SureCross™ DX81P6 FlexPower™ Supply Module
Delivers and manages dc voltage from six 3.6V dc lithium primary batteries
Features
Wireless solution for powering a FlexPower™ Node and sensor devices
•
Unique power management system to run the FlexPower Node and a device through
•
switched power outputs for up to ten years, depending on the power requirements of
the device and required update rates
Six 3.6V dc lithium “D” cell batteries
•
IP67 sealed enclosure
•
FlexPower systems allow for a true wireless solution as the Node can be powered by battery
power (3.6 to 5.5V dc). Battery life is application specific. Contact Banner Engineering’s
application engineers for a battery life calculation for your specific application.
For additional information and a complete list of replacement parts, please refer to Banner
Engineering’s website, www.bannerengineering.com/surecross.
Models
Model Power Batteries Cable
DX81P6 3.6V dc Battery Six 3.6V lithium “D” Cells 5-pin Euro Pigtail QD
WARNING . . .
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A
sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner
Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
Printed in USA 01/08 P/N 131628 rev. B
Not To Be Used for Personnel Protection
SureCross™ DX81P6 FlexPower™ Supply Module
Battery Replacement
Battery Replacement
To replace the lithium “D” cell battery pack in the DX81P6 FlexPower™ battery kit,
Remove the four screws mounting the clear plastic battery pack cover to the housing.
1.
Remove the cover and foam spacer.
2.
Disconnect the discharged battery pack.
3.
Remove the discharged battery pack and replace with a new battery pack. Caution:
4.
There is an explosion risk if the battery pack is replaced with an incorrect type.
After replacing the battery pack, allow up to 60 seconds for the device to power up.
5.
Properly dispose of the used battery packs according to local regulations by taking it to a
hazardous waste collection site, an e-waste disposal center, or any other facility qualified to
accept lithium batteries.
As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn or
expose them to high temperatures. Do not recharge, crush, disassemble, or expose the
contents to water.
Replacement battery pack model number: BWA-BATT-002. For pricing and availability, contact
Banner Engineering.
Only SureCross™ FlexPower™ DX80
devices may be powered from this supply.
2 P/N 131628 rev. B
Hookup Diagram
5-pin M12 Quick Disconnect Pinout
3 Blue dc common (GND)
5 Gray 3.6 to 5.5V dc
Banner Engineering Corp. • Minneapolis, MN U.S.A
www.bannerengineering.com • Tel: 763.544.3164