Quick Setup (IBM/IBM Compatible under Windows 95/98/ME/2000)
Please Read Carefully When Setting Up Your New Monitor
Monitor Screen Adjustment and Resolution Setting Procedure for IBM/IBM Compatible
Computers with Windows based OS system.
Before adjusting the monitor, all the necessary drivers should be installed to your System
and resolution has to be set to manufacturer’s recommended preset of 1280 x 1024 @ 60Hz,
70Hz, 72Hz or 75 Hz.
To check the resolution, press the “UP” button on the monitor and the “Information” will
display under the OSD. Information will have Resolution, Horizontal and V ertical (Refresh rate)
frequency information.
To change the resolution to its factory recommended preset.
1. On a Windows 95, 98, ME or 2000, press right button on a Mouse to execute the Pop-up
menu.
2. Press “Properties” to execute the “Display Properties”
3. Press “Setting” and change the resolution to 1280 x 1024.
4. Press “Apply or OK” to select and press “OK” to keep the selected resolution.
5. Go back to “Display Properties” - “Setting” - “Advanced properties” - “Adapter”
6. On Adapter property, change the refresh rate to 60Hz, 70Hz, 72Hz or 75Hz. If you don’t
have these options, choose “Adapter Default”. (60Hz recommended)
Screen Adjustment Procedure
1. Press the “AUTO” button.
2. If you still don’t have a clear display monitor, please refer to step 3.
3. Start “Shut Down” in Windows 95/98/ME/2000 - It will display moire on screen
4. Press “Up” button then the OSD menu will pop-up.
5. Adjust the “Frequency” under the OSD to reduce or get rid of the vertical display noise
(Jail bars).
6. Once the vertical display noise disappears, press adjust the “Phase” to reduce or get rid of
the horizontal display noise (Snowy effect).
4 User’s Guide
Quick Setup (IBM/IBM Compatible under Windows NT 4.0)
Please Read Carefully When Setting Up Your New Monitor
Monitor Screen Adjustment and Resolution Setting Procedure for IBM/IBM Compatible
Computers with W indows based OS system.
Before adjusting the monitor, all the necessary drivers should be installed to your System
and resolution has to be set to manufacture’s recommended preset of 1280 x 1024 @ 60Hz,
70Hz, 72Hz or 75Hz.
To check the resolution, press the “UP” button on the monitor and the “Information” will
display under the OSD. Information will have Resolution, Horizontal and V ertical (Refresh rate)
frequency information.
To change the resolution to its factory recommended preset.
1. On a Windows NT 4.0, press right button on a Mouse to execute the Pop-up menu.
2. Press “Properties” to execute the “Display Properties”
3. Press “Setting” and change the resolution to 1280 x 1024.
4. Change “Refresh Frequency” to 60Hz, 70Hz, 72Hz or 75Hz. (60Hz recommended)
Screen Adjustment Procedure
1. Press the “AUTO” button.
2. If you still don’t have a clear display monitor, please refer to step 3.
3. Start “Shut Down” in Windows 95/98/ME/2000 - It will display moire on screen
4. Press “Up” button then the OSD menu will pop-up.
5. Adjust the “Frequency” under the OSD to reduce or get rid of the vertical display noise
(Jail bars).
6. Once the vertical display noise disappears, press adjust the “Phase” to reduce or get rid of
the horizontal display noise (Snowy effect).
AMM19TK2/AMM19TK2(HB) 5
Quick Setup (Macintosh)
Please Read Carefully When Setting Up Your New Monitor
1. Set your Macintosh Adapter on pages 23 and 24.
2. Push the “APPLE” icon on the upper left corn and execute Control Panel->
Monitors&Sound. Select “Thousands” for the Color Depth, Select “1280X1024, 60Hz,70Hz, 72Hz or 75Hz” for the Resolution. (60Hz recommended)
* On some Apple G3 or newer systems, you may not need to use the Macintosh Adapter.
Screen Adjustment Procedure
1. Press the “AUTO” button on the monitor.
6 User’s Guide
INTRODUCTION
Congratulations on your purchasing of the AMM19TK2/AMM19TK2(HB) high performance
TFT LCD monitor .
Product Description and Intended Use
The AMM19TK2/AMM19TK2(HB) Monitor is an intelligent, microprocessor-based TFTLCD monitor intended for use in medical applications. It has an ergonomically designed
display and is compatible with most analog RGB (Red, Green, Blue) display standards.
The AMM19TK2/AMM19TK2(HB) Monitor has the following features:
•Advanced Viewing Solution (AVS): Our sophisticated filter extends the viewing angle of
the screen image, without sacrificing contrast ratio and brightness.
