Avycon AIVO-35T User Manual

HD-TVI / Network tester
User’s Manual
AIVO-35T
Thank you for purchasing AIVO-35T All-in-one tester. Please read the manual thoroughly before
Please read theSafety Informationsection in the manual carefully. Please keep the manual in safe place for the future reference. Keep the S/N label for the future RMA purpose. Product without S/N label will be charged for
RNA repair service.
If there is any question or problem using AIVO-35T All-in-one tester, please contact AIVO
technical support.
Content
1. Safety information ----------------------------------------------------------------------------------------------------- 1
2. IP Camera Tester Introduction --------------------------------------------------------------------------------------- 2
2.1 General --------------------------------------------------------------------------------------------------------- 2
2.2 Features -------------------------------------------------------------------------------------------------------- 3
2.3 Function -------------------------------------------------------------------------------------------------------- 5
2.4 Packing list -------------------------------------------------------------------------------------------------- 11
2.5 Function interface ------------------------------------------------------------------------------------------ 12
3. Operation -------------------------------------------------------------------------------------------------------------- 16
3.1 Installing the Battery --------------------------------------------------------------------------------------- 16
3.2 Instrument connection ------------------------------------------------------------------------------------- 17
3.2.1 IP camera connection --------------------------------------------------------------------------- 17
3.2.2 Analog camera connection --------------------------------------------------------------------- 18
3.2.3 HD Coaxial camera connection --------------------------------------------------------------- 18
3.3.1 Video monitor test (PTZ control) ------------------------------------------------------------- 22
3.3.2 Color-bar generator (TV OUT) --------------------------------------------------------------- 31
3.3.3 ONVIF --------------------------------------------------------------------------------------------- 32
3.3.4 IP camera test ------------------------------------------------------------------------------------- 41
3.3.5 TVI camera test ---------------------------------------------------------------------------------- 44
3.3.6 IP address scan ----------------------------------------------------------------------------------- 49
3.3.7 PING Test ----------------------------------------------------------------------------------------- 49
3.3.8 Cable test ------------------------------------------------------------------------------------------ 50
3.3.9 Port finder ----------------------------------------------------------------------------------------- 51
3.3.10 Data monitor ------------------------------------------------------------------------------------ 52
3.3.11 Digital Multi-meter*Optional -------------------------------------------------------- 53
3.3.12 Media Player ------------------------------------------------------------------------------------ 59
3.3.13 Audio player ------------------------------------------------------------------------------------ 60
3.3.14 LED Flashlight --------------------------------------------------------------------------------- 60
3.3.15 POE Voltage Meter -------------------------------------------------------------------------- 62
3.3.16 Calculator ---------------------------------------------------------------------------------------- 62
3.3.17 Browser ------------------------------------------------------------------------------------------ 62
3.3.18 IP camera viewer ------------------------------------------------------------------------------- 63
3.3.19 DC12V power output -------------------------------------------------------------------------- 65
3.3.20 Application tools ------------------------------------------------------------------------------- 66
3.3.21 APPS Tools ------------------------------------------------------------------------------------- 75
3.3.22 System Set --------------------------------------------------------------------------------------- 76
3.3.23 Update -------------------------------------------------------------------------------------------- 79
3.4 DC12V 1A power output --------------------------------------------------------------------------------- 79
3.5 Audio test ---------------------------------------------------------------------------------------------------- 80
4. Specifications --------------------------------------------------------------------------------------------------------- 81
4.1 General Specifications ------------------------------------------------------------------------------------- 81
4.2 Multi-meter specifications -------------------------------------------------------------------------------- 83
4.3 Optical power meter specifications --------------------------------------------------------------------- 86
4.4 Visual fault locator specifications ----------------------------------------------------------------------- 86
1 Safety information
The tester is intended to use in compliance with the local rules of the electrical usage and avoid to apply at the places which are inapplicable for the use of electrics such as hospital, gas station etc.
To prevent the functional decline or failure, the product should not be sprinkled or damped.
The exposed part of the tester should not be touched by the dust and liquid.
During transportation and use, it is highly recommended to avoid the violent collision and vibration
of the tester, lest damaging components and causing failure.
Don’t leave the tester alone while charging and recharging. If the battery is found severely hot, the
tester should be powered off from the electric source at once. The tester should not be charged over 8 hours.
Don’t use the tester where the humidity is high. Once the tester is damp, power off immediately and move away other connected cables.
The tester should not be used in the environment with the flammable gas.
Do not disassemble the instrument since no component inside can be repaired by the user. If the
disassembly is necessary indeed, please contact with the technician of our company.
The instrument should not be used under the environment with strong electromagnetic interference.
Don’t touch the tester with wet hands or waterish things.
Don’t use the detergent to clean and the dry cloth is suggested to use. If the dirt is not easy to
remove, the soft cloth with water or neutral detergent can be used. But the cloth should be tweaked sufficiently.
About Digital Multi-meter
Before using, you must select the right input jack, function and range.
Never exceed the protection limit values indicated in specifications for each range of measurement.
When the tester is linked to a measurement circuit, do not touch unused terminals.
Do not measure voltage if the voltage on the terminals exceeds 660V above earth ground.
At the manual range, when the value scale to be measured is unknown beforehand, set the range
selector at the highest position.
Always be careful when working with voltages above 60V DC or 40V AC, keep fingers behind the probe barriers while measuring.
1
Never connect the meter with any voltage source while the function switch is in the current, resistance, capacitance, diode, continuity, otherwise it will damage the meter.
Never perform capacitance measurements unless the capacitor to be measured has been discharged fully.
Never measure any of resistance, capacitance, diode or continuity measurements on live circuits.
Visual laser sources
When you turn on visual laser sources, please don’t stare at it, or will damage to eyes. When not using it, Please turn it off and cover the protective cap.
2. IP Camera Tester Introduction
2.1 General
The 3.5 inch touch screen IP camera monitor and tester is designed for maintenance and installation of IP cameras and analog cameras as well as other security equipment. The 480x320 resolution enables it to display network HD cameras and analog cameras in high resolution. The unit supports many ONVIF PTZ and analog PTZ control. The combination of touch screen and key buttons make the IP camera tester very user- friendly.
The tester is also a great tool for Ethernet network testing. It can test PoE power voltage, PING, and IP address searching. You can use the blue cable tracer to locate individual connected cables from a bundle of cables. Test LAN cable for proper connection termination. Other functions include LED Flashlight, DC 12V 1A power output and much more. Its portability, user-friendly design and many other functions make the IP tester an essential tool for all installers or technicians.
2
2.2 Features
3.5inch 480×320 touch screen, easy to operate. ONVIF IP camera video testing.
Compatible with H.264/MPEG4/MJPEG IP cameras, such as Dahua, HIKVISION, and ACTI.
Customized service is available.
Built in Wi-Fi: receives video from wireless cameras or ONVIF cameras connected to the
network.
SDI Digital camera image display, record and screen snapshot * Optional
HD CVI camera image display, zoom ,video record and playback ,Coaxial PTZ control and
call camera OSD menu* Optional
HD TVI camera image display, zoom ,video record and playback ,Coaxial PTZ control and
call camera OSD menu
AHD camera image display, zoom ,video record and playback ,Coaxial PTZ control and call
camera OSD menu* Optional
Analog camera video display. Auto adapts and displays the video in NTSC/PAL formats Support more than 30 protocols, such as PELCO-PPELCO-D,SAMSUNG etc PEAK video signal level, SYNC signal level, Color burst Chroma level measurement, test
video signal attenuation* Optional
Video image digital zoom to view the image in greater detail. Snapshot function allows you to save the current image as a JPG file in the SD card. Video recording and playback.
LED Flashlight.
4GB Micro SD card included LCD screen brightness/contrast/color Saturation adjustable Visual fault locator , to test fiber’s bending and breakage* Optional Optical power meter ,test fiber loss and value* Optional Digital Multi-meter , DC and AC voltage measurement, Resistance measurement *
3
Optional
Enhanced Color bar generator: PAL/NTSC multi-system color bar video generator
(Eight-system switchable, transmit/receive eight-system colorful images).
