ADRStudio.com –SYSEX for DSP8024 - Compiled by Adriano Ficarelli Jr.
ADRStudio.com
SYSEX COMMANDS FOR BEHRINGER ULTRA CURVE PRO DSP 8024
Compiled by Adriano Ficarelli Jr - ADRStudio.com
03/27/2003 - Rev.13
Note:
The information below I obtained by dumping the communication between DSP8024 and my computer.
Discovering one by one, and figuring out how they work. Some at bit level.
As you know, Behringer original manual does not have any information about SYSEX, and BEHRINGER
support does not provide this information too.
All commands work fine, but some are missing. The most important for me that are missing: the reset of
HOLD Curve of RTA, and, switch between LEFT and RIGHT on EQ display.
The reset of RTA can easily be simulated by switching the input to MICRO and then back to L+R. If no
Microphone, it zeroes the Hold. Switching the Decay Time also resets the Hold curve.
Others missing commands that should be very useful are switch to the LEVEL METER and to FEED BACK
DESTROYER (or Parametric EQ). They probably it will never work because, unfortunately, inside these
screens, the SYSEX receive is disable, so nothing change when you send SYSEX commands, and you can't
send a command to return to the EQ main screen also. Only changing the Operating System
can make it possible (it means write and change EPPROMs, etc.).
Special thank's for Florian Bömers ( www.bome.com ) for the tool SendSX.
Page 2
ADRStudio.com –SYSEX for DSP8024 - Compiled by Adriano Ficarelli Jr.
SEND DATA
GENERAL OPTIONS
Analyze IN/OUT 02h
(IN = BYPASS)
xx = 00h IN
xx = 01h OUT
F0 00 20 32 00 0E 02 xx F7
Switch Equalizer/RTA 08h
xx = 00h Equalizer
xx= 01h RTA
F0 00 20 32 00 0E 08 xx F7
EQUALIZER OPTIONS
Graphic Equalizer
Frequency level 10h
sr = 00h to 1Eh for left channel/frequency
sr = 20h to 3Eh for right channel/frequency
sr will be 00h = 20 Hz, 01h = 25Hz ..... 1Eh = 10 kHz for left channel
sr will be 20h = 20 Hz, 21h = 25Hz ..... 3Eh = 10 kHz for right channel
xx = 0 to 64 - level
sr will be 00h = 20 Hz, 01h = 25Hz ..... 1Eh = 10 kHz for left channel
sr will be 20h = 20 Hz, 21h = 25Hz ..... 3Eh = 10 kHz for right channel
F0 00 20 32 00 0E 10 sr xx F7
Master Volume 11h
s = channel, 0 = Left, 2 = Right
xx = 0 to 64 (-16 to + 16 dB, inc .05)
F0 00 20 32 00 0E 11 s0 xx F7
EQ Limiter Threshold 12h
xx = 0 OFF
xx = 1 to 37 dB
Page 3
ADRStudio.com –SYSEX for DSP8024 - Compiled by Adriano Ficarelli Jr.
F0 00 20 32 00 0E 12 xx F7
EQ Limiter Release 14h
xx = 0 to 18, each means inc of .5 seconds
F0 00 20 32 00 0E 14 xx F7
EQ Noise Gate 15h (Both channels)
xx = 0 OFF
xx = 1 to 47 (-96 dB to -44 dB)
F0 00 20 32 00 0E 15 xx F7
Delay 19h
xx = 0 OFF
xx = 1 ON
F0 00 20 32 00 0E 19 xx F7
DELAY time/distance 1Ah
s = channel, 0 = Left, 2 = Right
3 bytes counter, zz less significant
F0 00 20 32 00 0E 1A s0 xx yy zz F7
Page 4
ADRStudio.com –SYSEX for DSP8024 - Compiled by Adriano Ficarelli Jr.
Parametric Equalizer (PE)
PE Mode 1Eh
s = channel, 0 = Left, 2 = Right
b = 0 - 1st band
b = 1 - 2nd band
b = 2 - 3rd band
xx = 0 OFF
xx = 1 PAR
xx = 2 AUT
xx = 3 SGL
F0 00 20 32 00 0E 1E sb xx F7
PE Frequency 1Fh
s = channel, 0 = Left, 2 = Right
b = 0 - 1st band
b = 1 - 2nd band
b = 2 - 3rd band
yy = 00 - 20 to 87 Hz
yy = 01 - 88Hz to 378.75Hz
yy = 02 - 383.00 Hz to 1.66 kHz
yy = 03 - 1.68 kHz to 7.235 kHz
yy = 04 - 7.32 kHz to 20 kHz ( here xx max = 58H )
xx = 0 to 127 (not that the real variation is not linear)
F0 00 20 32 00 0E 1F sb yy xx F7
PE Octave 20h
s = channel, 0 = Left, 2 = Right
b = 0 - 1st band
b = 1 - 2nd band
b = 2 - 3rd band
xx = 0 to 120 (1/60 to 120/60)
F0 00 20 32 00 0E 20 sb xx F7
PE GAIN 21h
s = channel, 0 = Left, 2 = Right
b = 0 - 1st band
b = 1 - 2nd band
b = 2 - 3rd band
Page 5
ADRStudio.com –SYSEX for DSP8024 - Compiled by Adriano Ficarelli Jr.
