your atomiser and the accessories. It is advisable to disinfect the individual components after the last time they are used each day at the latest.
First clean the atomiser and the accessories as de-
scribed under “Cleaning”.
The atomiser should be taken apart and placed to-
gether with the mouthpiece and nosepiece in boiling hot water for at least 10 minutes. Avoid the parts coming into contact with the hot base of the pot.
You can also disinfect the atomiser, the mouthpiece
and the nosepiece with a standard vaporizer. Ob­serve the manufacturer’s instructions for use for the vaporizer when doing this.
Note
The face masks and air hose must not be placed in hot water!
Carefully dry all components using a soft cloth.
We recommend disinfecting the masks using a retail
disinfectant.
Once all components are fully dry, reassemble the
atomiser and place the components in a dry, sealed container.
Note
Ensure that all parts are thoroughly dried during, and in particular after cleaning, otherwise there is an in­creased risk of bacterial growth.
Drying
Place the individual components on a dry, clean and
absorbent surface and allow to dry completely (for at least 4 hours).
Material resistance
• As with all plastic components, frequent use and
cleaning of the atomiser and the accessories can lead to a certain amount of wear. Over time, this can alter the aerosol properties and may eventually affect the efficiency of therapy. We therefore recommend that you replace the atomiser after no more than a year.
When choosing a cleaning or disinfecting agent, note
the following: Only use mild cleaning or disinfect-
ant agents in the quantities recommended by the manufacturer.
Storage
Do not store the nebuliser in a damp atmosphere
(e.g. in the bathroom) or transport it together with damp objects.
Store and transport the nebuliser away from direct
sunlight.
Storage
The device and all accessories, e.g. the nebuliser
and masks, can be stored together in the storage bag provided.
9. Disposal
In the interest of environmental protection, do not dis­pose of the device in household waste. Please dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Elec­tronic Equipment). If you have any queries, please contact the ap­propriate local authorities.
10. Troubleshooting
Problem/ Question
Possible Cause/Remedy
The atomiser produces little or no aerosol.
1. Too much or too little medicine in the atomiser. Minimum: 0.5 ml, Maximum: 8 ml.
2. Check that the nozzles are not blocked If necessary, clean the noz­zle (e.g. by rinsing). Use the atomiser again. CAUTION: Only poke implements through the fine holes from the underside of the nozzle.
3. The atomiser is not held in an upright position.
4. The medicine solution is unsuitable for nebulising (e.g. too thick). The medicine solution should be specified by the doctor.
Output is too low.
Hose kinked, filter blocked, too much inhalation solution.
Which medicines are suitable for inhalation?
Consult your doctor.
Essentially all medicines that are suit­able and approved for device-based inhalation can be inhaled.
Some inhala­tion solution remains in the atomiser.
This is normal and occurs for technical reasons. Stop inhalation if you hear a notable difference in the noise of the atomiser.
16
Problem/ Question
Possible Cause/Remedy
What special steps should be taken for babies and children?
1. In babies, the mask should cover the mouth and nose to guarantee effec­tive inhalation.
2. In children, the mask should also cover the mouth and nose. Nebulisa­tion next to a sleeping person is not suitable because insufficient medicine reaches the lungs.
Note: Children should only use the device with help and under supervision of an adult. Never leave a child alone with the nebuliser.
Inhalation with the mask takes longer.
This is for technical reasons. Less medi­cine is inhaled per breath through the mask holes than using the mouthpiece. The aerosol is mixed with ambient air through the holes in the mask.
Why do I need to replace the atomiser at regular inter­vals?
There are two reasons for this:
1. To guarantee a therapeutically ef­fective particle spectrum, the nozzle holes should not exceed a certain diameter. Due to the thermal and mechanical stresses, the plastic is subjected to a certain amount of wear. The atomiser [8] is particularly sensitive. This can also cause chang­es to the droplet composition of the aerosol, which has a direct effect on the effectiveness of the treatment.
2. You are also recommended to re­place the atomiser on a regular basis for hygiene reasons.
Does each per­son need their own atomiser?
This is absolutely necessary for hygiene reasons.
