LED-SIGNALS
- 11.1
V
.7114
instructions
ina
ri
BEA
The ORANGE LED
fl ashes every second.
The ORANGE LED
fl ashes 1 x.
1
The ORANGE LED
fl ashes 2 x.
2
The ORANGE LED
fl ashes 4 x.
4
The ORANGE LED
fl ashes 5 x.
5
The ORANGE LED
is on.
The RED LED fl ashes
quickly after an
assisted setup.
The RED LED
The sensor goes into
security mode.
The sensor signals
an internal fault.
Irregularities in the
power supply
The sensor receives
not enough IR-energy.
The sensor receives
too much IR-energy.
The sensor encounters
a memory problem.
The sensor sees the door
during the assisted setup.
The sensor vibrates.
lights up
sporadically.
The sensor sees the door.
The sensor is disturbed by
lamps or another sensor.
The sensor is disturbed
by the rain.
The GREEN LED
lights up
sporadically.
The sensor is disturbed by
rain and/or leaves.
Ghosting
The sensor vibrates.
The sensor sees the door
or other moving objects.
The LED is off.
The reaction of
the door does not
correspond to the
LED-signal.
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery
directive 2006/42/EC.
Only trained and qualifi ed personnel may install and setup the sensor.
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
Avoid touching any electronic and optical components.
BEA hereby declares that the ACTIV8 ONE ON is in conformity with the basic requirements and the other
relevant provisions of the directives 1999/5/EC, 2004/108/EC and 2006/42/EC.
Notifi ed Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
Angleur, November 2010 Jean-Pierre Valkenberg, Authorized representative
The complete declaration of conformity is available on our website: www.bea.be
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | INFO@BEA.BE | WWW.BEA.BE
1
Cut and restore power supply.
Cut and restore power supply.
1
If orange LED fl ashes again, replace sensor.
2
1
Check power supply.
Check wiring.
2
Use the 1 m prism if possible.
1
Check the angle of the IR-curtains.
2
Use a low energy prism if possible.
1
Check the angle of the IR-curtains.
2
Cut and restore power supply.
1
If orange LED lights up again, replace sensor.
2
1
Check the angle of the IR-curtains.
Launch a new assisted setup.
2
Attention: Do not stand in the detection fi eld!
Check if the sensor is fastened fi rmly.
1
Check position of prism and cover.
2
1
Launch an assisted setup and adjust the IR angle.
1
Choose a different frequency by remote control.
1
Increase the IR-immunity fi lter to value 2 or 3.
2
Select presetting 2 or 3 by push button.
Select presetting 2 or 3 by push button.
1
Increase radar-immunity fi lter by remote control.
2
Change radar antenna angle.
1
1
Check if the sensor is fastened fi rmly.
2
Check position of cable and cover.
Remove the objects if possible.
1
Change radar antenna.
2
Change radar fi eld size (sensitivity).
3
Check connections to test output.
1
If your door controller is not able to test the sensor,
2
connect the red and blue cable to power supply.*
Check output confi guration setting.
1
Switch value 1 (A-P) to 4 (A-A) or 4 to 1 by
2
remote control.
*excludes DIN18650-conformity of the door system
Please keep fo r further use
Designed for colour printing
R
E
I
U
Z
N
I
G
F
I
T
N
R
A
E
C
Z
T
B
U
A
L
R
E
DIN 18650
E
N
A
B
L
E
C
S
C
A
Other use of the device is outside the permitted purpose
H
and can not be guaranteed by the manufacturer.
H
The manufacturer cannot be held responsible for incorrect
T
I
W
installations or inappropriate adjustments of the sensor.
E
C
N
A
D
R
O
DESCRIPTION
4
3
2
1
TECHNICAL SPECIFICATIONS
Supply voltage:
Power consumption:
Mounting height:
Sensitivity of the test input:
Temperature range:
Degree of protection:
Expected lifetime:
Norm conformity:
Detection mode:
Technology:
Angle:
Output:
Hold time output signal:
Response time on test request:
1. IR-prism (2 m)
2. radar antenna (wide fi eld)
3. radar antenna (narrow fi eld)
4. cover
12 V - 24 V AC +/-10% ; 12 V - 30 V DC -5%/+10%
< 3 W
1.8 m to 4 m
< 1 V : Log. L; > 10 V: Log. H (max. 30 V)
-25 °C to +55 °C
IP54
5 years
R&TTE 1999/5/EC; EMC 2004/108/EC; MD 2006/42/EC; EN 12978
EN ISO 13849-1:2008 Performance Level «c» CAT. 2
(under the cond ition that the door control system monitors the sens or at least once per doo r cycle)
Motion
Min. detection speed: 5 cm/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm2
From 15 ° to 50 ° vertical (adjustable)
Relay (free of potential)
Max. contact voltage: 42 V AC/DC
Max. contact current: 1 A (resistive)
Max. switching power: 30 W (DC)/60 VA (AC)
0.5 s to 9 s (adjustable)
5. push buttons
6. IR-curtain ajustment screw
7. main connector
(< 3 m to enable DIN 18650-confor mity)
GREEN
LED
ACTIV8 ONE ON
Opening & safety sensor
for automatic sliding doors
5
6
7
(to be operated from SELV compatible power supplies only)
RED
LED
Presence
Typical response time: <128 ms (max. 500 ms)
Active infrared with background analysis
Spot diameter: 0.1 m (typ)
Number of spots: 24 or 12 by curtain
Number of curtains: 2
From -4 ° to +4 ° (adjustable)
Solid-state-relay
(free of potential, free of polarity)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
0.3 s to 1 s (not adjustable)
Typical: < 15 ms (max. 25 ms)
pecifi cations ar e subject to chan ges without prior not ice.
