BEA Falcon, Falcon XL, Falcon Wide Installation Manual

Page 1
75. 5835.0 4 FALCO N FAMILY 20160301 Page 1 of 4
FALCON
1
2
5
6
4
3
Specications are subjec t to change s without prior notice. * Other use of the devi ce is outside the permitted purpose and can not be guarantee d by the manufacturer.
** Measured in optimal conditions
DESCRIPTION
ENGLISH
Activation sensor for automatic industrial doors*
1. push buttons
2. front face
3. radar antenna
4. angle indication
5. bracket
6. cable
Technology: Transmitter frequency: Transmitter radiated power: Transmitter power density: Detection mode: Detection zone:
Min. detection speed: Supply voltage: Mains frequency: Max power consumption: Output: Max. contact voltage: Max. contact current: Max. switching power: LED-signal: Mounting height: Degree of protection: Temperature range: Dimensions: Tilt angles: Materials: Weight: Cable length: Norm conformity:
microwave doppler radar
24.150 GHz < 20 dBm EIRP < 5 mW/cm² motion FALCON: 13 x 16 ft @ 16ft ; FALCON XL: 13 x 6.5 ft @ 8.2ft; FALCON WIDE: 30 x 11 ft @ 21 ft. (typical at 30° and field size 9) 2 in/s** 12V to 24V AC ±10%; 12V to 24V DC +30% / -10% 50 to 60 Hz < 2 W relay (free of potential change -over contact) 42V AC/DC 1A (resistive) 30W (DC) / 60VA (AC) red: detection state, parameter indication; green: value indication FALCON: 11.5 - 23 ft; FALCON XL: 6.5 - 11.5 ft; FALCON WIDE: 11.5 - 21 ft IP65 from -22 °F to + 140 °F 5 in (L) x 4 in (H) x 3.75 in (W) 0° to 180° ver tical ABS and polycarbonate 14 oz 33 ft R&TTE 1999/5/EC; EMC 2004 /108/EC
FALCON: for normal to high mounting (11.5 - 23 ft) FALCON XL: for low mounting (6.5 - 11.5 ft) FALCON WIDE: for wide detection eld
For more information, please visit www.devancocanada.com or call toll free at 855-931-3334
Page 2
Page 2 of 4 75. 5835. 04 FALCON FA MILY 2016 0301
1
1
2 3
2
COM
NO
NC
12-24 V AC-DC
1
2
3
0-9
1-6
15° 30° 45° +45°
XL
Position the sensor on the bracket and fasten the screws firmly.
FALCON Mounting height: 16 ft
FALCON WIDE Mounting height: 11.5 ft
FALCON XL Mounting height: 8 ft
MOUNTING & WIRING
Adjust the angle of the sensor to position the detection field.
Remove the bracket from the sensor. Drill 2 holes accordingly. Mount the bracket firmly.
Connect the wires to the door controller. Choose between NO and NC contact.
DETECTION FIELD ADJUSTMENTS
DETECTION FILTER
(REJECTION MODE)
Adjust the field size with the remote control or the push buttons.
All detection field dimensions were measured in optimal conditions and with field size value 9.
CEILING
WALL
Choose the right detection filter for your application with the remote control or the push buttons:
Value recommendations according to angle and height:
Detection of all targets
(pedestrians and parallel traffic are detected)
1 = no specific filter
2 = filter against disturbances (recommended in case of vibrations, rain etc.)
Detection only of vehicles moving towards the sensor*
(pedestrians and parallel traffic are not detected + disturbances are filtered)
* The vehicle detection filter increases the response time of the sensor.
Always check if the chosen value is optimal for the application. The obje ct size and nature can inuence the detection.
RED
BLACK
WHITE
GREEN
YELLOW
23 ft - 11.5 ft 8 ft 3 3 4 4 5 4 6 5
Page 3
75. 5835.0 4 FALCO N FAMILY 20160301 Page 3 of 4
XXS XS S > > > > L XL XXL
0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s
3 4
5 6
1
2
P
A
(7)
(0)
(1)
(2)
(1)
POSSIBLE SETTINGS BY REMOTE CONTROL
FIELD SIZE
OUTPUT CONFIGURATION
A = active output (relay active when detection) P = passive output (relay active when no detection)
DETECTION MODE
uni
AWAY
FACTORY VALUES
RESET TING TO FACTORY VALUES:
Avoid proximity to neon lamps or moving objects.
Do not cover the sensor.
DETECTION FILTER
HOLD-OPEN TIME
Avoid vibrations. Only open the sensor
when the cable needs to be replaced.
Wall mounting
Ceiling mounting
Ceiling mounting
Bracket dimensions
Bracket dimensions
TO START OR END AN ADJUSTMENT SESSION, press and hold either push button until the LED flashes or stops flashing.
1 FIELD SIZE
Parameter n°
2 HOLD-OPEN TIME
3 OUTPUT CONFIGURATION
4 DETECTION MODE
5 DETECTION FILTER
Value (factory values)
TO SCROLL THROUGH THE PARAMETERS, press the right push button.
TO CHANGE THE VALUE OF THE CHOSEN PARAMETER, press the left push button.
TO RESET TO FACTORY VALUES, press and hold both push buttons until both LEDs flash.
POSSIBLE SETTINGS BY PUSH BUTTONS
MOUNTING TIPS
DIMENSIONS (inches)
bi = two-way detection uni = one-way detection towards sensor uni AWAY = one-way detection away from sensor
bi uni
Page 4
1
1 2 3 4 5
1 2
1 2
1
1 2 3
1
1 2 3 4
If you do not know the access code, cut and restore the power supply. During 1 minute, you can erase an unkown access code:
BEA hereby declares that the FALCON is in conformity with the basic requirements and the other relevant provisions of the directives 1999/5/EC and 2004/108/EC.
TROUBLESHOOTING
The sensor power is off.
Check the wiring and the power supply.
The complete declaration of conformity is available on our website: www.bea.be
The door opens and closes constantly.
The LED flashes quickly after unlocking.
The sensor does not respond to the remote control.
Improper output configuration on the sensor.
The sensor is disturbed by the door motion or vibrations caused by the door motion.
The sensor needs an access code to unlock.
The remote control batteries are weak or improperly installed.
Check the output configuration setting on each sensor connected to the door operator.
Check the batteries and change them if necessary.
Make sure the detection mode is unidirectional. Increase the detection filter value.
ACCESS CODE
SAVING AN ACCESS CODE:
DELETING AN ACCESS CODE:
The access code (1 to 4 digits) is recommended to set sensors installed close to each other.
The door remains closed. The LED is OFF.
The door does not react as expected.
Make sure the sensor is fixed properly. Make sure the detection mode is unidirectional. Increase the tilt angle. Increase the detection filter value. Reduce the field size.
Enter the right access code. If you do not know the access code, cut the power supply and restore it to access the sensor and change the access code or delete it.
Change the antenna angle. Decrease the field size. Increase the detection filter value.
The door opens for no apparent reason.
The sensor detects raindrops or vibrations.
In highly reflective environments, the sensor detects objects outside of its detection field.
Only for EC countries: According the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety. Only trained and qualified personnel may install and setup the sensor. The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
The vehicle detection filter is used, but pedestrians are still detected.
The chosen value is not optimal for this application.
Increase the detection filter value. Decrease the sensor angle. Increase the installation height. Make sure the detection mode is unidirectional.
ERASE AN UNKOWN ACCESS CODE:
Once you have saved an access code, you always need to enter this code to unlock the sensor.
For more information, please visit www.devancocanada.com or call toll free at 855-931-3334
Loading...