11. Technical specifications
Dimensions (WxHxD) 166 x 141 x 148 mm
Weight 1.4 kg Operating
pressure approx. 1.0 bar Atomiser fill
volume max. 8 ml Medicine flow approx. 0.22 ml/min. Sound pressure max. 60 dBA
(acc. to DIN EN 13544-1)
Mains connection
230 V ~, 50 Hz; 180 VA Housing material ABS / PP Operating
conditions
Temperature: +10 °C – +40 °C
Relative humidity: 10% – 90% Storage and
transport conditions
Temperature: -25 °C – +60 °C
Relative humidity: 10% – 90%
Atmospheric pressure: 500 – 1060 hPa
Subject to technical modifications.
All measurements were obtained with a sodium chlo­ride solution using a laser diffraction method. This diagram may not be applicable for suspensions or highly viscous medicines. More information can be obtained from the relevant medicine manufacturer.
Spare parts
Designation Material REF
Nebulisation stopper PP
162.819
Yearpack (contains Mouth­piece, Adult mask, Child mask, Atomiser, Compressed air hose, Filter, Nosepiece)
PP/ PVC 601.03
Note
If the unit is used outside of the specifications, proper function is no longer guaranteed! We reserve the right to make technical changes to im­prove and further develop the product. This device and its accessories comply with European standards EN60601-1 and EN60601-1-2, as well as EN13544-1, and is subject to special safety measures in terms of electromagnetic tolerance. Note that port­able and mobile RF communication equipment can affect this unit. More details can be requested from the stated Customer Service address or found at the end of the instructions for use. The unit conforms to the requirements of the European Directive for Medical Products 93/42/EC, the MPG (German Medical units Act).
ELECTROMAGNETIC COMPATIBILITY
The device complies with current specifications with
regard to electromagnetic compatibility and is suit­able for use in all premises, including those des­ignated for private residential purposes. The radio frequency emissions of the device are extremely low and in all probability do not cause any interference with other devices in the proximity.
It is recommended that you do not place the device
on top of or close to other devices. Should you notice any interference with other electrical devices, move the unit or connect it to a different socket.
Radio equipment may affect the operation of this
device.
100
50
0
0.20 1.00 10.00
Particle Diameter (μm)
Cumulative Volume (%)
50.00
17
FRANÇAIS
Eléments fournis
Voir la description de l’appareil et des accessoires page 19.
Inhalateur
Nébuliseur
Flexible à air comprimé
Embout buccal
Masque pour adulte
Masque pour enfant
Embout nasal
Filtre de rechange
Pochette de rangement
Notice d’utilisation
1. Apprendre à connaître
Cher cliente, cher client,
Nous vous remercions d’avoir choisi l’un de nos pro­duits. Notre société est réputée pour l’excellence de ses produits et les contrôles de qualité approfondis auxquels ils sont soumis, dans les domaines suivants : chaleur, contrôle du poids, diagnostic de pression arté­rielle, mesure de température du corps et du pouls, thérapies douces, massage et purification d’air. Lisez attentivement cette notice, conservez- la pour un usage ultérieur, mettez-la à la disposition des autres utilisateurs et suivez les consignes qui y figurent.
Sincères salutations, votre équipe Beurer
Domaine d’application
Cet inhalateur est un appareil servant à la nébulisation de liquides et de médicaments liquides (aérosols) et au traitement des voies respiratoires supérieures et inférieures.
La nébulisation et l’inhalation d’un médicament prescrit ou recommandé par le médecin permet de prévenir les
1. Apprendre à connaître .......................................17
2. Symboles utilisés ..............................................17
3. Consignes d’avertissement et de sécurité ........18
4. Description de l’appareil et des accessoires .....19
5. Mise en service ..................................................20
6. Utilisation ...........................................................20
7. Changement du filtre .........................................21
8. Nettoyage et désinfection .................................21
9. Mise au rebut .....................................................23
10. Dépannage ........................................................23
11. Caractéristiques techniques .............................. 24
Sommaire
maladies des voies respiratoires, de limiter leurs effets secondaires et d’accélérer la guérison. Consultez votre médecin ou pharmacien pour en savoir plus sur les possibilités d’utilisation.
