Baxi Combi 105 HE Owner's Manual

© Baxi Heating UK Ltd 2011
Please keep these instructions in a safe place.
If you move house, please hand them over to the next occupier.
Baxi Combi 105 HE
Gas Fired Wall Mounted
Condensing Boiler
User’s Operating Instructions
© Baxi Heating UK Ltd 2011
Natural Gas
Baxi Combi 105 HE
G.C.No47 075 18
© Baxi Heating UK Ltd 2011 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 1988.
Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address:
The Company Secretary, Baxi Heating UK Limited, Brooks House, Coventry Road, Warwick. CV34 4LL
Full acknowledgement of author and source must be given.
WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages.
1.0 Quick Reference Guide 3
2.0 Troubleshooting 4
3.0 Fault Indication 6
4.0 System Pressure & Temperature 7
5.0 Clearances 8
6.0 Care of the Boiler 9
7.0 Legislation 10
8.0 Emergency 11
9.0 Warranty & Service 12
Section Page
Contents
Boiler Controls - see opposite page
for Operating Quick Reference Guide
Where fitted, user label for
optional timer to be applied here
0086
ISO 9001
FM 00866
The Benchmark Scheme
Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk
1.0 Quick Reference Guide
© Baxi Heating UK Ltd 2011
Reset
bar
0
1
2
3
4
ON/OFF/Reset Selector Switch
Indicator
Neons
Central Heating
Temperature Control
System Pressure Gauge
OFF Position
The boiler will not operate.
Central Heating Temperature Control
Turn the knob clockwise to increase or anticlockwise to decrease the temperature. Range 30 - 85° C.
Power On Indicator - The indicator will illuminate when there is power to the boiler.
Domestic Hot Water Indicator - The indicator will illuminate when hot water is being supplied to a tap or shower.
Boiler On - The indicator will illuminate when there is a demand for heat to the boiler.
Central Heating System Pressure - The normal operating water pressure is between 1 and 2.0 bar. If the pressure exceeds 3 bar the safety pressure valve will operate and a fault is indicated. Contact your Installer.
Reset
Reset
Central Heating & Hot Water
Both Heating & Hot Water will operate.
Reset
Hold for approx 5 seconds and release.
Indicator
Neons
Domestic Hot Water Temperature Control
Reset
Domestic Hot Water
Hot Water will operate.
Burner On Indicator - The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water.
Domestic Hot Water Pre-Heat Temperature Control
Turn the knob clockwise to increase or anticlockwise to decrease the temperature. Range 35 - 65° C.
Position of
Optional Timer
Reset
30o40o50o60o70o80
o
2
1
3
4
0
bar
30o40o50o60o70o80
o
2.0 Troubleshooting
© Baxi Heating UK Ltd 2011
START
Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker).
If no gas, consult your supplier.
Is the ON/OFF/Reset Select Switch in the ( ) position and the Power ON indicator lit ?
Is the ( ) light on and the ( ) on ?
Check electricity to the boiler is switched on.
Reset
Power On Indicator
Boiler On Indicator
Burner On Indicator
Boiler operating satisfactorily.
bar
0
1
2
3
4
Is the Central Heating System Pressure needle in the GREEN section, between 1 and 2.5 bar ?
If the reading falls below 1 bar repressurise the system as described in section 4.1.
Is the ( ) indicator neon on ?
Boiler not working
NO
NO
YES
YES
YES
NO
Turn the ON/OFF/Reset Selector Switch to Reset.
Reset
NO
YES
YES
NO
If boiler does not Reset
Flame Failure Neon
30o40o50o60o70o80
o
30o40o50o60o70o80
o
30o40o50o60o70o80
o