Berkel FMS10, ML-141040, ML-141018, ML-134327, ML-141057 User Manual

...
Model FMS10 Model FMS20
OWNER/OPERATOR MANUAL
Berkel Company PO Box 696 2006 Northwestern Parkway Louisville, Kentucky 40201 1-800-348-0251 Fax 888-888-2838
F37271 Rev. A (February 2011)
TABLE OF CONTENTS
GENERAL.........................................................................................................................3
INSTALLATION.................................................................................................................3
Unpacking...................................................................................................................3
Location......................................................................................................................3
Electrical Connections................................................................................................3
OPERATION.....................................................................................................................4
Controls.........................................................................................................................5
Non-Timed Mixing....................................................................................................... 5
MIXING.............................................................................................................................6
Bowl............................................................................................................................6
Agitator........................................................................................................................6
Wire Cage...................................................................................................................7
Remove Wire Cage/Bowl Guard.................................................................................7
Install Wire Cage/Bowl Guar.......................................................................................7
CLEANING........................................................................................................................7
MIXING BOWL CAPACITY CHART.................................................................................8
Agitators and Accessories...........................................................................................9
MAINTENANCE................................................................................................................9
Motor...........................................................................................................................9
Bowl Lift Slideways.....................................................................................................9
SERVICE.........................................................................................................................10
WARRANTY....................................................................................................................11
NOTES............................................................................................................................12
FMS10 & FMS20 Owner/Operator Manual
– 2 –
© Berkel, 2010
Installation, Operation, and Care of
BERKEL FMS10 & 20 Quart MIXER
SAVE THESE INSTRUCTIONS

GENERAL

The 10 quart mixer has a DC electric motor and motor control. A 10 quart bowl, bowl guard, B-Flat beater, spiral dough hook, D wire whip and ingredient chute are shipped as standard equipment. A 0-15 minute timer and four plastic foot pads are standard.
The 20 quart mixer has a DC electric motor and motor control. A 20 quart bowl, bowl guard, B-fl at beater, spiral dough hook, D wire whip and ingredient chute are ship ped as sta ndar d equi p ment . A 0 - 15 m inute timer and four plastic foot pads are standard. A #12 attachment hub is standard. A variety of attachments are available. A 10 quart bowl and its associated accessories are optional.

INSTALLATION

UNPACKING
Immediately after unpacking the mixer, check for possible shipping damage. If the mixer is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
Prior to installation, test the electrical service to assure that it agrees with the specifi cations on the machine data plate.
LOCATION
Remove hex head shipping bolts with a 3/8" wrench (or crescent wrench), that attaches the four legs to the base-frame of the carton.
Place the mixer on a suitable sturdy level surface. There should be adequate space around the mixer for the user to operate the controls and install and remove bowls.
ELECTRICAL CONNECTIONS (Cord Connected Mixers)
The electrical cord on this machine is equipped with a three-pronged grounding plug which must be connected to a properly grounded receptacle. If the receptacle is not the proper grounding type, contact an electrician. Do not remove the grounding prong from the plug.
FMS10 & FMS20 Owner/Operator Manual
– 3 –
Moving beater in bowl. Keep hands, clothing, and utensils out while in operation. Do not use without interlocked guard.
Bowl Guard Wire Cage
Agitator

OPERATION

Controls
Bowl Guard Splash Guard
Bowl Lift Handle
Fig. 1
Bowl Support
Attachment Hub Thumb Screw and Plug