Cable tracer by sending an audio signal, enables the blue cable tracer to find the connected
cable from a bundle of cables.* Optional
Ping test: PING is the most conventional network debugging tool; it is used for testing if the
connected IP camera or other network equipment’s Ethernet port is working normally and the
IP address is correct.
In digital IP surveillance applications, if the IP camera’s IP address is not known; the device
cannot be used. An IP address scan can quickly search for the connected IP camera or other
network device’s IP address
The PoE voltage test can test for PoE voltage when a POE switch is supplying POE power to an
IP camera
TDR cable test, test cable short-circuit and short-circuit* Optional Cable test: Tests LAN cable sequence of wires Support RS485,Rate 600 115200bps adjustable PTZ protocol analysis, control protocol command displays to check RS485 transmission
whether is normal, easy to find the fault device PTZ control. Pan/tilts the P/T unit, zooms in/out the lens, adjusts the focus, aperture and
Sets and the preset position
DC12V 1A output power for cameras Audio input t test. 3.7V 3000mAh,Lithium Ion Polymer Battery can last 10 hours for normal use after charging
for 4-5 hours. Remaining battery charge indicator
“*”Sign means the function Optional
4
2.3 Function
2.3.1 Touch screen and OSD menu
The IP camera tester combines touch screen control and physical buttons. This combination makes the tester very user friendly. The test meter allows you to move the function icons from the tester’s main menu to the APPS tool folder or move them back to customize the main menu
2.3.2 WiFi
With built in WiFi, you can view the video from a wireless camera (ONVIF or customized camera) or
connect to a Wireless network.
2.3.3 IP camera test
The device is designed for ONVIF IP camera testing. It can display the image from an IP camera and change the IP address. The 3.5 inch 480x320 screen display allows the user to view the image with a sufficient screen size.
With the ONVIF tool, you can display the image from an IP camera and use the PTZ functions. Currently the IP camera tester supports more than 70 brands' IP cameras, such as most, ACTi, Dahua, Hikvision, Samsung, Honeywell and many more. OEM service is available. Users can send us the ip camera mobile apps for our engineers try to add the protocol to the tester.
2.3.4 SDI camera test * Optional
SDI digital video surveillance testing, support 720p 60fps / 1080p 30fps / 1080i 60fps digital camera image test and video image zoom, record, screen snapshot, Photo viewer and playback.
2.3.5 CVI camera test* Optional
CVI camera tester, support720p 25,30,50,60fps/1080p 25,30fps,when CVI signal input,HD CVI camera image display, zoom, view photos, video record and playback, Coaxial PTZ control and call up the camera OSD menu.
5
2.3.6 TVI camera test
TVI camera tester support 720p 25,30,50,60fps/1080p 25,30fps, when TVI signal input,HD TVI camera image display, zoom,view photos,video record and playback,Coaxial PTZ control and call up the camera OSD menu.
2.3.7 AHD camera test* Optional
AHD camera tester, support 720p 25,30fps/ 1080p 25,30fps, when AHD signal input, AHD camera image display, zoom ,view photos ,video record and playback ,Coaxial PTZ control and call camera OSD menu.
2.3.8 Analog camera test
Displays an analog camera image on the 3.5 inch 480*320 resolution LCD screen. Supports PAL & NTSC formats. The LCD screen's back light brightness, video image brightness, contrast and color saturation are all adjustable.
2.3.9 Video level meter* Optional
Perform NTSC and PAL video amplitude signal measurements for PEAK to PEAK, SYNC levels and COLOR BURST Chroma level. Video signal PEAK to PEAK level: For NTSC format, the video signal level is 140±15IRE For PAL format, the video signal level is 1000±200mV If the level is too low, it will cause the image to lose quality and limit the distance it will travel over cable. If the level is too high, it will lead to wash out of the image SYNC level: Testing the amplitude of the video sync pulse to verify if the video level is correct. For NTSC format, the SYNC level is 40 ± 5IRE For PAL format, the SYNC level is 300 ± 35mV If the level is too low, it will cause the image to not frame out properly. If the level is too high, it will lead to a poor quality COLOR BURST level: Testing the color burst level will determine if the burst signal is sufficient to trigger the displays color producing circuit. Burst will diminish in amplitude over longer cable runs and
6
can get fall below the threshold for the video display to show a color image. For NTSC format, the Chroma standard level is 40 IRE For PAL format, the Chroma standard level is 280mV If the Chroma level is too low, the color will not be as deep, and some details of the image will get washed out. If the Chroma level is too high, there will be spots on the image. If the coaxial cable is too long, it will reduce the chroma level
2.3.10 PTZ controller
Display the input video images. Pan/tilt the P/T unit and zoom in/ out the image. Setup the controlling parameters like protocol, communication port, baud rate, PTZ ID, pan/tilt speed; set and call preset position.
2.3.11 Enhanced Color bar generator
The tester sends out color bars via its BNC output to the monitor. This is used to test for a problem in the cable going from the camera back to the monitoring area
2.3.12 DC12V 1A power output
Power the camera with DC12V (1A) power output from the tester. It is helpful for demo and testing
when the power supply is not available
2.3.13 Audio testing
Test the audio from mic level input devices. Connect the tester and mic level device with the audio cable. Supports record and save the audio.
2.3.14 Cable tester
Test LAN cable or telephone cable. Connect LAN cable or telephone cable with the CCTV tester and cable tester. And then the connecting status, cable type and the sequence of wires will be displayed, as well as display the serial number of the cable tester kit.
7
2.3.15 PTZ data analysis
Search the Control protocol code from Multifunction keyboard or DVR by RS485 interface, test the PTZ control command data whether received anomaly and RS485 data transmission.
Screen displays 16 hexadecimal codes such as PELCO-P:A0 00Add xx xxxxxx AF xx PELCO-D:FF 01Addxx xxxxxxxx
2.3.16 Digital Image zoom on the monitor
Set image zoom up to 4X to get a closer look at all the image detail. Supports analog and many IP
cameras
2.3.17 Video screenshot
Capture the video image, and save it as JPEG file in the SD card.
2.3.18 Record
Capture the video frames as JPEG file
2.3.19 Playback
The recorded files can play directly via Media player or under the function of Playback.
2.3.20 Cable tracer * Optional
Cable identification by use of an audio signal. This function enables the blue cable tracer to find the connected cable from a bundle of cables with an audio tone.
2.3.21 DHCP dynamic address assignment
Built in DHCP server: Dynamically assign IP address for the IP camera or network device.
2.3.22Access the dynamic IP address
The IP tester can directly access a dynamic IP address assigned from its DHCP server and use it as the tester's IP address. No need to set a IP address manually.
2.3.23 Multiple network IP Cameras Test
Supports Multi- segmented Static IP address setting which can simultaneously test different segments of
8
IP network cameras.
2.3.24 Network bandwidth testing
The network bandwidth test needs two IP testers to test bandwidth: one as a transmitter, the other as a receiver.
2.3.25 IP address scan
The IP address scan can quickly search for connected IP cameras or another network device IP address.
2.3.26 PING Test
PING is the most conventional network debugging tool; it is used for testing if the connected IP camera or other network equipment is working normally and the IP address is correct
2.3.27 Port Finder
The tester will send signals to make the connected PoE port flicker at a set frequency. This will enable the installer to easily and quickly find the connected port for an Ethernet cable.
2.3.28 PoE Test
Test the PoE voltage from a PoE switch. The unit will clearly display the voltage for each wire in an Ethernet cable.
2.3.29 Digital Multi-meter* Optional
The tester built in highly stable and reliable 33/4 digit (6600) digital multi-meter. It is used for the DC and AC voltage measurement, AC and DC current measurement, Resistance measurement, Continuity test, Diode measurements, Capacitance measurement, Auto/Manual measuring range switching, relative value measurement and locking. It is easy operation and professionally accurate.
2.3.30 Visual fault locator* Optional
Visual Fault Locator with 650nm wavelength can emit red laser sources to test multi-mode and single mode fiber’s bending and breakage, and Continuous light-emitting and 1HZ, 2Hz modulating light
output. It is indispensable tool in fiber project constructing, fiber net-work maintaining, optical
component manufacture and research.
9
2.3.31 Optical Power Meter* Optional
The IP camera tester adopts the most advanced handheld instrument specific integrated chip , achieve ultra-low power operation, with the 3.5 TFT-LCD High-definition screen display ,five wavelength calibration points 1625nm,1550nm ,1490nm , 1310nm , 1300nm , 850nm.Linear or nonlinear optical power display, it can measure the optical power value, and also be used for Relative measurement of optical fiber link loss. It is necessary tool for fibre-optic communication, cable television system and security system maintenance.
2.3.32 LED Flashlight
Press the LED On/Off button to use the LED flashlight.
2.3.33 Screen image rotates 180 degrees
You can manually rotate the display 180 degrees using the settings.
2.3.34 TDR cable open circuit and short circuit measurement* Optional
TDR cable testing, accurately measure BNC cable, network cable, controls cable’s open circuit and short-circuits location. It improves working efficiency.
2.3.35 FTP Server
Start the tester’s Wi-Fi or connect the tester’s LAN port to the network. Once the tester is online, start its FTP Server and directly access files from the tester’s SD card. This also allows for the user to upgrade the tester firmware
10
2.4 Packing list
1). Tester
2). Adaptor DC12V 1A
3). Network cable tester
4). Polymer lithium ion battery 3.7V DC 3000mAh
5). BNC cable
6). RS485 cable
7). SC,ST connectorOnly for optical power meter
8). Multi-meter test leads one pair of red and black (only for the Multi-meter models)
9). Camera powering cable
10). Audio cable
11). TDR alligator clamp (only for TDR models)
12). Safety cord
13). Tool bag
14). User’s Manual
15) 4GB SD card
11
2.5 Function interface
12
1
Press more than 2 seconds, turn on or off the device ,short press to turn on or off the menu display
2 Set key
3 Menu key
4 Near focus: Focus the image nearby
5 Far focus: Focus the image faraway
6 TELE: zoom in the image
7 WIDE: zoom out the image
8 Open/set ,Confirm the setting of parameters, open or enlarge the aperture
9
Return/Close : Return or cancel while setting parameters of the menu, close or decrease the aperture
10 Upward, set function or add parameter. Tilt the PTZ upward
11
Rightward, select the parameter whose value will be changed. Add the value of the parameter. Pan the PTZ right
12 Leftward, select the parameter whose value will be changed
13
Downward, set function or reduce the value of the parameter. Tilt the PTZ downward
14 Open/set ,Confirm the setting of parameters, open or enlarge the aperture
15 Snapshot
16 Video record
17 LED lamp
18 Confirm key
19
Return/Close : Return or cancel while setting parameters of the menu, close or decrease the aperture
20 The power indicator: it lights green while the tester is powered on by the adapter
21 The data accepted indicator: it lights red while the data is being received
13
22
The RS485 data transmission indicator: it lights red while the data is being transmitted
23
The charge indicator: it lights red while the battery is being charged. As the charging is complete, the indicator turns off automatically
Top interface
Left interface Right interface
14
24
Video signal inputBNC interface
25
Video signal outputBNC interface/cable tracer interface ( Optional)
26
TDR cable test interface / TVI input (BNC interface)
27
DC12V1A power output , for provisional DC power supply
28
Not support RS232 communication
29
LED flashlight (lamp)
30
RS485 Interface: RS485communication for the PTZ
31
LAN test interface
32
PSE power sourcing equipment. Tests PoE voltage
33
Audio input
15
34
Reset key
35
UTP cable port: UTP cable tester port/ Cable tracer port
36
DC12V1.5A charging interface
37
Micro SD card removable (comes with 4GB, supports up to 32GB)
3. Operation
3.1 Installing the Battery
The tester has built-in lithium ion polymer rechargeable battery. The battery cable inside battery cabin should be disconnected for safety during transportation! Usually it doesn’t need to disconnect the cable at the normal use Pressing the key continuously can power on or off the tester.
Notice: Please use the original adaptor and connected cable of the device!
When the battery icon is full or the charge indicator turns off automatically, indicate the battery
charging is completed
When the Charge Indicator turns off, the battery is approximately 90%
Charged. The charging time can be extended for about 1 hour and the charging time within 12 hours will not damage the battery.
Notice :Press the key several seconds to restore the default settings when the
instrument works abnormally.
Multi-meter: the red and black multi-meter pen must insert the corresponding port.
Warnings: Instrument communication port is not permitted access circuit voltage over 6V,
16
otherwise damage the tester.
Warnings: Not allow insert multi-meter pen in the current terminal to measure voltage
3.2 Instrument connection
3.2.1 IP camera connection
Power an IP camera with an independent power supply, then connect the IP camera to the IP tester's LAN port, if the link indicator of the tester's LAN port is green and the data indicator flickers, it means the IP camera and the IP tester are communicating. If the two indicators don't flicker, check if the IP camera is powered on or the network cable is not functioning properly.
Warning: PoE switch or PSE power sourcing equipment only can be connected to tester PSE
IN” port, otherwise will damage the tester.
17
3.2.2 Analog camera connection
(1) The camera or dome video output is connected to CCTV IP Tester VIDEO IN,the image display on the tester . (2) IP Tester “VIDEO OUT” interface connect to the Video input of monitor and optical video transmitter and receiver, the image display on the tester and monitor (3) Connect the camera or the speed dome RS485 controller cable to the tester RS485 interface (Note positive and negative connection of the cable)
3.2.3 HD Coaxial camera connection
*TVI camera are classified as HD coaxial cameras. Hereby the following instruction of how to connect SDI camera to the tester is also applied to TVI camera.
18
(1) Connect the SDI camera's video output to the IP tester’s “SDI IN” interface, the image will display on the tester. The tester only come with SDI input interface. There is no SDI output interface. (2) Connect the SDI camera or the speed dome RS485 controller cable to the tester RS485 interface (Note positive and negative connection of the cable).
3.3 OSD menu
Press the key 2 seconds to turn on Press the key 2 seconds to turn off short press the key to enter sleep mode, press it again to test if tester work abnormally
and cannot be turned off , Press the key several seconds to turn off, the tester reset
19
Select Icons to enter, if quit, Please click
Click SD card, install or remove SD card
Press function Icons seconds, tip: whether move this icon to APPS file, if some function not be often
20
used, can move these function icons to APPS.
To move an app icon to the “APPS” folder, press and hold until the “move to apps directory” appears
on the screen then press OK to move it or Cancel
Click icon “APPS” tool, to show all collected function icons, Click , back to the testers
main menu
In APPS file, Select icon and press it for seconds, tip: whether move the file to the desktop?
21
3.3.1 Video monitor test (PTZ control)
Analog camera test and PTZ control, click icon to enter
Display the input video image, click the top menu bar icon to enter video level meter, (PEAK level, SYNC level, COLOR BURST measurement) Select relative function on the right side Toolbar to operate , functions including “Photos”, Snapshot ,
22
Record , Playback , PTZ , Set , Click to quit, or press back to menu. Click the screen twice quickly, can be full zoom in on the touch screen.
3.3.1.1 PTZ controller parameter setting
Select and click icon “PTZ” ,to enter PTZ setting:
A. Protocol Use the up and down arrow keys to move the yellow cursor to the “protocol , set corresponding Protocol and support more than thirty PTZ protocols. Such as Pelco-D,Samsung,Yaan,LiLin,CSR600,Panasonic,Sony-EVI etc.
