Installers are required to carry out installation, commissioning and
servicing work in accordance with the Benchmark Code of Practice
which is available from the Heating and Hotwater Industry Council who
manage and promote the Scheme. Visit www.centralheating.co.uk for
more information.
The Company Secretary, Baxi Heating UK Limited, Brooks House, Coventry Road, Warwick. CV34 4LL
Full acknowledgement of author and source must be given.
WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for
damages.
You have just purchased one of our appliances and we thank you for the trust you have placed in our products. Please note that
the product will provide good service for a longer period of time if it is regularly checked and maintained. Our customer support
network is at your disposal at all times.
2EcoBlue Advance Combi7219715 - 03 (04/17)
Installer Notification Guidelines
Installer Notification Guidelines
Choose Building
Regulations Notification
Route
Competent Person's
Self Certification Scheme
Install and Commission this
appliance to manufacturer's
instructions
Complete the
Benchmark Checklist
If you notify via the ‘Gas Safe
Register’, the register will issue
the Building Regulations
certificate on members’ behalf
Building Control
Contact your relevant Local
Authority Building Control
(LABC) who will arrange
an inspection or contact
a government approved
inspector
Install and Commission this
appliance to manufacturer's
This boiler can be used by children aged 8 years and
above and by persons with reduced physical, sensory
or mental capabilities or lack of experience and
knowledge when they have been given supervision or
instruction concerning the safe use of the device and
understand the resulting risks. Children must not be
allowed to play with the appliance. Cleaning and user
maintenance must not be carried out by children
without supervision.
WARNING
Installation, repair and maintenance must only be
carried out only by a competent person. This
document is intended for use by competent persons.
All Gas Safe registered engineers carry an ID card with their
licence number and a photograph. You can check your engineer
is registered by telephoning 0800 408 5500 or online at
www.gassaferegister.co.uk
This appliance must be installed in accordance with the
manufacturer’s instructions and the regulations in force. If the
appliance is sold or transferred, or if the owner moves leaving
the appliance behind you should ensure that the manual is kept
with the appliance for consultation by the new owner and their
installer. Read the instructions fully before installing or using the
appliance.
In GB, this must be carried out by a competent person as stated
in the Gas Safety (Installation & Use) Regulations (as may be
amended from time to time).
Definition of competence: A person who works for a Gas Safe
registered company and holding current certificates in the
relevant ACS modules, is deemed competent.
In IE, this must be carried out by a competent person as stated
in I.S. 813 “Domestic Gas Installations”.
The addition of anything that may interfere with the normal
operation of the appliance without express written permission
from the manufacturer or his agent could invalidate the
appliance warranty. In GB this could also infringe the Gas Safety
(Installation and Use) Regulations.
The appliance is designed as a boiler for use in residential
domestic environments on a governed meter supply only. The
selection of this boiler is entirely at the owner’s risk. If the
appliance is used for purposes other than or in excess of these
specifications, the manufacturer will not accept any liability for
resulting loss, damage or injury.
The manufacturer will not accept any liability whatsoever
for loss, damage or injury arising as a result of failure to
observe the instructions for use, maintenance and
installation of the appliance.
WARNING
Check the information on the data plate is
compatible with local supply conditions.
1.2Additional Documentation
These Installation & Service Instructions must be read in
conjunction with the Flue Installation Guide supplied in the
Literature Pack.
Various timers, external controls, etc. are available as optional
extras. Full details are contained in the relevant sales literature.
7219715 - 03 (04/17)EcoBlue Advance Combi7
1Introduction
1.3Symbols Used
In these instructions, various levels are employed to draw the
user's attention to particular information. In so doing, we wish to
safeguard the user's safety, prevent hazards and guarantee
correct operation of the appliance. Each level is accompanied by
a warning triangle
DANGER
Risk of a dangerous situation causing serious
physical injury.
WARNING
Risk of a dangerous situation causing slight physical
injury.
CAUTION
Risk of material damage.
Signals important information .
Signals a referral to other instructions or other pages
in the instructions.
