BEA FALCON, FALCON XL User Manual

Page 1
TECHNICAL SPECIFICATIONS
DESCRIPTION OF THE SENSOR
FALCON & FALCON XL
USER'S GUIDE
MOTION SENSORS FOR INDUSTRIAL DOORS
FALCON: for high mounting FALCON XL: for low mounting
FALCON: from 11.5 to 23’ FALCON XL: from 6.5 to 11.5’
Tilt angle: 0° to 180° in elevation Detection zone (typical)
Wide pattern (FALCON XL): 13’ (W) x 6.5’ (D) for a mounting height of 8.2’ Narrow pattern (FALCON): 13’ (W) x 16’ (D) for a mounting height of 16’
Detection mode: movement Minimum detection speed: 2.2 in/s (measured in the
sensor axis) Supply voltage: 12V to 24V AC +/- 10% 12V to 24V DC +30% / -10%
Mains frequency: 50 to 60 Hz Power consumption: < 2W Output relay: free of potential changeover contact
Max contact voltage : 42V AC/ DC Max contact current: 1A (resistive) Max switching power: 30W (DC) / 60 VA (AC)
Hold time: 0.5s to 9s (adjustable) Manual adjustment:
orientation of sensing field (mechanically)
multiple functions (by push buttons).
Remote control adjustments:
Sensitivity.
Hold time.
Detection mode.
Pedestrian and parallel traffic rejection mode.
Relay configuration.
Temperature range : -22°F to 122°F (-30°C to +60°C) Degree of protection: IP65 Product conformity: R&TTE 1999/5/EC EMC 89/336/EEC Dimensions : 5 in (D) x 4 in (W) x 3 ¾ (H)
(127mm (D) x 102 mm (W) x 96mm (H))
Weight: 0.88 lbs (400 g) Housing Material: ABS and Polycarbonate Bracket Material: black anodized aluminum Cable length: 33 ft (10 m) Cable diameter: 1/8” (3 mm) (minimum)
1/4” (6.5 mm) (maximum)
INSTALLATION TIPS
The sensor must be firmly fastened in order not to vibrate.
The sensor must not be placed directly behind a panel or any kind of material.
The sensor must not have any object likely to move or vibrate in its sensing field.
The sensor must not have any fluorescent lighting in its sensing field.
75.5351.02 EN 20080317 (75.5350) Page 1 of 7
Page 2
p
y
WIRING
To remove or to insert the cable:
Unscrew the retaining nut;
Pass the cable through the grommet and the
US Wire Color: Red Black White Green Yellow 12-24 VAC/DC COM NO NC
ean Wire Color: Brown Green White Yellow Gra
Euro
OPENING AND CLOSING THE SENSOR
Opening the sensor Closing the sensor
retaining nut.
Tighten the retaining nut.
Loosen the retaining nut
until the cable slides easily into the
grommet;
Partially unscrew the 2 front cover screws;
Pull out the front cover with the 2 front cover screws.
Connect the quick disconnect terminal block to the main electronic circuit;
Slide the main electronic circuit into the 2 housing slot guides;
Gently push the front cover and make sure that the external housing is properly seated (front cover must be flush with housing).
Screw the 2 front cover screws and tighten the retaining nut.
SENSOR DIMENSIONS AND MOUNTING
BRACKET MOUNTING
Ceiling Mounting Wall Mounting
2.5 in
6 in
6.5 in
6 in
5.5 in
5 in
6.25 in
5 in
6.25 in
Remark: The bold-type values give the minimum distance required to be able to fully adjust the sensor.
Check that both locking collar are at the same angle;
Align the bracket slot to the locking collar guide as shown.
75.5351.02 EN 20080317 (75.5350) Page 2 of 7
3 in
Page 3
A
A
A
SETTING THE SENSING FIELD DIMENSIONS
The sensing fields here on the right correspond to the following adjustments:
tilt angle: 15°, 30°, 45°
sensitivity: 9.
The sensing fields here on the right correspond to the following adjustments:
tilt angle: 15°, 30°, 45° ;
sensitivity: 9.
