c
e
t
e
D
s
a
G
A
I
M
t
w
o
1
r
0
/
0
M
o
n
i
Features & Benefits:
Real-time continuous gas detection that’s
scalable, reliable and affordable
Ideal for commercial applications such as
hotel rooms, apartments, dorms, hospitals,
restaurant kitchens or battery charging rooms
Detects refrigerants (at ≥1,000 or ≥10,000 ppm),
TVOCs (at ≥1,000 ppm), combustible gases and
hydrocarbons (at ≥5,000 ppm)
Fast-responding, long-life sensors
t
o
r
Integrated visual LED and audible alarms
Two onboard relays to activate shut-off valves,
exhaust fans, or connect to a BMS or fire panel
Remote sensor with aesthetic faceplate available for
discreet monitoring in decorative interiors
Remote sensor
aesthetic faceplate
(brushed steel finish)
IAM-100 Standard Housing
Economical Standalone or System Wide Monitoring
The IAM-100 Gas Monitor from Bacharach offers exceptional continuos monitoring performance and flexibility at an
economical price. By itself, or integrated into a comprehensive detection system, the IAM-100 is a scalable solution
for detecting a variety of refrigerants, combustible gases and VOC gas leaks at the lowest possible cost.
Onboard LEDs illuminate when the sensor is in an alarm state while the
unit’s audible alarm alerts personnel in the area that levels have exceeded
the desired limit. The audible alarm can be muted with the onboard
silence switch. Integrated dual relays enable the IAM-100 to shut-off
refrigerant or propane supply lines while the second relay can be used as
a connection to a building BMS or BAS system.
The IAM-100 is an alarm threshold device. When the range of the
sensor is exceeded, the detector will go into alarm. For example, a unit
with a 1,000 ppm R-410a sensor will activate its alarm when the detected
Optional IAM-Controller
refrigerant meets or exceeds 1,000 ppm.
1 - 800- 736- 4666 | 724- 334- 5000 | www.MyBacharach.com | help@M y Bach a r ach.c o m
IAM-100 Technical Specifications
Power Supply:
Power Monitoring:
Visual Alarm:
Audible Alarm:
Fault Monitoring:
Relays:
Alarm Delay:
IP Rating:
Sensor Type / Life:
Temperature Range:
Humidity Range:
Calibration:
Warm-up Delay:
Approvals:
Dimensions & Weight:
(enclosure types)
110 VAC/60 Hz or 220 VAC/50 Hz; 11W max.
Green LED
Red LED
Internal buzzer (with onboard mute button)
Yes: (
Red LED On, Green LED Off, Siren Off)
2 Relays:
each rated 1 Amp @ 24 VDC
Selectable: 0, 5, 10 or 15 minutes
IP30
Semiconductor (multi-gas) / 5-8 year life
-
4º to 122ºF
-20º to 50ºC
0-95% Non-condensing
Annual test or calibration recommended.
Refer to manual for sensor specific instructions
5 mins. initially
CE • IEC/EN 61010 • UL/CSA 61010-1
5
.8”x 3.47”x 2.44” • 1lb. 6oz.
147 x 88 x 62mm • 633g
IAM-100 Gas Types & Detection Ranges
Semiconductor Sensor - Threshold Ranges
Refrigerants:
HFCs:
including R-134a, R-410a,
R-404a, R-507, R-407
HCFCs:
including R-22
CFCs:
including R-11
Hydrocarbons:
including Methane,
Natural Gas, Propane
Butane, LPG, Hydrogen
Isobutane
VOCs:
including Acetone,
Chloroform, Ethanol,
Methanol, Methyl and
Methylene Chloride,
Ethyl and Ethylene
Chloride
at ≥1,000 ppm or at ≥10,000 ppm
at ≥1,000 ppm or at ≥10,000 ppm
at ≥1,000 ppm or at ≥10,000 ppm
at ≥5,000 ppm
at ≥1,000 ppm
IAM-Controller Technical Specifications
Power Supply:
Power Monitoring:
Visual Alarm:
Audible Alarm:
Fault Monitoring:
Relays:
IP Rating:
Max Cable Distance:
(controller - transmitter)
Approvals:
Dimensions & Weight:
(enclosure types)
110 VAC/60 Hz or 220 VAC/50 Hz; 11W max.
Green LED
Red LED
External buzzer (with onboard mute button)
Yes: (
Red LED On, Green LED Off, Siren Off)
2 Relays:
each rated 10 Amp @ 110/220 VAC
IP51
300 m (984 ft.);
16-24 AWG
CE • UL/CSA 61010
Standard
IP30 262 x 265 x 84mm • 2.6kg
10.3”x 10.4”x 3.3”• 5lb. 12oz.
IAM-100 Ordering Information
IAM-100 Common Configurations
6201-1107
6201-1143
6201-5107
6201-5143
6202-1107
6202-1143
6202-5107
6202-5143
6201-1103
6201-1113
6201-1101
6201-1105
6201-5114
6201-5119
6201-5120
6201-5121
6201-5151
6202-5114
6202-5119
6202-5120
6202-5121
6202-5151
R-410a | 1,000 ppm • Standard Housing • 110 VAC powered
R-410a | 10,000 ppm • Standard Housing • 110 VAC powered
R-410a | 1,000 ppm • Remote w/faceplate • 110 VAC powered
R-410a | 10,000 ppm • Remote w/faceplate • 110 VAC powered
R-410a | 1,000 ppm • Standard Housing • 220 VAC powered
R-410a | 10,000 ppm • Standard Housing • 220 VAC powered
R-410a | 1,000 ppm • Remote w/faceplate • 220 VAC powered
R-410a | 10,000 ppm • Remote w/faceplate • 220 VAC powered
R-404a | 1,000 ppm • Standard Housing • 110 VAC powered
R-290 | 5,000 ppm • Standard Housing • 110 VAC powered
R-134a | 1,000 ppm • Standard Housing • 110 VAC powered
R-407a | 1,000 ppm • Standard Housing • 110 VAC powered
CH4 | 5,000 ppm • Remote w/faceplate • 110 VAC powered
H2 | 5,000 ppm • Remote w/faceplate • 110 VAC powered
Ethylene| 5,000 ppm • Remote w/faceplate • 110 VAC powered
VOC | 1,000 ppm • Remote w/faceplate • 110 VAC powered
LPG | 5,000 ppm • Remote w/faceplate • 110 VAC powered
CH4 | 5,000 ppm • Remote w/faceplate • 220 VAC powered
H2 | 5,000 ppm • Remote w/faceplate • 220 VAC powered
Ethylene| 5,000 ppm • Remote w/faceplate • 220 VAC powered
VOC | 1,000 ppm • Remote w/faceplate • 220 VAC powered
LPG | 5,000 ppm • Remote w/faceplate • 220 VAC powered
IAM-Controller Ordering Information
IAM-Controller Options
6700-0100
6700-0101
110 VAC powered
220 VAC powered
BACHARACH IS A U.S.
BASED MANUFACTURER
Distributed By:
©2014, Bacharach, Inc., all rights reserved. All information is subject to verification.
January 2014 - REV. 0 Printed in U.S.A.