BARCO AMM15TK2 User Manual

AUTO-SCANNING WITH DIGITAL CONTROL LCD COLOR MEDICAL MONITOR
AMM15TK3/AMM15TK2-TE/AMM15TK2-TEW
Operation Manual
The serial number is located on the
back of the monitor
WARNING
The title “WARNING” is used to inform the users of possible causes that could inflict the injury, death, or property damage to the patients.
CAUTION The title “CAUTION” is used to inform the users of possible causes that could inflict the patients although it might not severe enough to cause deaths.
NOTE The title “NOTE” is used to inform the users of items that are of importance in terms of installation, operation, or maintenance of the Equipment although the failure does not inflict the bodily harm to the patients.
ADAVN INT’L CORP.2005
“ELO” is a Registered trademark of Elo TouchSystems, Inc., All other trademarks are the property of their reference owners. This document is subject to change without notice. Advan provides this information as reference only. Reference to other vendor’s products does not imply any recommendation or endorsement.
Revision Control
Date Description
07162005 Document number
2

TABLE OF CONTENTS

Warnings and Cautions…………………………………………… 4 Warnings…………………………………………………………….. 5 Cautions……………………………………………………………… 6 Product Description and Intended Use…….………………….. 7 Functional Description……………………………………………. 8 Product Features…………………………………………………… 8 Cleaning instructions……………………………………………… 9 Symbol Explanations……………………………………………… 10 Regulatory Compliance…………………………………………… 11 EU Declaration of Conformity for Medical Applications……. 11 Prepare for Unpack………………………………………………… 11~12 DDC…………………………………………………………………... 13 Installation…………………………………………………………... 13 Screen Position Adjustment…………………………………….. 14 Connecting the Power Cord…………………………………….. 14 Power Management Function…………………………………… 15 Power Management System…………………………………….. 15 User Controls………………………………………………………. 16 Standard OSD Operation…………………………………………. 16 OSD Function Description (Analog)……………………………. 17 OSD Function Description (C or S Video )…….………………. 18 Specification Of AMM15TK3..…………………………………….. 19 Supported Modes…………………………………………………... 20 Connectors…………………………………………………………... 21 Troubleshooting…………………………………………………….. 22 Electromagnetic Compatibility…………………………………… 24~26 Description of Warranty……………………………………………. 27~28 Tounchscreen User’s Manual………………………………………29~30
3
Warnings and Cautions
Please read this manual and follow its instructions carefully. The words warning, caution, and note carry special meanings and should be carefully reviewed:
Warranty is void if any of these warnings are disregarded.
ADVAN Int’l Corp accepts full responsibility for the effects on safety, reliability, and performance of the equipment only if:
• Re-adjustments, modifications, and/or repairs are carried out exclusively by ADVAN Int’l Corp.
• The electrical installation of the relevant operating room complies with the applicable IEC and CE requirements.
Warning Federal law (United States of America) restricts this device to use by,
or on order of a physician.
The ADVAN Int’l Corp AMM15TK3 Series Monitor has been tested under UL 60601-1 standard and UL listed for Medical application.
ADAVN Int’l Corp reserves the right to make improvements in the product(s) described herein. Product(s), therefore, may not agree in detail to the published design or specifications. All specifications are subject to change without notice. Please contact ADVAN Int’l Corp directly or phone your local ADVAN Int’l Corp sales representative or agent for information on changes and new products.
4

