ORION® Handheld Meter Reading System 2.2 Software Installation
Page iv August 2012
Installation Manual
INTRODUCTION
This manual describes the process of installing the ORION® handheld meter reading system software and includes the
following two main sections:
•Uninstalling Previous Software Versions
•Installing ORION Meter Reading System Software for Trimble Ranger, including ORION Field Application (OFA) 2.2
AUDIENCE AND PURPOSE
Instructions are included for existing Trimble® Ranger handheld users who are updating to OFA 2.2 software, and for users
who are installing OFA 2.2 for the first time.
NOT: NTo provide the best solution for our customers, Badger Meter continually improves software programs and updates
this Installation Manual to reflect upgrades. Therefore, some discrepancies may be detected between the installed
software and this manual.
SYSTEM REQUIREMENTS
The handheld must meet the system specifications as identified in the most recent version of the “ORION Trimble Ranger
Handheld” Technical Brief, ORI-T-56.
OFA 2.2 requires a the handheld with a Windows® Mobile 5 operating system or newer to run correctly. The Mobile operating
system version number is displayed on the About screen. You can access the About screen by going to Start> Settings>
System tab> About.
Page 5 August 2012
ORION® Handheld Meter Reading System 2.2 Software Installation
UNINSTALLING PREVIOUS SOFTWARE VERSIONS ON THE HANDHELD
Before installing the new software, uninstall any older versions of the software on the handheld.
The Factory Reset method (1) is recommended. Read the descriptions below and choose the appropriate procedure based on
your handheld setup.
1. Uninstalling the Previous Software Using Factory Reset (Recommended)
Factory reset is the recommended method for uninstalling the previous version of the meter reading software. This
procedure resets the Trimble Ranger to "factory fresh" condition and removes all previously added software. Refer to
"Uninstalling Previous Software Using Factory Reset" on page 7.
CAUTION: If you previously added software to the handheld that you do not want to remove, use the Alternative
method, "Uninstalling Previous Software Using Remove Programs" on page 8.
2. Uninstalling the Previous Software Using Remove Programs (Alternative)
This procedure uses the Windows tool, "Remove Programs," for uninstalling the previous meter reading software
version. Remove Programs allows you to select the programs you want to uninstall. It can be used when the
handheld has other software that you do not want to remove. Refer to "Uninstalling Previous Software Using Remove
Programs" on page 8.
3. (Kiosk mode) Uninstalling the Previous Software
For handhelds in Kiosk mode, use procedure 1, "Uninstalling Previous Software Using Factory Reset" on page 7, to
uninstall previous Kiosk software and all other previously added software.
If you previously added software to the handheld that you do not want to remove, use the instructions "Uninstalling
Previous Software from Kiosk Mode" on page 9.
No Previous Software
If there is no previous version of the ORION meter reading software on the handheld, skip the uninstall procedures and go
directly to "Installing the ORION Meter Reading Software for the Trimble Ranger" on page 12.
Page 6 August 2012
Installation Manual
Uninstalling Previous Software Using Factory Reset
Start the factory reset uninstall procedure with the handheld powered on.
NOT:NRead through all the steps before you start since you must be prepared to perform the first two steps quickly.
CAUTION: If you previously added software to the handheld that you do not want to remove, use the Alternative
method, "Uninstalling Previous Software Using Remove Programs" on page 8.
1. Press and hold the green power button in lower left corner of the handheld keypad. When the countdown nishes
and the screen goes blank, release the power button.
2. When you hear a beep, immediately press and hold the Fn+ F+D keys.
Release the keys when you hear another beep.
3. The Restore Factory Default State screen displays asking if you want to continue. Press ENTER.
Result: The handheld automatically reboots and displays the Windows Mobile screen.
4. Tap the screen to start the reset process.
5. Align the touch screen by tapping the cross hairs. Continue to tap the cross hairs until the screen aligns.
Result: The Location screen displays.
6. On the Location screen, use the drop-down menu to select the correct time zone. Then tap Next.
7. At the Password screen, tap Skip.
Result: The Complete screen displays.
8. Tap the screen to complete the reset.
The handheld is now ready for the new software installation. Refer to "Installing ORION Meter Reading Software for the
Trimble Ranger" on page 12.
Page 7 August 2012
ORION® Handheld Meter Reading System 2.2 Software Installation
Uninstalling Previous Software Using Remove Programs
1. Press the green power key on the keypad to power
up the handheld.
2. Tap the Start button in the top left corner of
the handheld screen to see the menu.
3. Tap Settings, tap the System tab and tap Remove Programs.
Result: The Remove Programs screen opens.
4. Tap to select the le labeled "Badger Meter, Inc
Badger Field Ap…" le. Then tap the Remove
button.
Result: A window opens to conrm the removal as
shown in Figure 3.
Figure 1: Settings> System tab
Figure 2: Remove Programs
5. Tap Yes to conrm the program removal.
6. The "Microsoft.NET CF 3.5" le may also display on
the Remove Programs screen. If it does, tap to select
it.
7. Then tap the Remove button and tap Yes to conrm
the program removal.
Figure 3: Confirm program removal
Once the previous software programs are uninstalled, the handheld is ready for the new software installation. Refer to
"Installing ORION Meter Reading Software for the Trimble Ranger" on page 12.
Page 8 August 2012
Uninstalling Previous Software from Kiosk Mode
NOT:NThis procedure is only for handhelds in Kiosk mode.
Operating the handheld in Kiosk mode, the main handheld screen appears as it does in Figure 4.
Figure 4: Kiosk mode
To uninstall the previous software on a handheld in Kiosk mode, follow these steps.