L’appareil est conçu pour l’inhalation à domicile. L’in­halation de médicaments ne doit s’effectuer que sur avis médical. Soyez calme et détendu pour procéder à l’inhalation. Inspirez lentement et profondément afin que le médicament parvienne jusqu’aux bronches les plus fines et les plus lointaines. Expirez normalement.
Après préparation, l’appareil est approprié pour une réutilisation. La préparation comprend le remplacement de tous les accessoires, y compris du nébuliseur et du filtre à air, ainsi qu’une désinfection de la surface de l’appareil à l’aide d’un désinfectant d’usage dans le commerce.
2. Symboles utilisés
Voici les symboles utilisés dans la notice d’utilisation :
Avertissement Ce symbole vous avertit des
risques de blessures ou des dangers pour votre santé.
Attention Ce symbole vous avertit des
éventuels dommages au niveau de l’appareil ou d’un accessoire.
Remarque
Ce symbole indique des infor­mations importantes.
Voici les symboles utilisés sur l’emballage et sur la plaque signalétique de l’appareil et des accessoires :
Partie d’application, type BF
Lire la notice d’utilisation
Appareil de classe 2
F
abricant
I
Marche
O
Arrêt
SN
Numéro de série
IP 21
Protection contre les corps solides ≥12,5 mm et contre les chutes verticales de gouttes d‘eau
18
3. Consignes d’avertissement et de
sécurité
Avertissement
Avant l’utilisation, assurez-vous qu’aucun dommage
apparent n’est visible sur l’appareil et les acces­soires. En cas de doute, n’utilisez pas l’appareil et adressez-vous à votre revendeur ou à votre service aprèsvente.
• L’usage de l’appareil ne se substitue pas à une
consultation chez le médecin, ni à un traitement. Par conséquent, en cas de douleur ou de maladie de toute nature, consultez toujours d’abord votre médecin.
En cas de doutes de quelque nature que ce soit
concernant votre santé, consultez votre médecin traitant.
Respectez les mesures générales d’hygiène pour
l’utilisation du nébuliseur.
Conformez-vous aux indications du médecin pour ce
qui est du type de médicament à utiliser, du dosage, de la fréquence d’administration et de la durée de l’inhalation.
Utilisez uniquement les médicaments qui ont été
prescrits ou recommandés par votre médecin ou pharmacien.
En cas de fonctionnement erratique de l’appareil, de
malaise ou de douleurs, interrompez immédiatement le traitement.
Tenez l’appareil loin de vos yeux pendant l’utilisation
pour les protéger du nuage de médicament.
Ne faites pas fonctionner l’appareil en présence de
gaz inflammables.
• Cet appareil n’est pas conçu pour être utilisé par
des enfants ou des personnes dont les facultés phy­siques, sensorielles (par ex. insensibilité à la douleur) ou psychiques sont limitées ou manquant d’expé­rience et/ou des connaissances nécessaires. Elles peuvent toutefois s’en servir à condition de le faire sous la surveillance d’une personne responsable de leur sécurité ou de suivre les directives de cette der­nière.
Ne laissez pas l’emballage à la portée des enfants
(risque d’étouffement).
N’utilisez pas de pièces supplémentaires ou d’acces-
soires non recommandés par le fabricant.
L’appareil doit uniquement être raccordé à la tension
secteur indiquée sur la plaque signalétique.
N’immergez pas l’appareil sous l’eau et ne l’utilisez
pas dans des locaux humides. Aucun liquide ne doit pénétrer dans l’appareil.
Protégez l’appareil contre les chocs importants.
Ne touchez jamais le câble d’alimentation avec les
mains humides, vous risquez de recevoir une dé­charge électrique.
Ne débranchez pas la fiche secteur de la prise de
courant en tirant sur le câble.
Ne pincez pas le câble, ne le pliez pas, ne le tendez
pas sur des objets à arêtes vives, ne le laissez pas pendre et protégez- le de la chaleur.
En cas d’endommagements du câble d’alimentation
et du corps de l’appareil, adressez-vous au service après-vente ou à votre revendeur.
Un risque de choc électrique existe si vous ouvrez
le corps de l’appareil. La déconnexion du réseau d’alimentation n’est garantie que si la fiche secteur est débranchée de la prise de courant.
Si l’appareil est tombé, a été soumis à une humidité
importante ou garde des séquelles de sa chute, il ne doit plus être utilisé. En cas de doute, contactez votre service après-vente ou votre revendeur.
L’inhalateur IH 25/1 ne peut être utilisé qu’avec des
nébuliseurs Beurer et accessoires Beurer adaptés. L’utilisation de nébuliseurs et d’accessoires d’une autre marque peut nuire à l’efficacité du traitement et, dans certains cas, endommager l’appareil.
Attention
Une coupure de courant, des perturbations ou
d’autres conditions défavorables peuvent entraîner une indisponibilité de l’appareil. Il est par conséquent recommandé de disposer d’un appareil de remplace­ment ou d’un médicament (prescrit par le médecin).
Si des adaptateurs ou des rallonges sont néces-
saires, ils doivent satisfaire aux consignes de sécu­rité qui s’appliquent. La tension d’alimentation maxi­male et la puissance électrique maximale indiquée sur l’adaptateur ne doivent pas être dépassées.
L’appareil et le câble d’alimentation ne doivent pas
être conservés à proximité de sources de chaleur.
L’appareil ne doit pas être utilisé dans des pièces où
des aérosols ont été utilisés auparavant. Ces pièces doivent être aérées avant de procéder au traitement.
Aucun objet ne doit venir obstruer les ouvertures
d’aération.
• N’utilisez jamais l’appareil s’il émet un bruit anormal.
Pour des raisons hygiéniques, il est indispensable
que chaque utilisateur utilise ses propres acces­soires.
Retirez systématiquement la fiche secteur après
avoir utilisé l’appareil.
Conservez l’appareil dans un endroit à l’abri des
aléas météorologiques. Les conditions atmosphé­riques préconisées pour son stockage doivent être respectées.
DISPOSITIF DE SECURITE
Une protection de surintensité est intégrée dans
l’appareil. Celle-ci ne peut être remplacée que par un personnel qualifié et autorisé.
19
• L’appareil dispose en outre d’une protection ther-
mique qui désactive l’inhalateur en cas de surtempé­rature. En pareil cas, veuillez procéder comme suit : – Arrêtez l’appareil. – Débranchez la fiche secteur. –
Attendez au moins 30 minutes, jusqu’à ce que l’ap­pareil soit entièrement refroidi.
Remettez ensuite l’appareil en marche et faites atten­tion aux bruits anormaux. En l’absence de bruits anor­maux vous pouvez réutiliser l’appareil, sinon veuillez vous adresser au service aprèsvente indiqué.
Remarques générales
Attention
L’appareil doit être uniquement utilisé :
– sur l’homme, – pour l’usage auquel il est destiné (inhalation d’aéro-
sols) et selon la méthode décrite dans cette notice d’utilisation.
Toute utilisation inappropriée peut s’avérer dan-
gereuse !
En cas de situation d’urgence, effectuez les gestes
de premiers secours.
Outre les médicaments, utilisez uniquement de l’eau
distillée ou une solution de chlorure de sodium. D’autres liquides peuvent endommager dans cer­tains cas l’inhalateur ou le nébuliseur.
Cet appareil n’est pas destiné à un usage profes-
sionnel ou clinique, il est réservé exclusivement à un usage domestique.
Avant la mise en service
Attention
Avant d’utiliser l’appareil, retirez tous les matériaux
d’emballage.
Protégez l’appareil de la poussière, de la saleté et
de l’humidité, ne couvrez en aucun cas l’appareil lorsqu’il fonctionne.
N’utilisez pas l’appareil dans un environnement trop
poussiéreux.
Eteignez immédiatement l’appareil en cas de défauts
ou de dysfonctionnements.
Le fabricant décline toute responsabilité quant aux
dommages résultant d’une utilisation inappropriée ou incorrecte de l’appareil.
