Features & Benefits:
Real-time continuous gas detection that’s scalable, reliable and affordable
Ideal for commercial applications such as hotel rooms, apartments, dorms, hospitals, restaurant kitchens or battery charging rooms
Detects refrigerants (at 1,000 or 10,000 ppm), TVOCs (at 1,000 ppm), combustible gases and hydrocarbons (at 5,000 ppm)
Fast-responding, long-life sensors
t
o
r
Integrated visual LED and audible alarms
Two onboard relays to activate shut-off valves, exhaust fans, or connect to a BMS or fire panel
Remote sensor with aesthetic faceplate available for discreet monitoring in decorative interiors
Remote sensor
aesthetic faceplate
(brushed steel finish)
IAM-100 Standard Housing
Economical Standalone or System Wide Monitoring
The IAM-100 Gas Monitor from Bacharach offers exceptional continuos monitoring performance and flexibility at an economical price. By itself, or integrated into a comprehensive detection system, the IAM-100 is a scalable solution for detecting a variety of refrigerants, combustible gases and VOC gas leaks at the lowest possible cost.
Onboard LEDs illuminate when the sensor is in an alarm state while the unit’s audible alarm alerts personnel in the area that levels have exceeded the desired limit. The audible alarm can be muted with the onboard silence switch. Integrated dual relays enable the IAM-100 to shut-off refrigerant or propane supply lines while the second relay can be used as a connection to a building BMS or BAS system.
The IAM-100 is an alarm threshold device. When the range of the sensor is exceeded, the detector will go into alarm. For example, a unit with a 1,000 ppm R-410a sensor will activate its alarm when the detected
Optional IAM-Controller
refrigerant meets or exceeds 1,000 ppm.
1 - 800- 736- 4666 | 724- 334- 5000 | www.MyBacharach.com | help@M y Bach a r ach.c o m
IAM-100 Technical Specifications
Power Supply: Power Monitoring: Visual Alarm: Audible Alarm: Fault Monitoring: Relays:
Alarm Delay: IP Rating: Sensor Type / Life: Temperature Range:
Humidity Range: Calibration:
Warm-up Delay: Approvals: Dimensions & Weight:
(enclosure types)
110 VAC/60 Hz or 220 VAC/50 Hz; 11W max. Green LED Red LED Internal buzzer (with onboard mute button) Yes: (
Red LED On, Green LED Off, Siren Off)
2 Relays: each rated 1 Amp @ 24 VDC
Selectable: 0, 5, 10 or 15 minutes IP30 Semiconductor (multi-gas) / 5-8 year life
-
4º to 122ºF
-20º to 50ºC 0-95% Non-condensing Annual test or calibration recommended.
Refer to manual for sensor specific instructions 5 mins. initially
CE IEC/EN 61010 UL/CSA 61010-1 5
.8”x 3.47”x 2.44” 1lb. 6oz.
147 x 88 x 62mm 633g
IAM-100 Gas Types & Detection Ranges
Semiconductor Sensor - Threshold Ranges
Refrigerants: HFCs:
including R-134a, R-410a, R-404a, R-507, R-407
HCFCs:
including R-22
CFCs:
including R-11
Hydrocarbons:
including Methane, Natural Gas, Propane Butane, LPG, Hydrogen Isobutane
VOCs:
including Acetone, Chloroform, Ethanol, Methanol, Methyl and Methylene Chloride, Ethyl and Ethylene Chloride
at ≥1,000 ppm or at 10,000 ppm
at ≥1,000 ppm or at 10,000 ppm
at ≥1,000 ppm or at 10,000 ppm
at ≥5,000 ppm
at ≥1,000 ppm
IAM-Controller Technical Specifications
Power Supply: Power Monitoring: Visual Alarm: Audible Alarm: Fault Monitoring: Relays:
IP Rating: Max Cable Distance:
(controller - transmitter)
Approvals: Dimensions & Weight:
(enclosure types)
110 VAC/60 Hz or 220 VAC/50 Hz; 11W max. Green LED Red LED External buzzer (with onboard mute button) Yes: (
Red LED On, Green LED Off, Siren Off)
2 Relays: each rated 10 Amp @ 110/220 VAC
IP51 300 m (984 ft.);
16-24 AWG
CE UL/CSA 61010 Standard
IP30 262 x 265 x 84mm 2.6kg
10.3”x 10.4”x 3.3” 5lb. 12oz.
IAM-100 Ordering Information
IAM-100 Common Configurations
6201-1107 6201-1143 6201-5107 6201-5143 6202-1107 6202-1143 6202-5107 6202-5143 6201-1103 6201-1113 6201-1101 6201-1105 6201-5114 6201-5119 6201-5120 6201-5121 6201-5151 6202-5114 6202-5119 6202-5120 6202-5121 6202-5151
R-410a | 1,000 ppm Standard Housing 110 VAC powered R-410a | 10,000 ppm Standard Housing 110 VAC powered R-410a | 1,000 ppm Remote w/faceplate 110 VAC powered R-410a | 10,000 ppm Remote w/faceplate 110 VAC powered R-410a | 1,000 ppm Standard Housing 220 VAC powered R-410a | 10,000 ppm Standard Housing 220 VAC powered R-410a | 1,000 ppm Remote w/faceplate 220 VAC powered R-410a | 10,000 ppm Remote w/faceplate 220 VAC powered R-404a | 1,000 ppm Standard Housing 110 VAC powered R-290 | 5,000 ppm Standard Housing 110 VAC powered R-134a | 1,000 ppm Standard Housing 110 VAC powered R-407a | 1,000 ppm Standard Housing 110 VAC powered CH4 | 5,000 ppm Remote w/faceplate 110 VAC powered H2 | 5,000 ppm Remote w/faceplate 110 VAC powered Ethylene| 5,000 ppm Remote w/faceplate 110 VAC powered VOC | 1,000 ppm Remote w/faceplate 110 VAC powered LPG | 5,000 ppm Remote w/faceplate 110 VAC powered CH4 | 5,000 ppm Remote w/faceplate 220 VAC powered H2 | 5,000 ppm Remote w/faceplate 220 VAC powered Ethylene| 5,000 ppm Remote w/faceplate 220 VAC powered VOC | 1,000 ppm Remote w/faceplate 220 VAC powered LPG | 5,000 ppm Remote w/faceplate 220 VAC powered
IAM-Controller Ordering Information
IAM-Controller Options
6700-0100 6700-0101
110 VAC powered 220 VAC powered
BACHARACH IS A U.S. BASED MANUFACTURER
Distributed By:
©2014, Bacharach, Inc., all rights reserved. All information is subject to verification.