6 3 0 3 6
3
6
9
12
15
18
21
H = 16.5 ft. S = 9
6 3 0 3 6
3
6
9
12
15
18
21
H = 11.5 ft. S = 9
FALCON (Mounting height: 16.5 feet)
3
6
9
12
15
18
21
The sensing fields here on the right correspond to the following adjustments:
tilt angle: 30°
sensitivity: 9, 6, 3
FALCON (Mounting height: 11.5 feet)
3
6
9
12
15
18
21
The sensing fields here on the right correspond to the following adjustments:
tilt angle: 30°
sensitivity: 9, 6, 3
6 3 0 3 6
2
5
8
1
H = 16.5 ft.
ngle = 30
°
6 3 0 3 6
3
6
9
12
H = 11.5 ft.
ngle = 30°
15
3
6
9
12
15
18
21
3
6
9
12
15
The sensing fields here on the right correspond to the following adjustments:
tilt angle: 15°, 30°, 45° ;
sensitivity: 9.
LED SIGNAL
When the power is turned ON, the red and green LEDs flash for few seco nds.
During a detection the red LED lights on.
During configuration, the red LED flashes a number of times corresponding to the paramete r being
changed (see next table). The green LED flashes a number corresponding to its setting.
6 3 0 3 6
3
6
9
12
H = 8 ft. S = 9
15
FALCON XL (Mounting height: 8 feet)
3
6
9
12
15
The sensing fields here on the right correspond to the following adjustments:
tilt angle: 30°
sensitivity: 9, 6, 3
3
6
9
12
15
6 3 0 3 6
H = 8 ft.
ngle = 30°
3
6
9
12
15
75.5351.02 EN 20080317 (75.5350) Page 3 of 7
Page 4
FUNCTIONS FUNCTIONS
CONFIGURATION CONFIGURATION
WITH REMOTE WITH REMOTE
CONTROL CONTROL
1. DESCRIPTION OF THE INFRARED REMOTE CONTROL
Open the battery compartment at the back of the remote control;
Insert two AAA batteries supplied with the remote control as shown beside;
Close the batteries compartment.
Remark: For optimum results point the remote control at the sensor before
pressing its buttons.
2. CO NFIGURATION OF THE SENSOR
Each setting change using the infrared remote control must start with an unlocking and end with a locking of the sensor. It is important to point out that any parameters changed using the remote control supersede any previous setting.
The table below lists all the parameters, which can be adjusted with the remote control as well as the operations, required to adjust them.
PARAMETER
KEY
UNLOCK
LOCK
Press the UNLOCK Key (3). Enter your four-digit access code using NUMBER Keys 0-9 (1).
During the first sensor adjustment or if the access code is reset to the ‘0000’ value (factory setting) or during the first minute after the power-on, press only the UNLOCK Key (3) (no code required).
UNLOCK with code UNLOCK without code
0-9 0-9 0-9 0-9
When all the parameters have been set, press the LOCK Key (10).
If you wish to enter a new access code, use NUMBER Keys 0-9 (1) to enter the new four-figure code within 20 seconds.
If no access code is entered or if you want to keep the current
USER'S ACTIONS FACTORY
SETTING
0000 The red LED flashes quickly waiting
0000 The red LED stops flashing to
LED SIGNAL
for the access code. After entering the correct code or if
no code is required, the red LED flashes slowly to indicate that the unlock is successful and the adjustment session has begun.
NOTE
: = Adjustment session ON
return to its normal function.
access code, press the LOCK Key (10) once more. If no remote control key is pressed within 1 minute, the
adjustment session is automatically locked. Pressing the LOCK Key (10) twice within the first minute after
the power-on reset automatically the access code to 0000 value.