Installation Manual
NOT:NYou can also uninstall Kiosk software by using the procedure "Uninstalling the Previous Software Using Factory Reset"
on page 7. However, if there is software on the handheld other than the ORION software that you do not want to
remove, use this procedure.
1. Tap the screen to the right of the words "Badger
Trimble Ranger" in the title bar.
Result: The Unlock button appears.
2. Tap the Unlock button.
Figure 5: Tap Unlock button
Page 9 August 2012
ORION® Handheld Meter Reading System 2.2 Software Installation
3. Type in the code to unlock the handheld.
NOT:NIf you do not have the code, contact
Badger Meter Technical Support for the
code to unlock Kiosk mode.
Result: When the handheld is unlocked, it returns to
Admin mode and the Windows start menu is displayed
as shown in Figure 7.
4. Tap Settings on the Windows Start menu.
Figure 6: Enter unlock code
5. Tap the System tab. Then tap Remove Programs.
Figure 7: Windows Start menu
Figure 8: Remove Programs
Page 10 August 2012
6. Tap "Askarya Pocket Kiosk."
Then tap Remove.
7. Tap Yes to conrm the program removal.
Installation Manual
Figure 9: Confirm program removal
8. Tap to select each remaining program.
For each program, tap Remove. Then tap Ye s to
confirm the program removal
9. When all programs are removed, tap ok to exit
Remove Programs.
Figure 10: Remove remaining programs
Once the previous software programs are uninstalled, the handheld is ready for the new software installation. Refer to
"Installing ORION Meter Reading Software for the Trimble Ranger" on page 12.
Page 11 August 2012
ORION® Handheld Meter Reading System 2.2 Software Installation
INSTALLING ORION METER READING SOFTWARE ON THE HANDHELD
The ORION Meter Reading System software comes loaded on one CD provided by Badger Meter. Three software files are
included on the CD:
•0 – .NET framework
•1 – Badger Field Applications. These include:
-ORION Field Application (OFA) 2.2
-ORION CE Profile Extraction
-ORION Endpoint Utility
-ORION CE Repeater Programmer
-IHD Programmer
-GALAXY Programmer
-BMI FTP
•2 – Daylight Savings update
IMPORTANT
The files must be installed in order: 0, 1, 2.
Transferring Software Files from the CD to a USB Memory Stick
1. Load the ORION Meter Reading System CD on a computer with a CD drive.
2. The CD folder may open automatically. If not, open Windows Explorer, browse to the CD drive location and open the
CD folder.
Result: Three les labeled 0, 1 and 2 will be displayed as shown in Figure 11.
Figure 11: Software installation files
3. Insert a memory stick into the USB port on the computer.
4. Select the three .cab les from the CD and copy them to the memory stick.
Result: The ORION Meter Reading System software files on the memory stick are ready to be installed on the handheld.
5. Safely remove the memory stick from the computer.
Page 12 August 2012
Installing Meter Reading Software on the Handheld
1. Insert the memory stick with the software files into the USB port on the handheld.
Figure 12: Start>Programs>File Explorer
2. Tap Start > Programs > File Explorer.
Installation Manual
3. Tap the drop-down menu in the tool bar and select Hard Disk.
NOT:NIf the memory stick is not inserted, Hard Disk does not display.
Figure 13: Hard disk
4. Tap Hard Disk to see the software les.
IMPORTANT
Make sure you install the three files in order: 0, 1, 2.
5. Tap to select the rst le labeled "0 NETCFv35.
wm.arm.v4i."
Result: The file location window opens as shown in
Figure 15 on the next page.
Figure 14: Software installation files
Page 13 August 2012
ORION® Handheld Meter Reading System 2.2 Software Installation
6. Select Device for the install location.
Result: The le installs automatically.
Figure 15: Install on Device
7. After the "0" le installs, a screen displays with the option to restart or continue as shown in Figure 16.
Tap Cancel to continue.
Figure 16: Choose Cancel to continue
Result: The software selection screen displays again.
8. Tap to select the second le labeled "1 Badger
Field Applications."
Result: The le location window opens.
9. Select Device to install as in step 6.
Result: The le installs automatically and a
successful installation window opens as shown in
Figure 18 on the next page.
Figure 17: Software installation files
Page 14 August 2012
Figure 18: Field Applications successfully installed
10. Tap ok in the top right corner of the screen.
Result: The software selection screen displays again.
11. Tap to select and install the last le labeled "2 Daylight Savings Fixer_WIn..."
Installation Manual
Figure 19: Installation in progress
Result: The last file installs. When the window closes, the system automatically reboots and returns to the start screen.
NOT:NIf the system does not reboot, restart the handheld prior to opening any software applications. To restart,
press and hold the green power key. The screen will show a countdown timer. Continue holding the power
key until the countdown is completed. The handheld will automatically restart.
12. Tap Start > Programs > File Explorer > Badger File Apps to access the software les as shown in
Figure 20.
The software applications on the handheld are now
ready to use.
13. Remove the memory stick from the handheld.
Figure 20: Handheld Field Applications
Page 15 August 2012
ORION® Handheld Meter Reading System 2.2 Software Installation
Kiosk Mode
After the meter reading software installation is complete, the Kiosk mode application is located in the My Documents folder
and can be activated from that location.
1. Go to Start > Programs > File Explorer > My Device > My Documents.
2. Tap the le "KioskMode_Badger_Field_A..." to install Kiosk mode.
Figure 21: Kiosk mode application
Result: Kiosk mode installs automatically.
After the program installs, the software applications on the handheld are ready to use.
Page 16 August 2012
Intentional blank page
Installation Manual
Page 17 August 2012
ORION® Handheld Meter Reading System 2.2 Software Installation