Avtec BLEH Service Manual

Project: Item
#
Prepared for: Date:
Island Utility Distribution System Model IL * *
DESIGN FEATURES
U. L. Listed. Complies with all national codes.
Pre-engineered, S/S construction.
Flexibility for change
Ease of cleaning and service
S/S Service Tower Each End
OPTIONS AND ACCESSORIES
• Matching Cord Sets
• Matching Plumbing Connectors
• Gas Solenoid Valve
• Mechanical Gas Valve
• Manual Gas Shut Off Valve AVTEC INDUSTRIES INC. 120 KENDALL POINT DR. OSWEGO, IL 60543 [630] 851-4800
** MODEL NUMBER GUIDE
Island model IL is available with the following services. All models are 12" high x 6" deep, except models I LEO and ILGO, which are 6" high. Lengths are in 6, 9 and 12 ft. increments.
Model IL * *
EO = Electric only GH = Gas, hot water GO= Gas only GC = Gas, cold water
EG = Electric, gas GW = Gas, HW, CW EH = Electric, hot water UH = Electric, gas, hot water EC = Electric, cold water DC = Electric, gas, cold water EW = Electric, HW, CW UW = Electric, gas, HW, CW
SPECIFICATIONS
Provide AVTEC U.L. Listed, island type, LOCO UDS System, Model No. __________ with (electric chase)(1 1/2" N.P.T. gas manifold) (1/2" N.P.T. (hot) (and) (cold) water manifold). System shall be (6")(12") hiqh x 6" wide x __ft. long O/A, in (6')(9')(12') increments, and constructed of (#304) (#430) stainless steel with #4 finish. Provide service tower each end and tubular legs with flanged feet at each field joint. Provide NEMA receptacles and plumbing connections for (3/4" gas) (1/2" hot water) (1/2" cold water) where indicated on drawing.
Also Provide:
Matching cord sets where indicated Watertight receptacles 1/4 turn ball valves where indicated Matching (gas) (water) QD & connectors where indicated.
(Mechanical)(Electric solenoid) gas valve(s) and manual shut off (one)(each) end.
LOCO ISLAND UDS MODEL #IL__ PROJECT:_______________________________ ITEM #______
AVTEC INDUSTRIES INC. 120 KENDALL POINT DR. OSWEGO, IL 60543 FAX [630] 851-5777
AVTEC's policy of continuous product improvement includes the right to change specifications without notice.
Project item #______
Prepared for Date:
Backsplash Utility Distribution System Model BL * *
DESIGN FEATURES
U.L. Listed. Complies with all national codes
Pre-engineered, S/S construction
Flexibility for change
Ease of cleaning and service
Highly Flexible S/S Water Connectors
OPTIONS AND ACCESSORIES
• Matching Cord Sets
• Matching Water Connectors
• Matching Water Quick-Disconnect
**MODEL NUMBER GUIDE
Backsplash model BL is available with the following services. Electric and water models are 9" high x 2" deep; electric only are 6" high x 2" deep. Lengths are in 3, 6, 9, 12ft. increments. Filler pieces are provided and cut to size in the field. Lengths over 12 ft. and filler pieces must be field attached.
Model BL * *
EO = Electric only EH = Electric and hot water EC = Electric and cold water
SPECIFICATIONS
Provide AVTEC U.L. Listed, backsplash mounted, LOCO UDS System, Model No. __________, with (electric chase)(3/8" (hot) (cold) water manifold). System shall be (6")(9") high x 2" deep x __ ft. long O/A in (3') (6') (9') (12') increments, and constructed of 300 Series stainless steel with a # 4 finish. Provide NEMA receptacles on front, K.O's on bottom, and capped nipples on front and bottom where indicated.
Also provide:
Matching cord sets where indicated. Watertight receptacles Matching quick-disconnect
Matching hose connector
AVTEC INDUSTRIES INC. 120 KENDALL POINT DR. OSWEGO, IL 60543 [630] 851-4800
LOCO BACKSPLASH UDS MODEL # BL _ _ PROJECT: ITEM #
AVTEC INDUSTRIES INC. 120 KENDALL POINT DR. OSWEGO, IL 60543 FAX [630] 851-5777
AVTEC's policy of continuous product improvement includes the right to change specifications without notice.
