AXIS 243Q Blade Installation Guide Page 3

AXIS 243Q Blade
Installation Guide
This installation guide provides instructions for installing the AXIS 243Q Blade Video Server on your network. For all other aspects of using the product, please see the User’s Manual, available on the CD included in this package, or from www.axis.com/techsup
Important!
• To mount the hardware in the AXIS 291 1U Video Server Rack, please see the Installation Guide for the server rack
• This product must be used in compliance with local laws and regulations.

Installation steps

1. Check the package contents against the list below.
2. Hardware overview. See page 4.
3. Assign an IP address. See page 6.
4. Set the password. See page 7.

Package contents

ENGLISH
ENGLISH
Item Models/variants/notes
Video server AXIS 243Q Blade CD AXIS Network Video Product CD, including product documentation, installa-
tion tools and other software
Printed Materials AXIS 243Q Blade Installation Guide (this document)
Axis Warranty Document Extra serial number label
Please contact your dealer if anything is missing or damaged.
Page 4 AXIS 243Q Blade Installation Guide

Hardware overview

AXIS 243Q Blade Video Server
DIP Switches - Each video input has a corresponding line termination DIP switch. Axis blade video servers are supplied with the line termination enabled for each input; that is, with the DIP switches set to ON (down position).
To connect the video input in parallel with other equipment, disable the input termination by setting the corresponding DIP switch to OFF (Up posi­tion). Failure to do so may affect the image quality nega­tively.
Bus Connector - This is the physical interface to the video server rack, providing power, network and the I/O terminal connector.
Control Button - This button is used to reset the video server to the factory default settings. See page 9.
Video Inputs - The AXIS 243Q Blade supports 4 video sources (VIDEO 1 - VIDEO 4). Each video input is terminated using a coax/BNC connector. Physical connections made using 75 Ohm coaxial video cable have a recommended maximum length of 800 feet (250 meters).
DIP Switches
Serial number label
Bus Connector
LED Indicators
Video inputs 1-4
Control button
AXIS 243Q Blade Installation Guide Page 5
LED Indicators
Network
Status
Power
Green Steady green - no network activity
Flashes green - network activity Green Steady green - normal operation Red One flash - one or more units starting up
Two flashes - a unit is resetting to factory default settings
Steady red - hardware error on one or more units Green/red Flashes for no connection to AXIS Internet Dynamic DNS Service Green Normal operation Green/Amber Flashes for unit upgrade
AXIS 291 1U Video Server Rack
Power Connector
I/O Terminal Connector 3
I/O Terminal Connector 2
I/O Terminal Connector 1
Power & Network LEDs
Power Connector - Input power: 100-240V AC, 50-60 Hz, 1.9A
I/O Terminal Connector(s) - provides the physical interface to 1 output and 1 input for each
video input. Video input 1 on each blade also provides an RS-485 interface, usually used for connecting Pan Tilt Zoom devices.
Power & Network LEDs - The 10/100 LED flashes red for 10 Mbps, and flashes green for 100 Mbps. The 1000 LED flashes green for 1 Gbps. The power LED shows steady green when the rack has power.
Network Connector - Axis blade video servers are designed for 10/100/1000 Mbps networks and connect via the standard RJ-45 connector.
Network Connector
ENGLISH
ENGLISH
Page 6 AXIS 243Q Blade Installation Guide

Assign an IP address

To make it accessible on the network, the AXIS 243Q Blade must be assigned four IP addresses, one for each video input.
AXIS Camera Management
AXIS Camera Management can automatically find and assign IP addresses, show connection status, and manage firmware upgrades for multiple Axis video products.
Automatic assignment of IP addresses
AXIS Camera Management speeds up the process of assigning IP addresses to multiple devices, by suggesting IP addresses from a specified range.
1. Check that the AXIS 243Q Blade is connected to the network and that power has been applied.
2. Start AXIS Camera Management. The AXIS 243Q Blade appears in the window, with one entry for each video input. These are shown as AXIS 243Q(1) Blade, AXIS 243Q(2) Blade, AXIS 243Q(3) Blade, and AXIS 243Q(4) Blade. Double-click an entry to open the home page for that video input.
3. See page 7 for instructions on how to set the password.
Changing IP addresses
1. To change IP addresses, select the devices you wish to configure and click the Assign IP button.
2. Select Obtain IP addresses automatically (DHCP), click the Update button and the program will search in the specified range and suggest an IP address for each device.
-or­Enter the range of IP addresses, the subnet mask and default router that devices can use and click the Update button.
AXIS 243Q Blade Installation Guide Page 7