Warnings

1. Read the operating manual thoroughly and be familiar with its contents prior to using this equipment.
2. Carefully unpack the unit and check if any damage occurred during shipment.
3. Should any solid object or liquid fall into the panel, unplug the unit and have it checked by qualified personnel before operating it any further.
4. Unplug the unit if it is not to be used for an extended period of time. To disconnect the cord, pull it out by the plug. Never pull the cord itself.
5. Be a qualified physician, having complete knowledge of the use of this equipment.
6. Test this equipment prior to a surgical procedure. This monitor was fully tested at the factory before shipment.
7. Avoid removing covers on control unit to avoid electric shock.
8. Attempt no internal repairs or adjustments not specifically detailed in this operating manual.
9. Pay close attention to the care, cleaning instructions in this manual. A deviation may cause damage (refer to the Cleaning section on page 9).
10. DO NOT STERILIZE MONITOR.
11. Read the entire instruction manual before assembling or connecting the camera.
12. Do not place the monitor or any other heavy object on the power cord. Damage to the cable can cause fire or electric shock.
13. Monitor with power supply is suitable for use in patient environment.
14. DO NOT stack more than 8 boxes high
This equipment has been tested and found to comply with the limits for medical devices in IEC 601-1-2:2003. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occu r in a particular installation. If this equipment does cause harmful interference to other devices, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving device.
- Increase the separation between the equipment.
- Connect the equipment into an outlet on a circuit different from that to which the other device(s) are connected.
- Consult the manufacturer or field service technician for help.
NOTICE TO USER This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference,and (2) this device must accept any interference received,including interference that may cause undesired operation.
FCC WARNING This equipment generates or uses radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if unauthorized change or modification is made.
5
Cautions
1. The AC Adapter must be plugged into a Grounded power outlet.
2. Use only the proprietary AMM15TK3 power supply for the AMM15TK3 monitor. Make a proper connection by ensuring that the shrink tubing completely secures the connection between the DC power cord and the extension cord.
3. Turn power off when unit is not in use.
4. Never operate the unit right after having transported from a cold location directly to a warm location.
5. Do not expose the monitor to moisture or directly apply liquid cleaners directly to the screen. Spray the cleaning solution into a soft cloth and clean gently.
6. Handle the monitor with care. Do not strike or scratch the screen.
7. Do not block the monitor cooling vents. The monitor is cooled by natural convection and has no fan.
8. Do not force the monitor past 28 degrees of vertical when adjusting the screen position. (For monitors equipped with stands only.)
9. Remove the power module and connection when transporting the unit.
10. Save the original carton and associated packing material. They will be useful should you have to transport or ship the unit.
11. Allow adequate air circulation to prevent internal heat buildup.
12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains, draperies) that may block the ventilation slots.
13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.
14. The unit is designed for operation in a horizontal position. Never operate the unit in a vertical position.
15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker.)
16. Do not expose the monitor to moisture or excessive dust.
17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or IEC 60601-1-1 harmonized national standard or the combination should be evaluated. Do not touch the patient with signal input or output connectors.
18. Use only a hospital grade power supply cord.
19. This equipment generates, uses, and can radiate radio frequency energy. If not installed correctly and or not used in accordance with these instructions, it may cause harmful interference with other devices. This may be determined by turning the equipment off and on. The user is encouraged to try to correct the interference through one or more of the following measures:
•Reorient or relocate the receiving device.
•Increase the separation distance between the equipment.
•Connect the equipment to an outlet on a circuit different from that to which the other device(s) are connected.
•Consult the manufacturer or field service technician for help.
