Belmont 037, 039 User guide

Page 1
037/039
DENTAL CHAIR
INSTALLATION
and OPERATION INSTRUCTIONS
3.E
Page 2
TABLE OF CONTENTS
Overall View and Major Components..................................................................... 1
Dimensions and Specifications................................................................................ 2
Dimensions and Specifications (Europe Type) ..................................................... 2A
Installation Procedures ............................................................................................ 3
Operation Procedures .............................................................................................. 4
Adjustment of Auto Positioning ............................................................................. 6B
Care and Maintenance ............................................................................................ 6B
Page 3
1. 037/039 OVERALL VIEW AND MAJOR COMPONENTS
1
2
1'
7 8
2
3
3
4
5
6
13
4
7
12
11
9
10
5
8
037 CHAIR
6
12
11
10
9
039 CHAIR
(1) ARTICULATING HEADREST (7) ARMREST BLOCK (1') POWER HEADREST (8) CHAIR PRESET PANEL (2) BACKREST (9) BELLOWS (3) ARMREST (10)BASE PLATE (4) SEAT (11)ROTATION LOCK PEDAL (5) LEGREST (12)FOOT SWITCH (CHAIR) (6) RETRACTABLE FOOTREST (13)FOOT SWITCH (HEADREST)
Fig. 1-1 OVERALL VIEW
1
Page 4
2. DIMENSIONS AND SPECIFICATIONS
600 500
210(037) 220(039)
3°
95
°
10°
20°
30°
520
675
450 500
575
1650(037) 1630(039)
1120(037)
395
475(037) 455(039)
560 615
385
CHAIR WEIGHT 150 kg (037)
154 kg (039)
INITIAL HEIGHT 455 mm
1100(039)
15
90°
220
500
455
SEAT ELEVATION STROKE 260 mm HEADREST EXTENSION 120 mm (039) LEGREST EXTENSION 230 mm BASE DIMENSION 555 mm x 570 mm x 15 mm HYDRAULIC FLUID 900 cc
(10W NON-DETERGENT HYDRAULIC OIL) TYPE OF MOTOR PUMP 5 LP POWER CONSUMPTION 600/500W at 50/60Hz RANGE OF HEADREST ANGLE 64 dig. (037)
38 dig. (039)
2
Page 5
DIMENSIONS AND SPECIFICATIONS (EUROPE TYPE)
600 500
210(037) 220(039)
95
°
3°
°
10°
20
°
30
557
712
450 500
575
1650(037) 1630(039)
1157(037)
432
475(037) 455(039)
560 615
422
CHAIR WEIGHT 150 kg (037)
154 kg (039)
INITIAL HEIGHT 487 mm
1137(039)
15
90°
220
500
487
SEAT ELEVATION STROKE 300 mm HEADREST EXTENSION 120 mm (039) LEGREST EXTENSION 230 mm BASE DIMENSION 555 mm x 570 mm x 15 mm HYDRAULIC FLUID 900 cc
(10W NON-DETERGENT HYDRAULIC OIL) TYPE OF MOTOR PUMP 5 LP POWER CONSUMPTION 600/500W at 50/60Hz RANGE OF HEADREST ANGLE 64 dig. (037)
38 dig. (039)
039 : After Ser. No. DDA080219 037 : From 1997 October Production
2A
Page 6
3. INSTALLATION PROCEDURES
1) Place chair crate just behind the planned location for the chair.
2) Open the crate and remove all packing materials.
(Do not use sharp instrument that can damage upholstery.) Slide the chair off palette into the place. DO NOT LIFT THE CHAIR BY ARMRESTS OR BACKREST.
3) Once the chair is located, but BEFORE PLUGGING INTO POWER, do the followings ;
(1) Remove red bolt with a caution tag located on chair seat-plate. (2) Grasping red tag on bellows, pull out rubber plug of oil reservoir. (3) Save above red bolt and rubber plug in case the chair is ever reshipped in the future.
4) Remove 3 nuts and washers under the seat.
Attach the seat on seat-plate and fix it by screwing the nuts and washers from underneath the seat-plate.
5) Attach bellows to bellows support.
(1) Loosen and remove 4 Phillips screws on bellows support-rear, then remove the bellows support-rear from the chair. (2) Hang the top plate of bellows on the edge of bellows support-front, and hang the top-rear plate of bellows on the edge of bellows support-rear. (3) Reattach bellows support-rear with hanging bellows on to the chair by screwing 4 Phillips screws.
6) Unpack the small carton containing accessories. Check following items in it.
Headrest Assembly (037) .............................. 1 pce.
Foot Switch (039).......................................... 1 pce.
Flat Head Wood Screw (Pie.4.8 - 40) ............4 pcs.
Anchor Plug (7 x 30) ......................................4 pcs.
For an 037 chair, slide headrest into slide mount on top of backrest.
7) Plug the chair into an appropriate electric power source.
8) Turn on the Main Switch located on left side of Pump Cover. (See Fig. 2-1.)
1
MAIN SWITCH
2
FUSE (6.3 A)
3
POWER CORD
3
Fig. 2-1 Main Switch Panel
21
AFTER INSTALLATION
Once the chair is installed according to above steps, check the all chair functions following the operation procedures in this booklet.
