12v or 24v
Description
The Beckett ADC Oil Burner is designed for applications where an AC power source is not an option.
Available in 12V and 24V confi gurations, the ADC burner is conveniently powered by a standard direct
current power supply.
Features & Benefi ts
Available in either 12Vdc or 24Vdc confi gurations
•
•
Beckett GeniSys Control uses a suitable cad cell
fl ame sensor to control the motor, igniter, and
solenoid valve.
•
Interrupted duty ignition extends battery life by
only drawing full load current during the ignition
period. Intermittent duty ignition is also available.
•
Beckett CleanCut Pump has an integrated
solenoid valve for smoother light-offs and cleaner
shutdown.
•
Air Guide provides high static pressure for smooth
starts and minimal pulsation.
Specifi cations
Rated Voltage: 13.5V or 27V (Nominal Charging System Voltage)
Reference Voltage: 12V or 24V (Battery Discharge Voltage)
Capacity at Rated Voltage
▫
0.75 - 3.00 GPH
▫
105,000 - 420,000 Btu/h
Capacity at Reference Voltage
▫
0.75 - 2.50 GPH
▫
105,000 - 350,000 Btu/h
Fuels
No.1 or No.2 heating oil (ASTM D396) only
▫
Dimensions
Height: 10-1/2”
▫
Width: 14-3/8”
▫
Depth: 6-9/16” (chassis only)
▫
Ambient Operating Temperature
Min: +32°F (0°C)
▫
Max: +115°F (46°C)
▫
Electrical Ratings
Power Supply 13.5Vdc 27Vdc
Voltage range 11V - 16V 21.6V - 28V
Operating Load 15A max. 10A max.
w/ igniter off 8 - 10 Amps 6-8 Amps
Motor Voltage, nominal 13.5V 27V
Full load amps 12.1A max. 6.1A max.
Locked rotor amps 100A 50A
Flame Retention Heads (see reverse)
F3: 0.75 - 1.25 GPH
▫
F6: 0.85 - 1.65 GPH
▫
F12: 1.10 - 2.00 GPH
▫
F16: 1.50 - 2.25 GPH
▫
F22: 1.65 - 2.50 GPH
▫
F31: 2.50 - 3.00 GPH
▫
Head Styles
12v or 24v
F3
0.75 - 1.25 GPH
F16
1.50 - 2.25 GPH
F6
0.75 - 1.25 GPH
F22
1.65 - 2.50 GPH
F12
0.85 - 1.65 GPH
F31
2.50 - 3.00 GPH
USA: R.W. Beckett Corporation • ph: (800)645-2876 • fax: (440)327-1064 | Canada: R.W. Beckett Canada Ltd. • ph: (800)665-6972 • fax: (519)763-5656
www.beckettcorp.com
Form No. 6842 R12, Printed in the USA 06/10