1.4Abbreviations
DHW: Domestic hot water
CH: Central heating
GB: Great Britain
IE: Ireland
BS: British standard
HHIC: Heating and Hotwater Industry Council
Pn: Nominal output
Pnc: Condensing output
Qn: Nominal heat input
Qnw: Nominal domestic hot water heat input
Hs: Gross calorific value
8EcoBlue Advance Combi7219715 - 03 (04/17)
Introduction1
1.5Extent of Liabilities
1.5.1 Manufacturer's Liability
Our products are manufactured in compliance with the
requirements of the various european applicable Directives.
They are therefore delivered with marking and all relevant
documentation. In the interest of customers, we are
continuously endeavouring to make improvements in product
quality. All the specifications stated in this document are
therefore subject to change without notice.
The manufacturer will not accept any liability for loss, damage or
injury arising as a result of:-
Failure to abide by the instructions on using the appliance.
Failure to regularly maintain the appliance, or faulty or
inadequate maintenance of the appliance.
Failure to abide by the instructions on installing the
appliance.
This company declares that no substances harmful to
health are contained in the appliance or used during
appliance manufacture.
The appliance is suitable only for installation in GB and IE and
should be installed in accordance with the rules in force, and
only used in a suitably ventilated location.
In GB, the installation must be carried out by a Gas Safe
Registered Installer. It must be carried out in accordance with
the current and relevant requirements of legislation and
guidance including the:-
• Gas Safety (Installation & Use) Regulations.
• The appropriate Building Regulations either The
Building Regulations, The Building Regulations
(Scotland), Building Regulations (Northern Ireland).
• The Water Fittings Regulations or Water Byelaws in
Scotland.
• The Current I.E.E. Wiring Regulations.
Where no specific instructions are given, reference should be
made to the relevant British Standard Code of Practice.
In IE, the installation must be carried out by a competent person
and installed in accordance with the current edition of I.S. 813
‘Domestic Gas Installations’, the current Building Regulations
and reference should be made to the current ETCI rules for
electrical installation.
Prior to commissioning all systems must be thoroughly
flushed and treated with inhibitor (see section 5.2.6). Failure
to do so will invalidate the appliance warranty.
Incorrect installation could invalidate the warranty and may lead
to prosecution.
7219715 - 03 (04/17)EcoBlue Advance Combi9
1Introduction
1.5.2 Installer's Responsibility
The installer is responsible for the installation and initial start up
of the appliance. The installer must adhere to the following
instructions:
Read and follow the instructions given in the manuals
provided with the appliance.
Carry out installation in compliance with the prevailing
legislation and standards.
Ensure the system is flushed and inhibitor added.
Install the flue/chimney system correctly ensuring it is
operational and complies with prevailing legislation and
standards, regardless of location of the boiler’s installation.
Only the installer should perform the initial start up and carry
out any checks necessary.
Explain the installation to the user.
Complete the Benchmark Commissioning Checklist - this is a
condition of the warranty !
Warn the user of the obligation to check the appliance and
maintain it in good working order.
Give all the instruction manuals to the user.
1.6Homologations
1.6.1 CE Marking
EC - Declaration of Conformity
Baxi Heating UK Limited being the manufacturer / distributor
within the European Economic Area of the following:-
Baxi EcoBlue Advance 24 - 28 - 33 - 40 Combi ErPD
declare that the above is in conformity with the provisions of the
Council Directive
and has been subject to the following conformity procedures laid
down in
Annex 2 - Article 3 of 2009/142/EC
under the supervision of the British Standards Institution, a
Notified Body authorized by the United Kingdom Competent
Authority, and carrying the Notified Body Number 0086.
Type test for purpose of Regulation 5 certified by:
Notified Body 0085.
Product/Production certified by:
Notified Body 0086.
For GB/IE only.
10EcoBlue Advance Combi7219715 - 03 (04/17)
Introduction1
1.6.2 Standards
Codes of Practice - refer to the most recent version
In GB the following Codes of Practice apply:
Standard Scope
BS 6891 Gas Installation.
BS 5546 Installation of hot water supplies for domestic
purposes.
BS EN 12828 Heating systems in buildings.
BS EN 12831 Heating systems in buildings - Calculation of
load.
BS EN 14336 Installation & commissioning of water based
heating systems.
BS 6798 Installation of gas fired hot water boilers.
BS 5440 Part 1Flues.
BS 5440 Part 2Ventilation.