•Advanced Timing Setup (A TS): A unique technology from the One T ouch Auto Adjustment.
Pressing the Auto Adjust button on the front panel, automatically optimizes position,
phase, clock, contrast and color balance. This allows the user to maximize the perfect
screen setting in the shortest amount of time.
ergonomic mounting solutions to allow creative use in conjunction to product application.
•The monitor is able to properly function even in case of upgrade video cards or software
because of the wide auto-scanning compatibility range without requiring to buy a new
monitor.
•The internal microprocessor digitally controls auto-scanning. For horizontal scan
frequencies between 24.8 KHz and 60.2 KHz, and vertical scan frequencies between 50.0 Hz
and 85.1 Hz. In each frequency mode, the microprocessor-based circuitry allows the monitor
to function at the precision-of a fixed frequency.
•The resident memory allows for storing factory default settings and also additional user
adjustment parameters.
•The maximum resolution achievable is SXGA (1280 x 1024)
•The compact and sleek cabinet design saves lot of your desk space and makes your desk
look neat and tidy.
•The monitor is compliant with VESA-DPMS power management standard. In order to
save energy, the monitor must be connected to a system compliant with the standard.
The monitor is certified by UL International to medical standard UL60601-1, EN60601-1 and
EN60601-1-2. It is also CE marked for sale into the European Community for integration or
use with medical products.
AMM19TK2/AMM19TK2(HB) 7
Product Description
Please check the following items are present when you unpack the box, and save the packing
materials in case you will need to ship or transport the monitor in future.
•AMM19TK2 or AMM19TK2/HB LCD Monitor and two video cable (1) VGA HDDB15
cable (1) DVI-D cable
•AC Power cord
•AC-Adapter
•Composite V ideo BNC Jack Cable and Super V ideo Cable
•User Manual
CAUTION
Manufacturer : Ault Korea
Model No : MW116
*Touchscreen Data Cable and Floppy Disk (Touchscreen driver) optional
8 User’s Guide
W arnings and Cautions
Please read this manual and follow its instructions carefully. The words warning, caution,
and note carry special meanings and should be carefully reviewed:
Warranty is void if any of these warnings ar e disregarded.
ADVAN Int’l Corp accepts full responsibility for the effects on safety, reliability, and
performance of the equipment only if:
• Re-adjustments, modifications, and/or repairs are carried out exclusively by
ADV AN Int’l Corp.
• The electrical installation of the relevant operating room complies with the
applicable IEC and CE requirements.
Warning Federal law (United S tates of America) restricts this device to use by ,
or on order of a physician.
The ADVAN Int’l Corp AMM19TK2/AMM19TK2(HB) monitor has been tested under UL
60601-1 standard and UL listed for Medical application.
ADVAN Int’l Corp reserves the right to make improvements in the product(s) described
herein. Product(s), therefore, may not agree in detail to the published design or
specifications. All specifications are subject to change without notice. Please contact
ADVAN Int’l Corp directly or phone your local ADVAN Int’l Corp sales representative or
agent for information on changes and new products.
AMM19TK2/AMM19TK2(HB) 9
Warnings
1. Read the operating manual thoroughly and be familiar with its contents prior to using
this equipment.
2. Carefully unpack the unit and check if any damage occurred during shipment.
3. Should any solid object or liquid fall into the panel, unplug the unit and have it checked
by qualified personnel before operating it any further.
4. Uplug the unit if it is not to be used for an extended period of time. To disconnect the
cord, pull it out by the plug. Never pull the cord itself.
5. Be a qualified physician, having complete knowledge of the use of this equipment.
6. Test this equipment prior to a medical procedure. This monitor was fully tested at the
factory before shipment.
7. Avoid removing covers on control unit to avoid electric shock.
8. Attempt no internal repairs or adjustments not specifically detailed in this operating
manual.
9. Pay close attention to the care, cleaning instructions in this manual. A deviation may
cause damage (refer to the Cleaning section on page 14).
10. DO NOT STERILIZE MONITOR.
11. Read the entire instruction manual before assembling or connecting the camera.
12. Do not place the monitor or any other heavy object on the power cord. Damage to the
cable can cause fire or electirc shock.
13. Monitor with power supply is suitable for use in patient environment.
14. DO NOT stack more than 8 boxes high
This equipment has been tested and found to comply with the limits for medical devices in
IEC 601-1-2:2003. These limits are designed to provide reasonable protection against
harmful interference in a typical medical installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to other
devices in the vicinity. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to other devices,
which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving device.
- Increase the separation between the equipment.