All values measured in optimal conditions.
ENGLISH
For product version 0600 and more

MOUNTING & WIRING
1
max 5 cm
The door control unit and the door cover profi le must be correctly earthed.
12-24 V
AC-DC
*
*
* Output status when sensor is operational
** For compliance with DIN 18650, connection
GREEN
BROWN
YELLOW
WHITE
SENSOR
PINK
GREY
RED**
BLUE**
to door controller test output is required.
ACTIV8 ONE ON
POWER SUPPLY
OPENING INPUT
OPENS DOOR
SAFETY INPUT
KEEPS DOOR OPEN
TEST
OUTPUT
SETTINGS (by push buttons and/or remote control)
4
RADAR FIELD SIZE
(SENSITIVITY)
PRESETTINGS
-
0
1
2
3
3x GREEN LED
3
XXS, XS, S ...
SHORT PUSH LEFT:
3
2
1
0
1
2
- 1 VALUE
STANDARD
PUSH LEFT
(KEEP PUSHED)
CRITICAL ENVIRONMENT
SHOPPING STREET
+
0
1
2
3
1
2
3
FLASH OF DESIRED
...
L, XL, XXL
2
1
0
RELEASE AFTER
SETTING
SHORT PUSH RIGHT:
3
+ 1 VALUE
ACTIV8 ONE ON
RED-GREEN
OFF
PRESETTING
SELECTED
RADAR FIELD - OPENING IMPULSE
2
WIDTH
0
1
2
3
2
3
2.2 m
0
9
1
2
3
2
1
0
1
3
4 m x 2 m
The width of the radar fi eld varies according to the mounting height of the sensor.
INFRARED FIELD - SAFETY
3
W
1
2 m
H
2
1
0
H W
2.20 m 2.35 m
2.50 m 2.50 m
3.00 m 2.70 m
Max. mounting height: 3 m
WIDTHANGLE
0
1
2
Detection fi eld width indicated according to conditions defi ned in D IN 18650 and including dimension of test body CA.
2
3
3
3
0
2
1
2
3
2.2 m
1
0
1
2 m x 2.5 m
W
1
2
3
1 m
9
3
2
H
1
0
H W
2.20 m 1.35 m
2.50 m 1.50 m
3.00 m 1.70 m
ANGLE
2
Max. mounting height: 4 m
(>3 m excludes DIN18650-conformity)
2.2 m
«click»
GREEN
LED
RED
LED
RESETTING TO
FACTORY VALUES
FIELD SIZE (SENSITIVITY)
IMMUNITY FILTER
DETECTION MODE
HOLD TIME
OUTPUT SIGNAL
(MONITORING)
TEST
OUTPUT
CONFIGURATION
OUTPUT
REDIRECTION
NUMBER OF
CURTAINS
IMMUNITY FILTER*
PULSE FREQUENCY
MAX. PRESENCE
TIME
>
RED-GREEN
OR
PUSH
LEFT + RIGHT
1
XXS XS S > > > > L XL XXL
>>>>>
low
bi uni
0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s
off
on auto
A-P
P-A P-P
motion
motion
motion
service
mode
30
s 1 min 2 min 5 min 10 min 20 min 60 min
and
or
presence
presence
12
normal
medium high
freq A freq A+ freq B+
FACTORY VALUES
>
highnormal
uni
PRM
auto = the sensor will automatically adapt to the door controller:
opening output is active in case of: 0 motion detection
1 motion or presence detection
2 motion and presence detection
dynamic
mode
freq B
bi = two-way detection; uni = one-way detection towards sensor;
uni
uni PRM = for persons with reduced mobility; uni AWAY = away from sensor
AWAY
when the door controller monitors the sensor > on
when the door controller does not monitor the sensor > off (excludes DIN18650-conformity)
A = active output (NO-contact)
A-A
P = passive output (NC-contact)
service mode = no detection is active during 15 minutes (maintenance).
dynamic mode = 2nd curtain is only active during motion detection.
>>>>
immunity 3 is only suitable if a combined
sensor is on each side of the door
excludes DIN18650-conformity of the door system
Opening
Safety
L= 3.20 m x 1.40 m
(at 2.2 m)
Check position of
max.
DOOR
5 cm
TIP: Launch an ASSISTED SETUP to verify wiring, position of the curtains and correct functioning of the sensor.
It is recommended to clean the optical parts at least once a year or more often if required due to environmental conditions.
IR-curtains with
Spotfi nder and
adjust if necessary.
ORANGE
CLOSER
AWAY
SETUP (step out of the detection fi eld during setup)
5
QUICK SETUP =
RED-GREEN
OFF
ASSISTED SETUP =
>
PUSH RIGHT UNTIL
RED-GREEN
FLASHES
OPEN+CLOSE
OR
+
RED-GREEN
OFF
IMPORTANT: Test the good functioning of the installation before leaving the premises.
* In immunit y 2 and 3, the standard detec tion capability is the same as in immunity 1 (factory setting). Environmental and installation conditions can
affect the detection capability of the sensor or can impact the availability of the door system. During harsh conditions, the sensor can temporarily
adapt the detection capabilit y to ensure the availability of the door system.