Réparation
Remarque
• Vous ne devez en aucun cas ouvrir ou réparer l’appa-
reil, faute de quoi le fonctionnement de l’appareil ne serait plus garanti. En cas de non-respect de ce point, la garantie est annulée.
Pour toute réparation, adressez-vous au service
après-vente ou à un revendeur agréé.
4. Description de l’appareil et des accessoires
Aperçu de l’inhalateur
1 Poignée de transport 2 Interrupteur de marche/arrêt (à l’arrière) 3 Cordon d’alimentation secteur 4 Raccord du flexible 5 Bouchon-filtre avec filtre 6 Support du nébuliseur
Aperçu du nébuliseur et des accessoires
7 Flexible à air comprimé 8 Nébuliseur 9 Système de nébuli-
sation
10 Récipient à médica-
ments
11 Embout buccal 12 Embout nasal 13 Masque pour adulte 14 Masque pour enfant 15 Filtre de rechange 16 Pochette de rangement
3
1
2
6
4
5
7
8
9
10
15
16
14
13
12
11
20
5. Mise en service
Installation
Retirez l’appareil de l’emballage. Placez-le sur une surface plane. Veillez à bien dégager les ouvertures d’aération.
Avant la première utilisation
Remarque
Le nébuliseur et les accessoires devraient être net-
toyés et désinfectés avant leur première utilisation. Voir à cet égard le chapitre « Nettoyage et désinfec­tion », page 21.
Branchez le flexible à air comprimé [7] en bas sur le
récipient à médicaments [10].
Enfichez l’autre extrémité du flexible [7] dans le rac-
cord de flexible [4] de l’inhalateur, en le tournant légè­rement.
Raccordement au secteur
L’appareil doit uniquement être raccordé à la tension secteur indiquée sur la plaque signalétique.
Branchez la fiche du câble d’alimentation [3] dans
une prise adéquate.
Pour le raccordement au secteur, enfoncez la fiche
complètement dans la prise de courant.
Remarque
Veillez à ce qu’une prise de courant se trouve à proxi-
mité de l’emplacement de l’appareil.
Disposez le câble d’alimentation de telle sorte que
personne ne puisse trébucher.
Avant de débrancher l’inhalateur du réseau élec-
trique après le processus d’inhalation, éteignez tout d’abord l’appareil, puis débranchez la fiche secteur de la prise de courant.
6. Utilisation
Attention
Pour des raisons hygiéniques, il est indispensable de
nettoyer le nébuliseur [8] ainsi que les accessoires après chaque traitement, et de les désinfecter après le dernier traitement quotidien.
Si plusieurs médicaments différents devaient être
inhalés successivement lors d’une thérapie, le nébu­liseur [8] doit être rincé à l’eau de robinet chaude après chaque application. Voir à cet égard le chapitre « Nettoyage et désinfection », page 21.
Respectez les instructions de cette notice relatives
au changement du filtre !
Contrôlez avant chaque utilisation de l’appareil la
bonne fixation des raccords du flexible sur l’inhala­teur [4] et sur le nébuliseur [8].
Contrôlez le fonctionnement correct de l’appareil
avant de l’utiliser ; pour ce faire, mettez brièvement l’inhalateur en marche (avec le nébuliseur raccordé mais sans médicaments). L’appareil fonctionne cor­rectement si, à cette occasion, de l’air sort du nébu­liseur [8].
1. Remplissage du nébuliseur
Ouvrez le couvercle du nébuli-
seur [8].
Versez une solution saline isoto-
nique ou le médicament directe­ment dans le nébuliseur [8]. Atten­tion à ne pas trop le remplir ! La quantité maximale de remplissage recommandée est de 8 ml !
Utilisez uniquement des médica-
ments prescrits par votre médecin et demandez la durée et la dose d’inhalation adaptées à vos be­soins !
Si la dose de médicament prescrite est inférieure à
2 ml, remplissez cette quantité avec une solution de chlorure de sodium isotonique jusqu’à un minimum de 4 ml. La dilution est également nécessaire pour les médicaments visqueux. Conformez-vous aux indications de votre médecin.
21
2. Fermeture du nébuliseur
Fermez le couvercle du nébuliseur [8].
3.
