The Measurabte Difference
DUAL PURPOSE
LEAK DETECTOR
Refriyeronrs R Combustibles
Detects both refrigerants and combustible
gases (with respective sensor installed)
Audible Indicator with Mute Feature
Sensor set at the tip for pinpoint accuracy
and instantaneous response time
Sensors are interchanged quickly and easily
Flashing probe tip
Dual LED displays
Low Battery Indicator
Optional boot and tiashlight
The lnforniailt~^
Dual Purpose Leak Detector
The Informant™ 2 leak detector allows pinpoint detection of both refrigerant and combustible gas leaks
with the same instrument.
It's unique combination of state-of-the-art patented sensor technology, advanced software design and
microprocessor-controlled circuitry offers you unmatched precision coupled with tremendous speed.
The Informant™ 2 utilizes patented semiconductor sensor technology to detect combustible gases and
patented heated diode sensor technology to detect refrigerants.
Swap sensor tips within seconds and never worry about adjusting sensitivity levels - it's taken care of
automatically - even where high levels of background vapors or refrigerants are present. The refrigerant
sensor tip is hnely tapered to 0.2" diameter - so you can get in between coils and httings, gaining access
to hard to reach areas.
The Informant™ 2 leak detector features an audible indicator with a mute option coupled with sequential LEDs to monitor increasing concentrations of
refrigerant or combustible gases. Dual bar graph displays offer visual conhrmation no matter what position the instrument is in. And, a hashing light at the tip
of the probe helps to visually dehne your sampling location.
Phone: 1-800-736-4666 Fax: 1-724-334-5001 Email: help@bacharach-inc.com Website: www.bacharach-inc.com
Leah Detector
Headquarters: 621 HuntValley Circle, New Kensington, PA 15068 U.S.A.

SPECIFICATIONS
Sensing Elements
Refrigerant
Com bustible
Refrigerants D etected All CFC, HCFC and HFC refrigerants including: R-12, R-22,
Com bustible G ases
Detected
Alarm Sensitivity
Refrigerant
Com bustible
Alarm Types Audible, dual visual LED's and flashing probe tip
Power Source Four (4) AA disposable alkaline batteries included
Warm-up Time 10 seconds
Response Time
Refrigerant
Com bustible
Battery Life 4-5 hours, under typical intermittent operation
Probe 20" (50.8 cm) maximum length, fully extended; 3" (7.62 cm)
Size 1.75"W x 9.62"L x 2.25"H (4.45 cm x 24.43 cm x 5.72 cm)
Weight 0.86 lbs. (0.39 kg) with batteries
Agency Approvals
Refrigerant
Com bustible
Warranty One year, includin g sensors
Heated Diode - U.S. Patent No. 5,932,176
Patented semiconductor type. Five year typical life. Plug-in
replacement
R-123. R-134a and blends R-404A, R-408A, R-409A and
R-410A (i.e., any refrigerant containing Chlorine, Flourine or
Bromine gas)
All combustible gases and vapors
Less than 0.25 oz/yr of R-134a (hardest to detect refrigerant)
Minimum 50ppm (Methane)
Instantaneous
Instantaneous
if wrapped around instrument. Includes LED indicator
UL listed in accordance with SAE J1627
MET Lab certified to UL 913, intrinsically safe for use in
Class1, Division 1, Group D hazardous areas
Distributed By:
Technical Training for Heating & Cooling
TUV m
*lUKi[H[HrStWCt
Bacharach is a registered trademark of Bacharach, Inc. Informant 2 is a trademark of Bacharach, Inc.
©June, 2005, Bacharach, Inc., all rights reserved. All information is subject to verification.
Product Bulletin-4170 06/05 3M BI
Printed in U.S.A.
ISO 9001:2000
C€
Features
&
Benefits
Lightweight and ergonomically designed
Microprocessor controlled for accuracy and reliability
Sensitivity is adjusted automatically
Hydrophobic filter prevents moisture contamination
Rugged rubber boot holds flashlight (optional)
Sequential flashing probe tip, dual LED displays and loud tick
rate indicates relative concentration levels
Lifetime warranty available
ORDERING INFORMATION
PART NO. DESCRIPTION
19-8038 Informant 2 Contractor Kit. Instrument comes w ith refrigerant
and combustible gas sensors, color-coded sensor tips, instruction
manual, 4 AA batteries and a hard carrying case.
19-8042 Dual Refrigeran^Combustib le Informant 2 Detector Kit. Instrument
comes with refrigerant and combustible gas sensors, color-coded
sensor tips, instruction manual, 4 AA batteries, 5 filters and a
custom soft carrying case.
19-8045 Dual Deluxe Refrigeran^Combustible Inform ant 2 Detector Kit.
Instrum ent comes with refrigerant and combustible gas sensors,
color-coded probe tips, protective rubber boot, flashlight, instruction
manual, 6 AA batteries and 5 filters, all packaged in a hard carrying
case.
19-8040 Refrigerant Only Informant 2 D etector Kit. Instrument comes with
refrigerant sensor, color-coded probe tip, instruction m anual, 4 A A
batteries, 5 filters and a custom carrying case.
19-8037 Deluxe Upgrade Kit. Includes protective rubber boot, flashlight, 2
AA batterie s and a hard carrying case.
19-8047 Combustible Gas Upgrade Kit. To upgrade a refrigerant only
Informant 2 to a dual sensing instrument. Includes combustible gas
sensor, color-coded probe tip and 5 filters
19-0499 Replacement com bustible sensor
19-0510 Replacement refrigerant sensor
19-0509 Replacement filters (5-pack)
Headquarters: 621 Hunt Valley Circle
New Kensington, PA 15068
Phone: 1-800-736-4666 Website: