![](/html/fd/fd0f/fd0f58a8dccb858f52536b8e519208775b32144f370fa97a90ff9f5f73d15a32/bg1.png)
Model FMS10
Model FMS20
ML-141018
ML-141040
ML-141057
ML-134327
OWNER/OPERATOR
MANUAL
Berkel Company
PO Box 696
2006 Northwestern Parkway
Louisville, Kentucky 40201
1-800-348-0251
Fax 888-888-2838
F37271 Rev. A (February 2011)
![](/html/fd/fd0f/fd0f58a8dccb858f52536b8e519208775b32144f370fa97a90ff9f5f73d15a32/bg2.png)
TABLE OF CONTENTS
GENERAL.........................................................................................................................3
INSTALLATION.................................................................................................................3
Unpacking...................................................................................................................3
Location......................................................................................................................3
Electrical Connections................................................................................................3
OPERATION.....................................................................................................................4
Controls.........................................................................................................................5
Non-Timed Mixing....................................................................................................... 5
MIXING.............................................................................................................................6
Bowl............................................................................................................................6
Agitator........................................................................................................................6
Wire Cage...................................................................................................................7
Remove Wire Cage/Bowl Guard.................................................................................7
Install Wire Cage/Bowl Guar.......................................................................................7
CLEANING........................................................................................................................7
MIXING BOWL CAPACITY CHART.................................................................................8
Agitators and Accessories...........................................................................................9
MAINTENANCE................................................................................................................9
Motor...........................................................................................................................9
Bowl Lift Slideways.....................................................................................................9
SERVICE.........................................................................................................................10
WARRANTY....................................................................................................................11
NOTES............................................................................................................................12
FMS10 & FMS20 Owner/Operator Manual
– 2 –
© Berkel, 2010
![](/html/fd/fd0f/fd0f58a8dccb858f52536b8e519208775b32144f370fa97a90ff9f5f73d15a32/bg3.png)
Installation, Operation, and Care of
BERKEL FMS10 & 20 Quart MIXER
SAVE THESE INSTRUCTIONS
GENERAL
The 10 quart mixer has a DC electric motor and motor control. A 10 quart bowl, bowl guard, B-Flat beater,
spiral dough hook, D wire whip and ingredient chute are shipped as standard equipment. A 0-15 minute
timer and four plastic foot pads are standard.
The 20 quart mixer has a DC electric motor and motor control. A 20 quart bowl, bowl guard, B-fl at beater,
spiral dough hook, D wire whip and ingredient chute are ship ped as sta ndar d equi p ment . A 0 - 15 m inute
timer and four plastic foot pads are standard. A #12 attachment hub is standard. A variety of attachments
are available. A 10 quart bowl and its associated accessories are optional.
INSTALLATION
UNPACKING
Immediately after unpacking the mixer, check for possible shipping damage. If the mixer is found to be
damaged, save the packaging material and contact the carrier within 15 days of delivery.
Prior to installation, test the electrical service to assure that it agrees with the specifi cations on the machine
data plate.
LOCATION
Remove hex head shipping bolts with a 3/8" wrench (or crescent wrench), that attaches the four legs to
the base-frame of the carton.
Place the mixer on a suitable sturdy level surface. There should be adequate space around the mixer for
the user to operate the controls and install and remove bowls.
ELECTRICAL CONNECTIONS (Cord Connected Mixers)
The electrical cord on this machine is equipped with a three-pronged grounding
plug which must be connected to a properly grounded receptacle. If the receptacle is not the
proper grounding type, contact an electrician. Do not remove the grounding prong from the
plug.
FMS10 & FMS20 Owner/Operator Manual
– 3 –
![](/html/fd/fd0f/fd0f58a8dccb858f52536b8e519208775b32144f370fa97a90ff9f5f73d15a32/bg4.png)
Moving beater in bowl. Keep hands, clothing, and utensils out while in operation.
Do not use without interlocked guard.
Bowl Guard
Wire Cage
Agitator
OPERATION
Controls
Bowl Guard
Splash Guard
Bowl Lift
Handle
Fig. 1
Bowl
Support
Attachment Hub
Thumb Screw
and Plug
Fig. 1A (20 Quart Mixer)
FMS10 & FMS20 Owner/Operator Manual
– 4 –