xx = 0 to 127 (- 48 to + 16 dB, inc .5)
F0 00 20 32 00 0E 21 sb 00 xx F7
Cross fade time 23h (Both channels)
xx = 0 to 15 (sec)
F0 00 20 32 00 0E 23 xx F7
Shelving Slope 24h
xx = 0 to 10 (each = 3dB/Oct)
F0 00 20 32 00 0E 24 xx F7
Page 6
ADRStudio.com –SYSEX for DSP8024 - Compiled by Adriano Ficarelli Jr.
RTA OPTIONS
RTA Sampling 25h
xx = 2 - Analog 44.1 kHz
xx = 3 - Analog 48.0 kHz
F0 00 20 32 00 0E 25 xx F7
RTA INPUT 28h
xx = 0 MICRO
xx = 1 Left
xx = 2 Right
xx = 3 Left + Right
F0 00 20 32 00 0E 28 xx F7
RTA Hold 29h
xx = 0 OFF
xx = 1 ON
F0 00 20 32 00 0E 29 xx F7
RTA Resolution 2Ah
xx = 0 - 1 dB/pix
xx = 1 - 0.5 dB/pix
F0 00 20 32 00 0E 2A xx F7
RTA Auto Gain 2Bh
xx = 0 OFF (Manual)
xx = 1 ON
F0 00 20 32 00 0E 2B xx F7
RTA LINE Gain 2Ch
xx = 0 to 16 ( 0 to 60 dB, inc de 4 dB)
F0 00 20 32 00 0E 2C xx F7
*
RTA MIC Gain 2Dh
xx = 0 to 16 ( 0 to 60 dB, inc de 4 dB)
F0 00 20 32 00 0E 2D xx F7
Page 7
ADRStudio.com –SYSEX for DSP8024 - Compiled by Adriano Ficarelli Jr.
RTA MIC Correction 2Eh
yy xx, two byte counter 0 to 200, 100 options for each channel.
F0 00 20 32 00 0E 2E yy xx F7
RTA MODE 2Fh
xx = 0 RMS
xx = 1 Peak
F0 00 20 32 00 0E 2F xx F7
RTA DECAY 30h
xx = 0 - 15 ms
xx = 1 - 65 ms
xx = 2 - 250 ms
xx = 3 - 1.0 s
F0 00 20 32 00 0E 30 xx F7
RTA Q-Curve 31h
xx = 0 Flat
xx = 1 to 100 - 100 curves
F0 00 20 32 00 0E 31 xx F7
RTA OUTPUT 32h
xx = 0 OFF
xx = 1 Input
xx = 2 Sine
xx = 3 White
xx = 4 Pink
F0 00 20 32 00 0E 32 xx F7
RTA Sine Frequency 33h
yy xx, two byte counter
F0 00 20 32 00 0E 33 yy xx F7
RTA Level of noise generator 34h
xx = 0 to 48
F0 00 20 32 00 0E 34 xx F7
Page 8
ADRStudio.com –SYSEX for DSP8024 - Compiled by Adriano Ficarelli Jr.
MEMORY OPTIONS
Write to a EQ memory slot 46h mmh
This function writes into a memory slot of the EQ all its settings. It is composed by a header that have the
memory slot number, followed for all settings. At the end it have the name you give as a remark for this slot.
F0 00 20 32 00 0E 46 mm - header, where mm is the slot number (0 to 63h)
then
2 times Delay Time (one for each channel)
62 times Frequency Level
2 times Master Volume
6 times PE Mode
6 times PE Frequency
6 times PE Octave
6 times PE GAIN
and then the name or remark for the slot 3Ch
3C aa aa aa aa aa aa aa aa aa aa aa aa
where aa will be the index of the following table:
!"#$%&'()*+,-./
Obs: The first char and after ~ there is a space char. Where you see =, is because I can't generate that char.
then
F7 finish the string
Ex: it should be something like this:
F0 00 20 32 00 0E 46 02 1A 00 00 00 03 1A 20 00 00 00 10 00 2B 10 01 2D 10 02 20 10 03 20 10 04 20 10
Limiter Release
Noise Level
2 times Delay Time (one for each channel)
62 times Frequency Level
2 times Master Volume
then the following block repeat 6 times:
(note that here is different from writing into a slot)
PE Mode
PE Frequency
PE Octave
PE Gain
then
RTA Input
RTA Resolution
RTA Hold status
RTA Auto Gain Status
RTA Mode Peak/RMS
RTA Line Gain
RTA Mic Gain
RTA Mic Correction
RTA Decay
RTA Q-Curve
RTA OUTPUT
RTA Sine Frequency
RTA Level of noise generator
EQ Crossfade time
EQ Shelving Slope
and then a name or remark. It use to be the most recent slot loaded.