Set the password

When accessing the AXIS 243Q Blade for the first time, the ‘Configure Root Password’ dialog will be displayed.
1. Enter a password and then re-enter it, to confirm the spelling. Click OK.
2. Enter the user name root in the ‘Enter Network Password’ dialog. Note: The default administrator user name root cannot be deleted.
3. Enter the password as set above, and click OK. If the password is lost, the AXIS 243Q Blade must be reset to the factory default settings. See page 9.
4. If required, click Yes to install AMC (AXIS Media Control), which allows viewing of the video stream in Internet Explorer. You will need administrator rights on the computer to do this.
The Live View page of the AXIS 243Q Blade is displayed, with links to the Setup tools, which allow you to customize the video server.
AXIS 243Q Blade User’s Manual
For more information on how to use and configure the video server on your network, please refer to the AXIS 243Q Blade User’s Manual, available on the CD supplied with this product, or from the Axis Web site at www.axis.com
ENGLISH
ENGLISH
Page 8 AXIS 243Q Blade Installation Guide

Other methods of setting the IP address

The table below shows the other methods available for setting or discovering IP addresses. All methods are enabled by default, and all can be disabled.
UPnP™
Bonjour
AXIS Dynamic DNS Service
ARP/Ping
View DHCP server admin pages
Use in operating system
Windows When enabled on your computer, the video server is automati-
MAC OSX (10.4 or later)
All A free service from Axis that allows you to quickly and simply
All See below. The command must be issued within 2 minutes of
All To view the admin pages for the network DHCP server, see the
Notes
cally detected and added to “My Network Places.”
Applicable to browsers with support for Bonjour. Navigate to the Bonjour bookmark in your browser (e.g. Safari) and click on the link to access the video server’s web pages.
install your video server. Requires an Internet connection with no HTTP proxy. See www.axiscam.net for more information.
connecting power to the video server.
server’s own documentation.
Set the IP address with ARP/Ping
1. Acquire 4 IP addresses on the same network segment your computer is connected to.
2. Locate the 4 serial numbers (S/N) on the included label.
3. Open a command prompt on your computer and enter the following commands:
Windows syntax Windows example
arp -s <IP Address> <Serial Number> ping -l 408 -t <IP Address>
UNIX/Linux/Mac syntax UNIX/Linux/Mac example
arp -s <IP Address> <Serial Number> temp ping -s 408 <IP Address>
arp -s 192.168.0.125 00-40-8c-18-10-00 ping -l 408 -t 192.168.0.125
arp -s 192.168.0.125 00:40:8c:18:10:00 temp ping -s 408 192.168.0.125
4. Check that the network cable is connected and then start/restart the video server, by disconnecting and reconnecting power.
5. When you see ‘Reply from 192.168.0.125: ...’ or similar, press Ctrl+C.
6. Repeat steps 3, 4 and 5 for the remaining video inputs.
7. In your browser, type in http://<IP address> in the Location/Address field and press Enter on your keyboard.
Notes:
• To open a command prompt in Windows: from the Start menu, select Run... and type cmd. Click OK.
• To use the ARP command on a Mac OS X, use the Terminal utility in Application > Utilities.
AXIS 243Q Blade Installation Guide Page 9

Resetting to the Factory Default Settings

This will reset all the parameters in all 4 units (including all four IP addresses) to the factory default settings.
1. Disconnect power.
2. Press and hold the Control button and reconnect power.
3. Release the button when the Status Indicator displays red
(which may take up to 15 seconds). When the Status Indicator changes to Green (which may take up to 1 minute), the process is complete and the unit 4 has been reset.
4. Re-assign the IP addresses, using one of the methods described in this document.
To reset an individual unit to the original factory default settings, use the button provided in that unit’s web interface. For more information, please see the online help.
LED Indicators
Control button

Further information

The user’s manual is available from the Axis Web site at www.axis.com or from the Axis Network Video Product CD supplied with this product.
ENGLISH
ENGLISH
Tip!
Visit www.axis.com/techsup to check if there is updated firmware available for your AXIS 243Q Blade. To see the currently installed firmware version, see the Basic Configuration web page in the product’s Setup tools.
Guide d'installation AXIS 243Q Blade Page 11
AXIS 243Q Blade
Guide d'installation
Ce Guide d'installation vous explique comment installer le Serveur vidéo AXIS 243Q Blade sur votre réseau. Pour d'autres informations sur l'utilisation de ce produit, consultez le Manuel de l'utilisateur, disponible sur le CD fourni ou sur www.axis.com/techsup.
Important !
• Pour fixer le matériel dans la baie de serveur vidéo 1U AXIS 291, reportez-vous au Guide d'installation de la baie du serveur.
• Ce produit doit être utilisé conformément aux lois et dispositions locales en vigueur.
FRANÇAIS
FRANÇAIS

Étapes de l'installation

1. Vérifiez le contenu de la livraison à l'aide de la liste ci-dessous.
2. Présentation du matériel. Reportez-vous à la page 12.
3. Attribution d'une adresse IP. Reportez-vous à la page 14.
4. Définissez le mot de passe. Reportez-vous à la page 15.

