BEA ACTIV8 THREE PULSE User Manual

ACTIV8 THREE PULSE
1
2nd Radar Antenna
Radar motion
sensor
Radar Antenna clip
Radar tilt angle
indication
2
LED turns on LED flashing slowly LED flashing quickly Motion detection Presence detection
LED display during normal function
USER’S GUIDE
COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR FOR ESCAPE ROUTE DOORS
DESCRIPTION
Cover
Push Buttons
IR- sensor
IR-prism
Main Connector
45° 30° 15°
IR curtain adjustment
screw
SYMBOLS AND LED
x
See page x Factory value
x
GREEN LED Motion detection
RED LED Presence detection
ORANGE LED
3
Use the Remote Control to
adjust the sensor.
Avoid vibrations! Do not cover the sensor!
Troubleshooting
Use the Spotfinder to locate
the safety curtains.
Insert the prism
correctly into the guiding
Avoid moving objects in proximity to the sensor!
grooves!
Make sure the door
controller cover is fixed
properly and electrically
earthed.
Avoid HF lamps and
fluorescent lighting in the
infrared field!
INSTALLATION
Avoid touching electronic
and/or
optical parts!
Avoid highly reflective
objects in the infrared field!
7
ACTIV8 THREE PULSE 1/8
4
Mounting the sensor
1
1
Mount the sensor at a maximum height of 5 cm from the bottom line of the door controller.
Wiring the sensor
2
1
Use the mounting template to drill holes and position the sensor.
(Note:check that the door operator is compatible with this value)
R1 470
To ensure waterproof installation, place the cable as shown above.
Width of radar motion sensing field: choice of antenna
3
1
Sensitivity = 9
Depth of radar motion sensing field: tilt angle of radar-module
1
Sensitivity = 9
Touching the antenna patches will not cause any damage!
Sensitivity = 9
Sensitivity = 9
ACTIV8 THREE PULSE 2/8
f
f
Width of IR presence sensing field: choice of prism
5
1
2 curtains o
24 overlapping spots
(no gaps)
2 curtains o
12 overlapping spots
(no gaps)
Make sure to introduce the prism
into the guiding grooves
in front of the lenses and not into
If installed at a mounting height of 3 m or more, use the narrow
prism.
the cover!
Depth of IR presence sensing field: angle of IR-module (negative angle available)
6
1
Keep a minimum distance of 5cm between the door and first curtain.
To reduce the distance between curtain and door, turn the screw clockwise. To increase the distance, turn the screw counterclockwise. The pin indicates the angle.
When mounting one sensor on each side of the door above a highly reflective threshold, select different frequencies to avoid crosstalk between the sensors.
Use the Spotfinder to locate and adjust the position of the curtains.
5
ACTIV8 THREE PULSE 3/8
Remote control adjustments (only if factory values do not match)
7
Unlock the sensor to enter into adjustment session (see p.5 for info on the use of an access code)
To change the value of a parameter (ex. IR curtain immunity)
To change any other parameters (ex. Output Configuration)
To check the value of a parameter (ex. Max duration of presence detection)
Lock the adjustment session and go back to normal function
RED LED
flashes slowly
RED LED
flashes quickly
RED LED
flashes quickly
RED LED
flashes quickly
LED OFF
flashes slowly
flashes slowly
RED LED
RED LED
GREEN LED
Number of flashes = value of this parameter
RED LED
flashes slowly
6
7.1
Important remote control adjustments
1
UNLOCK
CHECK VALUES
LOCK
SENSITIVITY
0-9 0 (min) > 9 (max)
IR CURTAIN IMMUNITY
1 normal
2 increased 3 rain mode 4 snow mode 5 snow mode enhanced
NUMBER OF IR CURTAINS
1 1 curtain
(curtain closest to door)
2 2 curtains
nd
2
3 2
curtain in dynamic mode
MAX. DURATION OF PRESENCE DETECTION
0 30 seconds
1 1 minute
2 2 minutes 3 5 minutes 4 10 minutes
7
1
5 20 minutes 6 60 minutes
1
SETUP
launch setup launch assisted setup restore factory settings
ACTIV8 THREE PULSE 4/8
0
7.2
1
Launching a setup
Unlock the sensor to enter into adjustment session.
To launch an assisted setup Æ recommended after mechanical adjustments of the IR sensor
module.
Æ recommended once after the first installation
RED LED
flashes slowly
The sensor performs a door opening and closing
RED/GREEN
cycle to check the influence of the door leaves to the safety curtains. See Troubleshooting if RED
LED
LED flashes quickly after setup.
alternating
This setup is only effective if the relay output (opening) has been wired to the door controllers opening impulse input. This is required to create a door opening/closing cycle.
7.3
1
0 no redirection
1 transfer presence detection
0-9 0 (0.5s) > 9 (9s)
1 bidirectional mode
2 unidirectional mode
3 unidirectional mode with MTF
To launch a setup Æ recommended after change of parameters by remote control
LED display during sensor assisted setup
Setup process active:
RED/GREEN
LED
alternating
After finishing the setup process, the sensor shows the following behaviour:
RED LED flashing quickly The sensor ‘sees’ the door movement and can not finish its setup.