LOCK with code change LOCK without code or Code change
0-9 0-9 0-9 0-9
75.5351.02 EN 20080317 (75.5350) Page 4 of 7
Page 5
During an adjustment session each parameter may be checked or changed at any time in the following way: PARAMETER
KEY
CHECK
VALUES
PLUS
MINUS
During a sensor adjustment session all the parameters may be reset to their factory values in the following w ay: PARAMETER
KEY
DEFAULT
VALUES
PARAMETER KEY USER'S ACTIONS FACTORY
SENSITIVITY
HOLD TIME
RELAY
CONFIGURATION
USER'S ACTIONS
Press the Key (5,6,7,8,11) corresponding to the parameter to be checked and then press the CHECK VALUES Key (9). Count the number of times the green LED flashes, which correspond to the value of the checked parameter. No green LED flash corresponds to the value 0. Repeat this operation to check the value of the other parameters if required. Example: SENSITIVITY Key (6) – 7 flashes of the green LED: the sensitivity is set at the value 7.
CHECK VALUES:
X
Press the Key (5 or 6) corresponding to the hold time or sensitivity parameter to be modified and then press the PLUS Key (2) to increase the value by 1 unit. PLUS:
X
Press the Key (5 or 6) corresponding to the hold time or sensitivity parameter to be modified. and then press the MINUS Key (4) to reduce the value by 1 unit.
MINUS:
X
USER'S ACTIONS
Press the DEFAULT VALUES Key (12), then press the NUMBER Key 1. All the parameters are reset to the factory values (see below). DEFAULTS VALUES:
1
LED SIGNAL
SETTING
Press the SENSITIVITY Key (6). Use the NUMBER Keys 0-9 (1) to enter the sensitivity required (or adjust this sensitivity using the PLUS (2) or MINUS (4) keys as explained above)
SENSITIVITY:
0-9
Press the HOLD TIME Key (5). Use the NUMBER Keys 0-9 (1) to enter the required hold time (0.5 s to 9 s) (or adjust this parameter using the PLUS (2) or MINUS (4) keys as explained above). HOLD TIME:
0-9
Press the RELAY CONFIGURATION Key (11). Use the NUMBER Keys 1-4 (1) to select the required relay configuration:
7
0.5 s
1
(Active
Output)
The red LED flashes quickly waiting for the value. Once this has been entered, it flashes slowly again.
The red LED flashes quickly waiting for the value. Once this has been entered, it flashes slowly again.
The red LED flashes quickly waiting for the value. Once this has been entered, it flashes slowly again.
75.5351.02 EN 20080317 (75.5350) Page 5 of 7
Page 6
DETECTION
MODE
REJECTION
MODE
Press the DETECTION MODE key (7). Use the NUMBER Keys 1-3 (1) to select the required mode: Key 1: bi-directional Key 2: unidirectional approach Key 3: unidirectional depart Detection mode:
1-3
Press the REJECTION MODE key (8). Immunity is used to avoid detection due to environmental interferences (vibrations, rains, etc). ‘Pedestrian/parallel traffic rejection’ provides both rejection of pedestrian and rejection of any parallel traffic at the same time.
2
(Unidirectional
Approach)
1
(No rejection)
The red LED flashes quickly waiting for the value. Once this has been entered, it flashes slowly again.
The red LED flashes quickly waiting for the value. Once this has been entered, it flashes slowly again.
Use the NUMBER keys 1- 5 (1) to enter the required rejection mode: key 1 : detection of all kind of targets in motion key 2 : detection of all kind of targets in motion + interference immunity key 3 : Low ‘Pedestrian/parallel traffic’ rejection + interference immunity key 4 : Mid ‘Pedestrian/parallel traffic’ rejection + interference immunity key 5 : High ‘Pedestrian/parallel traffic’ rejection + interference immunity
The discrimination between a pedestrian and the different vehicles depends mainly on the mounting height and the microwave module tilt angle. Be careful that the rejection function increases the response time of the sensor.
Use the next table as suggestions and do not hesitate to increase or decrease the rejection level to obtain the required rejection.
23 ft
16.5 ft
11.5 ft 10 ft
7.5 ft
FUNCTIONS CONFIGURATION WITH PUSH BUTTONS
Without remote control all of the parameters can be set using the 2 push buttons.