Contenu de l'emballage

Article Modèles/variantes/remarques
Serveur vidéo AXIS 243Q Blade CD CD “AXIS Network Video Product” avec la documentation du produit, les outils
d'installation et d'autres logiciels
Documentation imprimée AXIS 243Q Blade Guide d'installation (le présent document)
Document de garantie d'Axis Etiquette du numéro de série supplementaire
Contactez votre revendeur si un élément est absent ou endommagé.
FRANCAIS
Page 12 Guide d'installation AXIS 243Q Blade

Présentation du matériel

Serveur vidéo AXIS 243Q Blade
Interrupteurs DIP - À chaque entrée vidéo correspond un interrupteur DIP de terminaison de ligne. Sur les serveurs vidéo Axis Blade fournis, la terminaison de ligne de chaque entrée est activée. Autrement dit, les interrupteurs DIP sont en position ON (vers le bas).
Pour connecter l'entrée vidéo en parallèle avec un autre équipement, vous devez désactiver la terminaison d'entrée en mettant l'interrupteur DIP correspondant en position OFF (vers le haut). Si vous ne procédez pas à cette modification, la qualité de l'image peut s'en ressentir.
Connecteur de bus - Cette interface physique avec la baie du serveur vidéo assure l'alimentation en électricité et la mise en réseau. De plus, elle comporte le connecteur pour terminaux E/S.
Interrupteurs DIP
Étiquette du numéro de série
Connecteur de bus
Entrées vidéo 1-4
Témoins DEL
Bouton de commande
Guide d'installation AXIS 243Q Blade Page 13
Bouton de commande - Ce bouton permet de rétablir les paramètres d'usine par défaut du serveur vidéo. Reportez-vous à la page 17.
Entrées vidéo - L'AXIS 243Q Blade prend en charge 4 sources vidéo (VIDÉO 1 à VIDÉO 4). Chaque entrée vidéo se termine par un connecteur coaxial/BNC. La longueur maximale recommandée pour les connexions physiques réalisées à l'aide d'un câble vidéo coaxial de 75 ohms est de 250 mètres.
Témoins DEL
Réseau
État
Alimentation
Vert Reste allumé en vert - Pas d'activité réseau
Clignote en vert - Activité réseau Vert Reste allumé en vert - Fonctionnement normal Rouge Un clignotement - Démarrage d'une ou de plusieurs unités
Deux clignotements - Rétablissement des paramètres d'usine par défaut
d'une unité
Reste allumé en rouge - Erreur matérielle d'une ou de plusieurs unités Vert/Rouge Clignote en l'absence de connexion au service Axis Internet Dynamic DNS
Service Vert Fonctionnement normal Vert/Orange Clignote en cas de mise à niveau de l'unité
Baie de serveur vidéo 1U AXIS 291
Témoins DEL
Connecteur de puissance
Connecteur pour terminaux E/S 3
Connecteur pour terminaux E/S 2
Connecteur pour terminaux E/S 1
d'alimentation et de réseau
Connecteur d'alimentation - Alimentation en entrée : 100-240 Vca, 50-60 Hz, 1,9 A
Connecteur(s) pour terminaux E/S - Fait/Font office d'interface physique pour 1 sortie et 1
entrée par entrée vidéo. L'entrée vidéo 1 de chaque lame fournit également une interface RS­485, généralement utilisée pour la connexion aux périphériques PTZ (Pan Tilt Zoom).
Témoins DEL d'alimentation et de réseau - Le témoin DEL 10/100 clignote en rouge pour les réseaux de 10 Mbit/s et en vert pour ceux de 100 Mbit/s. Le témoin DEL 1000 clignote en vert pour les réseaux de 1 Gbit/s. Le témoin DEL d'alimentation reste allumé en vert si la baie est sous tension.
Connecteur de réseau - Les serveurs vidéo Axis Blade sont conçus pour les réseaux de 10/100/1000 Mbit/s. La connexion s'effectue via le connecteur RJ-45 standard.
Connecteur de réseau
FRANÇAIS
FRANÇAIS
FRANCAIS
Loading...
+ 30 hidden pages