Bacharach True Spot User Manual

®
True Spot
Smoke Test Kit
The Bacharach True Spot Smoke Test Kit determines efficient combustion and is internationally recognized as the standard method for evaluating smoke density in the flue gases from distillate fuels. Too much smoke is one of the most common causes of excessive fuel usage and expensive service requirements. That is precisely why the smoke test is an indispensable part of any oil burner service job; and with the True Spot, an accurate smoke reading takes less than a minute.
The True Spot smoke test method has long been recognized as the accepted standard for oil burner smoke tests. It is used by Underwriters’ Laboratories in approval testing of oil burners; and it is the test method specified in the Installation Standards of the National Oil Fuel Institute by U.S. Department of Commerce, Testing materials (D2156-65), and German Standard DIN 51-402.
ORDERING INFORMATION
PART NO. DESCRIPTION
21-7006 True Spot Smoke Test Kit
21-7012 Test Pump
21-0018 Smoke Scale
21-0040 Lubricant
21-0019 Filter Paper Sheets (40 strips)*
*Note: A spare kit containing replacement scale and
filter paper is available; order item # 21-0020.
CO Indicator Kits
Carbon Monoxide Indicator
Monoxor®Indicator Monoxor Detector
A quick, easy to use instrument that measures carbon monoxide by simply drawing an air sample through a chemical reagent in a glass indicator tube.
If carbon monoxide is present, a stain appears in the indicator tube; the length of the stain is measured against a built-in scale to determine the CO percentage or parts per million (ppm).
ORDERING INFORMATION
ITEM SAMPLE PUMP TUBES TUBE FLUE GAS
NO. ITEMS RANGE
19-0240 Monoxor 0-0.2% 19-0242 19-0014 19-5010 19-0001 None 19-0241 Indicators 0-0.5% 19-0243 19-0015 19-5015 19-0001 None
19-0245 Monoxor 0-0.2% 19-0242 19-0014 19-5010 19-0001 11-7045 19-0244 Gas Test Kit 0-0.5% 19-0243 19-0015 19-5015 19-0001 11-7045
19-7021 Monoxor Detector including pump, one carton of 12 indicator tubes (19-5002) and a carrying case
(Incl. Scale & Orifice A)
The Monoxor Detector is also fast and simple to operate. An air sample is drawn through a detector tube containing an indicating gel; if a stain forms after one pump stroke, the CO concentration is 300 ppm or higher. If it appears after two strokes, the concentration is 100 to 300 ppm. If no stain appears, the concentration is less than 100 ppm.
SCALE
(12 per carton)
CAPS (6)
SAMPLING ASSEMBLY
1.800.736.4666 BACHARACH
19-5005 Monoxor Detector Kit (19-7021), as above, plus Flue Gas Sampling Assembly (11-7056)