“The Peak Of Detection”
COMBINED ACTIVE INFRARED / MICROWAVE AND ACTIVE INFRARED ONLY SENSOR
1 Description
- The IS40 uses Microwave technology
for activation and Active Infrared (IR)
technology for presence detection
- The IS40P uses Active IR technology for
presence detection only and the activation
relay can be triggered by entering or
exiting the IR fi eld
- Microwave Transceiver can be adjusted
30 degrees
- IR Presence area is 10’ x 10’ at 16’ high
- Operate on 12-24 VAC/DC +/- 10%
- Installation Height: 8’ to 16’
- Ceiling or Wall Mount
- Remote Control Accessible
2 Wiring / Setup
IS40 / IS40P
QUICK SETUP GUIDE
MICROWA VE ADJUSTMENT SCREW
MICROWAVE TRANSCEIVER
LED INDICATORS
IS40P
IS40
1 Sensor Wiring
LABEL
COLOR
POWER (VAC/DC) ACTIVATION RELAY PRESENCE RELAY
12-24 12-24 COM NO NC COM NO NC
RED BLACK WHITE GREEN YELLOW
2 Remote Control Parameters
FUNCTION
AUTOMATIC LEARN
TIME
IMMUNITY INFRARED
PATTERN INFRARED
AFFECTS
INFRARED OR
MICROWAVE
INFRARED
REMOTE
CONTROL
BUTTON
WHITE W/BLACK
STRIPE
FUNCTION DESCRIPTION
0: 30 seconds
1: 1 minute
2: 2 minutes
1: Low (Normal)
2: Medium (Rain)
3: High (Snow)
DOOR
1
6
DOOR DOOR DOOR DOOR
6
3: 5 minutes
4: 10 minutes
5: 20 minutes
DOOR DOOR DOOR DOOR
2
789
7
GREEN W/BLACK
6: 60 minutes
9: ∞(Infi nity)
3
8
STRIPE
4
9
YELLOW W/BLACK
STRIPE
5
FREQUENCY INFRARED
TARGET SIZE INFRARED
75.5376.01 EN 20080505 (75.5375) Page 1 of 2
F2
1: L - L’ Pulse Frequency
2: H - H’ Pulse Frequency
Defi ne the Minimum Size of Target
1 x 11:
5
2:
1 x 2
x 2
6
:
2 x
x 3
x 2
2 Remote Control Setup (Continued)
FUNCTION
INFRARED OR
MICROWAVE
SENSITIVITY MICROWAVE
DETECTION MODE MICROWAVE
REJECTION MODE MICROWAVE
AFFECTS
ACTIVATION
RELAY
HOLD TIME
RELAY
CONFIGURATION
OUTPUT
CONFIGURATION
DOOR EXAMPLE
LAST LINE
FIRST LINE
INFRARED
MICROWAVE
INFRARED
MICROWAVE
INFRARED
MICROWAVE
REMOTE
CONTROL
BUTTON
F1
FUNCTION DESCRIPTION
0-9: (7-Default)
1: Bidirectional (Towards or Away from Sensor)
2: Unidirectional Approach (Towards Sensor)
3: Unidirectional Depart (Away from Sensor)
Height = 16 ft.
Sensitivity 9, 6, 3
1: Detection of all Kind of Targets in Motion
2: Detection of all Kind of Targets in Motion + Interference Immunity
3: Low ‘Pedestrian/Parallel traffi c’ Rejection + Interference Immunity
6 3 0 3 6
FT.
3
6
9
S = 3
12
S = 6
15
S = 9
18
4: Medium ‘Pedestrian/Parallel traffi c’ Rejection + Interference Immunity
5: High ‘Pedestrian/Parallel traffi c’ Rejection + Interference Immunity
0: 0.5 second
1: 1.0 second
2: 2.0 seconds
4: 4.0 seconds
5: 5.0 seconds
6: 6.0 seconds
7: 7.0 seconds
8: 8.0 seconds
9: 9.0 seconds
3: 3.0 seconds
Activation
Relay
1 Active Passive
2 Passive Active
3 Passive Passive
4 Active Active
Presence
Relay
Description Active Passive
Detection
No Detection
COM COM
COM COM
NO
NC
NO
NC
NO
NC
NO
NC
PRESENCE RELAY IS40 IS40P
0 - 4: ALL MODES Activates when object is in
presence zone.
Activates when object
is in presence zone.
ACTIVATION RELAY IS40 IS40P
0: STANDARD MODE Activates when motion detected. Activates when object
1: PULSE ON ENTRY Activates if object motion is
detected and then object enters
presence zone.
2: PULSE ON EXIT Activates if object motion is
detected and then object exits
presence zone.
3: PULSE ON ENTRY
FIRST / LAST LINE
(See Example to the Left)
4: PULSE ON EXIT
FIRST / LAST LINE
(See Example to the Left)
Activates if object motion is
detected and then object enters
presence zone (fi rst or last line).
Activates if object motion is
detected and then object exits
presence zone (fi rst or last line).
is in presence zone.
Activates when object
enters presence zone.
Activates when object
exits presence zone.
Activates when object
enters presence zone
(fi rst or last line).
Activates when object
exits presence zone
(fi rst or last line).
SETUP
DEFAULT VALUES
INFRARED
MICROWAVE
INFRARED
MICROWAVE
Initiate Setup, press
Set Factory Defaults, press
3 Setup Sequence
1. Power on the sensor. Sensor automatically performs a Setup on power up and Setup is complete when Red/Green fl ashing stops.
2. If the Detection Zone (Background) permanently changes and a new Setup is required, perform a new Setup by pressing
. Red & Green LEDs will blink rapidly until setup is complete.
0
0
NOTE: Avoid movement in the IR zone during setup.
3 Company Contact
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please
call BEA, Inc. If you must wait for the following workday to call BEA., leave the door inoperable until satisfactory repairs
can be made. Never sacrifi ce the safe operation of the automatic door or gate for an incomplete solution. The following
numbers can be called 24 hours a day, 7 days a week. For more information, visit www.beasensors.com.
Page 2 of 2 75.5376.01 EN 20080505 (75.5375)
US and Canada:
Canada:
Northeast:
1-866-249-7937
1-866-836-1863
1-866-836-1863
Southeast:
Midwest:
West:
1-800-407-4545
1-888-308-8843
1-888-419-2564