Introduction
The unit is carefully calibrated at the factory. The performance may change over time or due to environmental changes, then the following recalibration procedures will help bring it back to its factory settings.
Calibration Procedure
The CALIBRATION menu in the SYSTEM SETTINGS menu allows you to perform CALIBRATION of the VOICES and PEDAL INPUT.
Follow all steps in the order in which they are presented.
Calibration Menu
To navigate the options in the CALIBRATION menu, use the BANK/UP or BANK/DOWN switches.
Selected parameters are adjusted using the -/NO or +/YES switches, the rotary knob or the DATA ENTRY fader. The rotary knob has a click which allows very accurate control. The fader allows rapid adjustment across the full range.
In order to start a calibration routine, make sure that the '<' symbol on the appropriate CALIBRATE line is highlighted, and then press the +/YES switch.
985-40000-01100 Rev.A 2021-02-03
Condential, for internal use only. Not to be reproduced.
page 1 of 5
Synthesizers and Samplers
DEEPMIND 12D
The DeepMind 12D has 12 voices. Each voice has its own LFO, OSC, VCF, ENV and VCA stages.
The CALIBRATION routine is used for Voice checking, OSC wave shapes, VCF self-oscillation, Pulse Width modulation and the VCA bias.
VCF - Unlike many other synthesizers, the DeepMind 12D is capable of accurate pitch tracking even when the lter resonance is pushed to (and past) the point where the lter starts to self-oscillate. When using this self-oscillating feature of the VCF as a sound source, the VCF calibration ensures the correct response when playing the entire scale of the keyboard.
The DeepMind 12D VCFs are calibrated at the factory during production. However, because its lters are voltage controlled and can be aected by extremes of temperature, you may need to use the built-in calibration function to ne tune them occasionally. Calibration may also be required after a rmware upgrade or when requested to do so by an authorized Behringer support technician.
OSC - The DeepMind 12D OSCs are calibrated at the factory during production. The oscillators are discrete analog circuits, but they are digitally controlled. Compared to a Voltage Controlled oscillator (VCO), the OSC has far superior stability, especially when they have very high frequency, low-jitter master clock sources, as used in the DeepMind 12D. This stage calibrates the slope of the sawtooth waveform to ensure even volume and pulse-width across the full range of the synthesizer.
This means that the OSCs should never need re-calibrating except after a rmware upgrade, or when requested to do so by an authorized Behringer support technician.
CALIBRATE VOICES
Overview of the calibration routines:
ALL - This will initiate all of the routines.
VOICE CHECK - This performs a series of functionality tests on each voice.
VCF - This routine puts the voice into self oscillation and tunes to 1 kHz in order to calibrate the resonance of the VCF
for that voice. The routine then puts the voice into self oscillation and checks the tuning at 50 Hz, 220 Hz, 880 Hz and 10 kHz to ensure the VCF is performing as expected. The test is repeated for all voices.
VCF FINE - This routine tests the scale and oset for all voices.
OSC - This routine adjusts the slope of the sawtooth at octave intervals. This ensures the precision of the slope so that it
performs as designed. The test is repeated for all voices.
PW - This routine adjusts the pulse width (mark to space ratio) of the pulsewave. This ensures the precision of the ratio so that it performs as designed. The test is repeated for all voices.
VCA - The Voltage Controlled Amplier (VCA) uses a bias voltage to set its operating level. This bias voltage is balanced so that the VCA responds as designed. The test is repeated for all voices..
page 2 of 5page 2 of 5
Synthesizers and Samplers
DEEPMIND 12D
To start the calibration routine, please follow the procedure below:
In order to start the calibration routine, make sure that the '<' symbol is on the appropriate CALIBRATE line and highlighted, and press the +/YES switch.
NOTE: The calibration run time is shown on the bottom of the screen so that you can plan your work around any of the calibration phases.
The calibration routine will then start. Throughout the tests you will see various waveforms being played. It is safe to turn down the volume while the calibration routine is running.
NOTE: While the calibration is running, you can mute the signal using the BANK/DOWN switch and un-mute using the BANK/UP switch.
When the calibration routine is complete, you will see a summary of the test results as shown below. The 1st column is Voice 1, 2nd is Voice 2, and so on:
NOTE: During the calibration, the GLOBAL and -/NO switches will be ashing. If at any time you want to cancel the calibration routine, you can press the -/NO switch. No previous calibration data will be changed if you cancel the routine.
page 3 of 5page 3 of 5
Synthesizers and Samplers
DEEPMIND 12D
CALIBRATE PEDAL
To calibrate the PEDAL please use the following process:
NOTE: During the calibration the GLOBAL, -/NO and +/YES switches will be ashing. If at any time you want to cancel the calibration routine, you can press the -/NO switch. No previous calibration data will be changed if you do cancel the routine. To conrm the calibration at each stage press +/YES as described below.
In order to start the calibration routine, make sure that the '<' symbol on the CALIBRATE PEDAL line is highlighted and press +/YES.
You will see the following display showing a bar representing the current PEDAL value (0% for no pressure). Also on this screen you can see the stored calibration data above the bar and the current value below the bar:
Then press the pedal until the value stops increasing.
You will see the following display showing the maximum position of the PEDAL input and the associated value:
page 4 of 5page 4 of 5
Synthesizers and Samplers
DEEPMIND 12D
NOTE: To cancel the routine, press the -/NO switch, and you will see the following message:
To conrm the CALIBRATION of the PEDAL input, press the +/YES switch: The calibration data will then be stored for the PEDAL and you will be returned to the CALIBRATE menu. From here you can perform another calibration from the menu, or press the GLOBAL switch again to return to the SYSTEM SETTINGS menu.
End of Procedure
Music Tribe accepts no liability for any loss which may be suered by any person who relies either wholly or in part upon any description, photograph, or statement contained herein. Technical specications, appearances and other information are subject to change without notice. All trademarks are the property of their respective owners. Midas, Klark Teknik, Lab Gruppen, Lake, Tannoy, Turbosound, TC Electronic, TC Helicon, Behringer, Bugera, Oberheim, Auratone and Coolaudio are trademarks or registered trademarks of Music Tribe Global Brands Ltd. © Music Tribe Global Brands Ltd. 2021 All rights reserved.