Beijing A3918 Owner's Manual

Wireless Thermostat Owners Manual
ModelA3918
FEATURES
Structure of thermostat and explanation for the keypads
We are pleased you have selected one of our broad line of wall thermostat. Our products are manufactured to high quality standards and are designed for years of service. REMOVE THE MYLAR LABEL FORM THE LCD DISPLAY WINDOW.
ARMCHAIR PROGRAMMING
1You can program your thermostat before installation following the instructions starting configuration menu. This can be done while you relax in your favorite chair an d is a very good way to familiarize yourself with all the functions of your thermostat. The following time and temperature settings are pre-programmed into the thermostat:
Temperature in ˚F (˚C) Program Number Time Heat Cool
1 6:00 am 68˚F(20˚C) 78˚F(26˚C) 2 8:00 am 60˚F(16˚C) 85˚F(29˚C) 3 4:00 pm 68˚F(20˚C) 78˚F(26˚C) 4 10:00 pm 60˚F(16˚C) 82˚F(28˚C)
COMPRESSOR PROTECTION
2The thermostat provides a 4 minutes delay after shutting of the heating or cooling system before it can be restarted. This feature will prevent damage to your compressor caused by rapid cycling. Note that this delay also applies to the heating system control. It does not provide a delay when there are power outages. you can select the function on or off at the configuration.
TEMPERATURE RANGE
3, This thermostat can be programmed between 45˚F and 95˚F (7˚C and 35˚C). However, it will display room temperatures from 30˚F to 99˚F (0˚C and 37˚C). “HI” will be displayed if the temperature is higher than 99˚F (37˚C), and “LO” will be displayed if the temperature is lower than 30˚F (0˚C).This thermostat will automatically cutoff in Heat mode if the temperature rises above 95˚F (35˚C), and automatically cutoff in Cool mode if the temperature drops below 45˚F (7˚C).
POWER SUPPLY
8The thermostat supply with Li-battery. You can charge the Lithium battery through USB connect to PC.during the charge process.the battery icon will flash one by one.
Note: Lithium battery should be charged over 12 hours at the first 3 times to ensure the battery capability.
INSTALLATION
What You Need This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your thermostat, you should have the following tools and materials.
Slotted Screwdriver(s) ■ Small Philips screwdriver ■ Hammer
Electric drill and 3/16” bit
OPERATION
Fan Operation
If your system does not have a G terminal connection, skip to Heating System System.
1. Turn on power to system.
2. Press FAN key to ON mode. The blower should begin to operate.
3. Move FAN key to AUTO mode. The blower should stop immediately
Heating System
1. Press system key until HEAT show LCD display. If the auxiliary heating system has a standing pilot, be sure to light it.
2. Press to adjust thermostat setting to 1 above room temperature. The heating system should begin to operate. The display should show “STG1”. However, if the setpoint temperature display is flashing, the compressor lockout feature is ope rating (see Configuration menu, item 5).
3. Adjust temperature setting to 3 above room temperature. If your system configuration is set at MS2, HP2 or HP1, the auxiliary heat system should begin to operate and the display should show “STG1+2” 2”.
4. Press to adjust the thermostat below room temperature. The heating system should stop operating.
Emergency System
EMER bypasses the Heat Pump to use the heat source wired to terminal E on the thermostat. EMER is typically used when compressor operation is not desired, or you prefer back-up heat only.
1. Press SYSTEM key to select Heat mode. then press EMER key.. “EMER” will show on the display.
2. Press to adjust thermostat setting above room temperature. The Aux. heating system will begin to operate. The display will show “STG1” “EMER” to indicate that the Aux. system is operating.
3. Adjust temperat ure setting to 2°C above room t emperature. The auxiliary hea t system should begin to operate and the display should show “STG1+2”.
4. Press to adjust the thermostat below room temperature. The Aux. heating system should stop operating.
Cooling System
1. Press SYSTEM key to select the Cool mode.
2. Press to adjust thermostat setting below room temperature. The blower should come on immediately on high speed, followed by cold air circulation. The display sho uld show “STG1”.