B. Port
Click and move, to “port” Select the communication port for the PTZ camera controlling (RS485) C. Baud Move the yellow cursor to “Baud”, Select the baud rate according to baud rate of the PTZ camera.(150/300/600/1200/2400/4800/9600/19200/57600/115200)
D. Address
Set the ID according the ID of PTZ camera (0~254), the setting address data must be consistent the speed dome address. E. Pan speed: Set the pan speed of PTZ camera (0~63)
23
F. Tilt speed: Set the tilt speed of PTZ camera (0~63) G. Set preset position (Set PS) Click and select “Set PS”, set and save preset position number (1~128), H. Call the preset position (Go ps)
Click and select “Set PS”, set and save preset position number (1~128), click “sure” to save, Call some special preset number, can call the dome camera menu
Check and set the protocols, address, interface and baud, all must be consistent with the dome camera, dome camera, then the IPC tester can test .After setting the parameter, the tester can control the PTZ
and lens To control PTZ by screen touch: Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction. By two fingers move outward and inward on the touch screen to zoom in and out the PTZ.
Press the key control the PTZ direction of rotation Press or to switch on or turn off the aperture.
Press or adjust the focus manually Press or manually adjust the zoom
24
3.3.1.2 Video and storage setting
Click icon "set" ,to enter and set analog video image brightness , contrast, color saturation, as well as the file storage way after snapshot and recording, support auto-storage and manual storage. When select manual storage, user can name and store the files.
3.3.1.3 4 x zoom image display and Video out
When image input, press to enter “zoom” ,press it again to quit. Using the touch screen to control PTZ camera movement: Tap left, right, upward or downward on the video image to move the PTZ camera in a desired direction. Stretch two fingers outward or inward on the touch screen to zoom the image in or out.
if not by touch screen to operate ,press the key to zoom out , press the key to zoom in, press upward and downward key to move the image
25
For analog video input, as the resolution is 720*480, it is normal that the zoom in image is not
clear. But for network digital video input, as it supports resolution up to 1280*960, the zoom in image is still very clear. This is very helpful for IP camera installation.
3.3.1.4 Snapshot
Click the icon "Snapshot ", when the video in, to take a picture and save the current video frame in the SD card as JPEG file. If the unit is set to the manual mode an "Input Name" pop up box will appear and you can enter a title for the snapshot. If the unit is set up to automatically set file names, this box will not pop up.
3.3.1.5 Video record
When you click the "Record" icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video. Click on the "Record" icon again to stop recording and save the video file to the SD card. if select manual storage, before recording begins ,appears dialog box "Input Name" ,user-defined the files name(by Chinese character, English letter ,or digit) to store in SD card , tester will hereby store the files in SD card after recording ., if select Auto-storage ,tester will auto store the files in SD card after recording .
26
3.3.1.6 Photo
Click the icon "photo" to enter, click the selected thumbnail photo to display it on the screen. Double-tap the image you want to view to make it full screen. Double-click again the photo to return.
To rename or delete an image, click and hold on the file until this screen below appears
27
Click to close and return to PTZ controller.
3.3.1.7 Record playback
Click the "Playback" icon to view your recorded videos. Tap on the video file image you want to watch.
To rename or delete a video, click and hold on the file until this screen appears:
28
Video files also can play in the main menu “Video Player".
3.3.1.8 Video level meter* Optional
Click the icon to enter, the IP camera tester has adopted hardware high-speed sampling and processing technology, can perform both NTSC and PAL video amplitude signal measurements for PEAK to PEAK, SYNC level and COLOR BURST Chroma level. When an analog signal is fed into the meter, the tester displays the measurements on the bottom left corner of the screen.
While in PAL format, the unit will be mV, While in NTSC format, it will be IRE.
29
NTSC
Video signal level
140±15IRE
Chroma level( COLOR BURST)
40±5IRE
SYNC signal level
40±5IRE
PAL
Video signal level
1000±200mV
Chroma level( COLOR BURST)
300±35mV
SYNC signal level
300±35mV
Video signal PEAK to PEAK level: For NTSC format, the video signal level is 140±15IRE For PAL format, the video signal level is 1000±200mV If the level is too low, it will cause the image to lose quality and limit the distance it will travel over cable. If the level is too high, it will distort the image. SYNC level: Tests the amplitude of the video sync pulse to verify if the video level is correct. For NTSC format, the SYNC level is 40 ± 5IRE For PAL format, the SYNC level is 300 ± 35mV If the level is too low, it will cause the image to not frame out properly. If the level is too high, it will lead to a poor quality image. COLOR BURST level: Testing the color burst level will determine if the burst signal is sufficient to
30
trigger the displays color producing circuit. Burst will diminish in amplitude over longer cable runs and can get fall below the threshold for the video display to show a color image.
For NTSC format, the Chroma standard level is 40 IRE
For PAL format, the Chroma standard level is 280mV If the Chroma level is too low, the color will not be as deep, and some details of the image will become lighter. If the Chroma level is too high, there will be distortions on the image. If the coaxial cable is too long, it will reduce the Chroma level. Image loop testTest video optical transmitter and receiver and video cable, connect one end to the tester VIDEO OUT” port ,and the other end connected to VIDEO IN” port, the signal send via VIDEO OUT port ,and received via VIDEO IN port , If the testing is ok, the tester displays several gradually dwindling photos on the desktop.
3.3.2 Color-bar generator (TV OUT)
Click to enter, the tester send the color bars from the “Video out” port ,Click the icon “PAL”, select “PAL/NTSC” output formats
Click the selected color-bars, testing image or single bar (red, green, blue, white or black). Double click
31
to full display on the screen and output, click to return main menu. Application A. When maintaining the dome camera, the tester sends out the color bar by its BNC output to the monitor at the monitoring center. If the monitor receive the color bar, it means the video transmit channel works normally. Meanwhile on the basis of the received color bar, the monitoring center can judge if transmission has loss or interference. B. The tester sends out the pure color bar (such as white and black color), to test the monitor whether
has bright or black dots C. The tester sends out video signal image to test if the image received by the monitor has excursion.
3.3.3 ONVIF
The Open Network Video Interface Forum (ONVIF) app is used to connect to ONVIF compliant IP
cameras only. If the IP camera's video stream is MPEG4, use the ONVIF (SD) mode. If your IP camera's video stream is H.264, use ONVIF HD (High Definition), HD mode cannot support MPEG4. While in SD mode, if the network camera resolution is 720P or higher 720P, the image display may be delayed. While in HD mode, if the network camera stream is H.264, the tester can fluently display the image up to 1080P.
Click icon to enter then tap either the "ONVIF" icon is for SD mode (MPEG4) and the "ONVIF
HD" icon is for HD mode (H.264).
32
Click icon to enter, the tester Auto-Scan different network segments ONVIF cameras, and list the camera name and address on the screen left. Some cameras not need user name and password to login, Please select “Non- verification” to login the camera.
If you select ONVIF SD or HD mode, the meter automatically scans different network segments for ONVIF cameras. It lists the camera name and IP address on the Device List. If no cameras appear under the device list, try clicking on the Refresh button
Click “refresh”, the IPC tester scanned ONVIF network camera on the internet. Click the camera in the list of devices, camera login window pops up. Input the camera’s username and
33
pass word. Some network cameras, does not require a user name and password authentication, check "non-verification" and then login the camera.
Click “device list” of the tester’s screen left, will shows the camera information and setting. Such as
Device information”, “Time setting”, “Maintenance” “Network setting”, “User management”, “Live video”, “Image setting” etc. Some functions must camera's setting open to operate.
Live Video: Click "Live Video" to view the live video feed from the IP camera. To make the image full screen, double tap on the video. Stretch two fingers outward or inward on the touch screen to zoom the image in or out. If you want to zoom in or out ,please press the key tele and wide
34
ONVIF PTZ control: Tap the image in the direction you want the PTZ camera to move. Tap the left side of the image to move left, right to go right, up to go up and down to go down. Compatible IP PTZ cameras will rotate accordingly. PTZ rotation direction is displayed on top left corner of the image.
Video Streaming: Click “Video Set to enter, set the IP camera decoding resolution, click “OK “to save.
35
Image setting: Click "Imaging Set" to adjust image brightness, saturation, contrast, sharpness and backlight compensation mode.
Profiles :Click"profiles", can view video streaming current configuration files, as well as switch between Major stream and minor stream .
36
Preview pictures:Quickly preview and zoom in or out pictures, automatically and manual refresh
Network setting: Click “Network Set” to change the IP address settings. Note: Some cameras are not fully ONVIF compliant and cannot support changing their IP address, so
there is no change after saving.