BS 7074 Expansion vessels and ancillary equipment for
sealed water systems.
BS 7593 Treatment of water in domestic hot water
central heating systems.
BS 4814 Specification for Expansion Vessels using an
internal diaphragm, for sealed hot water
systems.
IGE/UP/7/1998Guide for gas installations in timber framed
housing.
In IE the following Codes of Practice apply:
Standard Scope
I.S. 813 Domestic Gas Installations.
The following standards give valuable additional information;
BS 5546 Installation of hot water supplies for domestic
purposes.
BS EN 12828 Heating systems in buildings.
BS EN 12831 Heating systems in buildings - Calculation of
load.
BS EN 14336 Installation & commissioning of water based
heating systems.
BS 7074 Expansion vessels and ancillary equipment for
sealed water systems.
BS 7593 Treatment of water in domestic hot water
central heating systems.
7219715 - 03 (04/17)EcoBlue Advance Combi11
2Safety
2Safety
2.1General Safety Instructions
DANGER
If you smell gas:
1. Turn off the gas supply at the meter
2. Open windows and doors in the hazardous area
3. Do not operate light switches
4. Do not operate any electrical equipment
5. Do not use a telephone in the hazardous area
6. Extinguish any naked flame and do not smoke
7. Warn any other occupants and vacate the
premises
8. Telephone the National Gas Emergency Service
on:- 0800 111 999
2.2Recommendations
WARNING
Installation, repair and maintenance must be carried
out by a Gas Safe Registered Engineer
(in accordance with prevailing local and national
regulations).
When working on the boiler, always disconnect the
boiler from the mains and close the main gas inlet
valve.
After maintenance or repair work, check the
installation to ensure that there are no leaks.
CAUTION
The boiler should be protected from frost.
Only remove the casing for maintenance and repair
operations. Replace the casing after maintenance
and repair operations.
12EcoBlue Advance Combi7219715 - 03 (04/17)
Safety2
2.3Specific Safety Instructions
2.3.1 Handling
General
• The following advice should be adhered to, from when first
handling the boiler to the final stages of installation, and
also during maintenance.
• Most injuries as a result of inappropriate handling and lifting
are to the back, but all other parts of the body are
vulnerable, particularly shoulders, arms and hands. Health
& Safety is the responsibility of EVERYONE.
• There is no ‘safe’ limit for one man - each person has
different capabilities. The boiler should be handled and lifted
by TWO PEOPLE.
• Do not handle or lift unless you feel physically able.
• Wear appropriate Personal Protection Equipment
e.g. protective gloves, safety footwear etc.
Preparation
• Co-ordinate movements - know where, and when, you are
both going.
• Minimise the number of times needed to move the boiler plan ahead.
• Always ensure when handling or lifting the route is clear
and unobstructed. If possible avoid steps, wet or slippery
surfaces, unlit areas etc. and take special care on
ladders/into lofts.
Technique
• When handling or lifting always use safe techniques - keep
your back straight, bend your knees. Don’t twist - move your
feet, avoid bending forwards and sideways and keep the
load as close to your body as possible.
• Where possible transport the boiler using a sack truck or
other suitable trolley.
• Always grip the boiler firmly, and before lifting feel where the
weight is concentrated to establish the centre of gravity,
repositioning yourself as necessary. See the ‘Installation’
section of these instructions for recommended lift points.
Remember
• The circumstances of each installation are different. Always
assess the risks associated with handling and lifting
according to the individual conditions.
• If at any time when installing the boiler you feel that you
may have injured yourself STOP !! DO NOT ‘work through’
the pain - you may cause further injury.
IF IN ANY DOUBT DO NOT HANDLE OR LIFT THE BOILER OBTAIN ADVICE OR ASSISTANCE BEFORE PROCEEDING !
7219715 - 03 (04/17)EcoBlue Advance Combi13
3Technical Specifications
3Technical Specifications
3.1Technical Data
Appliance Type C
13 C33 C53
Appliance Category CAT I
2H
Heat Input CH Qn Hs (Gross)
Max Min
24 model kW 22.2 5.2
28 model kW 26.6 6.3
33 model kW 31.1 7.6
40 model kW 35.5 8.9
Heat Output CH Pn (Non-Condensing)
Max Min
24 model kW 20.0 4.6
28 model kW 24.0 5.5
33 model kW 28.0 6.6
40 model kW 32.0 7.8
Heat Output CH Pnc (Condensing)
Max Min
24 model kW 21.2 4.9
28 model kW 25.3 6.0
33 model kW 29.6 7.1
40 model kW 33.9 8.4
Heat Input DHW Qnw Hs (Gross)
Max
24 model kW 27.4
28 model kW 32.1
33 model kW 37.8
40 model kW 45.8
Heat Output DHW
Max
24 model kW 24.0
28 model kW 28.0
33 model kW 33.0
40 model kW 40.0
Gas Nozzle Injector
24 model mm Ø 5.0
28 model mm Ø 5.6
33 model mm Ø 6.6
40 model mm Ø 6.6
Above Casing 175 mm Min
Below Casing 150 mm* Min
Front 450 mm Min
(For Servicing)
Front 5 mm Min (In Operation)
L.H. Side 5 mm Min
R.H. Side 5 mm Min
*This is MINIMUM recommended dimension.
Greater clearance will aid installation and
maintenance.
NOTE: All data in this section are nominal
values and subject to normal production
tolerances.
Pump
Available Head See graph below
Pump - Available Head
6
5.5
5
4.5
4
3.5
3
2.5
2
Metre (wg)
1.5
1
0.5
0
200 400 600 800 1000 1200
0
Flow Rate (l/h)
Central Heating Primary Circuit
Pressures
bar
Safety Discharge 3
Max Operating 2.5
Min Operating 0.5
Recommended Operating Range 1-2
DHW Circuit bar
Pressures
Max Operating 8
Min Operating 0.15
Flow Rates (24) (28) (33) (40)
l/min l/min l/min l/min
DHW Flow Rate
o
@ 30
C Rise 10.9 12.9 15.3 18.3
DHW Flow Rate
o
@ 35
C Rise 9.8 11.5 13.5 16.4
Min Working
DHW Flow Rate 2 2 2 2
Where Low Flow Taps or Fittings are intended to
be used in the DHW system connected to a Baxi
EcoBlue Advance Combi it is strongly
recommended that the DHW flow rate DOES
NOT fall below 2.5 l/min. This will ensure
reliable operation of the DHW function.
Expansion Vessel - (For Central Heating
only. Integral with appliance)
bar
Min Pre-charge Pressure 1.0
(24 & 28) (33 & 40)
litre litre
Max Capacity of
CH System 125 155
Primary Water Content
of Boiler (unpressurised) 2.5 2.5
NATURAL GAS ONLY !
Max Gas Rate (Natural Gas - G20)
(After 10 mins)
24 model m
28 model m
33 model m
40 model m
Dynamic (nominal) Inlet Pressure
(Natural Gas - G20)
mbar 20
with a CV of 37.78 MJ/m
Product Characteristics Database
SAP 2009 Annual Efficiency is
This value is used in the UK Government’s
Standard Assessment Procedure (SAP) for energy
rating of dwellings. The test data from which it has
been calculated has been certified by 0085 .
3
/h 2.61
3
/h 3.05
3
/h 3.59
3
/h 4.35
3
(SEDBUK)
89%
14EcoBlue Advance Combi7219715 - 03 (04/17)
Technical Specifications3
See
3.2Technical Parameters
Technical parameters for boiler combination heaters
Baxi EcoBlue Advance Combi ErPD
Condensing boiler
Low-temperature boiler
(1)
B1 boiler
Cogeneration space heater
Combination heater
Rated heat output
Useful heat output at rated heat output
and high temperature regime
(2)
Useful heat output at 30% of rated heat
output and low temperature regime
(1)
Seasonal space heating energy efficiency
Useful efficiency at rated heat output and
high temperature regime
(2)
Useful efficiency at 30% of rated heat
output and low temperature regime
(1)
Auxiliary electricity consumption
Full load
Part load
Standby mode
Other items
Standbyheat loss
Ignitionburnerpowerconsumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxidesNO
Prated
P
4
P
1
Š
s
Š
4
Š
1
kW
kW
kW
%
%
%
elmax
elmin
P
SB
kW
kW
kW
P
stby
P
ign
Q
HE
kW
kW
kWh
GJ
L
WA
X
dB
mg/kWh
24
YesYesYesYes
NoNoNoNo
NoNoNoNo
NoNoNoNo
YesYesYesYes
20242832
20.024.028.032.0
6.78.09.410.7
93939393
88.087.988.087.9
98.098.098.198.0
0.0300.0350.0400.040
0.0140.0140.0140.014
0.0030.0030.0030.003
0.0350.0350.0400.045
----
17204206452408627527
62748799
51525355
22202424
Domestic hot water parameters
Declared load profile
Daily electricity consumption
Annual electricity consumption
Water heating energy efficiency
Daily fuel consumption
Annual fuel consumption
(1) Low temperature means for condensing boilers 30°C, for low temperature boilers 37°C and for other heaters 50°C
return temperature (at heater inlet).