20. Grounding reliability can only be achieved when the equipment is connected to an equipment receptacle labeled “Hospital Only” or “Hospital Grade.” Note To conn ect to an intern ational power supply, use a an attachment plug appropriate for the power outlet. Note Refer to the “Electromagnetic Compatibility” (EMC) section of this manual to ensure EMC. The AMM15TK3 must be installed and operated according to the EMC information provided in this manual.
6
Product Description and Intended Use
The AMM15TK3 Series Medical Monitor is an intelligent, microprocessor-based TFT-LCD monitor intended for use in medical applications. It has an ergonomically designed display and is compatible with most analog RGB (Red, Green, Blue) display standards.
Advan AMM15TK3 Series Medical Monitor consists of a low-profile molded plastic monitor head, video and a power supply. Options include a Super sonic Acoustic Wave (AMM15TK2­TEW) or Resistive (AMM15TK2-TE) touchscreen with interface cable. The display shows 262,144 colors with a pixel matrix of 1024 columns by 768rows.
Advanced Viewing Solution (AVS): Our sophisticated filter extends the viewing angle of
the screen image, without sacrificing contrast ratio and brightness.
Advanced Timing Setup (ATS): A unique technology from ADVAN is the One Touch
Auto Adjustment. Pressing the Auto Adjust button on the front panel, automatically optimizes position, phase, frequency, contrast and color balance. This allows the user to maximize the perfect screen setting in the shortest amount of time.
Advanced Mounting Solution (AMS): ADVAN and Ergoton share their technology to
improve flat panel environment, utilizing numerous ergonomic mounting solutions to allow creative use in conjunction to product application.
The monitor is able to properly function even in case of upgrade video cards or software because of the wide auto-scanning compatibility range without requiring to buy a new monitor.
The internal microprocessor digitally controls auto-scanning. For horizontal scan frequencies between 24.8 KHz and 60.2 KHz, and vertical scan frequencies between 50.0 Hz and 85.1 Hz. In each frequency mode, the microprocessor-based circuitry allows the monitor to function at the precision-of a fixed frequency.
The resident memory allows for storing factory default settings and also additional user adjustment parameters.
The maximum resolution achievable is XGA (1024 x 768), best suited for Windows applications
The compact and sleek cabinet design saves lot of your desk space and makes your desk look neat and tidy.
The monitor is compliant with VESA-DPMS power management standard. In order to save energy, the monitor must be connected to a system compliant with the standard.
The monitor is certified by UL International to medical standard UL 60601-1, EN60601-1 and EN60601-1-2. It is also CE marked for sale into the European Community for integration or use with medical products.
7
Functional Description and Product Features
Display Type Color Active Matrix LCD
• Control Buttons:
-OSD menu display: Menu Button
-Adjustment increase and Adjustment decrease and
-Power on/off
-Auto adjust & exit OSD menu: Auto Button
Adjust brightness/contrast directly with the adjustment increase/decrease buttons.
Indicators
-On-Screen Display "OSD" function
-Power LED indicator is lit when the monitor is on and blinking when the monitor is power-save/standby mode
• Display formats
-VGA, SVGA, and XGA
-VESA DDC1 and DDC2B Plug and Play Functions
8
Cleaning Instructions
Advan AMM15TK2 Series Monitors will continue to operate normally while being clean ed in a fashion normal for a hospital environment. This includes cleaning with a damp (wrung out), mild soapy cloth. Protection from various chemicals used for cleaning.
Advan AMM15TK2 Series Monitors will withstand non-abrasive cloths and cleaning solution s used in hospitals for like equipment. This is typically warm water and mild detergent for all surfaces or 70% IPA for the touchscreen surface. Possible chemicals include:
70% isopropyl alcohol
6% aqueous ammonia
Cidex (2.4% glutaraldehyde solution)
Sodium Hypochlorite (bleach) 10%
“Green soap” USP
0.5% Chlorhexidine in 70% isopropyl alcohol
Ovation®
Formula 409®
Fantastic®
• Wex Cide®
To clean the screen, do not spray liquid cleaners directly on to the unit. Stand away Form the monitor and spray cleaning solution onto a cloth. Without applying excessive pressure, clean the screen with the slightly dampened rag.
9
Symbol Explanations
Indicates proof of conformity to applicable European Economic Community Council directives and to harmonized standards published in the official journal of the European Communities Tested and certified by UL to UL60601-1. If this mark appears with the indicators "C" and "US" the product is certified for both the U.S and Canadian markets, to the applicable U.S and Canadian standards. Tested to comply with FCC Class B standards.
Dangerous high voltage.
Consult accompanying documents.
Indicates protective earth ground.
For indoor use only.
Direct Current
DC power control switch
10
Loading...