Project: Item #
UC =
Electric, gas, cold
Prepared for Date:
Wall Mounted Utility Distribution System Model WL * *
DESIGN FEATURES
U.L. Listed. Complies with all national codes.
Pre-engineered, S/S construction.
Flexibility for change.
Ease of cleaning and service.
OPTIONS AND ACCESSORIES
• Matching Cord Sets
• Matching Plumbing Connectors
• S/S Service Enclosure(s)
• Gas Solenoid Valve
• Mechanical Gas Valve
• Manual Gas Shut Off Valve
**MODEL NUMBER GUIDE
Wall model WL is available with the following services. All models are 12" high x 6" deep, except models WLEO and WLGO, which are 6" high. Lengths are in 6, 9 and 12 ft. increments.
Model EO = Electric only WL* * GH = Gas, hot water GO = Gas only
EG = Electric, gas EH = Electric, hot water EC = Electric, cold water EW = Electric, HW, CW
SPECIFICATIONS
Provide AVTEC U.L. Listed, wall mounted, LOCO UDS System, Model No. __________ with (electric chase) (1 1/2" N.P.T. gas manifold) (1/2" N.P.T. (hot) (cold) water manifold). System shall be (6") (12") high x 6" wide x __ft. long O/A,in (6') (9') (12') increments, and constructed of (#304) (#430) stainless steel with #4 finish. Provide NEMA receptacles and plumbing connections for (1/2" gas) (1/2" hot water) (1/2" cold water) where indicated on drawing.
Also provide:
Matching cord sets where indicated Watertight receptacles 1/4 turn ball valves where indicated Matching (gas) (water) QD & connectors where indicated. (Mechanical) (Electrical solenoid) gas valve(s) and manual shut off (one) (each) end. ___” w x ___” h service enclosure panel (one) (each) end. ___” w x ___” h service enclosure panel (one) (each) end.
UW = Electric, gas, HW, CW
AVTEC INDUSTRIES INC. 120 KENDALL POINT DR. OSWEGO, IL 60543 [630]851-4800
LOCO WALL UDS MODEL #WL __ PROJECT: ITEM #_______
AVTEC INDUSTRIES INC. 120 KENDALL POINT DR. OSWEGO, IL 60543 FAX[630] 851-4800
AVTEC's policy of continuous product improvement includes the right to change specifications without notice.
Project: Item #______ Prepared for: Date:_______
Counter Utility Distribution System Model CL * *
DESIGN FEATURES
U.L. Listed. Complies with all national codes
Pre-engineered, S/S construction
Flexibility for change
Ease of cleaning and service
Highly Flexible S/S Water Connectors
OPTIONS AND ACCESSORIES
• Matching Cord Sets
• Matching Water Connectors
• Matching Water Quick-Disconnect
* *MODEL NUMBER GUIDE
Counter model CL is available with the following services. Electric and water models are 9" high x 3" deep; electric only are 51/4" high x 3" deep. Lengths are in 3, 6, 9, 12 ft. increments. Filler pieces are provided and cut to size in the field. Lengths over 12 ft. and filler pieces must be field attached.
Model CL. * * EO = Electric only
EH = Electric and hot water EC = Electric and cold water EW = Electric, hot and cold water
Provide AVTEC U.L Listed, counter mounted, LOCO UDS
System, Model No._______________, with (electric chase) (3/8" (hot) (and) (cold) water manifold). System shall be (5 1/4") (9") high x 3" deep x__ft. long O/A in (3') (6') (9') (12') increments, and constructed of 300 Series stainless steel with a # 4 finish. Provide NEMA receptacles on front, K.O's on bottom, and capped nipples on front and bottom where indicated.
Also provide:
Matching cord sets where indicated Watertight receptacles Matching quick-disconnect Matching hose connector
SPECIFICATIONS
AVTEC INDUSTRIES INC. 120 KENDALL POINT DR. OSWEGO, IL 60543 (630)851-4800
LOCO BACKSPLASH UDS MODEL # CL__ PROJECT: ITEM #_____
AVTEC INDUSTRIES INC. 120 KENDALL POINT DR. OSWEGO, IL 60543 FAX(630)851-5777
AVTEC's policy of continuous product improvement includes the right to change specifications without notice.
Loading...