(2) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
Q
elec
AEC
Š
wh
Q
fuel
AFC
kWh
kWh
%
kWh
GJ
XLXLXXLXXL
0.1510.1680.2150.172
33374738
90888685
21.34021.98027.85028
16172223
2833
40
.570
S
The back cover for contact details.
7219715 - 03 (04/17)EcoBlue Advance Combi15
3Technical Specifications
There must be no part of the air duct
(white tube) visible outside the property.
3.3Dimensions and Connections
Dimensions
At least 1.5°
E
G
A 763mm
B 345mm
C 450mm
A
D 116mm Ø Min.
E 160mm
(207mm for 80/125mm
flue systems)
F 140mm
B
360° Orientation
G 106mm
H 170mm
H
J 280mm
D
C
J
50 mm
F
Condensate
45 mm
Drain
Flue Ø 100mm
Tap Rail
65 mm65 mm65 mm65 mm
Heating
Flow
(22mm)
Hot Water
Outlet
(15mm)
Gas
Inlet
(22mm)
Cold Water
(15mm)
Inlet
Pressure
(15mm)
Heating
Return
(22mm)
Relief
Valve
95 mm
30
16EcoBlue Advance Combi7219715 - 03 (04/17)
M2
Low Voltage
External Control
Connection
10
Technical Specifications3
3.4Electrical Diagram
1
2
3
4
5
6
7
8
9
w
Boiler
br
Controls
r
bk
R
/P
++
/R
Sensor
M1
Mains Voltage
Connection
1
2
Link
y
g/y
b
E
N
br
L
Mains Input Cable
Hall Effect
Sensor
Flue
bk
Heating
Return
Sensor
Heating
Flow
Sensor
b
b
r
g
Hydraulic
Pressure
Switch
br
b
bk
b
r
w
b
b
r
r
g/y
b
g/y
g/y
p
y
X20X21X30
X50
b
X10 X11X12 X13X14
br
bk
b
br
g
br
g
Fan
DHW
NTC
Sensor
g
b
bk
b
b
r
w
bk
Safety
Thermostat
Diverter
Valve
Motor
X42X41X40
X60
X23X22
X1 X2
g/y
b
b
br
br
br
Pump
b
Igniter
br
b
bk
g
Spark
Ignition
Electrode
b
br
g
bk
g/y
Flame
Sensing
Electrode
g/y
Gas
Valve
Timer Connector
1
2345
b
br
Timer Bridge
Key To Wiring Colours
b- Blue
r- Red
bk- Black
br- Brown
w- White
gr- Grey
7219715 - 03 (04/17)EcoBlue Advance Combi17
g- Green
g/y - Green/Yellow
y- Yellow
p- Purple
4Description of the Product
4Description of the Product
Information
Label
4.1General Description
1. The Baxi EcoBlue Advance Combi boilers are fully automatic
gas fired wall mounted condensing combination boilers. They
are room sealed and fan assisted, and will serve central heating
and mains fed domestic hot water.
2. The boiler is set to give a maximum output of :-
24 model - 24 kW DHW
21.2 kW CH Pnc (Condensing)
28 model - 28 kW DHW
25.3 kW CH Pnc (Condensing)
33 model - 33 kW DHW
29.6 kW CH Pnc (Condensing)
40 model - 40 kW DHW
33.8 kW CH Pnc (Condensing)
3. The boiler is factory set for use on Natural Gas (G20).
Boiler Control
Flap
Fig. 1
4. The boiler is suitable for use only on fully pumped sealed
heating systems. Priority is given to domestic hot water.