37
Zoom in image: press the key to enter the zoom mode. Press it again to exit zoom mode. When the image is enlarged tap left, right, up or down on the image to move the whole image on the screen
When the image is enlarged, if not operate on touch screen, it can operate by the keyboard ,press the key to zoon in , press the key to zoom out ,press upward and downward key to move image .
If it is network video input to the tester, as the tester supports resolution up to 1080p, the input
image will be very clear after it is enlarged. This is greatly helpful to help the installers to ensure the IP
38
cameras video coverage and decide the IP cameras install site. Image can only be enlarged on SD mode (The icon ONVIF is SD mode.) On the interface of Live Video”, click “Video Menu”, appears toolbar: Snapshot, Record, Photo, Playback, PTZ, Set, etc.
Snapshot: Click snapshot” to screen shots and storage if select manual recording ,appears dialog box “Please input the files name” , user-defined the files name(by Chinese character, English ,or digit ) to save in SD card, if select “Auto-recording”, the tester auto-recording the files after screenshots . Record: When you click the "Record" icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video. Click on the "Stop" icon to stop recording and save the video file to the SD card.
39
Set: Click icon “Set”, Photo and record function can select, if Auto-name, Photos and recording files Auto-storage, if manual, user define files name.
Playback: Click the "Playback" icon to view saved videos. Double click the video you want to play. Click to return to the last menu
To rename or delete a photo, click and hold on the file until this screen appears:
40
Video files can play in the Video player of the main menu
3.3.4 IP camera test
Click icons to enter IP camera test
The “IPC Test” app is used for IP cameras that are fully integrated by name with the IP tester . If the IP
camera's video stream is MPEG4, use the IPC Test (SD) mode. If your IP camera's video stream is H.264, use IPC HD (High Definition)
Display high-definition images, support snapshot, video record and playback. Currently, the IPC tester only support some brands’ specified IP cameras, the brands include Dahua , Hikvision, Kodak , Samsung, etc. OEM service is available. Clients can send us the IP camera or mobile APPS (Android version. APK files) for our engineers to try to add the protocol to the IPC tester.
Note:Currently, the IPC Test App only supports some brands' specific IP cameras; these include
specific models made by ACTI, AXIS, Dahua, Hikvision, Samsung, and many more. If the camera is not fully integrated, please use the ONVIF or RTSP apps.
41
IPC test interface
Local IP:This is the tester's IP address. Click "Edit" to enter "IP setting" and change the tester 's IP
address settings IP camera type :Click IP camera type, list Honeywell , Honeywell , Kodak,Tiandy, Aipu-waton,VVS, ACTi,WoshiDA IP camera etc. If the brand has offered official original protocols, Pls select camera
type, input IP camera address ,user name and password ,click” official” to enter the camera image
display interface(Currently, only support DAHUA official protocols )
IP Camera's address: Enter IP cameras IP address , click deploy o add IP address of the Different
network segments, support multi- network segments’ IP camera test .
Click Search” to auto-scan the IP cameras IP address and display. It is better to directly connect IP
camera to the tester so that the tester will search out only one IP address. If the tester is connected to PoE switch, it will search out several IP address.
IPC User Name: Enter IP camera’s user name
IPC Password: Enter IP camera’s login password, if default enter password, not show relevant letters,
click “display” to show the password IPC Port No.: Select IP camera type, it default relative camera port number, and not need change. After setting, click Enter to enter image interface.
42
If IP address setting has error or IP camera is not connected.. The tester prompts Network Error Click to quit from image display and return to IP camera test interface.
Under the IPC Test , on the IP camera image display, there is Video Menu icon, click “Video
Menu”, appears toolbar: Snapshot, Record, Photo, Playback, PTZ, Set, etc. Please refer to ONVIF to use these functions
43
3.3.5 TVI camera test
HD TVI camera, TVI dome camera test and PTZ control, Click icon to enter
When tester receives HD TVI camera image, it will display the image’s resolution on the top bar. Double-taps on the screen to make the image displayed full screen. Tester supports resolution as follows 1280x720P 25FPS / 1280x720P30FPS / 1280x720P 50FPS / 1280x720P 60FPS 1920x1080P 25FPS / 1920x1080P 30FPS / 1920x1080P 50FPS / 1920x1080P 60FPS
More operation instructions (such as PTZ control, coaxial camera menu setting, snapshot, recording and playback etc), please refer to“3.3.6 CVI camera test” 1PTZ control
44
1.1 Click the icon “PTZ” on the right toolbar to do the corresponding setting. Port”: select coaxial control
Enter PTZ address to perform parameters setting
Operation instructions please refer to “3.3.1 PTZ (1) PTZ control parameters setting”
The PTZ address in the tester must be consistent with the dome camera or decoder, then the IPC
tester can test .After setting the parameter, the tester can control the PTZ and lens.
45
To control PTZ by screen touch: Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction, PTZ cameras will rotate accordingly. By two fingers move outward and inward on the touch screen to zoom in and out the PTZ. PTZ control by press key button
Press arrow keys to control the PTZ direction of rotation Press the key to switch on or turn off the aperture. Press the key , adjust the focus manually Press the key ,manually adjust the zoom
1.2 RS485 control
46
Operation instructions ,please refer to “3.3.1 PTZ (1) PTZ control parameters setting” 2Coaxial camera menu setting Click Coaxitron and select “camera menu”, can open the dome menu
Input calling dome camera menu address code, click ok”, then press key button“ ”or click screen icon
Press arrow keys to set
47
(3)Snapshot, record, photo viewer and video playback, please refer to 3.3.1 Video monitor test
(4)Save setting Click icon “Set” on the right toolbar to enter storage setting. Support auto-storage and manual storage. When select manual storage, user can name and store the files.
48
3.3.6 IP address scan
Connect the cable to the LAN port, click icon to enter, set initial IP and destination IP address,to the testers IP address network segment can be the same or different to the scanned network devices network segment, then click the key “Start” to scan, quickly to search the IP address, also can input the IP address in the Port Number Scan to scan to port number ,check the tested devices supporting port number and how many ports can support the devices network communication..
3.3.7 PING Test
PING is the most conventional network debugging tool; it is used for testing if the connected IP camera or other network Equipment’s Ethernet port is working normally and the IP address is correct.
Connect a network cable to the LAN port and click the icon to open the PING tool. You can set your LOCAL (native) IP address, Remote IP address (e.g. IP camera), Packet count, Packet Size, Packet
time and Timeout. Press “Start” to start pinging. If the IP camera or network device is not configured properly or not plugged in, it will say “Destination host unreachable,” or have 100% packet loss. If the
tester connects to the device, the send and receive packets will have a 0% packet loss.
49
Application: PING testing is the most conventional network debugging tools. It is used for testing if the connected IP camera or other network equipment’s Ethernet port is working normally and the IP address is correct. It’s normal that the first data packet will be lost when test start.
3.3.8 Cable test
Click icon to enter
50
Test LAN cable or telephone cable. Connect LAN cable or telephone cable with the CCTV TESTERPRO and cable tester. And then the connection status, cable type and the sequence of wires as well as the serial number of the cable tester kit will be displayed. The number of the cable tester is 255 If need several different number other types cable testers, should pay the additional cost.
3.3.9 Port finder
Connect a network cable to the meter’s “LAN” port; click the icon to open the Port Flashing app. Click “Start”. The IP tester sends a unique signal to make the connected LAN port of the switch flash
If the tester and PoE switch are connected well, the LAN port of POE switch flash at special frequency, If not, no any changes on the LAN port
51
Application:
The tester will send special signals to make the connected LAN port flicker at special frequency, which will enable the installers to easily and quickly find the connected Ethernet cable. This function can prevent mistakenly insertion or disconnection non-corresponding cable to artificially interrupt network connection.