3C aa aa aa aa aa aa aa aa aa aa aa aa
then F7 finish the string
It should be something like this:
F0 00 20 32 00 0E 12 25 14 00 15 14 1A 00 00 00 03 1A 20 00 00 00 10 00 24 10 01 20 10 02 20 10 03 20
ADRStudio.com –SYSEX for DSP8024 - Compiled by Adriano Ficarelli Jr.
TIPS:
You can combine two or more commands. The string "F0 00 20 32 00 0E" is the header for sending
commands to DSP8024. This way you can send one header followed by the strings of the commands you
want to send, and put "F7" to finalize the line.
See examples below:
1. Changing EQ master volumes level of both channels at the same time and synchronized ( volume
command is "11 s0 xx" ):
F0 00 20 32 00 0E 11 00 xx 11 20 xx F7 where xx is the desired level.
2. Put all frequencies at level zero (frequency level string is "10 sr xx") :
"F0 00 20 32 00 0E 10 00 20 10 01 20 10 02 20 10 03 20 10 04 20 10 05 20 10 06 20 10 07 20 10 08 20 10
Note that you can include the string "11 00 20 11 20 20" just before the "F7" so you can zero the master
volume at the same time. Remember that 20h is the middle, means zero dB.
Page 12
ADRStudio.com –SYSEX for DSP8024 - Compiled by Adriano Ficarelli Jr.
REQUEST DATA
The most simple way to request data from DSP 8024 is just send the header "F0 00 20 32 00 0E" or "F0 00
20 32 7F 0E" followed by "70" and by the parameter number you want to request and close the
string with "F7".
Ex: To request the level of Noise Threshold just send:
F0 00 20 32 00 0E 70 15 F7 (or F0 00 20 32 7F 0E 70 15 F7)
you will receive the string:
F0 00 20 32 00 0E 15 xx F7 where xx will be the value of Noise Threshold.
Where you have more than one value for a parameter, follow the rule but add the others variable to the
string.
Ex: To request the right master level of the Graphic equalizer send:
F0 00 20 32 00 0E 70 11 20 F7
you will receive the string:
F0 00 20 32 00 0E 11 20 26 F7 when the master right level is set to +3 dB (26)
You can also combine more then one request in only one string, with the following string:
F0 00 20 32 00 0E 70 15 70 11 20 F7
you will receive:
F0 00 20 32 00 0E 15 xx 11 20 yy F7 with the Noise Threshold (xx) and right level (yy).
Real Time reading of the EQ METER 64h
F0 00 20 32 7F 0E 70 64 F7
Obs: Works only while in EQ Mode
Real Time reading of the RTA display 65h (read only)
ADRStudio.com –SYSEX for DSP8024 - Compiled by Adriano Ficarelli Jr.
Line Gain current setting - 1 byte
Mic Gain current setting - 1 byte
Decay Time current setting - 1 byte
8 bits flags (0 or 1)- Status of current Resolution, Hold, Auto Gain, Analyzer, RTA Frozen, RTA in
memory/load menu:
xxMFAGHR
R=Resolution -- 1.0 dB=0, 0.5 dB=1
H=Hold -- Hold OFF=0 , Hold ON=1
G=Auto Gain -- Manual=0, Gain Auto=1
A=Analyzer -- RMS=0, PEAK=1
F=1 when RTA display is frozen (just load from memory or pressed right/left)
M=1 when you are in MEMORY/LOADing (display is frozen, F also 1)
31 pair of bytes for each Frequency and one pair for Master Level that represent the relative position on the
display. Note that is not the actual level.
The second byte is the position, it vary from 0 to 7F, and 7F is the middle of the display (vertical). When it is
over the middle, the first byte is set to 1, and the second start over from 0.
Finally closed with F7.
Obs: Works only while in RTA Mode
Read EQ Memory slot 46h mmh
mm = 0 to 63 - each slot number
F0 00 20 32 00 0E 70 46 mm F7
Obs: The map of this string is the same for writing.
Read EQ and RTA working memory 46h 7Fh (or temp memory)
F0 00 20 32 00 0E 70 46 7F F7
Obs: The map of this string is the same for writing.
System Version (read only) 01h
F0 00 20 32 7F 0E 70 01 F7
Loading...