Badger Meter OG-CNDAM, OG-KAM, OG-TAERM, OG-TAERKM, OG-AM User Manual

...
LM OG-AM series
User Manual
LM OG-AM
LM OG-CNDAM
Oval gear meters with MID approved register and integrated datalogger
LM_OG-AM_BA_02_1163 (May 2019)
LM OG-AM series
CONTENT
1. Disclaimer ................................................................................................................................................................................................................................... 1
2. Basic safety recommendations .......................................................................................................................................................................................... 1
3. Before putting into operation ............................................................................................................................................................................................ 2
3.1 Recommended filter sizes ........................................................................................................................................................................................ 3
4. Warranty ...................................................................................................................................................................................................................................... 3
5. Details of unit operation LM OG-AM series ................................................................................................................................................................... 4
5.1 RESET button ................................................................................................................................................................................................................. 4
5.2 Datalogger: A non-volatile memory .................................................................................................................................................................... 4
5.3 Battery ............................................................................................................................................................................................................................. 4
5.4 Interruption of batch process ................................................................................................................................................................................. 4
5.5 Functional control ....................................................................................................................................................................................................... 4
5.6 Totalizer........................................................................................................................................................................................................................... 5
5.7 Monitoring of false pulses for MID conform meters ...................................................................................................................................... 5
5.8 Installation procedure LM OG ................................................................................................................................................................................ 5
6. Programming of LM OG-AM and LM OG-TAERM series ........................................................................................................................................... 6
7. Calculating the correction factor....................................................................................................................................................................................... 7
7.1 Calculation based default settings ....................................................................................................................................................................... 7
7.2 Recalculation of an existing correction factor ................................................................................................................................................. 7
8. Pulse output at register OG-TAERM ................................................................................................................................................................................. 7
9. Browse and program data logger ..................................................................................................................................................................................... 8
9.1 Search for a dispense ................................................................................................................................................................................................. 8
9.2 Programming the datalogger ................................................................................................................................................................................ 9
10. Display correction factor .................................................................................................................................................................................................... 9
11. Checksum & serial number ............................................................................................................................................................................................ 10
12. Status messages ................................................................................................................................................................................................................. 10
13. Changing the Battery ....................................................................................................................................................................................................... 10
14. MID approval ....................................................................................................................................................................................................................... 11
15. Manufacturer declaration ............................................................................................................................................................................................... 11
16. DIN ISO and EMC certificate ........................................................................................................................................................................................... 11
17. Return of goods for repair / Harmlessness declaration....................................................................................................................................... 11
Page II LM_OG-AM_BA_02_1163 May 2019
Disclaimer
LM OG-AM
Standard inline meter
LM OG-KAM
Coated standard inline meter
LM OG-CDAM
Pistol meter with handle, sightglas and swivel
LM OG-CNDAM
Pistol meter with handle, sightglas, swivel and outlet
LM OG-TAERM
Inline meter with pulse output
LM OG-TAERKM
Coated inline meter with pulse output

1. DISCLAIMER

The user/purchaser is expected to read and understand the information provided in this manual, follow any listed safety precautions and instructions and keep this manual with the equipment for future reference. The information in this manual has been carefully checked and is believed to be entirely reliable and consistent with the product described. However, no responsibility is assumed for inaccuracies, nor does Badger Meter assume any liability arising out of the application and use of the equipment described. Should the equipment be used in a manner not specified by Badger Meter, the protection provided by the equipment may be impaired and the warranty voided. The meter is conform to the MID regulations for liquids other than water.

2. BASIC SAFETY RECOMMENDATIONS

Before installing or using this product, please read this instruction manual thoroughly. Only qualified personnel should install and/or repair this product. If a fault appears, contact your distributor.
Installation
Do not place any unit on an unstable surface that may allow it to fall. Never place the units above a radiator or heating unit. Route all cabling away from potential hazards. Isolate from the mains before removing any covers.
Power connection
Use only the type of power source suitable for electronic equipment. If in doubt, contact your distributor. Ensure that any power cables are of a sufficiently high current rating. All units must be earthed to eliminate risk of electric shock. Failure to properly earth a unit may cause damage to that unit or data stored within it.
Protection class
Following devices have protection class IP65:
All devices have to be protected against dripping water, water, oils, etc.
Setup & operation
Adjust only those controls that are covered by the operating instructions. Improper adjustment of other controls may result in damage, incorrect operation or loss of data.
Cleaning
Switch off all units and isolate from mains before cleaning. Clean using a damp cloth. Do not use liquid or aerosol cleaners.
May 2019 LM_OG-AM_BA_02_1163 Page 1
Before putting into operation
!
Strainer
Strainer Flow direction
Repair of faults
Disconnect all units from power supply and have it repaired by a qualified service person if any of the following occurs:

WARNING

Failure to adhere to these safety
instructions may result in damage to the
product or serious bodily injury.
RoHs
Our products are RoHs compliant.
Battery disposal
The batteries contained in our products need to be disposed of as per your local legislation acc. to EU directive 2006/66/EG.

3. BEFORE PUTTING INTO OPERATION

Please check that the technical data of the installation match with those of the lube meter, for example connections, pressure, flow range and medium. Once the meter has been installed, please make sure that no air, pressure shocks or particles can damage the meter.
Read the following information and have a thorough understanding before proceeding with meter installation. Only qualified personnel should perform meter installation.
Install a strainer or Y or basket as close to the inlet side of the meter as possible. Strainers prevent dirt and other fluid contaminants from impeding meter performance. Strainers require periodic cleaning, as clogged strainers also impede meter performance. Contact your local representative for specific information, per your specific application.
Figure 1: Meter installation
Page 2 LM_OG-AM_BA_02_1163 May 2019
Warranty

Filter / Pore size (in mesh)

Filter / Pore size (in mm)

½"
60
0,250
Turn off any associated pumps to reduce line pressure and slowly fill the line and meter with fluid before restarting pumps. Doing so reduces the possibility of meter damage caused by errant air pressures in the line and meter.
Make sure all pipe conforms to the same pressure output rating as the pump.
Make sure to apply thread sealant to all pipe threads.
Make sure to install the meter as shown in figure 1.
Check for and repair leaks upon initialization of fluid flow.

3.1 Recommended filter sizes

Please check all connections to leakage. After the installation we recommend to perform several transactions into an approved piston. Should the use of different oil viscosities show discrepancies by the error limit, it can be immediately corrected at the site. The pretested meters can be calibrated by technicians or the officials of the national authorities (MID).

4. WARRANTY

Badger Meter warrants meters and parts manufactured by it and supplied hereunder to be free from defects in materials and workmanship for a period of 24 months from date of shipment. If within such period any meters or parts shall be proved to Seller´s satisfaction to be defective, such meters or parts shall be repaired or replaced at Seller´s option. Seller´s obligation hereunder shall be limited to such repair and replacement and shall be conditioned upon Seller´s receiving written notice of any alleged defect within 10 days after its discovery and, at Seller´s option, return of such meters or parts to Seller, f.o.b. its factory. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES WHATSOEVER INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES (EXCEPT OF TITLE) OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Badger Meter shall not be liable for any defects attributable to acts or omissions of others after shipment, nor any consequential, incidental or contingent damage whatsoever.
May 2019 LM_OG-AM_BA_02_1163 Page 3