3. Adjust temperature setting to 2°C below room temperature. The second stage cooling should begin to operate and the display should show “STG1+2”
4. Press to adjust the temperature setting above room temperature. The cooling system should stop operating.
CONFIGURATION MENU
INSTALLER/CONFIGURATION MENU
Ste
p
Press
Button
Displayed
(Factory Default)
Press up or
down key
to select
Comments
1 PROG SS1 SS1, HP2,
HP1
Selects Single stage, Multi-stage,
or Heat Pump (Single stage or 2-stage) System Configuration
2 PROG (FAN)HE HG Select GAS/ ELECTRIC
(Only can select by STD2 or SS1)
3 PROG RECO(OF) ON Recovery function ON or OFF 4 PROG (SPAN)2 1,3 Span(one stage) 5 PROG BLIT(ON) OF BackLight 6 PROG (SP2)2 1,3 Span(Two Stage) 7 PROG (TEMP)F C Selects temperature display ° F
or °C
8 PROG HOUR(12) 24 Selects time format display
12hours or 24hours
9 PROG COHP(OF) ON Selects Compressor Lockout
OFF or ON 10 PROG CANL(1) 1-10 Communication channels 11 PROG FACT(0) 1 Select 1,all the setting will go
back to factory default The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements. Set SYSTEM mode to OFF, then simultaneously press PROG keys to enter configuration menu. The display will show the first item in the configuration menu. The configuration menu table summarizes the configuration opti ons. An explanation of each option follows .Press PROG key to change to the next menu item. To exit the menu and return to the program operation, press Hold/Run Key. If no keys are pressed within fifteen Seconds, the thermostat will revert to normal operation.
1)Single Stage, Multi-stage or Heat Pump System Configuration This control can be configured for Heat Pump or two stage heat/one stage cool multi-stage operation. The display indicates “STD2” (default for multi-stage mode) in the display. The Multi-stage configuration can be toggled to “SS1”, or “HP1” by pressing the up or down key. In Multi-stage configuration, EMER mode is useless. 2This thermostat is configured from the factory to operate a heat/ cool, fossil fuel (gas, oil, etc.), forced air system. It is configured correctly for any system that DOES NOT require the thermostat to energize the fan on a call for heat. If you system is an electric heat or heat-pump system that requires the thermostat to turn on the fan on a call for heat, locate the HE/HG in the menu and SELECT it to the HE position. This will allow t he thermostat to energize the fan immediately on a call for heat. If you are unsure if the heating/ cooling system requires the thermostat to control the fan, contact a qualified heating and air conditioning service person. When the thermostat is configured for Heat Pump, the thermostat will always power the circulator fan on a call for heat in the HEAT mode. The HE/HG must be set to match the type of Auxiliary heat your system uses for proper operation in the EMER gency mode. All wiring diagrams are for typical systems only. Refer to equipment manufacturers’ instructions for specific system wiring information.
3) Select Energy Management Recovery OFF or ON Your thermostat is set from the factory to gradually recover the room temperature from an energy saving program to your comfort program. Therefore, the thermostat may turn your system on several minutes prior to your programmed.
4)Fast or Slow Crycle Selection(one stage)
5)Select Backlight function OFF or on
6) Fast or Slow Crycle Selection(two stage)
7)Select °F or °C Readout. when you change this parameter. the programming come back to fault. you have to set the programming again. Changes the display readout to Centigrade or Fahrenheit as required
8) Selects time format display 12hours or 24hours
9)Select Compressor Lockout COMP OFF or ON Selecting COMP ON will cause the thermostat to wait 4 minutes before turning on the compressor if the heating and cooling system loses power. It will also wait 5 minutes minimum between cooling and heating cycles. This is intended to help protect the compressor from short cycling. Some newer compressors already have a time delay built in and do not require this feature. Your compressor manufacturer can tell you if the lockout feature is already present in their system. When the thermostat compressor time delay occurs it will flash the set point for about four minutes.
