Banner DX80N9X7S-P15E, DX80N2X7S-P15E User Manual

Sure Cross® Performance P15E Node
197408
Datasheet
The Sure Cross® wireless system is a radio frequency network with integrated I/O that operates in most environments to eliminate the need for wiring runs.
The Performance Series P15E Node can wirelessly control any AC-powered devices, including lights (including dimming levels), fan speed, and motors. For higher amperage applications, relays can be used to control contactors. By using a current transducer and its analog inputs you can monitor energy/power levels for connected devices.
• Remotely control—Lights, fans, and motors; use in conjunction with equipment health monitoring sensors to shut down motors remotely when potential issues are detected
• Eliminate control wires—The Sure Cross wireless system is a radio frequency network with integrated I/O that removes the need for control wires.
• Reduce complexity—Facility or machine reconfiguration made easier; great for retrofit applications
• Deploy easily—The relays and wireless radio are housed in a single device, simplifying installation on existing equipment and enabling deployments in remote and hard-to-access locations where implementing a wired solution would be difficult, impractical, or not cost-effective
• Wireless industrial I/O device with two AC/DC relay outputs, two discrete PNP outputs, two 0– 10 V dc analog outputs, two discrete NPN or PNP (selectable) inputs, and two 0–10 V dc analog inputs
• Supply voltage of 100–277 V ac at 50/60 Hz
• Courtesy power output of 25 W (24 V dc)
• AC power Mini-style quick disconnect (QD)
• Selectable transmit power levels of 250 mW or 1 Watt for 900 MHz models and 65 mW for 2.4 GHz models
• DIP switches for user
• Frequency Hopping Spread Spectrum (FHSS) technology ensures reliable data delivery within the unlicensed Industrial,
• Transceivers provide bidirectional communication between the Gateway and Node, including fully acknowledged data transmission
• Lost RF links are detected and relevant outputs set to user-defined conditions
field wireable through a 1/2-inch NPSM port using 1/2-inch conduit, cable gland, or
configuration
Scientific, and Medical (ISM) band
For additional information, updated documentation, and a list of accessories, refer to Banner Engineering's website,
www.bannerengineering.com/wireless
WARNING:
• Risk of Electric Shock
• Disconnect or turn off the power before installing, removing, or servicing the P15E Node.
• Install and connect the P15E Node in accordance with the National Electrical Code (NEC) and any applicable local code requirements and supply the P15E Node with an appropriate fuse box or circuit breaker (see Supply Voltage rating in the Specifications).
• Install the P15E Node at the end of a conduit run.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.
CAUTION: Never Operate 1 Watt Radios Without Antennas
To avoid damaging the radio circuitry, never power up Sure Cross® Performance or Sure Cross MultiHop (1 Watt) radios without an antenna.
Original Document 197408 Rev. C
.
19 April 2018
Sure Cross® Performance P15E Node
CAUTION: Electrostatic Discharge (ESD)
ESD Sensitive Device. This product uses semiconductors that can be damaged by electrostatic discharge (ESD). When performing maintenance, care must be taken so the device is not damaged. Disconnect power from the device when accessing the internal DIP switches. Proper handling procedures include wearing anti­static wrist straps. Damage from inappropriate handling is not covered by warranty.
Models
Models Frequency I/O
DX80N9X7S-P15E 900 MHz ISM Band Inputs: Two selectable discrete, two 0 to 10 V analog
DX80N2X7S-P15E 2.4 GHz ISM Band
Outputs: Two AC/DC relay (SPDT), two PNP discrete, two 0 to 10 V analog
Configuration Instructions
Setting Up Your Wireless Network
To set up and install your wireless network, follow these steps.
Disconnect the power from your Sure Cross devices.
1. Configure the DIP switches of all devices.
2. If your device has I/O, connect the sensors to the Sure Cross devices. If your device does not have I/O, skip this step.
3. Refer to the wiring diagrams to apply power to all devices.
• For housed models, the Gateway's LED 1 is solid green and the Node's LED 2 link to the Gateway.
• For board-level models, the Gateway's LED is solid green and the Node's LED flashes red to indicate there is no radio link to the Gateway.
4. Form the wireless network by binding the Nodes to the Gateway. If the binding instructions are not included in the datasheet, refer to the product manual for binding instructions.
5. Observe the LED behavior to verify the devices are communicating with each other.
• For housed models, the Gateway's LED 1 is solid green and the Node's LED 1
communicating with the Gateway.