NOTE: These two buttons are accessible from the sensor front cover with a small point.
To adjust the sensor using the buttons: Press and hold either push button for 2 seconds (until the LEDs flash) and then release the button
To end adjusting the sensor using the buttons: Press and hold either push button for 2 seconds (until the LEDs stop flashing) and then release the button; NOTE
: If no button is pressed within 20 seconds the adjustment session is automatically ended.
To reset all the parameters to the factory values: Press and hold both push buttons simultaneously until the two LEDs switch on for 1 second (after 2 seconds).
During the manual adjustment session the red and green LEDs flash successively and c ontinuously.
The flashing number of the red LED provides the number of the displayed parameter (see next table);
The flashing number of the green LED provides the value of the displayed parameter;
: No red flashing indicates the zero value.
NOTE
75.5351.02 EN 20080317 (75.5350) Page 6 of 7
Page 7
During the manual adjustment session:
Each press on the right button increases the number of the displayed parameter by one unit;
Each press on the left button increases the value of the displayed parameter by one unit.
NOTE: When the maximum value or the highest number of the parameter is reached, this will return
to their minimum values.
Parameter
Number
1 Sensitivity 0 - 9 7 2 Hold time 0 - 9 0 3 Relay configuration 1 - 4 1 4 Detection mode 1 - 3 2 5 Pedestrian
For example, to change the sensitivity from 7 to 9 and the rejection mode from ‘detection of all kind of
targets in motion’ to High ‘Pedestrian/parallel traffic’ rejection.
Press any button for 2 seconds to enter the adjustment session and then release it.
The red LED flashes once (parameter 1 = sensitivity) and the green LED flashes 7 times (sensitivity=7).
Press the left button twice to increase the sensitivity from 7 to 9.
The red LED still flashes once (parameter 1 = sensitivity) but the green LED flashes 9 times now
(sensitivity=9).
Now press the right button 4 times to move to function 5 (rejection mode) ;
The red LED flashes 5 times (parameter 5 = rejection mode) and the green LED flashes once
(‘detection of all kind of targets in motion’) ;
Press the left button 4 times to set the parameter to High ‘Pedestrian/parallel traffic’ rejection.
The red LED still flashes 5 times (parameter 5 = rejection mode) but the green LED flashes 5 times now
(High ’Pedestrian/parallel traffic’ rejection).
Press any button during 2 seconds to end the adjustment session and then release it.
TROUBLE-
TROUBLE- SHOOTING
SHOOTING
SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION
The door will not open and the red LED does not light up. The door opens and closes constantly.
The sensor power is off. Check power supply. The sensor ‘sees’ the door
moving. When closing the door creates vibrations picked up by the sensor.
The door opens and closes after a given time for no apparent reason. The sensor is not capable of
The sensor is picking up unintended traffic motion.
The tilt angle is too large. Reduce the tilt angle. activation near the door. The sensor does not respond to the remote control.
The batteries are weak.
The access code has been
changed.
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call BEA, Inc. If you must wait for the following workday to call BEA, leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an incomplete solution.
The following numbers can be called 24 hours a day, 7 days a week. For more information, visit www.beasensors.com.
US & Canada: 1-866-249-7937 Midwest: 1-888-308-8843
Northeast: 1-866-836-1863 West: 1-888-419-2564
Southeast: 1-800-407-4545 Canada: 1-866-836-1863
Parameter Values Factory setting
rejection mode
1 - 5 1
Check the supply voltage. Increase the tilt angle and/or reduce the sensitivity. Ensure that the sensor is correctly fixed. If the rejection mode is set at level 1, set this parameter to level 2. Reduce the sensitivity. Switch to unidirectional mode. Reduce the sensitivity. Reduce the tilt angle.
Check the batteries insertion. Change the batteries.
Press both push buttons simultaneously to reset all the parameters to the factory values.
Or switch off the power supply. Within the first minute after the power on, change the access code.
75.5351.02 EN 20080317 (75.5350) Page 7 of 7