3
Page 7
4. OPERATION PROCEDURES
The Belmont 037/039 chair was designed for maximum simplicity of operation. However,taking a few moments to familiarise yourself with the operation of the chair will make it's operation comfortable and simple for you and your patients.
Basic Control Function: Chair manual control functions are duplicated on both sides of the pump cover. Chair auto control functions are equipped on rear side of the pump cover. A separate foot control is used with the power headrest (039).
1) Chair Manual Controls (See Fig. 3-l.)
(1) Seat Height Control To raise : Move either side mounted foot switch up. To lower : Move either side mounted foot switch down. (2) Backrest Control To raise : Move either side mounted switch right. To reclining : Move either side mounted switch left.
2) Chair Auto-mode Controls (See Fig. 3-l.)
(1)Preset Mode Controls 037/039 chair has two preset positions and last position memory. To place the chair in each position with footrest extension. Momentarily move the foot switch located on rear side of the pump cover. Preset 1 : Move rear mounted switch left. Preset 2 : Move rear mounted switch right. LP : Move rear mounted switch up.
(2)Auto-return Control
To return the chair to the patient entry position (fully lowered with the footrest retracted), momentarily move rear mounted foot switch down.
3) Power Headrest Controls (039) (See Fig. 3-1.)
(1)To extend : Press down upper area of foot control disc. To retract : Press down lower area of foot control disc.
(2)To move back : Press down right side of foot control disc. To move forward : Press down left side of foot control disc.
4) Articulating twin axis prosthetic headrest adjustments (037) (See Fig. 3-2.)
Articulating twin axis prosthetic headrest adjusts to match patient's anatomy, looks securely in any desired position. To extend : Simply pull up to desired position. To retract : Depress to desired position.
5) Safety Stop
Automatic travel in all automatic mode can be instantly cancelled at any time by momentarily pressing any control switch.
6) Armrest Rotation (See Fig. 3-3.)
Either armrest can be rotated outward by pulling.
7) Chair Rotation (See Fig.3-l.)
Release rotation lock by pressing "N" footpad and lock chair in desired position by pressing "L" footpad.
4
Page 8
RAISE CHAIR
ROTATION LOCK PEDAL
CHAIR FUNCTIONS
RECLINE
BACKREST
PRESET
1
LOWER CHAIR
L P
AUTO-RETURN
Fig. 3-1 Control Switch Location & Function
RAISE
BACKREST
PRESET / AUTO-RETURN
PRESET
2
HEADREST FORWAD
LOCK
NEUTRAL
CHAIR BASE
EXTEND HEADREST
HEADREST BACK RETRACT
HEADREST
HEADREST FOOTSWITCH (039 ONLY)
Fig. 3-2 Headrest Adjustment
Fig. 3-3 Armrest Rotation
5
Page 9
8) Preset Position Adjustment (Fig.4-1)
Two Preset positions can be programmed.
Procedure 1.
1. Set seat and backrest in the desired position by manual control switches.
POWER LOCK OFF
2. Keep depressing STORE button on chair preset
panel until buzzer sounds Pi-,Pi-,Pi-.
3. While buzzer is sounding, press (1) button on
STORE
MODE
doctor table or assistant side control panel so that
the position is memorized to PRESET 1, then the buzzer sound ceases.
4. PRESET 2 is memorized by pressing (
22
2) button as following 1 to 3.
22
Fig.4-1 Chair Preset Panel
Procedure 2.
1. Set seat and backrest in the desired position by manual control switches.
2. Keep depressing (1) button on doctor table or assistant side control panel until buzzer sounds
so that the position is memorized to PRESET 1, then the buzzer sound ceases.
3. PRESET 2 is memorized by pressing (
22
2) button as following 1 to 2.
22
9) Mouth Rinsing Backrest Position Adjustment (Fig.4-1) The desired mouth rinsing backrest position can be programmed as last position memory operation. Procedure 1.
1. Set backrest in the desired position for mouth rinsing by manual control switch.
2. Keep depressing STORE button on chair preset panel until buzzer sounds Pi-,Pi-,Pi-.
3.While buzzer is sounding, press (LP) button on doctor table or assistant side control panel so that the position is memorized to mouth rinsing position then the buzzer sound ceases. Procedure 2.
1. Set backrest in the desired position by manual control switches.
2. Keep depressing (LP) button on doctor table or assistant side control panel until buzzer sounds
so that the position is memorized to mouth rinsing position, then the buzzer sound ceases.
Note ; When chair electric power is ON, the POWER L.E.D. illuminates in green. When chair safety lock system is not working, the LOCK OFF L.E.D. illuminates in green. When the LOCK OFF L.E.D. is OFF, chair can not be operated at all.
5. CARE AND MAINTENANCE
Other than cleaning, no scheduled maintenance of the chair is required.
Painted metal parts and vinyl upholstery should be cleaned with a mild detergent followed by disinfecting with alcohol.
The area around control switches can be cleaned with the same agent, however be sure to use only a moistened cloth to avoid getting contaminants into switch mechanism. NOTE: For safety reasons, the switch on this chair operate at low voltage.
6B
Page 10
Memo
TAKARA BELMONT CORPORATION
1-1, Higashi-shinsaibashi 2-Chome,Chuo-ku,Osaka 542-0083,Japan TEL. : 0081(6) 6213-5945 TELEFAX : 0081(6) 6212-3680
Printed in Japan 3.E 0506.MA