10) This mode be use to setting commucation channels. The thermostat and controller must be re-match when change the channales.
11) This model select 1 to back factory Default. The thermostat and controller must be re-match.
Setting Time And Day
Remove the mylar label covering the LCD display window before operating thermostat.
Initial display after power-up. The temperature will update after a few seconds.
EXAMPLE: Set the Thermostat to the current time of 9:43 a.m. on
Saturday Refer to Figure at right
During time and day setting mode , the temperature
Press Display Reads Step 1 Press Day/Time key. The current hour and AM or
PM indicator areflashing.
Press to change the hour. Note AM/PM
Step 2 ■Press Day/Time key again.The current min is
flashing.
Press to change the min.
Step 3 Press Day/Time key. The current week is flashing.
Press to change the week.
After 30 seconds, the thermostat will return to normal automatically.
Manual Programming
Your thermostat can be programmed for weekdays and weekends, or have unique programs for all 7 days. Use Weekday /Weekend Programs or 7-day Programming to enter or revise programs to match your Personal Program Schedule. The same steps are used when entering programs for the first time, or revising programs entered du ring Auto Programming.
Familiarize yourself with Manual Programming, so that you can easily modify your programs as your comfort needs change. The example below demonstrates the Manual Programming method.
NOTE:
1The program time can be set in 10-minute increments, and remains the same for both Heat and Cool programs. 2The program temperature can be set in increments of 1˚F (1˚C). 3The Heat setpoint can not be set higher than the Cool set point, and the Cool set point can not be set lower than the Heat set point. 4When setting the program time, note the AM/PM indicator. 5 With the Auto Recovery feature enabled, you do not need to set your comfort program times early. Auto Recovery will determine how early Recovery will determine how early to turn your system on, so that the room is comfortable at the program time.
Weekday/Weekend Programming Weekday
Programs
Press Display Reads
Normal display of time, temperature, and day of the week.
Step 1 Selects days Mon to Fir for same set of 4
programs each day.
Step 2 Program indicator(1) is displayed.
Mon to Fir is displayed.
Step 3 ■The Program hour and AM or PM indicator are
flashing. Pre ss to change the hour.
Note AM/PM
Step 4 Press again to change to the minute position. The
period minute will be flashing.
Press to change the minute
Step 5 ■ Press again to change to the program COOL set
temperature. The period program will be flashing.
Press to change the temperature.
Note HEAT/COOL
Step 6 ■ Press again to change to the program HEAT set
temperature. The period program will be flashing.
Press to change the temperature.
Note HEAT/COOL
Weekday program 1 is complete.
Step 4 ■ Press PROG to move to program 2,3, and 4 and follow the same steps.
Use to insert or change time and temperature of other
Programs.
Selects weekend days Sat, Sun for same set
of 4 programs each weekend day.
Follow steps 2-4 to enter programs.
Similar to weekday programming.
to insert weekend programs.
Similar to weekday programming.
to insert Individual programs.
NOTE: Another approach to programming is to first program all weekdays Mon through Fir and Sat and Sun as same programs. Then, display and change the programs of only those days which will have different programs. Temporary Manual Override
To temporarily change the current set temperature without affecting your program:
Press up or down key for less than 1 second to enter Manual Override mode..
Press up or down to change to your desired new temperature.
Press to RUN to normal mode or wait 20 seconds for it to
return automatically.
The current program number will flash to signify the Temporary Override. At the next program change, the Temporary Override is canceled, and the next program temperature becomes the setpoint temperature. To end the Temporar y Manual Override:
Press HOLD key twice. This will return the set temperature to the current
program set temperature. NOTE: The Auto Season Changeover feature will not operate while the thermostats is in Temporary Manual Override. Refer to the Auto Season Changeover feature for more information.
Permanent Override or a Designated Day Override
To hold your Manual Override for vacation or Until a Designated Day.
Press to make the current program temperature the HOLD temperature. HOLD will be displayed on the LCD, and the Program number will disappear.
Follow the Temporary Manual Override instructions above to change the Permanent Manual Override temperature.
You can confirm the held set temperature by pressing for less than 1 second.
Press again. Hold day will be displayed on the LCD and the clock
will disappear
Press Day/Time key to adjust override days.
Follow the Permanent Override instructions above to change
the a Designated Day Manual Override temperature.
To end Override:
Under Permanent Override Press hold key twice. Under a Designated Day Override press the hold once. The thermostat will return to the current program, and the HOLD display will be canceled. NOTE: The Auto Season Changeover feature will not operate while the thermostat is in permanent Manual Override. Refer to the Auto Season Changeover feature for mor e information.
Auto Season Changeover
When the System Selector is in AUTO position , the thermostat will automatically change between Heating and Cooling systems, depending on your program. We recommend keeping your programmed heating and cooling temperature at least 2 ˚F (2˚C) apart to allow the Auto Season Changeover to occur when the appropriate temperature span has been reached. However, if your heating and cooling programs set temperatures are close, there is a built-in program to prevent the thermostat is in Temporary, a Designated Day Override or Permanent Override, as these overrides ar e energy saving settings. Auto Season Changeover will still function in Override mode, as this is a comfort setting. For example, you may have the following temperatures programmed at a given time: Heat Set Temp=68˚F, Cool Set Temp=78˚F If the room temperature rises above 78˚F, then the thermostat will automatically change to cool mode and turn on the air conditioner. Likewise, the thermostat will automatically change to heart mode and turn on heat when the room temperature falls below 68˚F.
Filter Monitor
Your thermostat also keeps a record of the number of Days your filter has been in use. To maximize your system’s performance and energy efficiency,change or clear your filter regularly.
When the total fan run time reaches 400 hours, you need clean or change your system’s filter, “FILTER” will continue to display until the counter is set back to zero.
Press to review total filter usage. The “FILTER” display. Then show the filter Monitor counter . After 20 seconds, the display will return to normal mode, or you can hit RUN to exit immediately. The Filter Monitor will display up to 100 Days of usage. In this example, the counter is at10 Days.
To reset the Filter Monitor counter, depress FILTER for 3 seconds when the filter monitor day show. The display will blink, and the counter will be reset to zero.
Auto Recovery
uto Recovery calculates how early to turn your system back on, so that the room temperature is already comfortable by the start of the comfort temperature program period. Auto Recovery work’s in both Heat and Cool modes.
When the thermostat is in Auto Recovery mode, the display will alternate “RECO” with time, and the program indicator will lcddisp.
Auto Recovery can be disabled by menu setting.
Auto Recovery will not operate if Permanent hold or Temporary hold is
in operation.
Auto Recovery can be canceled manually if HOLD is pressed during the recovery process.
Auto Recovery will be canceled and change to next period.
Keyboard lock
The keyboard can be locked to prevent unauthorized changes to the thermostat. To lock or unlock the keyboard, press and hold run Key for 3 seconds. The keyboard is locked. when LOCK appears on the display.
All keys are locked, Any time a key is pressed, LOCK will appear on the display for 1 second.
Error Mode
If the thermostat is unable to control your system due to an unexpected problem, the thermostat will enter Error Mode. In this condition, the thermostat flashes “E1”,“E2” on the LCD display, and shuts off your system..
Lcd display informati on Lcd display information
E1 Sensor Error E2 System switch
Low Battery Warning
Your thermostat has battery warning system. When the batteries are first detected to be weak, the first stage low battery warning is indicated by battery symbol flashing on the LCD display. At your earliest convenience, you need to charge the batteries through USB. Duing Charge process the battery icon will flash one by one.When the battery charge complete.the battery icon will disappear.
Reviews filter usage in hours and minutes. Also resets filter counter to zero.
