Avtec EA4000PBB User Manual

Low Volume Exhaust Canopy for Use Over 400°F & 600°F Cooking Equipment
EcoArch™ Energy Efficient Ventilation EA4000PBB
model EA4
Description:
The EA4 model with PBB make-up air canopy is UL 710 Listed for use over 400˚ and 600˚F commercial cooking appliances. This non compensating high exhaust velocity style canopy is intended for use over light and heavy-duty types of cooking appliances and is recommended for all projects where energy consumption is a factor or when adequate make up air is not available from the heating and cooling system.
Specifications:
Model EA4 PBB exhaust type I commercial kitchen ventilation canopy, incorporating PBB make-up air plenum box, UL 710 Listed without a fire damper in the exhaust collar. Canopy is constructed of a minimum 18 gauge stainless steel on all surfaces. Top of canopy to be constructed to incorporate exclusive aerodynamic arch. All exterior joints and seams shall be continuously welded liquid tight, ground smooth, and polished to a #4 finish. Construction to conform to NFPA 96 standards and shall meet UL 710 standards for operation. Canopy is constructed using the standing seam method for optimum strength. Exhaust Canopy shall be complete with stainless steel removable grease extractors running the full length of canopy. Grease extraction is accomplished by way of front located high velocity exhaust slot running the full length at the top of hood through grease filters. Grease filters are removable through exhaust plenum access doors. Grease trough is concealed within the hood and slopes to a removable grease cup located at the end of the front exhaust canopy. Canopy comes complete with UL Listed incandescent bulb type light fixtures.
Standard Features: Optional accessories:
• 3” Rear air space
• Full length concealed grease trough pitched to a removable grease cup
• Pre-drilled hanger brackets
• Stainless steel grease extractors
• Exclusive aerodynamic arch
Insulated 3” air space Pre-plumbed fire suppression Fire suppression complete installation Stainless steel top ceiling enclosures Utility fire system cabinet, mounted on end of hood Fan/light switches Stainless steel wall panel Exhaust fan / cooking equipment interlock control
• Front mounted exhaust plenum
• Front located high velocity exhaust slot
• PBB make-up air plenum box (attached or shipped loose)
• 1” thick supply air plenum insulation
Avtec, Unified Brands 888-994-7636, www.avtecind.com
Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications.
Avtec EcoArch Ventilation, Page 4
PP SPEC1004 Rev. D
Revised 08/08
PLAN VIEW
Model EA4
CROSS SECTION VIEW
ELEVATION VIEW
LIGHT AND MEDIUM DUTY
400°F EXHAUST CFM
140 CFM/LINEAR FT. 85 CFM/LINEAR FT. 175 CFM/LINEAR FT. 105 CFM/LINEAR FT.
LENGTH
4’-0” 560 4 x 10 340 8 x 24 700 4 x 14 420 8 x 24 5’-0” 700 4 x 14 425 8 x 24 875 4 x 16 525 8 x 24 6’-0” 840 4 x 16 510 8 x 24 1050 6 x 14 630 8 x 24 7’-0” 980 6 x 14 595 10 x 20 1225 6 x 16 735 10 x 20 8’-0” 1120 6 x 15 680 10 x 20 1400 6 x 18 840 10 x 30
9’-0” 1260 6 x 16 765 10 x 30 1575 6 x 20 945 10 x 30 10’-0” 1400 6 x 18 850 10 x 30 1750 6 x 24 1050 10 x 30 11’-0” 1540 6 x 20 935 10 x 30 1925 6 x 24 1155 10 x 40 12’-0” 1680 6 x 22 13’-0” 14’-0” 15’-0” 16’-0”
Note: Greater exhaust and/or lesser supply air flow rates may be required for each specific installation to obtain complete vapor and smoke removal. UL710 Listing information is available upon request. *Note: Hoods over 12’-0”in length require two exhaust duct collars. Exhaust collar sizing is based on an average range of 1700-1900FPM. Duct collars are located on centerline of canopy, unless otherwise specified. Canopy is to have a minimum 6” overhang on all exposed sides of cooking equipment.
CFM @ .70”SP
910 ea. 1820 Total
830 ea. 1960 Total 1050 ea. 2100 Total 1120 ea. 2240 Total
DUCT
COLLAR
(2) 6 x 12 (2) 6 x 14 (2) 6 x 14 (2) 6 x 16
LIGHT DUTY SUPPLY CFM
CFM @ .25”SP
510 ea. 1020 Total 552 ea. 1105 Total 595 ea. 1190 Total 638 ea. 1275 Total 680 ea. 1360 Total
COLLAR
(2) 8 x 24 2100 6 x 26 (2) 10 x 20 (2) 10 x 20
(2)10 x 20 (2)10 x 20
DUCT
HEAVY DUTY 600°F
EXHAUST CFM
CFM @ .80”SP
1138 ea 2275 Total 1225 ea. 2450 Total 1312 ea. 2625 Total 1400 ea. 2800 Total
DUCT
COLLAR
(2) 6 x 16 (2) 6 x 16 (2) 6 x 18 (2) 6 x 18
HEAVY DUTY SUPPLY CFM
CFM @ .35”SP
630 ea. 1260 Total 683 ea. 1365 Total 735 ea. 1470 Total 788 ea. 1575 Total 840 ea. 1680 Total
DUCT
COLLAR
(2) 8 x 24 (2) 10 x 20 (2) 10 x 20 (2) 10 x 30 (2) 10 x 30
NFPA-96
1055 Mendell Davis Drive, Jackson, MS 39272 888-994-7636, unifiedbrands.net
Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications.
Loading...