Badger Meter M7600 Specifications

M-Series® M7600
Electromagnetic Flow Meters
DESCRIPTION
The Badger Meter® M7600 flow meter combines the most advanced electromagnetic flow metering technology with a simple, yet robust, output for batching systems found in industrial applications.
Based on Faraday’s Law of electromagnetic induction, M7600 meters can accurately measure and control most batching needs in the industrial market. Its completely open cross-section flow tube design with no moving parts, makes it the ideal metering device for batching of a wide range of industrial conductive fluids.
While other metering technologies are hindered by the presence of suspended solids in the process fluid, the M7600 will continue to measure flow, provided the conductivity remains higher than 5 micromhos/cm. Having a non-obstructive flow-through pipe design allows particulates to pass through the meter body. The signal voltage, measured by the electrodes, passes through the entire cross sectional profile for improved accuracy.
The M7600 meter features an intuitive PC interface used for selecting the scale factor, unit of measure and pules per unit, making these meters the most straight-forward metering systems available in the Industry.
OPERATION
The M7600 meters have stainless steel flow tubes with internal isolating linings. Two electromagnetic coils are located outside the flow tube, diametrically opposed to each other and protected by a carbon steel housing. Two electrodes, inserted into the flow tube, are positioned flush with the internal diameter of the tube and perpendicular to the coils. The coils are energized by a pulsed DC voltage provided by the electronic converter, and a magnetic field is generated across the flow tube section. According to Faraday’s law, when this magnetic field is cut by the conductive liquid flowing through the meter, a voltage is generated in the liquid. This voltage is directly proportional to the liquid flow velocity, and therefore to the actual volumetric flow rate of the liquid. The electronic converter measures this voltage, processes the signal, and provides two digital pulse outputs, scalable to the desired volumetric value. These digital pulse outputs can be connected to a batch controller, a totalizer display unit for monitoring purposes, or to both devices simultaneously.
The operation of the M7600 meter is not affected by a moderate presence of most suspended solids in the liquid. Variations of liquid temperature, viscosity or density have no influence in the principle of operation.
APPLICATION
Because of its inherent advantages over other more conventional technologies, the M7600 meter can be used in the majority of industrial process batching applications and is the meter of choice for concrete batching operations. Whether the fluid is water or something very viscous, contains a moderate amount of solids or requires special handling, the M7600 meter will be able to accurately provide flow measurement.
FEATURES
• Sizes: 1/2…4 in.
• Standard accuracy ±0.5% of rate
• ±0.1% repeatability
• Open cross-section design: no pressure loss, no moving parts, no maintenance required
• Unaffected by the presence of most suspended solids in the liquid
• Pulsed DC magnetic field for maximum zero point stability
• Two standard pulse outputs: solid-state relay and open collector output, compatible with most batch controllers and totalizer displays
• Programmable scale factor
• Long life, corrosion-resistant liner (PTFE)
• NEMA 4 standard enclosure
• Complies with NIST Handbook HB44 for batching meters
MAG-DS-00508-EN-03 (December 2017)
Product Data Sheet
M-Series® M7600 Electromagnetic Flow Meters
SPECIFICATIONS
Performance
Sizes Sizes 1/2…4 in. (15…100 mm) Flow Range 0.14…1320 gpm (0.53…5000 lpm)
±0.5% of rate for velocities greater than 1.64 ft/s, ±0.008 ft/s less than 1.64 ft/s
Accuracy
Repeatability ±0.1% Fluid Temperature Maximum fluid temperature: 212° F (100° C) Storage Temperature –40…140° F (–40…60° C) Ambient Temperature –4…140° F (–20…60° C) Fluid Conductivity Minimum liquid conductivity: 5 micromhos/cm Flow Direction Unidirectional Pressure Limits Working pressure: 232 psi (16 bar)
Materials of Construction
Flow Tube AISI 316 stainless steel Detector Housing Flange material: carbon steel, enamel paint finishing Liner Material PTFE End Connection ANSI 150# carbon steel flanges Electrodes Materials Hastelloy C22
Amplifier Housing
Cable Entries Two 1/2 in. NPT cord grip Grounding Rings Standard (pre-installed) Optional Grounding Electrodes 2
Inputs
Power Supply 92…275 VAC Coil Excitation Pulsed DC Programming PC user interface
Outputs
Digital Output
Frequency Output Maximum output frequency: 10 kHz Pulse Width 50% duty cycle
Approvals
Meter Enclosure NEMA 4 NIST Handbook B44 Complies for batching applications
±0.5% of rate for velocities greater than 0.50 m/s, ±2.5 mm/s less than 0.50 m/s Note: The maximum measuring error depends on the installation conditions.
Powder-coated cast aluminum, NEMA 4 Meter mounted only
Output 1: solid-state relay up to 230V, 500 mA Output 2: Opto-isolated open collector, 50 mA at 24V DC
Page 2 December 2017MAG-DS-00508-EN-03