3.3.10 Data monitor
Please click icon to enter
Click “Setting” to choose the baud rate of RS485; it must be the same as the DVR or the Control
keyboard .The DVR or Control keyboard send the code to the tester, if it can be read, the protocol will
52
AC/DC
Voltage and current measurement state display
Auto- range
The Multimeter auto adjust the range by input signal or tested components
Data hold
Hold data
Relative
measurement
Display the relative measurement value Press the key to change display state
10A socket
In 10A current measurement state ,indicate use 10A socket
Over range
The current measurement value over the range, if in the Auto range state, to switch Auto.
shown on the upper right, like Pelco D, if not, like P:---
When the tester receives the code, Press the key to clear screen.
Though the RS485 port, display the PTZ control code of the multifunctional keyboard or the DVR. Controller can check the status of the RS485 transmission through the code on the display. (The RS485 communication rate must be the same.) Application: Check the RS485 communication states of the video optical transmitter whether normal. Engineer can analyze the protocol and check the data through the displayed code.
3.3.11 Digital Multi-meter* Optional
1.Click icon to enter
2) SYMBOLS: U:DC Voltage Measuring A:DC Current Measuring Ω:Resistance Measuring :Diode Testing
U~:AC Voltage Measuring A~:AC Current Measuring
:Continuity Testing :Capacitance Measuring
53
OPERATING INSTRUCTION
DC Voltage Measuring
a. Connect the black test lead to the “COM ” jack and the red test lead to the “V/Ω” jack.
b .Select U, enter the DC voltage measurement.
c. the tester default Auto range status ,by click “DC auto range” ,
press the key can select manual range and restore auto range . Manual range: 0.000V 6.600V range
00.00V 66.00V range
000.0V 660.0V range
000.0mV 660.0mV rang
AC Voltage Measuring
a. Connect the black test lead to the “COM” jack and the red test lead to the “V/Ω” jack. b. select U ~ , enter the AC voltage measurement. C. the tester default Auto range status, by click “AC auto range” d. Manual range can be select , press the key “NEAR” to restore Auto range eManual range: 0.000V  6.600V range
00.00V 66.00V range
000.0V 660.0V range
000.0mV 660.0mV range
DC Current Measuring (only manual range )
WARNING!
Shut down the power of the tested circuit, and then connect the meter with the circuit for measurement. a. Connect the black test lead to the “COM” jack and the red test lead to the “mA” jack for a maximum of 660mA current. For a maximum of 10A, move the red lead to the 10A jack. bselect A, enter the DC current measurement, the screen display “DC current ”,can select manual
54
range cManual range: 0.000mA 6.6mA range
00.00mA 66.00mA range
000.0mA 660.0mA range
00.00A 10.00A rangeuse 10A socket
d. Select the range to enter current measurement
Note:
When only the figure “OL” is displayed, it indicates over range situation and the higher range has to
be selected.
When the value scale to be measured is unknown beforehand, set the range selector at the highest
position.
The maximum current of mA socket is 660mA; over-current will destroy the fuse, and will damage
the meter.
The maximum current of 10A socket is 10A, over-current will destroy the meter, and will damage
the operator.
In“ AC ” mode, only can input “AC ”, if not, will damage the meter.
Resistance Measuring
WARNING!
When measuring in-circuit resistance, be sure the circuit under test has all power removed and that all capacitors have discharged fully.
a. Connect the black test lead to the “COM ” jack and the red test lead to the “V/Ωjack. b. to select Ω, enter the Ω measurement the tester default Auto range status, Press the key manually
55
select range ,Press “NEAR” to restore “Auto range” Manual range: (Connect the red lead to black leads, will display the measure range)
000.0Ω 660Ω range
0.000 KΩ 6.600KΩ range
00.00 KΩ 66.00KΩ range
000.0 KΩ 660.0KΩ range
0.000 MΩ 6.600MΩ range
00.00 MΩ 66.00MΩ rang
Continuity Testing
a. Connect the black test lead to the “COM” jack and the red test lead to the “V/Ωjack.
b. to select , enter the continuity test, Connect test leads across two point of the circuit under testing. c. If continuity exists (i.e., resistance less than about 50Ω), built-in buzzer will sound.
Diode Testing
a. Connect the black test lead to the “COM” jack and the red test lead to the “V/Ω” jack. (the red lead
anode “+” )
b. to select , enter the diode testing. c. Connect test red lead across to the anode, the black lead to the cathode of the diode under testing. d. Connect test red lead across to the cathode, the black lead to the anode of the diode under testing. e .Tested diode, forward voltage low 30mv,there is sound indication ,then can finish the testing quickly without view the screen.
56
Capacitance Measuring
a. Connect the black test lead to the“ COM ” jack and the red test lead to the “V/Ω jack. b. Select “ ” to enter, enter the capacitance measurement.
c. The tester default auto range status, and manual range by press upward and downward key, Auto rang by press the key “NEAR” Manual range:0.000nF 6.600nF range
00.00nF 66.00nF range
000.0nF 660.0nF range
0.000uF 6.600μF range
00.00uF 66.00μF range
000.0uF 660.0μF range
0.000mF 6.600mF range
00.00mF 66.00mF range d. Before connect test leads across two sides of the capacitor under measurement, be sure that the
capacitor has been discharged fully.
Note:
a. The capacitance of a capacitor should be tested separately, should not test in
the installation of circuit.
b. To avoid electric shock, be sure the capacitors have been discharged fully before measuring the ca
pacitance of a capacitor.
c. While testing the capacitance of a capacitor to
660uF, the Max time will be 6.6 seconds, if the capacitor is leaked or damaged, the data can’t be read. The tester will be normal after disconnecting the capacitor.
Manual range and Auto range When testing, click “Range select " to change the value, click “Auto range “to enter Auto measurement
57
Data hold
Click “Hold data” to enter, the data be hold, the value is green. Press it again to quit.
Relative value measurement
Click “Relative “to enter ,the tester Auto-save the data, the displayed new measurement and relative value is red color. Press it again to quit
The hold function and the relative value be combined use, the display value is yellow
The meter protection Voltage protection
You can’t input the voltage which more than 660V AC, it’s possible to show higher voltage, but it’s may destroy the inner circuit.
Resistance,Continuity,Diode,PTC component Protection
Wrong input voltage,will Auto enter protection state , It only suitable for short and limit time work.
If input voltage over 600V, will damage the meter.
mA current fuse range :250V 1A
if the current over the rated range ,fuse will melt to protect the meter .Please use the same model
58
when change the fuse, Please opens the battery cover to change.
Note: 10A socket without fuse protection, if over the current range
Wrong using the 10A socket to measure the voltage, will damage the meter.
3.3.12 Media Player
Click the icon to enter
The Media player can browse video and image files. It supports the video formats of MP4, H.264, MPEG4, and MKV. The IP Tester’s recorded files can play directly via the Media player. The Media player will automatically display the video files from the SD card. Click on the desired file to play. Click RETURN to exit. To rename or delete an existing file, press the file name for a few seconds until the screen below appears. You can then rename or delete the file by pressing the desired option.
59
3.3.13 Audio player
Click the icon to enter , the audio player only supports MP3 format Audio files.
3.3.14 LED Flashlight
It is convenient for the installation or maintenance in the evening or in the dark. Click icon to enter
While in the flashlight app, click the red button to turn on the LED lamp. Press it again to turn it off. If you don’t press the red button to shut off the lamp and press the button to exit the app, the lamp
60
will stay on. Click the Time Setting button to set a timer that will shut off the lamp.
3.3.15 PoE/PSE Voltage test
Click icon icon to enter the PoE voltage in line measurement app.
Connect a network cable from a PoE switch to the IP tester’s PSE IN port. Connect an IP camera or other PoE using node to IP tester’s LAN port, the PoE voltage and the cable’s pin connection status show on the screen.
Note:This test if for measuring the voltage being drawn by the PoE node and the IP tester must be between the PoE switch and the PoE node for this test to work. Note: The PoE switch must be connected to the PSE IN port. The powered device such as IP camera or other PoE node must be connected to the LAN port. Note: Do not connect PoE power supply equipment (such as a PoE switch) to the tester’s UTP/SCAN port; otherwise it will damage the tester.
