BEA FALCON, FALCON XL User Manual

TECHNICAL SPECIFICATIONS
DESCRIPTION OF THE SENSOR
FALCON & FALCON XL
USER'S GUIDE
MOTION SENSORS FOR INDUSTRIAL DOORS
FALCON: for high mounting FALCON XL: for low mounting
FALCON: from 11.5 to 23’ FALCON XL: from 6.5 to 11.5’
Tilt angle: 0° to 180° in elevation Detection zone (typical)
Wide pattern (FALCON XL): 13’ (W) x 6.5’ (D) for a mounting height of 8.2’ Narrow pattern (FALCON): 13’ (W) x 16’ (D) for a mounting height of 16’
Detection mode: movement Minimum detection speed: 2.2 in/s (measured in the
sensor axis) Supply voltage: 12V to 24V AC +/- 10% 12V to 24V DC +30% / -10%
Mains frequency: 50 to 60 Hz Power consumption: < 2W Output relay: free of potential changeover contact
Max contact voltage : 42V AC/ DC Max contact current: 1A (resistive) Max switching power: 30W (DC) / 60 VA (AC)
Hold time: 0.5s to 9s (adjustable) Manual adjustment:
orientation of sensing field (mechanically)
multiple functions (by push buttons).
Remote control adjustments:
Sensitivity.
Hold time.
Detection mode.
Pedestrian and parallel traffic rejection mode.
Relay configuration.
Temperature range : -22°F to 122°F (-30°C to +60°C) Degree of protection: IP65 Product conformity: R&TTE 1999/5/EC EMC 89/336/EEC Dimensions : 5 in (D) x 4 in (W) x 3 ¾ (H)
(127mm (D) x 102 mm (W) x 96mm (H))
Weight: 0.88 lbs (400 g) Housing Material: ABS and Polycarbonate Bracket Material: black anodized aluminum Cable length: 33 ft (10 m) Cable diameter: 1/8” (3 mm) (minimum)
1/4” (6.5 mm) (maximum)
INSTALLATION TIPS
The sensor must be firmly fastened in order not to vibrate.
The sensor must not be placed directly behind a panel or any kind of material.
The sensor must not have any object likely to move or vibrate in its sensing field.
The sensor must not have any fluorescent lighting in its sensing field.
75.5351.02 EN 20080317 (75.5350) Page 1 of 7
p
y
WIRING
To remove or to insert the cable:
Unscrew the retaining nut;
Pass the cable through the grommet and the
US Wire Color: Red Black White Green Yellow 12-24 VAC/DC COM NO NC
ean Wire Color: Brown Green White Yellow Gra
Euro
OPENING AND CLOSING THE SENSOR
Opening the sensor Closing the sensor
retaining nut.
Tighten the retaining nut.
Loosen the retaining nut
until the cable slides easily into the
grommet;
Partially unscrew the 2 front cover screws;
Pull out the front cover with the 2 front cover screws.
Connect the quick disconnect terminal block to the main electronic circuit;
Slide the main electronic circuit into the 2 housing slot guides;
Gently push the front cover and make sure that the external housing is properly seated (front cover must be flush with housing).
Screw the 2 front cover screws and tighten the retaining nut.
SENSOR DIMENSIONS AND MOUNTING
BRACKET MOUNTING
Ceiling Mounting Wall Mounting
2.5 in
6 in
6.5 in
6 in
5.5 in
5 in
6.25 in
5 in
6.25 in
Remark: The bold-type values give the minimum distance required to be able to fully adjust the sensor.
Check that both locking collar are at the same angle;
Align the bracket slot to the locking collar guide as shown.
75.5351.02 EN 20080317 (75.5350) Page 2 of 7
3 in
A
A
A
SETTING THE SENSING FIELD DIMENSIONS
The sensing fields here on the right correspond to the following adjustments:
tilt angle: 15°, 30°, 45°
sensitivity: 9.
The sensing fields here on the right correspond to the following adjustments:
tilt angle: 15°, 30°, 45° ;
sensitivity: 9.
6 3 0 3 6
3
6
9
12
15
18
21
H = 16.5 ft. S = 9
6 3 0 3 6
3
6
9
12
15
18
21
H = 11.5 ft. S = 9
FALCON (Mounting height: 16.5 feet)
3
6
9
12
15
18
21
The sensing fields here on the right correspond to the following adjustments:
tilt angle: 30°
sensitivity: 9, 6, 3
FALCON (Mounting height: 11.5 feet)
3
6
9
12
15
18
21
The sensing fields here on the right correspond to the following adjustments:
tilt angle: 30°
sensitivity: 9, 6, 3
6 3 0 3 6
2
5
8
1
H = 16.5 ft.
ngle = 30
°
6 3 0 3 6
3
6
9
12
H = 11.5 ft.
ngle = 30°
15
3
6
9
12
15
18
21
3
6
9
12
15
The sensing fields here on the right correspond to the following adjustments:
tilt angle: 15°, 30°, 45° ;
sensitivity: 9.
LED SIGNAL
When the power is turned ON, the red and green LEDs flash for few seco nds.
During a detection the red LED lights on.
During configuration, the red LED flashes a number of times corresponding to the paramete r being
changed (see next table). The green LED flashes a number corresponding to its setting.
6 3 0 3 6
3
6
9
12
H = 8 ft. S = 9
15
FALCON XL (Mounting height: 8 feet)
3
6
9
12
15
The sensing fields here on the right correspond to the following adjustments:
tilt angle: 30°
sensitivity: 9, 6, 3
3
6
9
12
15
6 3 0 3 6
H = 8 ft.
ngle = 30°
3
6
9
12
15
75.5351.02 EN 20080317 (75.5350) Page 3 of 7