Front Door: To open or close the door by pushing it softly
Soft touch programming and functions buttons (see below)
Up and Down Key:Key for changing the Temperature setting. Also used for increasing and decreasing selections in the Time,Program,and Span functions.
LCD Display:Shows Time,Day,Temperature, and other feature information as required.
For entering day or time.
Enters Program Mode for reviewing and changing weekday, weekend,or daily programs.
Mode.
Selects the day or days to review or change in Program
Fan key: For automatic or continuous fan operation.
FAN
MODE
PROG
DAY
PROG
TIME
DAY/
HOLD /RUN
Today mode.
control from manual override or Home
returns the thermostat to current program
time and temperature.
Returns display to current
by overriding stored programs. It also
Provides permanent temperature setting
Selects the system mode for Heat and Cool,Auto heat, Emer,or Off.
TIME
DAY/
M
O
.
PM
TIME
DAY/
TIME
DAY/
M
O
.
PM
M
O
.
PM
M
O
.
PM
Room
1
AUTO
SYSTEM
OFF
FAN
PROG
DAY
SA. SU.
M
O
.
TU. WE. TH.
FR.
PROG
M
O
.
PM
Room
1
AUTO
SYSTEM
OFF
FAN
PROG
PROG
PROG
PROG
PROG
DAY
PROG
PROG
DAY
PROG
PROG
DAY
PROG
HOLD /RUN
HOLD /RUN
SA. SU.
AM
PermanentOverride
AUTO
SYSTEM
HEAT
FAN
DAYS
OverrideUntil
AUTO
SYSTEM
FAN
COOL
TH.
PM
PermanentOverride
AUTO
SYSTEM
HEAT
FAN
HOLD /RUN
HOLD /RUN
TIME
DAY/
DAYS
FILTER
M
O
.
PM
2
AUTO
SYSTEM
HEAT
AUTO
FAN
Room
M
O
.
2
AUTO
SYSTEM
HEAT
FAN
Room
M
O
.
AM
1
AUTO
SYSTEM
HEAT
FAN
M
O
.
TU. WE. TH.
FR.
SetTo
1
COOL AUTO
PM
M
O
.
TU. WE. TH.
FR.
SetTo
1
COOL
AUTO
PM
M
O
.
TU. WE. TH.
FR.
SetTo
1
PM
COOL
M
O
.
TU. WE. TH.
FR.
SetTo
1
PM
HEAT
M
O
.
PM
Room
1
SYSTEM
OFF
FAN
ON
A3900 Series Controller manual
GENERAL
A3900 Series wireless sets is designed to control the room temperature in Industrial, commercial and residential environment. It includes A3900 Series Wireless Thermostat and A3900 Series Controller, by wireless data communication between thermostat and controller, transfer receive and carry out the control dictate and signal, and realize the controlling of temperature.
Read This Before Installing controller
OPERATION
The A3900 Series Controller receive the signal from Wireless Thermostat without any wires, and control cooling and heating equipment.
YOUR THERMOSTAT REPLACES
Description Heat Pump (No Aux. or Emergency Heat) Yes Heat Pump (with Aux. or Emergency Heat) Yes Standard Heat & Cooling Systems Yes Two Stage Heat & Two Stage Cool Yes Standard Heat Only Systems Yes Millivolt Heat Only Systems– Floor or Wall Furnaces
Yes
Standard Central Air Conditioning Yes Gas or Oil Heat Yes Electric Furnace Yes Hydronic (Hot Water) Zone Heat-2 Wires Yes Hydronic (Hot Water) Zone Heat–3 Wires No
This Thermostat will NOT control 110/220Volt systems.
POWER SUPPLY The A3900 Series Controller shall be powered by 24 VAC.
MATCHING
The thermostat and controller will work only when they are match successful, and realize 1-1 control. Step 1 (Controller): Power on the controller, press the match key for less than one second (The key is on the right side of the controller, don’t press the key long). The controller will receive the register matching data from the thermostat, user should finish registration in 1 minute, if the controller haven’t received the matching dictate in 1 minute, the controller matching data will come back to the data of last time automatically. Step 2(Thermostat): Press “MODE” key to “OFF” mode, then press “PROG” key for 3 seconds until the screen changes to menu setting. Press “PROG” key until LCD display “CRES”, use up key to change the parameter to “01” and thermostat will match automatically. Matching is finished.
TESTING
Similar to menu setting. Step 1 Press “PROG” key, until it displays “TEST”, change the parameter to “02” by press up key , the relays will open one by one. Step 2 Testing is finished, press “RUN” key to exit setting state, and the equipment could work.
Note: This item is only for testing, not for normal output. if the wires be connected .this test may be dangerous. NOTE: The distance between the thermostat and controller should be long than 1m, if not it may fail communication. It should go back to the first step if the rela y don’t have output in the third step.
On the condition that thermostat and Controller haven’t matched, Controller output testing:
press the key (on the right side of the controller) and hold it over 3
seconds, relays will open and close one by one. Program will exit testing after thrice circle. If user want to exit testing before three circle finished, press the key on the side fo r 3 seconds is OK.
Technical Data
Power AC24±5V,50/60Hz Working environment 0 ℃~50℃ Range 5~95%RH(non-condensing) Shell Fire retardant PC ABS Dimension 116×98×45 mm(HxWxD) Connection interface Each terminal capable of accepting 2 x 1.5 mm2
or 1 x2.5mm2 wireselectric heating type:1 x 4
mm2 wires Wireless carrier wave frequency 433MHz Current 28 mA Communication baud rate 10 kbps Wireless channels 1~10 channels Communication distance Beeline distance 30m in the field(The distance will
shorten if through walls and floors)
COMPRESSOR PROTECTION
The thermostat provides a 4 minutes delay after shutting of the heating or cooling system before it can be restarted. This feature will prevent damage to your compressor caused by rapid cycling. Note that this delay also applies to the heating system control. It does not provide a delay when there are power outages. you can select the function on or off at the configuration.
THERMOSTAT OUTPUT Standard Terminal Outputs:
Refer to equipment manufacturers' instructions for specific system wiring information. You can configure the controller for use with either multi-stage electric heat systems or multi-stage gas systems. When configured for electric heat, the G terminal (blower/fan) will be energized on a call for heat. This thermostat is designed to operate a single-transformer system. If you have a two-transformer system, cut and tape off one transformer. If transformer safety circuits are in only one of the systems, remove the transformer of the system with NO safety circuits. If required, replace remaining transformer with a 75VA Class II transformer. After disconnecting one transformer, the two commons must be connected together. Use the terminal output information below to help you wire the thermostat properly for your multi-stage system. After wiring see CONFIGURATION section for proper thermostat configuration.
THERMOSTAT TERMINALS SYSTEM Single-stage Multi-stage C* 24 Volt(Common) R 24 Volt Emergency (hot) E/W1 Heat mode 1st stage W2 No output Heat Mode 2nd stage Y1 Cool Mode 1st stage Y2 No output 2nd stage compressor G
Blower/Fan Energized on call for Cool (and Heat if configured to
Electric Heat) O No output B No output
Heat Pump Terminal Outputs
Refer to equipment manufacturers' instructions for specific system wiring information. You can configure the thermostat for use with the following heat pump system types: Single stage compressor system; gas or electric backup. This thermostat is designed to operate a single-transformer system. If you have a two-transformer system, cut and tape
off one transformer. If transformer safety circuits are in only one of the systems, remove the transformer of the system with NO safety circuits. If required, replace remaining transformer with a 75VA Class II transformer. After disconnecting one transformer, the two commons must be connected together. Use the terminal output information below to help you wire the thermostat properly for your heat pump system. After wiring, see CONFIGURATION section for proper thermostat configuration.