RED LED continuously on
ORANGE LED continuously on
No LED turns on The sensor successfully finished its setup.
Additional remote control adjustments
SAFETY OUTPUT REDIRECTION
to motion output
HOLD TIME
DETECTION MODE
2
RED/GREEN
The sensor only takes a new reference picture.
LED
alternating
The sensor signals a faulty IR monitoring.
The sensor encounters signal saturation (ex. due to highly reflective floor).
1
4-9 additional increased
2
7
7
INSTALLATION CONFIGURATION
MOUNTING HEIGHT
PULSE FREQUENCY
1 low low
2 high low 3 low high 4 high high
IMMUNITY
1 detection of quasi presence
2 normal
3 increased
immunities
ACTIV8 THREE PULSE 5/8
4
TÜV Requirements in Germany
High mounting height (>3m)
Rain/Snow
Reflective environments
Setup
Access Code
Overlapping IR-curtains
Only one single impulse input on door controller
Check the wiring
Push Buttons
INSTALLATION TIPS
To be TÜV compliant for the German market, please make sure to adjust the sensor as follows:
Number of IR curtains 2
Max. duration of presence detection 1 or higher (min. 1minute)
If the sensor is installed higher than 3m above the floor, make sure to use the narrow prism. In addition set the mounting height to “high mounting”:
If the sensor is exposed to rain or snow, use the URC (Universal Rain Cover). Set the sensor to presetting 3 or 4 to increase the immunity of the sensor. You can reduce the influence of rain and snow even more when selecting the RAIN or SNOW mode for the IR curtain immunity:
The additional increased radar immunity modes (4-9) reduce disturbances of the motion sensor in highly reflective environments (airlocks, curved and round sliding doors, metallic environments etc.).
After adjusting the sensor for the first time, it is recommended to launch an “assisted Setup”. If the IR sensor module “sees” the door movement, move the curtains out of the door leaves.
The access code is recommended to set sensors that are installed close to each other with remote control. If you forget the access code, you can still gain access to the sensor during the first minute after powering up (unlocking the sensor does not require entering an access code). You can program a new code or remove the code by entering LOCK 0000.
Overlapping IR-curtains from sensors installed side-by-side may cause disturbances due to crosstalk. Select different frequencies on each sensor to avoid crosstalk. Attention: avoid curtains that are overlapping by more than 30 cm (at 2,2m, using wide prism).
If your door controller has only one single impulse input for motion impulse (open the door) and no safety input (keep the door open), use the “Safety Output Redirection” to transfer the safety detection (IR sensor module) to the motion impulse output and connect only the motion output to your door controller. Note that the monitoring function is no longer active.
Push the left push button to release the outputs. The door should close and the LED should switch off.
For more information on the use of the push buttons, ask our quick reference guide “How to use push buttons”.
External Monitoring Enabled 1 (ON)
Sensitivity (size of detection field) Min. 1.5m depth
IR curtain immunity 1 to 3
Installation Configuration High Mounting Height
Installation Configuration High Mounting Height
RAIN mode
SNOW mode
SNOW mode enhanced
Additional increased immunities
Assisted Setup (~14sec)
Standard Setup (~4sec) Sensor only learns its environment
Safety Output Redirection Transfer presence detection to the motion output
Sensor checks the influence of the door leaves on the IR curtains (performs a door open/door close cycle)
Save an access code (between 1 and 4 digits)
Delete the access code (0 or 0000)
3+5
4
5
5
5
ACTIV8 THREE PULSE 6/8
5
SYMPTOMS
Red LED flashing quickly after an assisted setup.
POSSIBLE CAUSES
The sensor ‘sees’ the door movement and can not finish its setup.
CORRECTIVE ACTION
Adjust the position of the IR curtains.
TROUBLESHOOTING
3
Red LED permanently ON after an assisted setup.
The sensor fails the IR test. 1. Cut and restore the power supply.
2. Launch a new assisted setup. If the LED still stays ON, replace the sensor.
Red LED ON The sensor detects a presence. Wait as long as the time set in the “maximum duration of
presence detection” setting or launch an assisted setup (with the remote control or right push button).
Red LED ON The presence detection is disturbed by
Increase the immunity of the curtains (value 3 - 5)
the rain. Green LED ON
The radar detection is disturbed by the rain.
1. Check whether the unidirectional mode is selected and the MTF function is disabled.
2. Increase the radar immunity.
Orange LED flashes The sensor signals an internal fault. Cut and restore the power supply.
Orange LED ON The sensor encounters signal saturation. 1. Use the wide field prism and/or slightly increase the IR-
If the orange LED flashes again, replace faulty sensor.
curtains angle (turning the screw counterclockwise).
2. Launch an assisted setup. The door is not closing. LED OFF
1. On-Off switch at door control is in wrong position or is faulty.
Check to insure that On-Off switch for door is in ON or AUTOMATIC position.
