Baxi Platinum Combi 24 HE A, Platinum Combi 28 HE A, Platinum Combi 33 HE A, Platinum Combi 40 HE A User Operating Instructions Manual

© Baxi Heating UK Ltd 2009
Platinum Combi HE A Range
Gas Fired Wall Mounted Condensing
Combination Boiler
User’s Operating Instructions &
Important Warranty Information
Please keep these instructions in a safe place.
2
© Baxi Heating UK Ltd 2009
© Baxi Heating UK Ltd 2009 All rights reserved. No part of this publication may
be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 1988.
Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address:
The Company Secretary, Baxi Heating UK Ltd, The Wyvern Business Park, Stanier Way, Derby, DE21 6BF.
Full acknowledgement of author and source must be given.
WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages.
1.0 Quick Reference Guide 3
2.0 Troubleshooting 4
3.0 Repressurising System 6
4.0 Clearances 7
5.0 Care of the Boiler 8
6.0 Legislation 9
7.0 Setting the Timer 10
8.0 Emergency 11
9.0 Warranty & Service 12
Section Page
Contents
Boiler Controls - see opposite page
for Operating Quick Reference Guide
Natural Gas
Baxi Platinum Combi 24 HE A
G.C.No47 075 31
Baxi Platinum Combi 28 HE A
G.C.No47 075 32
Baxi Platinum Combi 33 HE A
G.C.No47 075 33
Baxi Platinum Combi 40 HE A
G.C.No47 075 34
This product has an energy rating (A) on a scale of A to G.
For more information see www.boilers.org.uk. This is a certification mark.
0086
ISO 9001
FM 00866
The Benchmark Scheme
Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk
1.0 Quick Reference Guide
3
© Baxi Heating UK Ltd 2009
bar
0
1
2
3
4
1
2
3
4
5
PM
7
8
9
10
11
12
1
2
3
4
5
AM
7
8
9
10
11
12
GRASSLIN
0
bar
0
1
2
3
4
ON/OFF/Reset Selector Switch
Display Central Heating
Temperature Control
Domestic Hot Water Temperature Control
System Pressure Gauge
OFF Position
The boiler will not operate.
Central Heating Temperature Control
Turn the knob clockwise to increase or anticlockwise to decrease the temperature. Range 25 - 80° C.
Domestic Hot Water Temperature Control
Turn the knob clockwise to increase or anticlockwise to decrease the temperature.
Central Heating Indicator - The indicator will illuminate when the boiler is in the central heating mode.
Domestic Hot Water Indicator - The indicator will illuminate when hot water is being supplied to a tap or shower.
Burner On Indicator - The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water.
Boiler Output Temperature - In either the central heating or domestic hot water position the display will illuminate showing the current boiler temperature in degrees centigrade.
Central Heating System Pressure - The normal operating water pressure is between 1 and
2.0 bar. If the pressure exceeds 3 bar the safety pressure valve will operate and a fault is indicated. Contact your Installer.
Central Heating & Hot Water
Both Heating & Hot Water will operate.
Reset
Hold for approx 5 seconds and release.
Display
IntegralTimer
2.0 Troubleshooting
4
© Baxi Heating UK Ltd 2009
START
Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker).
If no gas, consult your supplier.
Is the ON/OFF/Reset Select Switch in the ( ) position ?
Is the ( ) or ( ) light on and the ( ) on ?
Check electricity to the boiler is switched on.
Is the display lit ?
Display
Central Heating Indicator
Domestic Hot Water Indicator
Burner On Indicator
Boiler operating satisfactorily.
bar
0
1
2
3
4
Is the Central Heating System Pressure between 1 and 2.5 bar ?
If the reading falls below 1 bar repressurise the system as described in section 3.1.
Does the display show an error code e.g. E133, E110 ?
Boiler not working
NO
NO
YES YES
YES
NO
Turn the ON/OFF/Reset Selector Switch to Reset.
Error Code E119 showing low pressure.
NO
YES
YES
NO
If boiler does not Reset
Loading...