5. The boiler data badge gives details of the model, serial
number and Gas Council number and is situated on the boiler
lower panel. It is visible when the control box is lowered (Fig. 2).
6. The boiler model, serial number and Gas Council number are
also shown on the information label behind the boiler control flap
(Fig. 1). This is for user reference.
7. The boiler is intended to be installed in residential/domestic
environments on a governed meter supply only.
8. The boiler must be installed with one of the purpose designed
flues such as one of the standard horizontal telescopic flue kits
detailed in the Flue Installation Guide .
All systems must be thoroughly cleansed, flushed and
treated with inhibitor (see section 5.2.6).
These Installation & Servicing Instructions MUST be
read in conjunction with the Flue Installation Guide supplied in
the Literature Pack.
Data Badge
Fig. 2
Control Box
removed for clarity
18EcoBlue Advance Combi7219715 - 03 (04/17)
Description of the Product4
14
13
12
22
15
16
23
17
24
18
19
20
21
4.2Operating Principle
The boiler can be set in 3 operating modes:- ‘Summer’
(DHW only), ‘Winter’ (CH & DHW) or ‘Heating Only’ (CH only) by
use of the button.
4.2.1 Central Heating Mode
1. With a demand for heating, the pump circulates water through
the primary circuit.
2. Once the burner ignites the fan speed controls the gas rate to
maintain the heating temperature measured by the temperature
sensor.
3. When the flow temperature exceeds the setting temperature,
a 3 minute delay occurs before the burner relights automatically
(anti-cycling). The pump continues to run during this period.
4. When the demand is satisfied the burner is extinguished and
the pump continues to run for a period of 3 minutes (pump
overrun).
4.2.2 Domestic Hot Water Mode
11
10
3
7
8
9
A
B
C
6
D
Boiler Schematic
Layout
Key
1. Pump with Automatic Air Vent
2. Boiler Drain Tap
3. Pressure Gauge
4. Safety Pressure Relief Valve
5. DHW Flow Sensor/Filter/Restrictor
6. Domestic Hot Water Priority Sensor
(‘Hall Effect’ Sensor)
7. Domestic Hot Water NTC Sensor
8. Hydraulic Pressure Switch
9. Three Way Valve & Motor
10. Plate Heat Exchanger
11. Gas Valve
Connections:A – Condensate Drain
B – Heating Flow
C – Domestic Hot Water Outlet
D – Gas Inlet
E – Cold Water Inlet On/Off Valve and filter
F – Heating Return
1
2
5
4
E
12. Safety Thermostat (105° C)
13. Heating Flow Sensor
14. Flue Sensor
15. Boiler Adaptor
16. Primary Heat Exchanger
17. Spark Ignition Electrode
18. Burner
19. Flame Sensing Electrode
20. Air/Gas Collector
21. Heating Return Sensor
22. Fan
23. Air/Gas Venturi
24. Expansion Vessel
F
1. Priority is given to the domestic hot water supply. A demand
at a tap or shower will override any central heating requirement.
2. The flow of water will operate the DHW Sensor (Hall Effect
Sensor) which requests the 3 way valve to change position. This
will allow the pump to circulate the primary water through the
DHW plate heat exchanger.
3. The burner will light automatically and the temperature of the
domestic hot water is controlled by the temperature sensor.
4. When the domestic hot water demand ceases the burner will
extinguish and the diverter valve will remain in the domestic hot
water mode, unless there is a demand for central heating.
4.2.3 Boiler Frost Protection Mode
1. The frost protection mode is integral to the appliance and
functions as long as there is power to the boiler, as indicated by
the standby signal .
2. With CH & DHW or CH only selected, when the boiler
temperature falls below 5°C the boiler will fire until a
temperature of 30°C is reached.
3. If DHW only is selected, when the boiler CH temperature falls
below 5°C the boiler will fire until a temperature of 30°C is
reached. When the boiler DHW temperature falls below 5°C the
boiler will fire until a temperature of 7°C is reached.
4. Further protection can be incorporated by using a system
frost thermostat.