2. Improper output configuration on the sensor. Check the output configuration setting on each sensor.
3. Faulty sensor monitoring of the door controller.
1. Check if the monitoring mode is ON or PULSE depending on the door controller.
2. Check the wiring.
3. Verify that ‘Door Control’ (F2) is set to ‘AUTO’.
The door closes slowly. LED OFF
Faulty sensor monitoring of the door controller. 1. Check if the monitoring mode is ON or PULSE
depending on the door controller.
2. Check the wiring.
3. Verify that ‘Door Control’ (F2) is set to ‘AUTO’.
After a power on, there is no LED-signal, even during a motion detection. The motion output is active and the presence output is fixed. Door keeps recycling open-closed. The sensor is disturbed by the door motion
The sensor’s monitoring input is not correctly supplied.
because it sees the door or feels vibrations.
Check the wiring and the power supply (voltage and polarity) of the monitoring input. Disable the monitoring of the sensor if the door controller cannot monitor the sensor. Green LED signals motion detection: Increase radar angle and radar immunity. Red LED signals infrared detection:
In airlock vestibules, the sensor sees the opposite door.
. Increase radar immunity.
Increase IR curtains angle (turning the screw counterclockwise).
5
4-5
4
5
3+5
4
3+5
3+5
3+5
2+3
In metallic environments, the sensor detects objects outside of its detection
Increase radar immunity.
field. Unwanted presence detection 1. The sensor is not placed properly. Fasten the sensor firmly.
2. The front face is not properly fixed. Check whether the front face prism is placed into
3
the guiding grooves and not in the sensor cover.
The sensor does not respond to the
remote control.
1. Batteries in the remote control are not installed properly or dead.
Verify whether the batteries are installed correctly or replace batteries.
2. Remote control badly pointed. Point the remote control towards the sensor.
The sensor does not unlock when access
code is entered.
Wrong code being entered. Cut and restore power supply. No code is required to
unlock during the first minute after powering.
6
Press on “unlock”, then on “lock” and introduce a new access code.
ACTIV8 THREE PULSE 7/8
6
TECHNICAL SPECIFICATIONS
Supply voltage : 12V (– 5%) to 24V (+10%) AC/DC Mains frequency : 50 - 60 Hz Power consumption : < 3 W Mounting height : 1.8m to 4m 3-coloured LED : RED (presence detection) - GREEN (motion detection) - ORANGE (signal saturation, error) Temperature range : -25°C to +55°C Degree of protection : IP54 Norm conformity : R&TTE 1999/5/EC; EMC 89/336/EEC Dimensions : 262 mm (L) x 55 mm (H) x 44 mm (D) Weight : 250 g Housing material : ABS + LURAN S Minimum length of cable Range of Remote Control : 5m
: ± 2.6 m
MOTION SENSOR PRESENCE SENSOR
Detection mode Motion
Minimum detection speed: 5 cm/s (measured in sensor axis)
Technology Microwave and microprocessor
Transmitter frequency: 24.175 GHz Transmitter radiated power: < 20 dBm EIRP Transmitter power density: < 5 mW/cm²
Detection field
Width Depth Wide 4 m 2 m Narrow 2 m 2,5 m
Angle
From 15° to 50° in elevation (adjustable) From - 4° to + 4° (adjustable)
Output specification Free of potential current source
State “No detection”: current source ON
Max. open circuit voltage: 6.5V Output voltage available at 10mA: 3V min. Typical load: up to 3 optocouplers in series
State “Detection”: current source OFF
Leakage current: <100µA Open-circuit remained voltage: <500mV
Input specification
Output holdtime
0.5s to 9s (adjustable) 0,1/1s (fixed)
7
Presence Typical response time: < 128 ms (max. 500 ms) Focused active infrared and self-monitored microprocessor Spot diameter (standard): 0.1m max Number of spots: 24 or 12 spots by curtain Number of curtains: 2
Width Depth Wide 2 m 0,35 m Narrow 1 m 0,35 m
Transistor (NPN open collector) requiring ext. pull-up resistor
Max. output current: 25 mA Max. switching power: 40 V DC Max. pulse amplitude (detection state or fail state): 0,8V
Input Impedance: 100k Max. input voltage: 30 V DC External pull-up resistor: 470Ω* Min. Pulse amplitude (Vpp): > 50% of sensor supply voltage Max. Pulse duration: 100µs @ 25mA output current Min. time interval between pulses: > pulse duration
*check that the door controller is compatible with this value
Sensing field dimensions given at 2.2m mounting height.
Specifications are subject to changes without prior notice.
ACCESSORIES
Remote Control Spotfinder ACA ABA
42.0184 / V4 – 11.05
Liege Science Park Allée des Noisetiers, 5 • 4031 Angleur Belgium • TEL +32 (0)4 3616565 • FAX +32 (0)4 3612858 • e-mail: info@bea.be www.beasensors.com
ACTIV8 THREE PULSE 8/8
Antenna narrow field Antenna wide field Prism 1 m Prism 2 m