1. LCD
2. radar antenna (narrow field)
3. radar antenna (wide field)
4. AIR-curtain width adjustment
5. AIR-lenses
DESCRIPTION
6. cover
7. main connector
8. main adjustment knob
9. AIR-curtain angle adjustment knob
ENGLISH
Opening & safety sensor for automatic sliding doors
User’s Guide for product version 0300 and higher See product label for serial number
ACCESSORIES
BA: Bracket Accessory CA: Ceiling Accessory Retrofit interface
(according to EN 16005 and DIN 18650, including emergency exits)
RA: Rain Accessory
1
max. 5 cm
NO
2
3
12-24 V
AC-DC
*
*
***
**
2
2.2 m
2.2 m
2.2 m
2.2 m
MOUNTING & WIRING
TIP!
Fixation is compatible with the ACTIV8.
RELAY OUTPUT
FREQUENCY OUTPUT
CURRENT SOURCE OUTPUT
Choose the correct radar output:
RADAR OUTPUT CONFIGURATION
RADAR OPENING IMPULSE FIELD
ANGLE
WIDTH
4 m x 2 m (wide)
2 m x 2.5 m (narrow)
field size: 9 immunity: 2
field size: 9 immunity: 2
field size: 9 immunity: 2
field size: 9 immunity: 2
The size of the detection field varies according to the mounting height of the sensor.
In emergency exits the full door width must be covered.
GREEN
BROWN
YELLOW
WHITE
PINK
GREY
RED
BLUE
YE/BK +
WH/BK -
POWER SUPPLY
OPENING INPUT
SAFETY INPUT
TEST OUTPUT
OPENING INPUT FOR EMEGENCY EXITS
* Output status when sensor is operational ** For compliance with EN 16005 and DIN 18650, connection to door controller test output is required. ***Current source output for emergency exits
15° to 45°
-15° to 15°
OR
SENSOR
YE/BK +
WH/BK -
NO: normally open NC: normally closed
NC
4
6
+
5
3
DIN 18 650 BS 7036
EN 160 05
3,50 m
3 m
2,50 m
2 m
d max = 2,5 m
d max = 3 m
3,50 m
3 m
2,50 m
2 m
max. 9 cm**
OR
WIDTH
TIP!
Additional adjustments are possible by LCD or remote control (see p. 5)
Part of the emitted field can be masked to reduce the detection field. The arrow position determines the width of the detection field.
PUSH 2X
INFRARED SAFETY FIELD
CLOSER
AWAY
If necessary, adjust the AIR-curtain angle (from -7° to 4°).
Activate the visible spots.*
ANGLE
SEtup 1 (quIck) =
SEtup 2 (ASSIStED) =
SETUP
OPEN+CLOSE
OR
IMPORTANT! Test the good functioning of the installation before leaving the premises.
LONG PUSH (2 s)
SETTINGS
* Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
** The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should
always be smaller than 20 cm. The distance to the door leaf depends therefore on the thickness of the door leaf.
The size of the detection field varies according to the
mounting height and the settings of the sensor.
The full door width must be covered.
IMPORTANT! Step out of the detection field before launching a setup.
OR
STANDARD: inside installations
CRITICAL ENvIRONMENT: critical or outside installations
SHOPPING STREET: installations in narrow streets with pedestrian traffic
Mounting height
Detection width
2.00 m
2.20 m
2.50 m
3.00 m
3.50 m
2.00 m
2.20 m
2.50 m d max d max
Adjust the sensor by LCD or remote control (see p. 4 and 5) or choose one of the presettings:
Always verify the actual detection field width with a piece of paper and not the Spotfinder, which detects the whole emitted field.
3.50 m
3 m
2.50 m
2 m
d max = 2.5 m
3.50 m
3 m
2.50 m
2 m
LONG PUSH (4 s)
DOOR
OR
4
Pressing a parameter symbol on your remote control, displays the saved value directly on the LCD-screen.
HOW TO USE THE LCD?
To adjust contrast, push and turn the grey button simultaneously.
During normal function only.
PUSH
TO SELECT
PARAMETER
SCROLL
MENU
UP-DOWN
Select Back to return to previous menu or display.
Select More to go to next level:
- basic settings
- advanced settings
- diagnostics
Negative display = active output
displayed value = saved value
Select your language before entering the first LCD-menu.
During the first 30 seconds after power-on of the sensor or later in the diagnostics menu.
displayed value = factory value
CHANGING A vALUE
SCROLL VALUES
UP-DOWN
PUSH
TO SAVE
NEW VALUE
vALUE CHECK WITH REMOTE CONTROL
DISPLAY DURING NORMAL FUNCTIONING
FACTORY vALUE vS. SAvED vALUE
NAvIGATING IN MENUS
Scroll menu items
Push to enter the LCD-menu
new value is displayed
more values are displayed
current value is displayed
Opening impulse
Safety
1
1
off 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s
> > > > >
> > > >
>
1
2
A
B
> > >
+
0 1 2 3 4 5 6 7 8 9
5
radar
off
OvERvIEW OF SETTINGS
Back More
RAD: IMMUNITY
RAD: DIRECTION
RAD: HOLDTIME
AIR: WIDTH
AIR: NUMBER
AIR: PRESTIME
AIR: OUTPUT
REDIRECTION
FACTORYRST
DOOR BELL More
Back
Back More
PRESETTINGS
RAD: FIELDSIZE
RAD: OUTPUTAIR
IMMUNITY
AIR: FREQ
More Back
ZIP all parameter settings in zipped format ID # unique ID-number ERROR LOG the last 10 errors AIR: SPOTVIEW view of spot(s) that trigger detection AIR: C1 ENERG signal amplitude received on curtain 1 AIR: C2 ENERG signal amplitude received on curtain 2
POWER SU PPLY supply voltage at power connector OPERATINGTIME power duration since first startup RESET LOG delete all saved errors RC PASSWORD password for remotre control login LANGUAGE language of LCD-menu ADMIN enter code to access admin mode
standard
critical
env.
shopping
street
For conformity to EN 16005 or DIN 18650 at a mounting height of 2.8 or more, use values 6 and 7.
For conformity to BS 7036 at a mounting height of 2.2 m or more, use values 6 and 7.
Sensors mounted close to each other should have a different frequency.
increased immunities + 1 curtain increased immunities + redirection = motion and presence
factory values
small large
bi uni
uni
AWAY
low
0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s
uni
PRM
bi
auto
uni
auto
PRM
auto
PRM: for persons with reduced mobility AWAY: unidirectional motion away from sensor auto: automatic adaptation of field size (small shops)
service
mode
motion 15 s 30 s 1 min 2 min 5 min 10 min
motion
motion
or
presence
motion
and
presence
opening output is active in case of: 0 motion detection 1 motion or presence detection 2 motion and presence detection
20 min 60 min infinite
service mode = no IR detection during 15 minutes (maintenance). This value excludes conformity of the door system to EN 16005 and DIN 18650.
high
restore to factory values
min. value for DIN18650: 1 min min. value for EN16005: 30 s
IMPORTANT!
The auto mode of the detection direction is not allowed when the sensor is used in emergency exits.
BASICADVANCED
DIAGNOSTICS
freq: frequency output current: current output
NO: normally open
NC: normally closed
Always additionally adjust the arrow position on the sensor with a screwdriver.
excludes conformity to EN 16005 / DIN 18650 / BS 7036 of the door system
freq
NC
current
NC
NO
NC
NC
NC
NC
NO
NO
NO
freq
NC
current
NC
NO
NC
NC
NC
NC
NO
NO
NO
freq: frequency output current: current output
NO: normally open NC: normally closed
see application note DOOR BELL for more information
low
normal
highnormal
high
higher
highest
< 2.8 m > 2.8 m
2
1
4
6
7
5
1 2
1 2
1 2
1
1
1 2
1 2
1 2
1
1
1 2
1 2
1 2
1
1
1 2
1 2
2
2
6
8
9
2
1
1
E1
E2
E4
E5
E6
E7
E8
E9
TROUBLESHOOTING
The ORANGE LED flashes 1 x.
The ORANGE LED flashes 2 x.
The ORANGE LED flashes 4 x.
The ORANGE LED is on.
The RED LED flashes quickly after an assisted setup.
The RED LED lights up sporadically.
The GREEN LED lights up sporadically.
The LED and the LCD-display are off.
The reaction of the door does not correspond to the LED-signal.
The sensor signals an internal fault.
The power supply is too low or too high.
The sensor receives not enough AIR-energy.
The sensor encounters a memory problem.
The sensor vibrates.
The sensor sees the door during the assisted setup.
The sensor sees the door.
The sensor is disturbed by external conditions.
The sensor is disturbed by rain and/or leaves.
The sensor vibrates.
Ghosting created by door movement.
The sensor sees the door or other moving objects.
Check power supply
(in the diagnostics menu of the LCD).
Check wiring.
Check the angle of the AIR-curtains. Increase the AIR-immunity filter (values >2.8 m).
Cut and restore power supply. If orange LED lights up again, replace sensor.
Check the angle of the AIR-curtains. Launch a new assisted setup.
Attention: Do not stand in the detection field!
Check output configuration setting. Check wiring.
Check if the sensor is fastened firmly. Check position of cable and cover.