Raccordement des accessoires au nébuliseur
Relier le nébuliseur [8] à l’accessoire souhaité (em-
bout buccal [11], embout nasal [12], masque pour adulte [13] ou masque pour enfant [14]).
Retirez le nébuliseur de son support [6] en le tirant
vers le haut avant de commencer le traitement.
Démarrez l’inhalateur au moyen de l’interrupteur
marche/arrêt [2].
Le brouillard de pulvérisation qui s’échappe du nébu-
liseur indique que l’appareil fonctionne parfaitement.
4. Traitement
Inspirez profondément le médicament nébulisé.
Remarque
Tenez le nébuliseur droit (vertical) pendant l’inhalation ; autrement, la nébulisation ne fonctionne pas et l’appa­reil ne peut plus fonctionner correctement.
Attention
Les huiles essentielles à base de plantes médicinales, les sirops contre la toux, les gargarismes, les gouttes pour frictions ou pour bains de vapeur sont impropres à l’inhalation avec des inhalateurs. Ces produits ajou­tés sont bien souvent visqueux et peuvent entraver le fonctionnement de l’appareil et ainsi l’efficacité du traitement. En cas d’hypersensibilité des bronches, les médicaments contenant des huiles essentielles peuvent dans certains cas entraîner un bronchos­pasme aigu (diminution du calibre des bronches par constriction pulmonaire avec respiration difficile). Demandez conseil à votre médecin ou pharmacien !
5. Fin de l’inhalation
Si le nuage de pulvérisation ne s’échappe plus que de façon irrégulière ou si le bruit change au cours de l’inhalation, vous pouvez arrêter l’inhalation.
Eteignez l’inhalateur après le traitement au moyen de
l’interrupteur [2] et débranchez- le du réseau élec­trique.
Après le traitement, remettez le nébuliseur [8] dans
son support [6].
6. Nettoyez l’appareil
Voir « Nettoyage et désinfection », page 21.
7. Changement du filtre
Contrôlez le filtre les 10 utilisations. S’il est fortement encrassé ou bouché, remplacez-le. Si le filtre est hu­mide, il doit également être remplacé par un filtre neuf.
Attention
N’essayez pas de nettoyer et de réutiliser le filtre
usagé !
Utilisez exclusivement le filtre d’origine du fabricant,
votre inhalateur risquant autrement d’être endom­magé ou le traitement de ne pas être assez efficace.
N’utilisez en aucun cas l’appareil sans filtre.
Procédez comme suit pour changer le filtre :
Attention
Eteignez tout d’abord l’appareil, puis débranchez-le
du secteur.
Laissez refroidir l’appareil.
1. Tournez le capuchon du
filtre [5] dans le sens inverse des aiguilles d’une montre puis tirez-le vers l’avant.
Remarque
Si le filtre reste dans l’appareil après le retrait du bou­chon-filtre, retirez-le, par exemple avec une pince ou un objet similaire.
2. Réinsérez le capuchon du filtre [5] doté du nouveau
filtre. Pour ce faire, insérez le capuchon et tournez-le dans le sens des aiguilles d’une montre jusqu’à ce que vous sentiez qu’il est enclenché.
3. Vérifiez qu’il est bien mis.
8. Nettoyage et désinfection
Nébuliseur et accessoires
Avertissement
Respectez les prescriptions suivantes en matière d’hygiène, afin d’éviter tout risque pour votre santé.
Le nébuliseur [8] et les accessoires sont destinés à
un usage multiple. Différentes exigences en matière de nettoyage et de préparation hygiénique existent pour les différents domaines d’application.
Remarques :
Le nébuliseur ainsi que les accessoires ne doivent
pas faire l’objet d’un nettoyage mécanique avec des brosses ou autres objets similaires, étant donné qu’à cette occasion il pourrait en résulter des dommages irréparables et que par conséquent le succès du trai­tement n’est plus garanti.
Demandez conseil à votre médecin pour connaître
les exigences supplémentaires en matière de prépa­ration hygiénique requise (manucure, manipulation des médicaments ou des solutions à inhaler) pour les groupes à risques (par exemple patients atteints de mucoviscidose).