- Connect the equipment into an outlet on a circuit different from that to which the other
device(s) are connected.
- Consult the manufacturer or field service technician for help.
NOTICES TO USER
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC W ARNING
This equipement generates or uses radio frequency energy. Changes or modifications to this
equipment may cause harmful interference unless the modifications are expressly approved
in the instruction manual. The user could lose the authority to operate this equipment if an
unauthorized change or modification is made.
10 User’s Guide
Cautions
1. The AC Adapter must be plugged into a Grounded power outlet.
2. Use only the proprietary AMM19TK2/AMM19TK2(HB) power supply for the
AMM19TK2/AMM19TK2(HB) monitor. Make a proper connection by ensuring that the
shrink tubing completely secures the connection between the DC power cord and the
extension cord.
3. Turn power off when unit is not in use.
4. Never operate the unit right after having transported from a cold location directly to a
warm location.
5. Do not expose the monitor to moisture or directly apply liquid cleaners directly to the
screen. Spray the cleaning solution into a soft cloth and clean gently.
6. Handle the monitor with care. Do not strike or scratch the screen.
7. Do not block the monitor cooling vents. The monitor is cooled by natural convection and
has no fan.
8. Do not force the monitor past 28 degrees of vertical when adjusting the screen position.
(For monitors equipped with stands only.)
9. Remove the power module and connection when transporting the unit.
10. Save the original carton and associated packing material. They will be useful should you
have to transport or ship the unit.
11. Allow adequate air circulation to prevent internal heat buildup.
12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains,
draperies) that may block the ventilation slots.
13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.
14. The unit is designed for operation in a horizontal position. Never operate the unit in a
vertical position.
15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker .)
16. Do not expose the monitor to moisture or excessive dust.
17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or IEC
60601-1-1 harmonized national standard or the combination should be evaluated. Do not
touch the patient with signal input or output connectors.
18. Use only a hospital grade power supply cord.
19. This equipment generates, uses, and can radiate radio frequency energy. If not installed
correctly and or not used in accordance with these instructions, it may cause harmful
interference with other devices. This may be determined by turning the equipment off and
on. The user is encouraged to try to correct the interference through one or more of the
following measures:
• Reorient or relocate the receiving device.
• Increase the separation distance between the equipment.
• Connect the equipment to an outlet on a circuit different from that to which the other
device(s) are connected.
• Consult the manufacturer or field service technican for help.
20. Grounding reliability can only be achieved when the equipment is connected to an
equipment receptacle labeled “Hospital Only” or “Hospital Grade.”
NoteTo connect to an international power supply, use a an attachment plug appropriate
for the power outlet.
NoteRefer to the “Electromagnetic Compatibility” (EMC) section of this manual to
ensure EMC. The AMM19TK2/AMM19TK2(HB) must be installed and operated according
to the EMC information provided in this manual.
Symbol Definitions
AMM19TK2/AMM19TK2(HB) 11
IPX1 Degrees of protection against the ingress of water.
12 User’s Guide
EU Declaration of Conformity for Medical Applications
A Declaration of Conformity has been filed for this product. A sample of this
document may be found in the addendum which accompanied this manual. For a
copy of the Declaration of Conformity document, please contact ADVAN Int’l
Corp. and request for AMM19TK2 or AMM19TK2/HB DOC.
Prepare for Unpack
Before you unpack your monitor, prepare a suitable workspace. Y ou need a stable
and level surface near a grounded wall outlet in an area which is relatively free of
glare from sunlight or other sources of bright light. The monitor is cooled by natural
convection (it has no fan).
For optimum performance, do not block the cooling vents.
While unpacking the monitor, inspect it and other package contents for shipping
damage that could cause a fire or shock hazard. Immediately report any shipping
damage to the carrier or transportation company and contact customer service for
monitor in the future or in case of return.
After you unpack the monitor, make sure the following items are included
• Monitor with 1.5 meter(5ft)monitor-to computer video cable
• AC adapter with cable
CAUTION: AC Adapter must be plugged into Grounded a power outlet)
CAUTION : AC adapter
Manufacturer: Ault korea
Model No: MW116
• Touchscreen cable if monitor has touchscreen option
• This operations manual
Note: Your system provider may offer alternative cords or cables
depending on the installation requirement and local geography issues.
AMM19TK2/AMM19TK2(HB) 13
SCREEN POSITION ADJUSTMENT
In order to optimize the best viewing position, you can adjust the tilt of the monitor by using
both of your hands to hold the edges of the monitor as shown in the figure below. The monitor can be adjusted to 28 degrees up as indicated by arrow below.