Increase the AIR-immunity filter to value 3. Select presetting 2 or 3.
Select presetting 2 or 3. Increase radar-immunity filter.
Change radar field angle.
Check if the sensor and door cover is fastened firmly. Check position of cable and cover.
Change radar field size or angle.
Remove the objects if possible.
Launch an assisted setup and adjust the AIR angle.
Cut and restore power supply. If orange LED flashes again, replace sensor.
The ORANGE LED flashes 6 x.
The ORANGE LED flashes 7 x.
The radar sensor output is faulty.
Replace sensor.
The internal test of the radar is disturbed.
Change radar field angle. If orange LED flashes again, replace sensor.
Cut and restore power supply. Check wiring.
The ORANGE LED flashes 5 x.
The sensor receives too much AIR-energy.
Check the angle of the AIR-curtains. Decrease the AIR-immunity filter (values 1-3 <2.8 m).
Motion detection
Presence detection
LED flashes
LED flashes quickly
LED is off
The ORANGE LED flashes 8 x.
The AIR power emitter is faulty.
Replace sensor.
The ORANGE LED flashes 9 x.
The internal reference of the radar is faulty.
Replace sensor.
7
INSTALLATION
The sensor should be fixed firmly to avoid extreme vibrations.
Do not cover the sensor.
Avoid moving objects and light sources in the detection field.
Avoid highly reflective objects in the infrared field.
It is recommended to clean the optical parts at least once a year or more if required due to environmental conditions.
Do not use aggressive products to clean the optical parts.
• The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer of the sensor.
• The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety.
• The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
Only trained and qualified personnel may install and setup the sensor.
The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel.
Always test the good functioning of the installation before leaving the premises.
The door control unit and the door cover profile must be correctly earthed.
MAINTENANCE
SAFETY
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | INFO@BEA.BE | WWW.BEA.BE
©BEA | Original instructions | 42.7874 / V1 - 0 6 .13
BEA hereby declares that the IXIO-DT3 is in conformity with the basic requirements and the other relevant provisions of the directives 1999/5/EC and 2006/42/EC. Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen EC-type examination certificate number: 44 205 12 405836-001 Angleur, June 2013 Pierre Gardier, authorized representative and responsible for technical documentation The complete declaration of conformity is available on our website: www.bea-pedestrian.be
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
TECHNICAL SPECIFICATIONS
Supply voltage: Power consumption: Mounting height: Temperature range: Degree of protection: Noise: Expected lifetime: Applicable directives:
Presence Typical response time: < 200 ms (max. 500 ms)
Active infrared with background analysis Spot: 5 cm x 5 cm (typ) Number of spots: max. 24 per curtain Number of curtains: 2
Solid-state-relay (potential and polarity free) Max. contact current: 100 mA Max. contact voltage: 42 V AC/DC Holdtime: 0.3 to 1 s
Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V) Response time on test request: typical: < 5 ms
EN 12978 EN ISO 13849-1:2008 PL «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
IEC 61496-1:2012 ESPE Type 2 EN 16005:2012 Chapter 4.6.8; DIN 18650-1:2010 Chapter 5.7.4 BS 7036-1:1996 Chapter 8.1
Motion Min. detection speed: 5 cm/s
Microwave doppler radar Transmitter frequency: 24.150 GHz Transmitter radiated power: < 20 dBm EIRP Transmitter power density: < 5 mW/cm
2
Solid-state-relay (potential and polarity free) Max. contact current: 100 mA Max. contact voltage: 42 V AC/DC
Frequency output: Pulsed signal (f= 100 Hz +/- 10%)
Current source output: Galvanically isolated current source No detection: current source ON Open circuit voltage: 6.5 V Output voltage available at 10 mA: 3 V min. Typical load: up to 3 optocouplers in series Detection: current source OFF Open-circuit remained voltage: < 500 mV
EN 12978 EN ISO 13849-1:2008 PL «d» CAT. 2 EN 16005:2012 Chapter 4.6.8; DIN 18650-1:2010 Chapter 5.7.4; AutSchR BS 7036-1:1996 Chapter 7.3.2
(only applicable for frequency and current source output)
Detection mode:
Technology:
Output:
Test input:
Norm conformity:
Specications are subject to changes without prior notice. All values measured in specific conditions.
12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10% (to be operated from SELV compatible power supplies only) < 2.5 W 2 m to 3.5 m
(local regulations may have an impact on the acceptable mounting height)
-25°C to +55°C; 0-95% relative humidity, non condensing IP54 < 70 dB 20 years R&TTE 1999/5/EC; MD 2006/42/EC; LVD 2006/95/EC; ROHS 2 2011/65/EU