• For board-level models, the Gateway's LED is solid green and the Node's LED flashes green to indicate it is
communicating with the Gateway.
6. Configure any I/O points to use the sensors connected to the Sure Cross devices.
7. Conduct a site survey between the Gateway and Nodes. If the site survey instructions are not included in this datasheet, refer to the product manual for detailed site survey instructions.
8. Install your wireless sensor network components. If installation instructions are not included in this datasheet, refer to the product manual for detailed installation instructions.
For additional information, including installation and setup, weatherproofing, device menu maps, troubleshooting, and a list of accessories, refer to one of the following product manuals.
• Sure Cross® Quick Start Guide:
• Sure Cross® Wireless I/O Network Instruction Manual:
• Web Configurator Instruction Manual (used with "Pro" and DX83 models):
• Host Controller Systems Instruction Manual:
128185
132607
134421
132114
flashes red to indicate there is no radio
flashes green to indicate it is
Configure the DIP Switches
Before changing DIP switch positions, disconnect the power. DIP switch changes are not recognized until after power is cycled to the device.
For parameters not set via DIP switches, use the User Configuration Tool (UCT) to make configuration changes. For parameters set using the DIP switches, the DIP switch positions override any changes made using the User Configuration Tool.
Accessing the Internal DIP Switches
To access the internal DIP switches, follow these steps:
1. Unscrew the four screws that mount the cover to the bottom housing.
2. Remove the cover from the housing without damaging the ribbon cable or the pins the cable plugs into.
3. Gently unplug the ribbon cable from the board mounted into the bottom housing.
2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 197408 Rev. C
Sure Cross
®
Performance P15E Node
4. Remove the black cover plate from the bottom of the device's cover. The DIP switches are located behind the rotary dials.
After making the necessary changes to the DIP switches, place the black cover plate back into position and gently push into place. Plug the ribbon cable in after verifying that the blocked hole lines up with the missing pin. Mount the cover back onto the housing.
DIP Switch Settings
Switches
Device Settings 1 2 3 4 5
900 MHz transmit power level: 1 Watt (30 dBm) OFF*
900 MHz transmit power level: 250 mW (24 dBm), DX80 compatibility mode ON
Modbus or UCT configured (overrides DIP switches 3-8) OFF*
DIP switch configured ON
Inputs sourcing (PNP) OFF*
Inputs sinking (NPN) ON
Link loss output: zero OFF* OFF*
Link loss output: one OFF ON
Link loss output: hold last state ON OFF
Link loss output: user configuration ON ON
* Default configuration
Discrete Input Type
Select the type of discrete input sensors to use with this device: sourcing (PNP) sensors or sinking (NPN) sensors.
Link Loss Outputs
The Sure Cross® wireless devices use a deterministic radio link time-out method to address RF link interruption or failure. When a radio link fails, all pertinent wired outputs are set to communications link result in predictable system behavior.
Following a radio link time-out, all outputs linked to the Node in question are set to de-energize (discrete outputs to zero, analog outputs to 0 mA or 4 mA), energize (discrete outputs to one, analog outputs to 20 mA), or hold the last stable state/value. Use the DIP switches to select the link loss output state.
Modbus/User
Configuration Tool (UCT) or DIP Switch Configured
In Modbus/UCT Configured mode, use the User Configuration Tool (UCT) or a Modbus command to change the device parameters. DIP switch positions 3 through 8 are ignored. In DIP Switch parameters listed in the table.
defined states until the link is recovered, ensuring that disruptions in the
Configured mode, use the DIP switches to configure the
Transmit Power Levels
The 900 MHz radios transmit at 1 Watt (30 dBm) or 250 mW (24 dBm). While the Performance radios operate in 1 Watt mode, they cannot communicate with the older 150 mW radios. To communicate with 150 mW radios, operate this radio in 250 mW mode. For
2.4 GHz models, this DIP switch is disabled. The transmit power for 2.4 GHz is
fixed at about 65 mW EIRP (18 dBm), making the
2.4 GHz Performance models automatically compatible with older 2.4 GHz models.
Mixing Performance and Non-Performance (150 mW) Radios in the Same Network
To comply with federal regulations, the 150 mW radios and 1 Watt radios communicate differently. All Performance models offer the ability to select between 250 mW and 1 Watt operation using the DIP switches. To mix Performance radios with non­Performance radios:
• Operate Performance radios in 250 mW mode, not 1 Watt mode
• Set non-Performance (150 mW) radios to use Extended Address Mode
The 150 mW, 250 mW, and 1 Watt networks operate when collocated, but verify the antenna separation distance between a Gateway and Node or between two Gateways are at least 10 feet apart. For more detailed instructions about setting up your wireless network, refer to the Quick Start Guide (p/n
128185
).
