HR-E® LCD Encoder
DESCRIPTION
Applications: The High Resolution encoder (HR-E LCD) is a fully
electronic, solid-state encoder with no moving parts. It is designed
for use with all current Badger Meter Recordall® Disc, Turbo Series,
Compound Series, Combo Series and Fire Service meters and
assemblies. The HR-E LCD provides connectivity with Badger Meter
ORION® and GALAXY® AMR/AMI endpoints and other AMR/AMI
technology solutions approved by Badger Meter.
OTE:N For more detailed information, refer to the document
HR-E LCD Encoder User Manual, available at
www.badgermeter.com.
Field Programmable: The HR-E LCD encoder comes standard as
factory programmed to customer specifications, with the option for
field programming the unit of measure, meter type, meter model,
digit resolution from the encoder, billing units, and rate-of-flow
time and units. Programming is performed through the IR port via
a computer.
Electronic Resolution: Standard encoded output from the HR-E
LCD is nine digits.
Status Indicators: Status indicators are sent as part of the encoder
extended message to AMR/AMI systems such as ORION Cellular,
Fixed Network and Migratable endpoints that are capable of
receiving an extended message. The details can also be read
through an IR interface.
Mounting: Icons on the HR-E LCD encoder face indicate encoder
status and alarm conditions. The fully potted encoder assembly
has a bayonet mount compatible with all Recordall Disc, Turbo
Series, Compound Series, Combo Series and Fire Series meters
and assemblies. The bayonet mount positions the encoder in any
of four orientations for visual reading convenience. The HR-E LCD
encoder can be removed from the meter without disrupting
water service.
Magnetic Drive Communication: The HR-E LCD encoder detects
movement of the wet side meter magnet with magnetic sensors to
provide reliable and dependable encoded communication.
Tamper-resistant Features:
Unauthorized removal of the HR-E LCD encoder is inhibited by a
tamper-resistant Torx seal screw. Torx seal screws are provided as
standard accessories. Optional proprietary tamper-proof screws are
also available.
Magnetic sensors detect and report an attempted encoder
removal. In addition, the HR-E LCD encoder is resistant to magnetic
tampering. The encoder detects an attempted tamper—as well as
encoder removal—and sends a tamper alarm in either situation.
Approved endpoints capable of receiving the alarms, such as
ORION Cellular, Fixed Network and Migratable endpoints, can then
report the tamper condition to the meter reading software.
SPECIFICATIONS
Straight reading, permanently sealed,
Encoder type
Encoder display
Unit of measure
Flow rate Seconds, minutes, and hours
Numerals 7 mm (0.28") high
Weight 11 ounces
Humidity 0…100% condensing
Temperature
Status
indicators
Signal output Industry standard ASCII format
Signal type
Battery
Battery Life 20 years (calculated)
electronic LCD absolute encoder with
field-programmable option
Status indicators, unit of measure, billing units,
automatic toggle between 9-digit and 6-digit
consumption (segmented leak detector in this
mode), rate of flow, meter model
U.S. gallons, Imperial gallons, cubic feet,
cubic meters, and liters clearly identified on
register face
Storage: – 40…60° C (– 40…140° F)
Max. ambient for 1 hr: 72° C (150° F)
Electronics & Display: –10…60° C (14…140° F)
Electronic and visual icons for:
meter functioning correctly, meter alarm
(indicates temperature limits exceeded,
magnetic tamper or encoder removal), reverse
flow, suspected leak, 30-day no usage, end of
battery life
Three-wire synchronous for AMR/AMI solutions
Red = clock/power; Black = ground; Green = data
Lithium thionyl chloride AA cell, fully
encapsulated within encoder housing
ENC-DS-01763-EN-03 (October 2015)
Product Data Sheet
HR-E® LCD Encoder
Construction: The housing of the HR-E LCD encoder is constructed
of an engineered polymer enclosure and a polycarbonate lens.
For long-term performance, the enclosure is fully encapsulated,
weatherproof, and UV-resistant to withstand harsh environments
and to protect the electronics in flooded or submerged pit
applications. An epoxy potting (patent pending) comprises the
encoder bottom. Due to this unique sealing, the HR-E LCD exceeds
all applicable requirements of AWWA Standard C706 and C707.
Wire Connections: The HR-E LCD encoder is available with an
in-line connector for easy connection and installation to AMR/AMI
endpoints. It is also available with a flying lead for a field splice
connection, or fully prewired to an AMR/AMI endpoint.
Operating Characteristics: The HR-E LCD encoder is shipped in
storage mode so a meter status alarm is not triggered. In storage
mode, the meter model screen is displayed. Upon sensing two
revolutions of the meter magnet, the encoder goes into normal
operation mode. The display then automatically toggles between
these four modes:
• 9-digit consumption displays for 30 seconds.
• 6-digit consumption (segmented leak detector in this mode)
displays for 20 seconds.
• Rate of flow displays for 5 seconds.
• Meter model displays for 5 seconds.
DIMENSIONAL DRAWINGS
Figure 1: Top view
MEASUREMENT RESOLUTION
The electronic encoder output resolution of the HR-E LCD is as
noted below.
Recordall
Disc Series
LP 5/8", 5/8 x 3/4" 0.01 0.001 0.0001
M25 5/8", 5/8 x 3/4" 0.01 0.001 0.0001
M35 3/4" 0.01 0.001 0.0001
M40 1" 0.01 0.001 0.0001
M55 1" 0.01 0.001 0.0001
M70 1" 0.01 0.001 0.0001
M120 1-1/2" 0.1 0.01 0.001
M170 2" 0.1 0.01 0.001
Recordall
Turbo
Series
T160 1-1/2" 0.1 0.01 0.001
T200 2" 0.1 0.01 0.001
T450 3" 0.1 0.01 0.001
T1000 4" 0.1 0.01 0.001
T2000 6" 1 0.1 0.01
T3500 8" 1 0.1 0.01
T5500 10" 1 0.1 0.01
T6200 12" 10 1 0.01
T6600 16" 10 1 0.01
T10000 20" 10 1 0.01
Recordall
Compound Series
High Side T200 2" 0.1 0.01 0.001
Low Side M25 2" 0.01 0.001 0.0001
High Side T450 3" 0.1 0.01 0.001
Low Side M25 3" 0.01 0.001 0.0001
High Side T1000 4" 0.1 0.01 0.001
Low side M35 4" 0.01 0.001 0.0001
High Side T2000 6" 1 0.1 0.01
Low Side M35 6" 0.01 0.001 0.0001
High Side T3500 8" 1 0.1 0.01
Low side M120 8" 0.1 0.01 0.001
Size
Size
9-dial encoder
output (gal)
9-dial encoder
output (gal)
9-dial encoder
Size
output (gal)
9-dial encoder
output (ft3)
9-dial encoder
output (ft3)
9-dial encoder
output (ft
OTE:N For Fire Service Meters and Assemblies, please refer to
appropriate Disc and TSM information provided above.
9-dial
encoder
output (m3)
9-dial encoder
output (m3)
9-dial
encoder
3
)
output (m3)
Figure 2: Front view
Figure 3: Left side view
Making Water Visible®
GALAXY, Making Water Visible, ORION and Recordall are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their
respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without
notice, except to the extent an outstanding contractual obligation exists. © 2015 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400
México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882
Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0
Europe, Middle East Branch Office | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503
Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411
Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01
Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836
China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412 Legacy Document Number: LCD-T-01