4.2.4 Pump Protection
1. This activates once a week if there has been no demand. The
pump runs for 30 seconds to prevent sticking.
7219715 - 03 (04/17)EcoBlue Advance Combi19
4Description of the Product
EV1
1 2 3 4
ADJ.
4.3Main Components
20
23
19
11
10
12
2
3
1. Expansion Vessel
1
9
2. Expansion Vessel Valve -
Do NOT use as vent
3. Primary Heat Exchanger
4. Plate Heat Exchanger
5. Pump with Automatic Air Vent
6. Central Heating System Pressure Gauge
7. Fan Assembly with Venturi
8. Air/Gas Collector
9. Flue Se nsor
10. Flame Sensing Electrode
11. Spark Ignition Electrode
12. Combustion Box Cover & Burner
13. Control Box Display
8
14. Condensate Trap
15. Safety Pressure Relief Valve
24
16. Drain Off Point
17. Gas Valve
18. Diverter Valve Motor
7
19. Boiler Controls
20. Boiler Adaptor
21. Heating Flow Sensor
22. Safety Thermostat
23. Igniter
24. Air Box
4
5
13
6
21
25. Heating Return Sensor
26. Hydraulic Pressure Sensor
27.
Domestic Hot Water Priority Sensor
(‘Hall Effect’ Sensor)
25
22
18
14
RQRQADJ.
16
5
16
26
1 2 3 4
EV1
17
27
20EcoBlue Advance Combi7219715 - 03 (04/17)
Description of the Product4
R
4.4Control Panel Description
Key to Controls
Boiler Information View
Domestic Hot Water (DHW)
Temperature Adjustment
Summer - Winter - Heating Only
Standby - Reset - Esc
/P
++
R
/R
Central Heating (CH)
Temperature Adjustment
Mode
Standby - Reset - Esc Button
R
Boiler Information View Button
Increase CH Temperature Button
Decrease CH Temperature Button
Increase DHW Temperature Button
Decrease DHW Temperature Button
Summer / Winter / Only Heating Mode Button
Summer - DHW only mode
Winter - DHW & CH mode
Heating Only - Only CH mode
R
Display showing all available characters
Display Description
DHW and CH OFF (frost protection still enabled)
Indicate errors that prevent burner from igniting
Error - Not resettable by user
Water pressure too low
Indicates an error resettable by the user
R
Indicates navigation in programming mode (parameter)
Indicates navigation in programming mode
Generic error
Burner lit
DHW mode (symbol will flash with demand)
Heating mode (symbol will flash with demand)
Units for temperature
Units for pressure
Service due
7219715 - 03 (04/17)EcoBlue Advance Combi21
4Description of the Product
4.5Standard Delivery
1. The pack contains:
Boiler
Wall mounting plate (pre-plumbing jig) including
isolation valves
Fittings pack
Literature pack
• Installation & Servicing Manual
(including ‘benchmark’)
• User Guide Instructions
• Flue Accessories & Fitting Guide
• Registration Card
• Fernox Leaflet
• Adey Leaflet
• Wall Template
• Product Leaflet
• Package Leaflet
4.6Accessories & Options
4.6.1 Optional Extras
1. Various timers, external controls, etc. are available as optional
extras.
1M Drain Pipe ‘Trace Heating’ Element --------------------------- 720644401
2M Drain Pipe ‘Trace Heating’ Element --------------------------- 720664101
3M Drain Pipe ‘Trace Heating’ Element --------------------------- 720664201
5M Drain Pipe ‘Trace Heating’ Element --------------------------- 720664401*
*Where the drain is between 3 & 5 metres a 5 metre kit can be used and
“doubled back” upon itself.
Any of the above MUST be fitted ONLY by a qualified competent
person. Further detail can be found in the relevant sales literature
and at www.baxi.co.uk
22EcoBlue Advance Combi7219715 - 03 (04/17)
5Before Installation
Before Installation5
5.1Installation Regulations
WARNING
Installation, repair and maintenance must only be
carried out only by a competent person. This
document is intended for use by competent persons,
Installation must be carried out in accordance with the prevailing
regulations, the codes of practice and the recommendations in
these instructions. Please refer to 1.5.1 and 1.6.2
Installation must also respect this instruction manual and any
other applicable documentation supplied with the boiler.