BEA 1SAFE User Manual

Page 1
1/4
1SAFE
1/4
Do not cover the
sensor.
Avoid high intensity
lightning in the detection field.
Avoid reflective
background or objects
in the detection field
of the sensor.
Do not touch the
optical parts.
FLICKERS
FLASHES
SLOWLY
ON
OFF
RED LED is ON during detection
ORANGE LED flashes 1X after power on
Emitter
Receiver
Cable with connector
Fixation screw
Setup adjustment screw
LED
DIP-switch
Push button
Front face
INSTALLATION TIPS
LED-SIGNAL
DESCRIPTION
USER’S GUIDE
ACTIVE INFRARED SAFETY SENSOR FOR AUTOMATIC DOORS
Page 2
1
4
2
5
6
3
7
8
8
MOUNTING TEMPLATE
110
50
30
1
2
+4
0
-4
2/4
GREEN
OR
RED
Use the mounting template to cut out the opening for the sensor.
Unclips the front face by inserting a screwdriver as shown.
Push the push button shortly to launch an automatic setup. The LED will flash RED-GREEN.
When the LED turns OFF the sensor is correctly installed. Fasten the front face and test the good functioning of the sensor.
If the LED continues flashing, you have to adjust the sensor further (see SETUP next page).
Connect the cable and insert the sensor into the opening.
After inserting the sensor, fix the 2 screws firmly.
The sensor can also be installed on the surface by using the surface mount accessory (sold seperately).
Adapt the angle of the sensor.
INSTALLATION
OFF
RED-GREEN
NORMALLY OPEN
ACTIVE LOGIC
YELLOW-BLACK
NO POWER
NO DETECTION
DETECTION
NORMALLY CLOSED
PASSIVE LOGIC YELLOW-WHITE
BROWN
Power supply 12-24V AC/DC
COM NC NO
Monitoring
GREEN
YELLOW
WHITE
RED
BLACK
BLUE
Page 3
ADDITIONAL ADJUSTMENTS
1
2
3
4
+
OK
+
-
F1
F1
F2
F2
ON
DIP
1
2 3 4
ON
DIP
1
2 3 4
ON
DIP
1
2 3 4
ON
DIP
1
2 3 4
ON
DIP
1
2 3 4
ON
DIP
1
2 3 4
ON
DIP
1
2 3 4
3/4
ON
DIP
1
2 3 4
ON
DIP
1
2 3 4
ON
SETUP
Frequency 2
Monitoring Active Low
UNCOVERED
ZONE
FREQUENCY
MONIT
ORING
OFF
(Factory values)
ADDITIONAL ADJUSTMENTS
Automatic mode
Manual mode
Frequency 1
Monitoring Active High
Do not touch the screw. It should be positioned as shown.
Push the push button shortly to launch an automatic setup.
LED flashes RED-GREEN.
Switch to manual mode
How? Decrease (-) or increase (+) the uncovered zone and check it by moving a white paper up and down under the sensor.
When? When 2 or more sensors are installed in proximity to each other, it is recommended to choose different frequencies to avoid crosstalk.
When? When 2 or more sensors are installed in proximity to each other, it is recommended to choose different frequencies to avoid crosstalk.
When? When the monitoring input mode is active high or when no monitoring is required.
When? When the monitoring input mode is active low.
Big (40cm at 2.2m)
When? When increased immunity to disturbances is required.
Relaunch a setup after changing dip switch 2
Small (25cm at 2.2m)
When? When increased door safety is required.
Relaunch a setup after changing dip switch 2
When?
- low reflectivity of background
- no background or > 3mmounting height
- mounting height < 1.6m
- uncovered zone > 40cm
GREEN
RED
4x ORANGE
RED-GREEN
OFF
When the application requires specific adjustments, you can adapt the sensor by using the dip switches.
Do not move the white paper horizontally!
Page 4
BEA SA - LIEGE Science Park - Allée des Noisetiers 5 - B-4031 Angleur - T +32 4 3616565 - F +32 4 3612858 - info@bea.be - www.bea.be
4/4
active infrared
presence detection by distance measurement
35mm x 70mm (at 2.2m mounting height)
64ms
0.6m - 3m
12V - 24V AC/DC -5% / + 10%
50 - 60 Hz
120mA @ 24V AC / 80mA @ 24V DC
relay (free of potential contact)
42V AC/DC
1A (resistive)
30W (DC) / 60VA (AC)
0.5s
min. 10% at IR-wavelength of 850nm
-25°C - +55°C; 0-95% rel. humidity, non condensing
IP53
Electromagnetic compatibility (EMC) according to
144mm (L) x 40mm (H) x 50mm (D)
ABS (black)
2.5m
2004/108/EC
Technology:
Detection mode:
Detection field:
Response time:
Mounting height:
Supply voltage:
Mains frequency:
Max. current consumption:
Standard output:
Max. contact voltage:
Max. contact current:
Max. switching power:
Hold time:
Reflectivity:
Temperature range:
Degree of protection:
Norm conformity:
Dimensions:
Housing material:
Length of main cable:
Specifications are subject to changes without prior notice
42.0608 - V3 / 01.13
TROUBLESHOOTING
RED
OFF
RED
RED
4x ORANGE
Launch setup and check adjustment.
Bad adjustment of the uncovered zone.
The monitoring mode is wrong.
Launch a manual setup.
Change the position of DIP 4.
Check wiring: connect RED and BLUE to monitoring output.
If the door control has no monitoring: do not connect RED and BLUE wires.
Launch a manual setup.
Launch a manual setup.
Launch a new setup.
The signal received from background is too weak.
The distance to the floor has changed due to external factors.
The sensors interfere with each other due to overlapping detection zones.
You are standing inside the detection field.
Step outside the detection field.
Check if the sensor is installed correctly.
Range is too short.
The signal received from background is too weak.
Increase the distance between the sensors or select a different frequency on each sensor.
Check if proximate modules have different frequencies.
Increase the uncovered zone.
The sensor detects eratically.
The red LED is permanently ON.
The LED is OFF, but the relay “clicks”.
The red LED flickers.
The orange LED flashes 4x during setup.
The red LED flashes during setup.
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE ACTION
TECHNICAL SPECIFICATIONS
The wiring is not correct.
1 optocoupler (free of potential contact)
30V
High state: >10V
Low state: <1V
Monitoring input:
Max. contact voltage:
Voltage threshold:
The colour version of this user's guide and other technical documentation are available on our website (www.bea.be) or can be requested by phone (+32 4 361 65 65) or mail (info@bea.be).