THERMOSTAT TERMINALS (HEAT PUMP) SYSTEM Heat Pump 1 Heat Pump 2 C* 24 Volt(Common) R 24 Volt Emergency (hot) E/W1 Emergency Mode 1st stage W2 HP 1 and Emergency 2nd stage Y1 Heat and Cool mode 1st stage (compressor) Y2 No output 2nd stage compressor G
Blower/Fan Energized on call for Heat and Cool
Set GAS/ELEC switch for Emergency mode O Energized in Cool Mode B Energized in Heat Emergency mode
WIRING
Cool only system
Heat only system
1-stage cooling , heating system for normal mode
2-stage cooling , heating system for normal mode
1-stage cooling, heating system for heat pump
2-stage cooling, heating system for heat pump
INSTALLATION
Installation guide
What You Need This thermostat includes two #8 slotted screws and two wall anchors for mounting. To
install your controller, you should have the following tools and materials.
Slotted Screwdriver(s) ■ Small Philips screwdriver ■ Hammer
Electric drill and 3/16” bit
CAUTION: To prevent electrical shock and/or equipment dam- damage, age, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
WARNING Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.
TROUBLESHOOTING
Problem Solution SCRAMBLED OR DOUBLE DISPLAY (numbers over numbers)
1.Remove clear mylar sticker.
NO DISPLAY 1.Charge Li-battery ENTIRE DISPLAY DIMS
1.Charge Li-battery
PROGRAM DOES NOT CHANGE AT YOUR DESIRE SETTING
1.Check that the time is set properly to “AM” or “PM”
2.Check that the thermostat is not in “HOLD” mode.
3.Check for the correct day settings.
AUTO/FAN DOES NOT TURN ON
1.Change HE/HG parameter to opposite setting .
2.The thermostat may be in the AUTO Mode. Look for ”AUTO” on the LCD display. If the Heat and Cool program temperature are close, then the thermostat requires a larger room temperature change before changing from Heat or Cool.
3. There may be as much as 4 minute delay before the Heat or Cool system turns On-wait and check. (Compressor protection delay). 4Check your circuit breaks and switches to ensure there is power to the system.
6. Make sure your furnace blower door is closed properly. ERRATIC DISPLAY 1.Replace uni t. CONTROLLER NO OUTPUT
1.Check if the thermostat is working, if the thermostat is
effective, and if the power is supplied to the controller.
2.Check if the communication is correct, the controller will
close all the relays if there is no data received in 30 minutes.
3 Match the thermostat and the controller again. COMMUNICATION FAILED
1. Check if the thermostat is working, if the therpstat is
effective, and if the power is supplied to the controller.
2.The distance between the thermostat and controller
should be longer than 1m, shorter than 100m in the field.
3 Match the thermostat and the controller again.
If you experience any other problems, call us for technical assistance.
A3900 Series Controller
Key position
Y1
W2
E / W1
NC
R
CONV. HP
FAN RELAY
Y2
B
O
G
C
Controller
HEAT RELAY
IN AC24V
Y1
W2
E / W1
NC
R
CONV. HP
FAN RELAY
Y2
B
O
G
C
Controller
COOL RELAY
IN AC24V
Y1
W2
E / W1
NC
R
CONV. HP
FAN RELAY
Y2
B
O
G
C
Controller
COOL RELAY
HEAT RELAY
IN AC24V
Y1
W2
E / W1
NC
R
CONV. HP
FAN RELAY
Y2
B
O
G
C
HEAT RELAY 2
Controller
COOL RELAY 2
COOL RELAY 1
HEAT RELAY 1
IN AC24V
Y1
W2
E / W1
NC
R
CONV. HP
FAN RELAY
Y2
B
O
G
C
HEAT (AUX)
EMER
CHANGE OVER VALVE
COMPRESSOR
Controller
IN AC24V
Y1
W2
E / W1
NC
R
CONV. HP
FAN RELAY
Y2
B
O
G
C
HEAT (AUX)
EMER
CHANGE OVER VALVE
COMPRESSOR 2
COMPRESSOR 1
Controller
IN AC24V
Loading...