Bacharach SF6, R-600a User Manual

H25-IR
Leak Detection
Utilizes Infrared Technology for Detection
ensures long sensor life and high accuracy
Fewer False Alarms
use of infrared technology enables response to refrigerants only
Fast Response Time
responds to leaks in less than 1 second
High Sensitivity
detects leaks as small as 0.01 oz/yr
Internal Leak Source
enables calibrations to be made quickly and easily
• Wide Assortment of Probe Options provides flexibility in your application
2 Year Warranty
H25-IR
Industrial Refrigerant Leak Detector
The H25-IR is an industrial leak detector used for low-level detection and leak rate quantification of CFCs, HFCs, HCFCs, and halogen gas compounds that are used in air conditioning and refrigeration equipment, fire suppression systems, and various other residential, commercial and industrial apparatus. The instrument can be used to locate and quantify leaks as well as log and totalize the entire group of leaks in a system to ensure quality assurance compliance. The unit is capable of detecting 29 of the most commonly used refrigerants and halogen gas compounds. Additional gas-specific models are available for R-600a and SF6.
Headquarters: 621 Hunt Valley Circle, New Kensington, PA 15068 U.S.A.
Phone: 1-800-736-4666 Fax: 1-724-334-5001 Email: help@bacharach-inc.com Website: www.bacharach-inc.com
SPECIFICATIONS
Gases Measured •CFC, HFC, and HCFC unit: R-11, R-12, R-22,
R-23, R-113, R-114, R-123, R-124, R-134a, R-227, R-236fa, R-401A, R-402A, R-402B, R-404A, R-407A, R-407C, R-408A, R-409A, R-410A, R-500, R-502, R-503, R-507, R-508B, H-1211, H-1301, H-2402, N-1230
•Gas specific unit for R-600a (isobutane)
•Gas specific unit for SF6 (sulfur hexafluoride)
Sensor Infrared
Measurement Units oz/yr, g/yr, mL/s, PaM3/s, ppm
Measurement Range 0.00 - 5.00 oz/yr
Warm-Up Time 2 minutes
Probe and Hose •8” (20.3 cm) and 15” (38.1cm) flexible probes included
•6’ (1.8 m) hose, 12’ (3.6 m), 15’ (4.6m), and 18’ (5.5m) hoses available
Operating Modes Search - detects presence and location of gas leaks
Measure - calculates and displays leak rate
Response Time Less than 1 second (with 6’ probe hose)
Sensitivity 0.01 oz/yr
Temperature Drift ±0.8% of reading per °C
Calibration Internal: calibration performed using the unit’s built-in internal
leak source External: calibration performed using a customer supplied leak source of known gas type and leak rate
Power 100 to 240 VAC, 50/60 Hz
Power Consumption 15 Watts
Dimensions 4”H x 10.75”W x 15”D (10.2 cm x 27.3 cm x 38.1 cm)
Operating Temperature Range 32 to 122°F (0 to 50°C)
Operating Humidity Range 5 to 90% RH, non condensing
Storage Temperature Range –4 to 122°F (–20 to 50°C)
Weight 18 lbs. (8.2 kg)
Warranty Two year full warranty on instrument
Ordering Information
The H25-IR instrument, along with its probe type and hose length, is ordered by specifying 3 codes. The codes must be listed in the following sequence:
Code A Model Name Code B Gas Type Code C Probe Type and Hose Length
For example: To order an H25-IR that detects CFC type refrigerants; a Standard Probe with LED & Button; and a 6 foot hose,
H25-IR Instrument Probe Type & Hose Length Ordering Information
CODE DESCRIPTION
Code A H25IR Infrared Gas Leak Dectector Code B CFC, HFC, HCFC & Halogen Gases R-600a SF6 Code C Standard Probe, 6 foot Hose Standard Probe, 12 foot Hose
Standard Probe, LED & Button, 6 foot Hose Standard Probe, LED & Button, 12 foot Hose Smart Probe, 6 foot Hose Smart Probe, 12 foot Hose Standard Probe, 15 foot Hose Standard Probe, 18 foot Hose Standard Probe, LED & Button, 15 foot Hose Standard Probe, LED & Button, 18 foot Hose Smart Probe, 15 foot Hose Smart Probe, 18 foot Hose
-10
-11
-12
-1
-2
-3
-1
-2
-3
-4
-5
-6
-7
-8
-9
you would order an H25IR-1-3
Probes
Standard Probe
Contains no buttons or visual feedback.
Standard Standard Probe Smart Probe LED & Button Probe
Bacharach is a registered trademark of Bacharach, Inc. ©February, 2007, Bacharach, Inc., all rights reserved. All Information is subject to verification. Product Bulletin-4168 03/07 2 M PR T
Printed in U.S.A.
Standard Probe, LED & Button
Contains a button that can be configured to either zero the unit or switch between the instrument’s search and measure modes. Also contains an LED that provides visual feedback. The LED can be configured to blink with increasing frequency as the measured leak rate increases or light steadily once a user defined threshold is reached.
Smart Probe
Contains an LCD display that shows the current leak rate. Also contains an LED that can be configured for operation just as with the Standard Probe, LED & Button. The probe also has a keypad that is identical to the one on the H25-IR’s front panel, enabling all of the instrument’s functions, setups and features to be accessed via the probe.
Phone: 1-800-736-4666 Website: www.bacharach-inc.com
Distributed By:
Technical Training for Heating & Cooling
Headquarters: 621 Hunt Valley Circle
New Kensington, PA 15068