P/N 197408 Rev. C www.bannerengineering.com - Tel: +1-763-544-3164 3
24V
GND
C-
C+ DI1 DI2 AI2
AO1 AO2 DO3 DO4
AI1
Analog IN
24V
+
sensor
Analog OUT
GND
24V
sensor
Discrete IN
PWR
10-30V dc
Discrete IN
GND
dc common
Discrete OUT
GND
PWR
10-30V dc
Load
dc common
Sure Cross® Performance P15E Node
Wiring Your Sure Cross® Device
Use the following wiring diagrams to first wire the sensors and then apply power to the Sure Cross devices.
Wiring for Power and I/O
24V. 24 V courtesy power output
GND. Gound/dc common connection
C+. Serial communication line for the Gateway; no connection for the Nodes
C–. Serial communication line for the Gateway; no connection for the Nodes
Com. Common
AI1. Analog IN 1
AI2. Analog IN 2
AO1. Analog OUT 1
AO2. Analog OUT 2
DO3. Discrete OUT 3
DO4. Discrete OUT 4
L. AC line
N. AC neutral
. AC Earth
DI1. Discrete IN 1
DI2. Discrete IN 2
NC. Normally Closed
NO. Normally Open
R1. Relay 1
R2. Relay 2
Connecting power to the communication pins will cause permanent damage. Do not exceed analog input ratings for analog inputs. Only connect sensor outputs to analog inputs.
Analog Input Wiring (24 V dc Courtesy Power) Analog Output Wiring (24 V dc Courtesy Power)
PWR for the discrete sensors may be 10 V dc to 30 V dc, or it may be wired to the 24 V dc (24V) courtesy power supplied by the device.
Discrete Input Wiring for PNP Sensors
4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 197408 Rev. C
Discrete Input Wiring for NPN Sensors Discrete Output Wiring (PNP)
N
L
100-277 V ac
AC Neutral
AC Earth
AC Line
Normally Closed
AC Line
Normally Open
Relay 1
NO
NC
COM
Normally Closed
AC Line
Normally Open
Relay 2
NO
NC
COM
Normally Closed
Normally Open
Relay 1
NO
NC
COM
Normally Closed
Normally Open
Relay 2
NO
NC
COM
N
L
100-277 V ac
AC Neutral
AC Earth
AC Line
L
Switched AC
+
24 V dc
Load
Normally Closed
Normally Open
Relay 1
NO
NC
COM
Normally
Closed
Normally Open
Relay 2
NO
NC
COM
+
24 V dc
Load
Load
Load
Load
Sure Cross® Performance P15E Node
Wiring Diagrams for AC Power
Power Only Switched AC Relays Power and Switched AC Relays
Nominal current per relay not to exceed 10 A.
Total nominal current not to exceed 10 A.
Connecting ac or dc power to the communication pins will cause permanent damage. Use the access hole with a 1/2-inch conduit fitting, cable gland, or Mini-style quick disconnect (QD) at the bottom of the housing to field-wire ac power and ac circuits.
Wiring Diagrams for 24 DC Courtesy Power Out
24 V DC Courtesy Power Out
Switched 24 V dc Power Out
Use the access hole with the watertight gland or M12/Euro-style quick disconnect (QD) at the top of the housing to field-wire courtesy power to external field instruments.
LED Behavior for the Nodes
Nodes do not sample inputs until they are communicating with the Gateway. The radios and antennas must be a minimum distance apart to function properly. Recommended minimum distances are:
2.4 GHz 65 mW radios: 1 foot 900 MHz 150 mW and 250 mW radios: 6 feet 900 MHz 1 Watt radios: 15 feet
LED 1
Flashing green Radio Link Ok
Flashing red Flashing red Device Error
P/N 197408 Rev. C www.bannerengineering.com - Tel: +1-763-544-3164 5
LED 2 Node Status
Flashing red, 1 per 3 sec No Radio Link
Sure Cross® Performance P15E Node
Sure Cross® User Configuration Tool
The User Configuration Tool (UCT) offers an easy way to link I/O points in your wireless network, view I/O register values, and set system communication parameters when a host system is not part of the wireless network. The software runs on any computer with the Windows Vista, Windows 7, Windows 8, or Windows 10 operating system.
Use a USB to RS-485 adapter cable to connect a standalone DX80 Gateway to the computer. For DXM Controllers with an internal DX80 radio, connect a computer to the DXM Controller using a USB or Ethernet connection. Download the most recent revisions of the UCT software from Banner Engineering's website:
wireless
.
www.bannerengineering.com/
The USB to RS-485 adapter cable is not required for the DXM Controller. For standalone DX80 Gateway devices use:
• USB to RS-485 adapter cable model BWA-UCT-900 for 1 Watt radios
• USB to RS-485 adapter cable model BWA-HW-006 for all other radios
Holding Registers
Modbus Holding Register EIP Registers
Gateway Node Node Min. Max. Min. Max.
1 1 + (Node# × 16) 0 + (Node# × 8)
2 2 + (Node# × 16) 1 + (Node# × 8) Discrete IN 2 0 1 0 1
3 3 + (Node# × 16) 2 + (Node# × 8) Analog IN 1 (V) 0.0 10.0 0 65535
4 4 + (Node# × 16) 3 + (Node# × 8) Analog IN 2 (V) 0.0 10.0 0 65535
5 5 + (Node# × 16) 4 + (Node# × 8)
6 6 + (Node# × 16) 5 + (Node# × 8)
7 7 + (Node# × 16) 6 + (Node# × 8) Reserved
8 8 + (Node# × 16) 7 + (Node# × 8) Device Message
9 9 + (Node# × 16) 0 + (Node# × 8)
10 10 + (Node# × 16) 1 + (Node# × 8) Relay OUT 2 0 * 1 * 0 1
11 11 + (Node# × 16) 2 + (Node# × 8) Discrete OUT 3 0 1 0 1
12 12 + (Node# × 16) 3 + (Node# × 8) Discrete OUT 4 0 1 0 1
13 13 + (Node# × 16) 4 + (Node# × 8) Analog OUT 1 (V) 0.0 10.0 0 65535
14 14 + (Node# × 16) 5 + (Node# × 8) Analog OUT 2 (V) 0.0 10.0 0 65535
15 15 + (Node# × 16) 6 + (Node# × 8) Control Message
16 16 + (Node# × 16) 7 + (Node# × 8) Reserved
Instance 100 / N7
Instance 112 / N14
I/O Type
Discrete IN 1 0 1 0 1
Relay OUT 1 0 * 1 * 0 1
I/O Range
Holding Register
Representation (Dec)
* Relay Output Truth Table
Relay Connection
0 (OFF) 1 (ON)
Normally Closed Closed Open
Normally Open Open Closed
I/O Value
Installing Your Sure Cross® Radios
Please refer to one of the following instruction manuals for details about successfully installing your wireless network components.
• DX80 and Performance Wireless I/O Network Instruction Manual:
6 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 197408 Rev. C
132607
Sure Cross® Performance P15E Node
Specifications
Performance Radio Specifications
Radio Range
Antenna Minimum Separation Distance
Radio Transmit Power
Spread Spectrum Technology
P15E Model Specifications
1
900 MHz, 1 Watt: Up to 9.6 km (6 miles)
2.4 GHz, 65 mW: Up to 3.2 km (2 miles)
900 MHz, 1 Watt: 4.57 m (15 ft)
2.4 GHz, 65 mW: 0.3 m (1 ft)
900 MHz, 1 Watt: 30 dBm (1 W) conducted (up to 36 dBm EIRP)
2.4 GHz, 65 mW: 18 dBm (65 mW) conducted, less than or equal to 20 dBm (100 mW) EIRP
FHSS (Frequency Hopping Spread Spectrum)
900 MHz Compliance (1 Watt)
FCC ID UE3RM1809: This device complies with FCC Part 15, Subpart C,
15.247 IC: 7044A-RM1809
2.4 GHz Compliance FCC ID UE300DX80-2400 - This device complies with FCC Part 15, Subpart
C, 15.247 ETSI EN 300 328: V1.8.1 (2012-06) IC: 7044A-DX8024
Antenna Connection
Ext. Reverse Polarity SMA, 50 Ohms Max Tightening Torque: 0.45 N·m (4 lbf·in)
Link Timeout
Gateway: Node: Defined by Gateway
Configurable via User Configuration Tool (UCT) software
Supply Voltage and Current
Nominal voltage: 120–277 V ac at 60 Hz in North America Nominal voltage: 100–277 V ac at 50/60 Hz outside North America Maximum supply current: 0.37 A Maximum power consumption: 25 W
Interface
Two bi-color LED indicators, Two buttons, Six character LCD
Housing
Polycarbonate housing and rotary dial cover; polyester labels; EDPM rubber cover gasket; nitrile rubber, non-sulphur cured button covers Weight: 0.51 kg (1.13 lbs) Mounting: 1/4-inch or M7 Max. Tightening Torque: 0.56 N·m (5 lbf·in)
Wiring Access
Two 1/2-inch NPSM ports, 14 threads/inch (1/2-14 NPSM)
Certifications
Analog Input
0 to 10 V Input Rating: 10 V Impedance: Approximately 220 Ohms Sample Rate: 62.5 milliseconds Report Rate: 1 second or On Change of State (1% change in value) Accuracy: 0.2% of full scale +0.01% per °C Resolution: 12-bit
Output State Following Timeout
De-energized (OFF)
Required Overcurrent Protection
WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations.
Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to
Supply Wiring (AWG) Required Overcurrent Protection (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
Relay Outputs
SPDT (Form C) relay 277 V ac, 10 A Minimum Mechanical Life: 10,000,000 Surge breakdown voltage
Analog Output
0 to 10 V Update Rate: 125 milliseconds Accuracy: 1.0% of full scale +0. 01% per °C Resolution: 12-bit
2
(Between contacts and coil) (Initial): 10,000 V
www.bannerengineering.com
.
Environmental Specifications for the E Housing
Environmental Ratings
IEC IP65
Shock and Vibration
IEC 68-2-6 and IEC 68-2-27 Shock: 30g, 11 millisecond half sine wave, 18 shocks Vibration: 0.5 mm p-p, 10 to 60 Hz
1
Radio range is with the 2 dB antenna that ships with the product. High-gain antennas are available, but the range depends on the environment and line of sight. Always verify your wireless network's range by performing a Site Survey.
2
Wave is standard shock voltage of ±1.2 × 50 µs according to JEC-212-1981
P/N 197408 Rev. C www.bannerengineering.com - Tel: +1-763-544-3164 7
Operating Conditions
–40 °C to +85 °C (–40 °F to +185 °F) (Electronics); –20 °C to +80 °C (–4 °F to +176 °F) (LCD) 95% maximum relative humidity (non-condensing) Radiated Immunity: 10 V/m (EN 61000-4-3) Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device.
Refer to the Sure Cross® Wireless I/O Networks Instruction Manual (p/n
132607
) for installation and waterproofing
instructions.
Sure Cross® Performance P15E Node
Included with Model
The following items ship with the DX80 radios.
• BWA-HW-059: Access Hardware Kit for "E" Housing Models, containing one 1/2-inch vented plug and one 1/2-inch gland
• BWA-HW-003: PTFE tape
• BWA-9O2-C (900 MHz) or BWA-2O2-C (2.4 GHz): Antenna, 2 dBd Omni, Rubber Swivel RP-SMA Male. (Not included with Internal antenna models)
• Quick Start Guide (
128185
for DX80 Gateways or
152653
for MultiHop models)
Warnings
Install and properly ground a qualified surge suppressor when installing a remote antenna system. Remote antenna configurations installed without surge suppressors invalidate the manufacturer's warranty. Keep the ground wire as short as possible and make all ground connections to a single-point ground system to ensure no ground loops are created. No surge suppressor can absorb all lightning strikes; do not touch the Sure Cross® device or any equipment connected to the Sure Cross device during a thunderstorm.
Exporting Sure Cross® Radios. It is our intent to fully comply with all national and regional regulations regarding radio frequency emissions. Customers who want to re-export this product to a country other than that to which it was sold must ensure the device is approved in the destination country. A list of approved countries appears in the section of the product manual. The Sure Cross wireless products were certified for use in these countries using the antenna that ships with the product. When using other antennas, verify you are not exceeding the transmit power levels allowed by local governing agencies. Consult with Banner Engineering Corp. if the destination country is not on this list.
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is
identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:
www.bannerengineering.com
specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at
.
Radio Certifications
©
Banner Engineering Corp. All rights reserved
Loading...