61
3.3.16 Calculator
Click icon to enter
3.3.17 Browser
Click icon to enter Type in the camera’s IP address and press “Go” to access the IP camera’s interface.
NOTE: You will not be able to view live video in the web browser. For viewing video, use the
IP tester live camera view apps.
62
The IP camera and IP tester must be on the same network segment for the browser to interface with the camera. If they are not in the same segment, click the button or press “RETRUN” to exit. Open the “Settings” app from the main menu to change the IP tester’s network settings to match those of the IP camera.
3.3.18 IP camera viewer
In addition to the ONVIF app or the IPC Test app, you can use one of the mobile apps in the IPC Viewer folder to view IP camera video. If you cannot find your desired mobile apps, you can send us the mobile apps (Android version. APK files) for our engineers to install in the tester, if successfully installed, the tester will allow you to see the IP camera image by IP camera viewer.
Click icon “IP camera viewer” to enter, and set the mobile apps parameter to see the corresponding IP camera’s image.
Mobile apps displays IP camera’s image by software decompression, hereby the image may be not clear or fluent.
Note::The mobile apps are third party applications. Our company does not support these apps nor make any usage claims. We do not assume any legal liability
63
Click desktop icon several seconds, to uninstall this application
Click icon “update “ in the IPC viewer interface, to update mobile apps
64
3.3.19 DC12Vpower output
Click icon to enter DC 12V power output interface. To use the DC 12V power output function, click on the icon and change the switch “ON” or “OFF”.
If to click without prior to change the switch “ON” to “OFF”, the 12VDC power output will till stay on, and the icon12V ON” appear on the top bar. Change the switch “ON” to “OFF” to shut off the 12VDC power output.
65
1 .Don’t input any power into the “DC12/1A OUTPUT” port of the IP camera tester to avoid
destroy.
2. Don’t output this DC12V/1A power to the DC12V/IN port of the IP camera tester to avoid destroy
3. The IPC tester power output is close to 1A, if the IP camera’s power is over 2V, the tester will auto enter protection mode. Disconnect all the connections of the tester and then connect the tester with power adaptor to resume the tester.
4. Make sure the tester is full charged or more than 80%, otherwise the tester will shows “low
power”, “not able to supply power”
3.3.20 Application tools
Click the icon to open the Application Tools folder. This folder contains useful apps such as Audio Recording, DHCP Server, Network test, Notepad, Link monitor and RTSP Player.
Audio Record: Connect an audio device t the IP tester’s audio input port. Click the icon to enter the Audio Recorder app. Click the red button to stop, and the unit will prompt you to save the recording.
Net work test (Ethernet bandwidth test) To use the Network tester, you will need two IP testers. One is used as a Server and the other as a Client. Both devices must be on the same network segment in order to communicate. Click the icon to
66
open the Network Tester app. Note: Network test results only used as a reference, For more accurate test , please use a professional Ethernet tester .
When test , need a tester or a computer installed Network Test Software as the Server, the other tester
sends packet test. The two testers must be in the same network segment.
1. Start the server: Click Start Server button to use the tester as a Server. It will display its IP address at the top of the screen.
67
2. Start send packet test::Using the other IP tester and type in the Server's IP address at the top right corner of the screen. This app is used to send packets for network speed testing. Click the “Start” button to send the packets and start testing.
Network bandwidth testing can also be tested with a computer using compatible network bandwidth testing software. Install network bandwidth testing software on a computer, as a test Client or Server, with tester mutual –testing. If computer as the server, the computer IP address is :192.168.0.89
68
Tester as Client, tester’s IP address is:192.168.0.230. The Server and the Client are at the same network segment, but with different IP address. Input Server’s IP address 192.168.0.89 in the tester and click “Start” to test network bandwidth.
Or tester as a Server, computer as test Clientselect Client, input testers IP address to test
69
When tester as Server, shows results:
DHCP server:
Click on the DHCP icon to open the DHCP server app. Select the “Start” check box at the top and make
any desired changes to the network settings. Click “Save” to start assigning dynamic IP addresses for IP cameras and other networked devices.
Click the “Refresh” button to check your Client list.
Refresh” to check received IP address.
70
Notepad:
Click on the Notepad icon to open the Notepad app. Click the “Save” key to save the contents
pls click to view the notepad , all saving contents display. Click each record bar to show the details. Press the record bar for several seconds, prompt whether delete it
71
Link monitor :
Click the icon to open the Link Monitor app. This app is used to see if an IP address is occupied by other network devices. This will avoid new address conflicts.
Click “Add” and enter the desired IP address. To test different network segments, click the “Settings”
icon on the main menu and go to IP Settings and make the desired changes. Once the desired IP addresses are added to the Link Monitor list, click “Start”. If the IP address status shows a check mark the IP address is occupied. If the IP address status shows an X the IP address is available. Click “Stop” to stop the testing.
Application:
Add an IP camera or other network device to the current network group, the new IP address must not be occupied, otherwise it will cause IP conflicts and stop the equipment normal working. Link monitor can check if the new setting IP address is occupied.
RTSP Player :
The RTSP Player app will allow you to view the RTSP video stream from an IP camera. If you were unable to view your camera via the ONVIF or IPC Test apps, it is possible your camera will have an RTSP stream and you can view live video.
From the main menu, select the “APP Tool” folder and then select the “RTSP Player” to open the app.
If the IP camera uses MJPEG, select the RTSP icon. If the IP camera uses H.264, select the “RTSP HD” icon.
72
Local IP: This is the IP testers IP address. RTSP Add: This is where you can manually enter the IP camera’s RTSP URL or click on Search to
search the network for cameras that use an RTSP stream.
IPC Username: Enter the IP camera’s user name. IPC Password: Enter the IP camera’s password.
Once you have entered all the necessary information, select Enter at the bottom left to view the RTSP stream.
73
Note: in the event the ip tester does not auto detect the rtsp stream, refer to the specific camera manufacturer for the specific rtsp stream url. you may find this on line with a search of the camera model number and the word rtsp. Trace route:
Trace route is used to determine path of the IP packet access target. Note: Trace route testing results only for reference, for accurate test route tracking, Please use professional Ethernet tester.
Click to enter Trace Route
Input tracking IP address or domain name in the Remote Host IP. Set maximum hop count, normally default is 30
74
Click “start” to trace the goal address
3.3.21 APPS Tools
Click the icon to open the Tool Folder. You can move desktop icons into the Tools Folder by pressing on the icon for a few seconds until the screen below appears
You can also move an icon back to the desktop by pressing on the icon for a few seconds until it asks you if you want to move the icon back to the Desktop.
75
3.3.22 System Set
Click icon to enter
Language: Select your desired language: English, Chinese, Korean, Russian, Italian or Polish, etc. Date/Time: Set the Date/time IP setting: Manually set the IP address, Subnet Mask, Default Gateway, DNS address or select
“Dynamic allocation” to use DHCP. To test multiple network segments, click “Advanced” and then click “Add” to enter another IP address for the IP tester.
76
After setting an advanced IP address (refer to above photos), the tester can test two network segments (192.168.0.0) and (192.168.1.0). WLAN:Turn WiFi off or on by pressing the “Open the Wi-Fi” button. Once Wi-Fi is turned on, it will scan for wireless networks in your area. Select the desired wireless network SSID and enter your password to connect networks in your area.
Brightness::Set the desired brightness of the IP tester and adjust the sleep time settings. Volume: Set volume level. SD Card: Displays SD Card Capacity. You can also format the SD card or unmounts it before
removing it FTP serve: Once the IPC tester connects to a network, a computer can be used to read the SD card files via FTP.
77
Start the FTP server and then input the tester’s FTP address in the PC’s address bar. (ftp: as:ftp://192.168.0.233:2121) This will enable the PC to read, copy and edit the files from the SD card without the use of SD card reader
Version information: This displays the version information for each application. Screen rotation: Click on “Screen Rotation” to flip the IP tester’s display 180 degrees. This function is
very convenient for the user to connect the LAN cable on the bottom of the unit without having to flip the unit itself PTZ address scan: You can toggle the PTZ Address scan off or on before entering the PTZ controller app. This needs to be turned on in order to use the PTZ Scan feature of the PTZ app. Turn off option: If you select “Fast turn off”, the tester will shut down faster but data will not saved. To avoid unnecessary problems, it is recommended not to use the “Fast turn off” option
78
3.3.23 Update
Click to enter
If there are applications for updating, the applications will be displayed on the interface. Click the relevant applications to update to the latest version.
3.4 DC12V 1A power output
Touch function ,enter power output interface
79
Click the switch “OFF” to“ON” to turn on DC12V 1A power output function.. The smaller end of the supplied converter cable connects to the tester’s DC12V/1A OUTPUT and the other end connects to the camera’s power input. Power output function is mainly used in the camera field demonstration and testing, meanwhile, for some camera installation sites, if there is no power outlet for the adapter to power the camera, the tester can offer temporary power for it. But we do not suggest tester supply power for a long time.
Notice:
a. Don’t input any power into the “DC12/1A OUTPUT” port of the IP camera tester to avoid
destroy. man-made damage is not within the Company’s warranty
b. Don’t output this DC12V/1A power to DC12V/ IN port to avoid destroy. otherwise the tester will
damage, and man-made damage is not within the Company’s warranty.
c. The IPC tester power output is close to 1A, if the IP cameras power is over 1A, the tester will
auto enter protection mode. Disconnect all the connections of the tester and then connect the tester with power adaptor to resume the tester.
d. Make sure the tester has a sufficient charge otherwise the tester will not able to provide enough
output power.
3.5 Audio test
You can test the audio input from audio pickup devices by connecting the audio pickup device to the IP tester with the supplied audio cable. Support audio record and storage
80
4. Specifications
Model
IP Camera tester*models Optional
Display
3.5 inch Capacitive touch screen , resolution 480RGB)x 320
Network port
10/100M auto adapt,RJ45
SDI camera test
* (Optional)
1 channel SDI IN BNC Input, Support resolution 720p 60fps / 1080p 30fps /1080i 60fps
CVI camera test
*Optional
1 channel CVI inBNC interface, resolution max 720p 25,30,50,60fps / 1080p 25,30fps
TVI camera test
1 channel TVI inBNC interface, resolution max 720p 25,30,50,60fps / 1080p 25,30fps
AHD camera test
*Optional
1 channel AHD inBNC interface, resolution max 720p 25,30fps / 1080p 25,30fps
WIFI
Built in WIFI,speeds150M, allows you to connect to a wireless network and view IP camera
IP camera type
ONVIF,ONVIF PTZ, Dahua IPC-HFW2100P, Hikvision DS-2CD864-E13, Samsung SNZ-5200, Tiandy TD-NC9200S2, Kodak IPC120L, Honeywell HICC-2300T, RTSP Viewer. Customized welcome
Video input/output
1 channel BNC input & 1 channel BNC looped output, NTSC/PAL (Auto adapt)
Video level test:
Video signals measured in IRE or mV
Video level meter
* (Optional)
PEAK video signal level, SYNC signal level, Color Burst chroma level measurement
Zoom image
Supports Analog and IP camera image zooming & movement
Snapshot, Video record and
Capture still images and record live video. Media player will view photos and playback video
4.1 General Specifications
81
playback
12V/1Apower output
Output DC12V/1A power for camera
Audio test
1 channel audio signal input, test whether sound normal, supports record and save audio
PTZ control
Support RS485 control, Baud 600-115200bps, Compatible with more than 30 protocols such as PELCO-D/P, Samsung, Panasonic, Lilin, Yaan, etc
Video signal generator
Output one channel PAL/NTSC color bar video signal for testing monitor or video cable.(red, green ,blue, white and black color )
color bar generator
Local side PC can login the tester, send the signal by network ,test network connection communication whether normal
UTP cable tester
Test UTP cable connection status and display on the screen. Read the number on the screen
Data monitor
Captures and analyzes the command data from controlling device,also can send hexadecimal
Network test
IP address scan, link scan, and Ping test. Quickly search the for IP camera’s IP address on your network
Cable search * (Optional)
Find a connected cable from a bundle of cables using audio tones
PoE test
Measures PoE switch voltage and displays pin configuration
Digital Multimeter
* (Optional)
AC/DC Voltage,AC/DC current,Resistance,Capacitance,Data hold,Relative measurement,Continuity testing . Testing speed: 3 times/ seconds,Data range -6600+6600.
Optical power meter * (Optional)
Calibrated Wavelength(nm) :850/1300/1310/1490/1550/1625nm Power range(dBm) :-70~+10dBm
Visual fault locator
* (Optional)
Test fiber’s bending and breakage ( SM and MM fiber)
82
TDR cable test * (Optional)
Cable open circuit breakpoint and short circuit measurement(BNC cable, Coaxial cable, Cat5/6, telephone cable)
POWER
External power supply
DC 5V(1.5A )
Battery
Built-in 3.7V Lithium polymer battery ,.3000mAh
Rechargeable
After charging3~4 hours, normal working time 8 hours
Parameter
Operation setting
Capacitive touch screen, OSD menu, select your desired language: English, Chinese, Korean, Russian, Italian or Polish, etc
Auto off
1-30 (mins)
General
Working Temperature
-10---+50
Working Humidity
30%-90%
Dimension/Weight
194mm x 112mm x 48mm / 540g
Range
Accuracy
Resolution
660mV (Manual range)
±0.3%+4
0.1mV
Note: * signs means Optional function
4.2 Multi-meter specifications
Counts:-6600+6600 Conversion rate: 3times/s Current modes for clamp meter with ZERO function Isolation: the Multi-meter connector must be isolated with the other connector.
DC voltage
83
6.600V
1mV
66.00V
10mV
660.0V
100mV
Range
Accuracy
Resolution
660.0mV (Manual range)
±1.5%+6
0.1mV
6.600V
±0.8%+6
1mV
66.00V
10mV
660.0V
100mV
Range
Accuracy
Resolution
6.600mA
±0.5%+3
1uA
66.00mA
10uA
660.0mA
100uA
10.00A
±1%+5
10mA
Range
Accuracy
Resolution
6.600mA
±0.5%+3
1uA
66.00mA
10uA
660.0mA
100uA
10.00A
±1%+5
10mA
AC voltage
DC current
AC current
Resistance
84
Range
Accuracy
Resolution
660.0Ω
±0.8%+5
0.1Ω
6.600KΩ
±0.8%+2
66.00KΩ
10Ω
660.0KΩ
100Ω
6.600MΩ
1KΩ
66MΩ
±1.2%+5
10KΩ
Range
Resolution
Function
660.0Ω
0.1Ω
The measurement value less 30Ω±3Ω,the tester will
sound
Range
Resolution
Function
2.0V 1mV
Schottky diode:0.15~0.25V rectifier diode:0.6~1.0V triode PN junction:0.5~0.8V
Range
Accuracy
Resolution
6.600nF
±0.5%+20
1pF
66.00nF
±3.5%+8
10pF
660.0nF
100pF
6.600μF
1nF
66.00μF
10nF
660.0μF
±5%+8
100nF
Continuity
Diode
Capacitance
85
6.600mF
1μF
66.00mF
10μF
Measure Range(dBm)
-70+10dBm
Wavelength(nm)
850nm,1300nm,1310nm,1490nm,1550nm,1625nm
Detector
InGaAs
Uncertainly
±3%dB( -10dBm,22)
±5%dB(full range,22)
Display Resolution
Linear:0.1% ; Nonlinear:0.01dBm
Operating Temperature()
-10+50
Storage Temperature ()
-20+70
Connector type
FC/PC
Laser type
LD
Wavelength Calibration
650nm
Output power
5mWOptional 10mW,20mW
Modulation mode
CW/1Hz/2Hz
Measurement Range
5KMOptional 10-20KM
4.3 Optical power meter specifications
4.4 Visual fault locator specifications
86
Connector
FC/PC exchangeable
Working Temperature
10℃~+50
Operating Temperature
-20℃~+70
The data above is only for reference and any change of them will not be informed in advance. For more detailed